Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “pumps”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

Generation of Optical Combs in a WGM Resonator from a Bichromatic Pump

Optical combs generated by a monolithic resonator with Kerrmedium can be used in a number of applications, including orbital clocks and frequency standards of extremely high accuracy, such as astronomy, molecular spectroscopy, and the like. The main difficulty of this approach is the relatively high pump power that has to be used in such devices, causing undesired thermorefractive effects, as well as stimulated Raman scattering, and limiting the optical comb quality and utility. In order to overcome this problem, this innovation uses a different approach to excitation of the nonlinear oscillations in a Kerr-nonlinear whispering gallery mode (WGM) resonator and generation of the optical comb. By coupling to the resonator two optical pump frequencies instead of just one, the efficiency of the comb source can be increased considerably. It therefore can operate in a lowerpower regime where the undesirable effects are not present. This process does not have a power threshold; therefore, the new optical component can easily be made strong enough to generate further components, making the optical comb spread in a cascade fashion. Additionally, the comb spacing can be made in an arbitrary number of the resonator free spectral ranges (FSR). The experimental setup for this innovation used a fluorite resonator with OMEGA= 13.56 GHz. This material has very low dispersion at the wavelength of 1.5 microns, so the resonator spectrum around this wavelength is highly equidistant. Light was coupled in and out of the resonator using two optical fibers polished at the optimal coupling angle. The gap between the resonator and the fibers, affecting the light coupling and the resonator loading, was controlled by piezo positioners. The light from the input fiber that did not go into the resonator reflected off of its rim, and was collected by a photodetector. This enabled observation and measurement of the (absorption) spectrum of the resonator. The input fiber combined light from two lasers centered at around 1,560 nanometers. Both laser frequencies were simultaneously scanned around the selected WGMs of the same family. However, they were separated by one, two, three, or ten FSRs. This was achieved by fine-tuning each laser frequency offset until the selected resonances overlap on the oscilloscope screen. The resonator quality factor Q = 7 x 10(exp 7) was relatively low to increase the linewidth and, therefore, the duty cycle of both lasers simultaneously coupled into their WGMs. The optical spectrum analyzer (OSA) connected to the output fiber was continuously acquiring data, asynchronously with the laser scan. The instrument was set to retain the peak power values; therefore, a trace recorded for a sufficiently long period of time reflected the situation with both lasers maximally coupled to the WGMs.

Strekalov, Dmitry V.↗

Compact, Efficient Drive Circuit for a Piezoelectric Pump

A switching circuit that drives a piezoelectric pump at a high voltage with a polarity that alternates at the desired mechanical pump frequency is described and depicted. This circuit offers advantages of (1) high energy efficiency relative to conventional direct-drive circuits and (2) compactness relative to conventional resonant drive circuits.

Matice, Chris↗

Microscale Thermal-Transpiration Gas Pump

A recent addition to the growing class of microelectromechanical systems (MEMS) is a single stage of a Knudsen compressor. This device was fabricated and tested to demonstrate the feasibility of Knudsen compressors as miniature vacuum pumps for future portable scientific instruments. The attributes of Knudsen compressors that make them attractive as miniature vacuum pumps are that they contain no moving parts and operate without need for lubricants or working fluids.

Vargo, Stephen↗

Development of a Dual-Pump CARS System for Measurements in a Supersonic Combusting Free Jet

This work describes the development of a dual-pump CARS system for simultaneous measurements of temperature and absolute mole fraction of N2, O2 and H2 in a laboratory scale supersonic combusting free jet. Changes to the experimental set-up and the data analysis to improve the quality of the measurements in this turbulent, high-temperature reacting flow are described. The accuracy and precision of the instrument have been determined using data collected in a Hencken burner flame. For temperature above 800 K, errors in absolute mole fraction are within 1.5, 0.5, and 1% of the total composition for N2, O2 and H2, respectively. Estimated standard deviations based on 500 single shots are between 10 and 65 K for the temperature, between 0.5 and 1.7% of the total composition for O2, and between 1.5 and 3.4% for N2. The standard deviation of H2 is ~10% of the average measured mole fraction. Results obtained in the jet with and without combustion are illustrated, and the capabilities and limitations of the dual-pump CARS instrument discussed.

Magnotti, Gaetano↗

Dual-Pump CARS Development and Application to Supersonic Combustion

A dual-pump Coherent Anti-Stokes Raman Spectroscopy (CARS) instrument has been developed to obtain simultaneous measurements of temperature and absolute mole fractions of N2, O2 and H2 in supersonic combustion and generate databases for validation and development of CFD codes. Issues that compromised previous attempts, such as beam steering and high irradiance perturbation effects, have been alleviated or avoided. Improvements in instrument precision and accuracy have been achieved. An axis-symmetric supersonic combusting coaxial jet facility has been developed to provide a simple, yet suitable flow to CFD modelers. Approximately one million dual-pump CARS single shots have been collected in the supersonic jet for varying values of flight and exit Mach numbers at several locations. Data have been acquired with a H2 co-flow (combustion case) or a N2 co-flow (mixing case). Results are presented and the effects of the compressibility and of the heat release are discussed.

Magnotti, Gaetano↗

Dual-pump CARS of Air in a Heated Pressure Vessel up to 55 Bar and 1300 K

Dual-pump Coherent anti-Stokes Raman scattering (CARS) measurements have been performed in a heated pressure vessel at NASA Langley Research Center. Each measurement, consisting of 500 single shot spectra, was recorded at a fixed location in dry air at various pressures and temperatures, in a range of 0.03-55×10(exp 5) Pa and 300-1373 K, where the temperature was varied using an electric heater. The maximum output power of the electric heater limited the combinations of pressures and temperatures that could be obtained. Charts of CARS signal versus temperature (at constant pressure) and signal versus pressure (at constant temperature) are presented and fit with an empirical model to validate the range of capability of the dual-pump CARS technique; averaged spectra at different conditions of pressure and temperature are also shown.

Cantu, Luca↗

International Space Station (ISS) External Thermal Control System (ETCS) Loop A Pump Module (PM) Jettison Options Assessment

On December 11, 2013, the International Space Station (ISS) experienced a failure of the External Thermal Control System (ETCS) Loop A Pump Module (PM). To minimize the number of extravehicular activities (EVA) required to replace the PM, jettisoning the faulty pump was evaluated. The objective of this study was to independently evaluate the jettison options considered by the ISS Trajectory Operations Officer (TOPO) and to provide recommendations for safe jettison of the ETCS Loop A PM. The simulation selected to evaluate the TOPO options was the NASA Engineering and Safety Center's (NESC) version of Program to Optimize Simulated Trajectories II (POST2) developed to support another NESC assessment. The objective of the jettison analysis was twofold: (1) to independently verify TOPO posigrade and retrograde jettison results, and (2) to determine jettison guidelines based on additional sensitivity, trade study, and Monte Carlo (MC) analysis that would prevent PM recontact. Recontact in this study designates a propagated PM trajectory that comes within 500 m of the ISS propagated trajectory. An additional simulation using Systems Tool Kit (STK) was run for independent verification of the POST2 simulation results. Ultimately, the ISS Program removed the PM jettison option from consideration. However, prior to the Program decision, the retrograde jettison option remained part of the EVA contingency plan. The jettison analysis presented showed that, in addition to separation velocity/direction and the atmosphere conditions, the key variables in determining the time to recontact the ISS is highly dependent on the ballistic number (BN) difference between the object being jettisoned and the ISS.

Murri, Daniel G.↗

A Liquid-Liquid Thermoelectric Heat Exchanger as a Heat Pump for Testing Phase Change Material Heat Exchangers

The primary objective of the Phase Change HX payload on the International Space Station (ISS) is to test and demonstrate the viability and performance of Phase Change Material Heat Exchangers (PCM HX). The system was required to pump a working fluid through a PCM HX to promote the phase change material to freeze and thaw as expected on Orion's Multipurpose Crew Vehicle. Due to limitations on ISS's Internal Thermal Control System, a heat pump was needed on the Phase Change HX payload to help with reducing the working fluid's temperature to below 0degC (32degF). This paper will review the design and development of a TEC based liquid-liquid heat exchanger as a way to vary to fluid temperature for the freeze and thaw phase of the PCM HX. Specifically, the paper will review the design of custom coldplates and sizing for the required heat removal of the HX.

Sheth, Rubik B.↗

Generation of High Pressure Oxygen via Electrochemical Pumping in a Multi-stage Electrolysis Stack

An oxygen pump can produce high-purity high-pressure oxygen. Oxygen ions (O.sup.2-) are electrochemically pumped through a multi-stage electrolysis stack of cells. Each cell includes an oxygen-ion conducting solid-state electrolyte between cathode and anode sides. Oxygen dissociates into the ions at the cathode side. The ions migrate across the electrolyte and recombine at the anode side. An insulator is between adjacent cells to electrically isolate each individual cell. Each cell receives a similar volt potential. Recombined oxygen from a previous stage can diffuse through the insulator to reach the cathode side of the next stage. Each successive stage similarly incrementally pressurizes the oxygen to produce a final elevated pressure.

Setlock, John A↗

Effects of Alternate Leading Edge Cutback on the Space Shuttle Main Engine Low Pressure Fuel Pump

A higher order cavitation oscillation observed in the SSME low pressure fuel pump has been eliminated in water flow testing of a modified subscale replica of the inducer. The low pressure pump was modified by removing the outboard sections of two opposing blades of the four-bladed inducer, blending the "cutback" regions into the blades at the leading edge and tip, and removing material on the suction sides to decrease the exposed leading edge thickness. The leading edge tips of the cutback blades were moved approximately 25 degrees from their previous locations, thereby increasing one blade to blade spacing, decreasing the second, while simultaneously moving the cutback tips downstream. The test was conducted in MSFC's inducer test loop at scaled operating conditions in degassed and filtered water. In addition to eliminating HOC across the entire scaled operating regime, rotating cavitation was suppressed while the range of both alternate blade and asymmetric cavitation were increased. These latter phenomena, and more significantly, the shifts between these cavitation modes also resulted in significant changes to the head coefficient at low cavitation numbers. Reverse flow was detected at a slightly larger flow coefficient with the cutback inducer and suction capability was reduced by approximately 1 velocity head at and above approximately 90% of the reference flow coefficient. These performance changes along with more intense reverse flow are consistent with poor flow area management and increased incidence in the cutback region. Although the test demonstrated that the inducer modification was successful at eliminating the higher order cavitation across the entire scaled operating regime, different, previously unobserved, cavitation oscillations were introduced and significant performance penalties were imposed.

Mulder, Andrew↗

A Solar-Pumped Fluorescence Model for Line-By-Line Emission Intensities in the B-X, A-X, and X-X Band Systems of 12C14N

We present a new quantitative model for detailed solar-pumped fluorescent emission of the main isotopologue of CN. The derived fluorescence efficiencies permit estimation and interpretation of ro-vibrational infrared line intensities of CN in exospheres exposed to solar (or stellar) radiation. Our g-factors are applicable to astronomical observations of CN extending from infrared to optical wavelengths, and we compare them with previous calculations in the literature. The new model enables extraction of rotational temperature, column abundance, and production rate from astronomical observations of CN in the inner coma of comets. Our model accounts for excitation and de-excitation of rotational levels in the ground vibrational state by collisions, solar excitation to the A(sup 2)Pi(sub I) and B(sup 2)Sum(sup +) electronically excited states followed by cascade to ro-vibrational levels of X(sup 2)Sum(sup +), and direct solar infrared pumping of ro-vibrational levels in the X(sup 2)Sum(sup +) state. The model uses advanced solar spectra acquired at high spectral resolution at the relevant infrared and optical wavelengths and considers the heliocentric radial velocity of the comet (the Swings effect) when assessing the exciting solar flux for a given transition. We present model predictions for the variation of fluorescence rates with rotational temperature and heliocentric radial velocity. Furthermore, we test our fluorescence model by comparing predicted and measured line-by-line intensities for X(sup 2)Sum(sup +) (1-0) in comet C/2014 Q2 (Lovejoy), thereby identifying multiple emission lines observed at IR wavelengths.

Emission↗

Generation of High Pressure Oxygen via Electrochemical Pumping in a Multi-Stage Electrolysis Stack

An oxygen pump can produce high-purity high-pressure oxygen. Oxygen ions (O(2-)) are electrochemically pumped through a multi-stage electrolysis stack of cells. Each cell includes an oxygen-ion conducting solid-state electrolyte between cathode and anode sides. Oxygen dissociates into the ions at the cathode side. The ions migrate across the electrolyte and recombine at the anode side. An insulator is between adjacent cells to electrically isolate each individual cell. Each cell receives a similar volt potential. Recombined oxygen from a previous stage can diffuse through the insulator to reach the cathode side of the next stage. Each successive stage similarly incrementally pressurizes the oxygen to produce a final elevated pressure.

Setlock, John A↗

Experimental Configuration and Preliminary Results of Testing a Rapid Cycle Adsorption Pump for Martian CO2 Acquisition

Temperature-swing adsorption pumps have been proposed as a method of acquiring and compressing Martian atmospheric CO2 for downstream processing. Most industrial applications and previous research targeted at space in-situ resource utilization (ISRU) utilize long (~hours) temperature swing periods, typically limited by the ability to transfer heat from a naturally insulating sorbent bed. A rapid cycle adsorption pump (RCAP) would reduce these periods to minutes, in the hope of increasing overall throughput. This paper details the design and preliminary experimental results from testing an RCAP in a simulated Martian environment. The test configuration features a central, liquid-cooled and heated heat transfer plate surrounded by symmetrical rectangular sorbent beds. Various bed thicknesses and commercially available Zeolite 13X sorbent particle sizes are evaluated to both determine performance and provide data for a parallel modeling effort. Discussions of multi-stage configurations and methods of boosting bed conductivity are included.

Berg, Jared↗

Experimental Design and Preliminary Analysis of a Mars CO2 Rapid Cycle Adsorption Pump

Temperature-swing adsorption pumps have been proposed as a method of acquiring and compressing Martian atmospheric CO2 for downstream processing. Most industrial applications and previous research targeted at space in-situ resource utilization (ISRU) utilize long (~hours) temperature swing periods, typically limited by the ability to transfer heat from a naturally insulating sorbent bed. A rapid cycle adsorption pump (RCAP) would reduce these periods to minutes, in the hope of increasing overall throughput. This paper details the design and preliminary experimental results from testing an RCAP in a simulated Martian environment. The test configuration features a central, liquid-cooled and heated heat transfer plate surrounded by symmetrical rectangular sorbent beds. Various bed thicknesses and commercially available Zeolite 13X sorbent particle sizes are evaluated to both determine performance and provide data for a parallel modeling effort. Discussions of multi-stage configurations and methods of boosting bed conductivity are included.

Rapid Cycle Adsorption↗

Fabrication and Performance of Planar Schottky Diodes with T-gate-like Anodes in 200 GHz Subharmonically-Pumped Waveguide Mixers

A T-gate-like structure has been developed, fabricated and tested as the anode for millimeter and submillimeter-wave Schottky diodes. The low parasitics of the T-anode diodes yield extremely high cutoff frequencies, making the diodes useable at frequencies well beyond 1 THz. The diodes were tested as an antiparallel-pair, integrated monolithically with microstrip circuitry on a quartz substrate, in a subharmonically pumped waveguide mixer. A double sideband noise temperature of 600 K with a conversion loss of 4.7 dB were measured at 200 GHz. This is believed to be the lowest noise temperature ever reported for a room temperature subharmonically-pumped Schottky diode mixer at this frequency.

Planar↗

Impact of Fluid Flow Pressure drop on Temperature of Components Controlled by Mechanically Pumped Fluid Loop Thermal Control System

In a typical thermal control system that employs a mechanically pumped fluid loop to control component temperatures, fluid flow pressure drop is minimized to ensure that adequate fluid flow can be provided by the pump. Engineers often are overly concerned about violating a maximum pressure drop, almost treating it as a “wall” that should not be crossed. The true “wall” is the control of the temperatures of the components served by the loop to ensure that their temperatures do not violate their allowed limits. As a case study, for assessing this “constraint,” sensitivity analyses were undertaken to understand if this is truly a major constraint, and to assess the impact of pressure drop exceedance on the controlled components’ temperatures. The flow impedance is varied as a parameter to understand how it affects the controlled components’ temperatures. One key finding was that the temperatures of the controlled components is relatively insensitive to the flow impedance increases. This finding is obviously most relevant to this particular case study; however, this also provides the process and guidance for assessing the performance of other pump/loop combinations in terms of their sensitivity to pressure drop impedances.

Mastropietro, Arthur J.↗

Performance Evaluation of a Vapor-compression-cycle Based Heat Pump System for a Lunar Habitat under the Impact of Dust Deposits on the Coupled Radiators

Space exploration gains new momentum. A near goal is set by NASA to return humans to the Moon andestablish a sustainable presence on the lunar surface for more repeatable and affordable expeditions.The lunar dust is one of the dangerous environment hazard causing serious problems for explorationactivities. In this paper, in order to study the impact of lunar dust on the performance of a thermalmanagement system for a lunar habitat, a dynamical model of an active thermal control system that iscomprised of a vapor-compression cycle heat pump and a radiator loop is developed. A heat pump to liftthe heat rejection temperature is required due to high lunar daytime surface temperature. Parametricstudies on radiator size, percentage of dust coverage on the radiator, and lunar habitat location arecarried out. The results show that lunar deposits can significantly increase the power consumption ofthe thermal management system. A dust covered radiator panel results in net heat input to the heattransfer fluid during the period of strong solar irradiance, causing deteriorated performance of theradiator loop. The lunar dust contamination problem raises the requirement of redundancy design of asystem for fault tolerance. A synergetic design of a thermal management system, a power generationsystem and robotic maintenance system is proposed to achieve maximal mass cut for a whole lunarhabitat system.

Chunjian Pan↗

Dynamic Modelling and Performance Evaluation of a Chemisorption Heat Pump for Cold Climate

Space heating is a significant contributor to the energy consumption in residential buildings, especially in cold climates where electric-driven heat pumps lose the advantage of high efficiency and conventional gas-combustion furnaces have limited efficiency. Chemical adsorption (chemisorption) heat pumps (CSHP) have the potential for producing heating with high energy efficiency under cold operating conditions. A CSHP operates intermittently between desorption and adsorption modes, and their performance is affected by system design and transient system control. This study developed a dynamic model and used it to evaluate the daily system performance under different designs and controls, particularly the buffer tank size and the controlled minimum heating power. The simulation results revealed the effects of these parameters on the system performance and helped identify the optimal design and control for the highest coefficient of performance and heating capacity.

Yang, Zhiyao↗