Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “pump efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

Frequency stability and offset locking of a laser-diode-pumped Nd:YAG monolithic nonplanar ring oscillator

The frequency stability of laser-diode-pumped, monolithic Nd:YAG solid-state unidirectional nonplanar ring oscillators was studied by heterodyne measurements. CW single-axial- and transverse-mode power of 25 mW at 1064 nm was obtained at a slope efficiency of 19 percent. Two independent oscillators were offset-locked at 17 MHz with frequency fluctuations of less than + or - 40 kHz for periods of 8 min.

Kane, Thomas J.↗

Improved Regenerative Sorbent-Compressor Refrigerator

Conceptual regenerative sorbent-compressor refrigerator attains regeneration efficiency and, therefore, overall power efficiency and performance greater than conventional refrigerators. Includes two fluid loops. In one, CH2FCF3 (R134a) ciculates by physical adsorption and desorption in four activated-charcoal sorption compressors. In other, liquid or gas coolant circulated by pump. Wave of regenerative heating and cooling propagates cyclically like peristatic wave among sorption compressors and associated heat exchangers. Powered by electricity, oil, gas, solar heat, or waste heat. Used as air conditioners, refrigerators, and heat pumps in industrial, home, and automotive applications.

Jones, Jack A.↗

Phase 1 Space Fission Propulsion System Design Considerations

Fission technology can enable rapid, affordable access to any point in the solar system. If fission propulsion systems are to be developed to their full potential; however, near-term customers must be identified and initial fission systems successfully developed, launched, and operated. Studies conducted in fiscal year 2001 (IISTP, 2001) show that fission electric propulsion (FEP) systems operating at 80 kWe or above could enhance or enable numerous robotic outer solar system missions of interest. At these power levels it is possible to develop safe, affordable systems that meet mission performance requirements. In selecting the system design to pursue, seven evaluation criteria were identified: safety, reliability, testability, specific mass, cost, schedule, and programmatic risk. A top-level comparison of three potential concepts was performed: an SP-100 based pumped liquid lithium system, a direct gas cooled system, and a heatpipe cooled system. For power levels up to at least 500 kWt (enabling electric power levels of 125-175 kWe, given 25-35% power conversion efficiency) the heatpipe system has advantages related to several criteria and is competitive with respect to all. Hardware-based research and development has further increased confidence in the heatpipe approach. Successful development and utilization of a "Phase 1" fission electric propulsion system will enable advanced Phase 2 and Phase 3 systems capable of providing rapid, affordable access to any point in the solar system.

Houts, Mike↗

4-Pass Pumping of Nd+3:YAG Slabs

A solid-state, side pumping scheme, designed to enhance pump energy absorption, has been adapted for use in small, side-pumped, Nd+3:YAG zigzag lasers. This technique allows for pump radiation to make four complete passes through the gain medium, effectively doubling the absorption length of the usual 2-pass geometry. This produces higher inversion densities, higher gains, broader operating temperature bands and overall higher efficiencies. The improved performance has been demonstrated with a small Nd+3:YAG, mJ-class oscillator, and will aid in the development for space-based remote sensing laser transmitters for altimetry and mapping instruments.

Coyle, D. Barry↗

TPSAS-NF1676L-14096-DND

This technology development was initiated during NASA Earth Science Technology Office (ESTO) funded Laser Risk Reduction Program (LRRP) with the objective to develop a Thulium (Tm) fiber laser pumped Holmium (Ho) solid-state laser that generates laser pulses in the 2?m wavelength for pulsed CO2 DIAL/IPDA instrument. The key performance characteristics of this laser, such as energy, pulse repetition rate, pulse width, efficiency, frequency accuracy and stability, will meet or exceed the needs of the NASA Active Sensing of CO2 Emissions over Night, Days, and Seasons (ASCENDS) transmitter as currently envisioned. This space qualifiable laser architecture utilizes fiber laser and solid-state crystal laser technologies. One of the outstanding properties of the fiber laser is its efficiency. However, it inherently has low damage threshold at high energy pulses. On the other hand, the solid state laser has the capability to produce Joule-level energy at 2?m wavelength. The proposed laser combines the advantages of both lasers to provide the desired energy with high efficiency.

Upendra N Singh↗

Integrated Bosch Process System Models for In-Situ Oxygen and Carbon Production

In-Situ Resource Utilization (ISRU) technology is a vital component to NASA’s mission of a sustainable presence on the Moon and Mars. Local resources can be leveraged to reduce resupply frequency and mass. Elements of the Bosch process, combined with the carbothermal reduction process, can produce oxygen on the lunar surface with minimal consumables. The Bosch process can also produce oxygen on the Martian surface by using the CO 2 -rich environment. Between both systems, adsorption pump, solar thermal energy, carbon formation reactor, and water recovery subsystems are modeled and integrated to create a functional model in MATLAB software. The model is used to simulate performance of the system and reduce mass, power, and volume requirements. This integrated system model provides a tool to scale ISRU technologies for oxygen and carbon production. The MATLAB model is created by developing a system of independent subsystem models that are solved for their quasi-steady state values which can be integrated with respect to time to determine the change in current states. A flexible time stepping method is used to ensure a high level of accuracy during periods of rapid change while still making use of a simple explicit integration method. The flexible time step is calculated for each independent subsystem and the minimum value from those is used as the overall time step. A flexible time step is calculated by dividing a resolution value, or the maximum change per time step, by the variables current rate of change. The maximum value from all points in space is used for subsystem models that contain multiple values. The process is done for every variable that is being monitored in each subsystem and the global minimum is used as that iteration’s timestep. Several assumptions used in the MATLAB model for fluid flow dynamics, such as 1-D gas flow through the sorption pump, are supported by modeling in Ansys Fluent software. The Lunar oxygen production system is outlined in Fig. 1. The carbothermal reduction subsystem uses solar energy to heat a mixture of lunar regolith and carbon powder to produce carbon monoxide. To begin, the carbon monoxide feeds to the modified Bosch subsystem along with hydrogen gas. The reactants then enter the carbon formation reactor where water and carbon powder are produced. Solar thermal energy is used to add energy to the reactor, but waste heat from the carbothermal process is another potential heat source. The water is collected and electrolyzed to produce hydrogen which reenters the Bosch subsystem, and the oxygen is stored for downstream use. The carbon powder is collected and feeds back into the carbothermal subsystem. The Martian oxygen production system uses the full Bosch process and is outlined in Fig 2. A CO 2 adsorption pump thermally cycles to scrub and pressurize CO 2 from the environment. Along with an initial supply of hydrogen, the reactants enter the Reverse Water Gas Shift Reactor (RWGSR) which produces carbon monoxide and water. Carbon monoxide and unreacted hydrogen enter the carbon formation reactor to produce water and carbon powder. The water is collected from both reactors and electrolyzed to reintroduce hydrogen and store oxygen for propellant production or life support. Carbon is removed from the carbon formation reactor and stored. The adsorption pump utilizes rapid cycle temperature swings within a stack of zeolite coated surfaces. The subsystem model solves 1-D quasi-steady conservation laws of the quasi-steady form, shown in Eq. 1, for the gas stream and heat exchange liquid to predict performance parameters such as breakthrough capacity and optimum cycle time. The source term S is used to capture interactions between the fluid flows and the sorbent. A quasi-steady-state scheme is used where no time derivatives appear in the governing equations, except for those in the source terms. This results in an autonomous system, where ∂F/∂x = ƒ(F). The fluxes F are provided at the inlet, and an explicit method is used to solve for the spatial distribution of F. The heat and mass flows to the sorbent are then extracted from the source terms. These flows are numerically integrated to produce a 1-D solution for the system’s state as a function of both time and space. The body of the adsorption pump is separated into two semi-independent models: the heat exchanger fluid flow and gas flow through the zeolite coated surfaces. Both models are solved using the above-described method to find a 1-D solution as a function of space and interact only once a timestep is taken. The interaction point is the sorbent through which all heat transfer between the two models must occur. Sorbent mass adsorption is calculated using the Lagergren model, shown in Eq. 2, where the transfer coefficient, λ D , is found by solving a system of nondimensionalized equations derived by using the heat and mass transfer analogy for transport phenomena. Using Grade 544 Type 13X zeolite as the sorbent material, the equilibrium concentration, θ eq , is calculated using the k-site Langmuir isotherm and fit parameters. Additionally, the enthalpy of adsorption used in the model is computed by interpolation of available data [1]. The subsystem model was validated using the Rapid Cycle Temperature Swing Adsorption (RC-TSA) pump. The solar thermal energy subsystem focuses on a solar concentrator concept with a heat exchanger to heat the reactants before entering the carbon formation reactor. The subsystem model assumes a fixed solar flux and reflector efficiency to calculate the reactant temperature given the incoming temperature, pressure, and exchanger geometry. The receiver is a custom manufactured series of copper blocks with serpentine channels to increase its surface area and the residence time of the reactants to heat up to 550 °C. The subsystem model was validated using a heat exchanger developed at NASA Glenn Research Center (GRC). The solar thermal energy subsystem focuses on a solar concentrator concept with a heat exchanger to heat the reactants before entering the carbon formation reactor. The subsystem model assumes a fixed solar flux and reflector efficiency to calculate the reactant temperature given the incoming temperature, pressure, and exchanger geometry. The receiver is a custom manufactured series of copper blocks with serpentine channels to increase its surface area and the residence time of the reactants to heat up to 550 °C. The subsystem model was validated using a heat exchanger developed at NASA Glenn Research Center (GRC).

In situ Resource Utilization↗

Beam-water Interaction System for PFAS Treatment

Per- and polyfluoroalkyl substances (PFAS) are persistent environmental contaminants that resist conventional water treatment due to the strength of their carbon fluorine bonds. Electron-beam irradiation has shown potential for PFAS degradation; however, its effectiveness is limited by shallow energy penetration, restricting treatment to the upper region of the water surface. This project addresses this limitation through the design of a compact mixing chamber and recirculation system to enhance surface renewal and improve treatment efficiency. The system, constrained to approximately 10 cm 20 cm 20 cm, was developed using computer-aided design, computational fluid dynamics (CFD), and MATLAB-based hydraulic analysis to evaluate flow behavior, head loss, and pump compatibility. A perforated-baffle geometry and controlled flow range of 1 3 GPM were implemented to promote uniform mixing while maintaining a stable free surface for electron-beam exposure. Modeling results indicate improved flow distribution and reduced dead zones, supporting more consistent interaction between contaminated water and the beam. The final design enhances hydrodynamic performance within system constraints, contributing to scalable electron-beam water treatment technologies for improved PFAS degradation.

Ramos, Gerardo [Northern Illinois U.]↗

Latent heat thermal energy storage performance maps enabling fast & accurate building energy simulations

Thermal energy storage (TES) using phase change materials (PCMs) has gained attention as an effective approach to manage energy demand fluctuations and shift peak building loads. PCM embedded heat exchangers (PCM-HXs) offer high energy storage density and low temperature variation during phase change, being suitable for load-shifting applications. However, this component is typically evaluated using computationally expensive methods, which present significant challenges when the ultimate goal is to assess the performance of PCM-HX integrated thermal energy storage systems in the full building context. In this paper, we present a methodology to generate highly accurate and computationally efficient PCM-HX performance maps which can be easily integrated into building energy simulation tools to analyze the feasibility of space conditioning systems with latent heat PCM-based TES. The performance maps are generated using a computationally efficient PCM-HX simulation tool based on a Generalized Resistance-Capacitance Model (GRCM) which can simulate arbitrary PCM-HXs with high accuracy and significantly less computational effort compared to full CFD simulations. The methodology was verified for a case study considering a 5-ton (~17.5 kW) air-to-water heat pump-thermal energy storage system (HP-TES), which was co-simulated in Modelica for a DOE prototype small-office building in Vienna, Austria, using Spawn of EnergyPlus™. The TES performance maps provided accurate predictions of PCM-HX behavior when used as Modelica component, with deviations within 2-4% while also achieving at least 103 computational time reduction. Leveraging this faster prediction capability, four PCMs with different melting temperatures for cooling (12°C, 16°C) and heating (31°C, 36°C) were assessed to investigate their impact on system performance. This work highlights the importance of robust PCM-HX models for efficient and high-fidelity building-level simulations, presenting new opportunities for advanced control strategy development and parametric analysis of TES configurations in a computationally efficient manner

Modelica Building Simulations↗

Multi-Size Proppant Pumping Schedule of Hydraulic Fracturing: Application to a MP-PIC Model of Unconventional Reservoir for Enhanced Gas Production

Slickwater hydraulic fracturing is becoming a prevalent approach to economically recovering shale hydrocarbon. It is very important to understand the proppant’s transport behavior during slickwater hydraulic fracturing treatment for effective creation of a desired propped fracture geometry. The currently available models are either oversimplified or have been performed at limited length scales to avoid high computational requirements. Another limitation is that the currently available hydraulic fracturing simulators are developed using only single-sized proppant particles. Motivated by this, in this work, a computationally efficient, three-dimensional, multiphase particle-in-cell (MP-PIC) model was employed to simulate the multi-size proppant transport in a field-scale geometry using the Eulerian–Lagrangian framework. Instead of tracking each particle, groups of particles (called parcels) are tracked, which allows one to simulate the proppant transport in field-scale geometries at an affordable computational cost. Then, we found from our sensitivity study that pumping schedules significantly affect propped fracture surface area and average fracture conductivity, thereby influencing shale gas production. Motivated by these results, we propose an optimization framework using the MP-PIC model to design the multi-size proppant pumping schedule that maximizes shale gas production from unconventional reservoirs for given fracturing resources.

42 ENGINEERING↗

Quantification of Energy Savings and Demand Reduction for a Heat Pump Integrated with Thermal Energy Storage (Final Report)

To mitigate the variation in demand on the electric grid, thermal energy storage (TES) is an alternative to electric batteries or installing new peaking power plants. Stakeholders and policy makers across the United States have expressed interests in promoting TES, as demonstrated by the US Department of Energy’s Grid-Interactive Efficient Buildings program and the efforts of various state legislatures. However, the cost value provided by TES are unclear. If reliable cost benefits were determined, stakeholders would have a clearer picture of the financial returns that can be gained from their investment in TES. The study in this report is conducted by ORNL with collaboration with Emerson the Helix Innovation Center. In the first part of this report, EnergyPlus was used to perform whole-building simulations for two residential buildings in Indianapolis and Atlanta. The HVAC system in both buildings were equipped with phase change material TES. The TES tank was charged in off-peak hours and discharged in peak hours to perform load shifting. First, the economic value implied by existing time-of-use (TOU) rates offered by utility companies was analyzed via whole-building simulation. Second, existing demand reduction (DR) incentives sourced from 3 different electrical grid administrators (i.e., California, Texas, and New England region) were surveyed to determine their implied value. The study suggests that the traditional value analysis that focuses on ROI for the building owner significantly undervalues TES technology making economic viability difficult. A more comprehensive value analysis that includes peak demand management and deferred capital for peaking power plants shows that TES should be economically viable but here the value is greater for the utility and requires large market penetration and aggregation to fully realize the benefits. Therefore, to facilitate commercialization, new business models are needed that include a broader range of stakeholders and distribute the value of TES proportionally. In the 2 nd part of this project, the benefits of a novel phase change material (PCM) integrated heat pump configuration were evaluated via detailed component based simulation. A one-dimensional PCM heat exchanger model which discretizes the PCM tank and refrigerant tubes into small control volumes is developed. Each control volume can have different PCM temperatures, PCM properties, and heat transfer coefficients. The PCM tank is charged by a wrapped tank condenser and discharged by an internal refrigerant coil. The PCM heat exchanger model is integrated into DOE/ORNL Heat Pump Design Model for heat pump system simulation. To demonstrate the performance of the PCM integrated heat pump, a case study in Chicago was performed. A Time-of-Use utility structure-based control strategy is implemented to schedule the PCM tank charging and discharging mode switching. Compared with a conventional electric heat pump, the PCM integrated heat pump shows superior performance on load shifting and utility cost reduction. As a result, the proposed system demonstrates 24.6% utility saving for cooling application and 25.8% utility saving for heating application.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Measure Documentation: Boiler Replacement with Air-Source Heat Pump Boiler and Natural Gas Boiler Backup

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock (™) and ComStock (™) models over the past three years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each timestep. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on a single end-use savings shape measure - boiler replacement with air-source heat pump boiler with natural gas boiler backup. This measure replaces natural gas boilers for HVAC application by air-source heat pump boilers when applicable and use natural gas boiler backup when the heat pump boiler could not operate due to outdoor air conditions which are below its cutoff temperature. This measure helps to quantify the decarbonization as well as the energy savings potential from the replacement. The measure resulted higher savings in natural gas consumption compared to the increase in electricity consumption, with a ratio of 3. The total natural gas energy consumption was reduced by 41%, whereas the total electricity consumption was increased by 5.3%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Manufactured Home Equipment Sizing and Selection Tool

This tool is for use for manufactured homes built to the HUD Code (thermal provisions of the Manufactured Housing Construction and Safety Standards, Subpart F, Section §3280), including manufactured homes certified as ENERGY STAR® and DOE Efficient New Homes. It provides a simple look-up procedure to assist equipment specifiers, HVAC contractors, home installers, retailers, manufacturers, and electric utility staff. For new manufactured homes, it guides in selection of single speed heat pumps and air conditioners. For existing homes, it determines design conditions and nominal equipment size. The guidelines provide a simple but accurate procedure that reduces oversizing and its associated problems.

Source record↗

Infrared upconversion for astronomical applications

The performance of an upconversion system is examined for observation of astronomical sources in the low to middle IR spectral range. Theoretical values for the performance parameters of an upconversion system for astronomical observations are evaluated in terms of the conversion efficiencies, spectral resolution, field of view minimum detectable source brightness, and source flux. Experimental results of blackbody measurements and molecular absorption-spectrum measurements using a lithium niobate upconverter with an argon-ion laser as the pump are presented. Estimates are given of the expected optimum sensitivity of an upconversion device that may be built with presently available components.

Abbas, M. M.↗

Criteria for the evaluation of laser solar energy converter systems

Assuming that a parabolic insolation-collection mirror-based solar pumped laser has a collector and heat emitter whose weights are proportional to their areas, and that the weight of the laser is negligible by comparison, the output power/unit weight can be expressed in terms of the efficiencies and working temperatures of the system. This ratio appears to be several times higher for an IBr laser than for one operating on C3F7I, because the solar utilization efficiency is greater for the former despite its lower working temperature.

Harries, W. L.↗

Phase 1 Space Fission Propulsion Energy Source Design

Fission technology can enable rapid, affordable access to any point in the solar system. If fission propulsion systems are to be developed to their full potential; however, near-term customers must be identified and initial fission systems successfully developed, launched, and operated. Studies conducted in fiscal year 2001 (IISTP, 2001) show that fission electric propulsion (FEP) systems with a specific mass at or below 50 kg/kWjet could enhance or enable numerous robotic outer solar system missions of interest. At the required specific mass, it is possible to develop safe, affordable systems that meet mission requirements. To help select the system design to pursue, eight evaluation criteria were identified: system integration, safety, reliability, testability, specific mass, cost, schedule, and programmatic risk. A top-level comparison of four potential concepts was performed: a Testable, Passive, Redundant Reactor (TPRR), a Testable Multi-Cell In-Core Thermionic Reactor (TMCT), a Direct Gas Cooled Reactor (DGCR), and a Pumped Liquid Metal Reactor.(PLMR). Development of any of the four systems appears feasible. However, for power levels up to at least 500 kWt (enabling electric power levels of 125-175 kWe, given 25-35% power conversion efficiency) the TPRR has advantages related to several criteria and is competitive with respect to all. Hardware-based research and development has further increased confidence in the TPRR approach. Successful development and utilization of a "Phase I" fission electric propulsion system will enable advanced Phase 2 and Phase 3 systems capable of providing rapid, affordable access to any point in the solar system.

Houts, Mike↗

One-Joule-per-Pulse Q-Switched 2-micron Solid State Laser

Q-switched output of 1.1 J per pulse at 2-micron wavelength has been achieved in a diode pumped Ho:Tm:LuLF laser using a side-pumped rod configuration in a Master-Oscillator-Power-Amplifier (MOPA) architecture. This is the first time that a 2-micron laser has broken the Joule per pulse barrier for Q-switched operation. The total system efficiency reaches 5% and 6.2% for single and double pulse operation, respectively. The system produces excellent 1.4 times of transform limited beam quality.

Yu, Jirong↗

A novel shallow bore ground heat exchanger for ground source heat pump applications—Model development and validation

A novel ground heat exchanger design, the Underground Thermal Battery (UTB), was proposed as a low-cost alternative to the conventional vertical bore ground heat exchanger (VBGHE) for the application of ground source heat pumps (GSHPs). The UTB is designed to be installed in a shallow borehole (less than 6 m deep) and thus could cost much less than the conventional VBGHE, which usually is installed in vertical bores 60 m deep. By utilizing natural convection of water and phase change materials, the UTB tempers its temperature change in response to thermal loads, which helps improve the efficiency of GSHPs. A one-dimensional (1D) model of the UTB has been developed and validated with the measured performance data of a small-scale UTB, as well as the simulation results of a more detailed three dimensional (3D) numerical model, which accounts for both heat transfer and fluid dynamics in the UTB. Further, this 1D model is computationally much more efficient than the 3D model and thus can simulate the annual performance of the UTB with acceptable computation time. The 1D model has been used to evaluate the performance of the UTB so that it can be compared with the conventional VBGHE.

42 ENGINEERING↗

The Role of Fuels in Transforming Energy End-Use in Buildings and Industrial Processes

This book examines what role fuels have in the transformation of end-use in buildings and industrial processes. Energy efficient technologies are necessary to lower the carbon footprint for a transition towards clean energy in a sustainable manner. Efficient utilization of primary energy resources including renewables to support the current and future energy needs while targeting grid resiliency, energy and environmental security, at an affordable cost is of significant value. Analysis of configurations consisting of heat pumps, fuel driven thermal providers and power systems is presented. Sensitivity of electrical grid's carbon intensity towards carbon footprint in comparison with fuel driven technologies is necessary to recognize the true value proposition of currently available energy solutions for different end consumers. Similarly, the role of low carbon, zero carbon, and carbon negative fuels such as power to gas, power to liquid, hydrogen, biogas, etc. in conjunction with polygeneration technologies are discussed. Transformation of the primary energy resources from conventional fossil fuels to renewable fuels or electricity will have a significant impact on the overall carbon footprint of various end use sectors, including buildings. Hence, this book also examines two different scenarios focused on sensitivity of the pace of decarbonization of electrical grid and fuel supply on operational energy related carbon emissions.

Cheekatamarla, Praveen↗