Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “power gas simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

1,127 records · Page 63

Development of a Comprehensive Two-Phase Flow Database for the Validation of NEK-2P

Three-dimensional (3-D) two-phase Computational Fluid Dynamics (CFD) codes are emerging as a powerful and potentially practical tool for applications in which detailed local flow information is needed. However, two-phase flow models and associated closure relations are not well established for CFD applications, which is partly due to the lack of high-quality validation data. The main objective of this work is to develop a comprehensive database of two-phase flows that can be used to validate two-phase CFD codes such as NEK-2P. In this project, four advanced local measurement systems, including Particle Image Velocimetry and Planar Laser-Induced Fluorescence (PIV-PLIF), high-speed imaging, x-ray densitometry, and multi-sensor conductivity probe are employed to measure the local two-phase flow parameters of both gas and liquid phases. By combining these techniques, the local void fraction, bubble velocity, interfacial area concentration, bubble frequency, liquid velocity, turbulence intensity, etc., in various two-phase flow regimes can be obtained. These local measurement techniques are first used in a 25.4 mm circular pipe test section. Seven air-water two-phase flow conditions spanning the bubbly, slug, churn-turbulent, and annular flow regimes are measured in this facility. The obtained database contains the radial profiles of both gas- and liquid-phase parameters at three axial locations along the test section. The second facility used in this work contains a 30 mm × 10 mm rectangular test section, in which three two-phase flow and two single-phase flow conditions are measured. Two-dimensional distributions of local two-phase flow parameters in the cross-sectional plane are measured in this facility at three axial locations as well. A facility featuring a 3×3 electrically heated rod bundle is also designed and being constructed in this project. This facility is specially designed for optical measurements and is expected to provide high-quality boiling data in the future. Preliminary analyses have been performed for the data taken in the 25.4 mm circular pipe. Both center-peaked and wall-peaked void fraction profiles have been observed in the data depending on the two-phase flow conditions and/or developing lengths. The 1-D drift-flux model was evaluated with the newly obtained datasets, in which both gas- and liquid-phases data were directly measured. The distribution parameter model has been optimized based on a new void-profile classification method proposed in this study. The optimized drift-flux model shows a significant improvement in predicting both gas velocity and void fraction. The measured liquid-phase turbulence was used to benchmark Sato’s turbulence model considering the bubble-induced shear stress for the three tested bubbly flows. The benchmark results showed good agreement between the PIV measurements and model predictions. In the bubbly flows tested that have low void fractions less than 3%, the effect of the bubble-induced turbulence was found not significant. However, the bubble-induced shear stress becomes important with the increase of the void fraction. The Conjugate Heat Transfer (CHT) model was developed and implemented in NEK-2P. This model allows the coupled simulation of the solid domain and two-phase fluid domain, allowing the specification of realistic boundary conditions. The CHT implementation was verified first with non-boiling simulations. The predicted temperatures in the fluid domain were shown to be identical in simulations with or without the CHT model. The CHT model was then validated through simulations of three Becker benchmark CHF tests performed under both Dryout (DO) and Departure from Nucleate Boiling (DNB) conditions. Reasonably good agreement was obtained between calculated wall temperatures and corresponding experimental data.

42 ENGINEERING↗

High Temperature Erosion Modeling in Particle Based CSP Systems

1. Introduction. Wear and erosion damage of materials from solid particle and surface interactions is a major issue in various industries. Although more common in mining and oil and gas production, erosion is becoming a critical issue in renewable technologies as well such as particle based concentrated solar thermal power (CSP) systems. In particle based CSP systems, solid particles are used to absorb solar energy and as thermal storage. However, these particles may cause significant amount of wear to system components while through the system at high temperatures. This damage can be costly, and therefore, requires a greater understanding of solid particle erosion in CSP systems. Throughout the years, models and tools have been developed to predict and control erosion in industries such as oil and gas production. However, these erosion models and erosion prediction tools have been mainly developed based on erosion data for much higher velocities and lower temperatures, i.e. the operating conditions for which the existing models have been built are not pertinent to those expected in CSP system. It is known that erosion depends on many factors such as material properties, erodent particle properties, and particle impact speed and angle. However, the effect of temperature on erosion is not vastly investigated. In this work, a temperature-based correlation is introduced that will be used to modify the existing erosion models to predict erosion rates at velocities and temperatures relevant to Gen3 CSP systems. The existing models are first validated against erosion experiments run at low temperatures and low velocities. Subsequently, a temperature correction term is developed that can extend the existing models to high temperatures, based on the available experimental data showing the effect of temperature on impact erosion. 2. Erosion Models. Continuing sequence of impacts from solid particles on surfaces would result in loss of material due to mechanical interaction between solid surface and particles. Erosion equations have been developed to predict erosion under different conditions and erosion mechanism, including cutting and deformation erosion. These models are mainly either mechanistic, empirical, and semi-mechanistic models, when the latter combine the theory of the erosion mechanism and particle motion with the available experimental data. One of the first empirical correlation was introduced by American Petroleum Institute (API) Recommended Practice (RP) 14E [1]. This correlation was very conservative, and several improved empirical and semi-mechanistic equations were developed in the years following. More recently, the models introduced by Erosion/Corrosion Research Center (E/CRC) at the University of Tulsa and Arabnejad. et al. [2] are frequently used in the literature and industry, as they account for many parameters affecting erosion including particle impact speed and angle, material density and hardness, and particle size and shape. However, both these models were developed based on data at relatively high velocities and also do not take into account any mechanical changes in material associated with thermal cycling at high temperatures. 3. Erosion Prediction at High Temperatures. In this work, the accuracy of Arabnejad et al. model and E/CRC model is investigated to predict impact erosion at conditions relevant to Gen3 CSP systems. Two significant deviations expected in Gen3 systems compared to operating conditions used to build these models are particle impact velocities and system temperature. As a first step, the performance of these models was validated at low velocities and temperatures. Impact erosion experiments were conducted on SS316 coupons using HSP 40/70 ceramic particles. Assuming particle rate of 1 kg/s/m, 0.0254 m of particle curtain thickness, and particle velocity of 1.5 m/s in the system, an overall erosion of 0.59 mm/year was calculated. The experimental results were subsequently compared to those from computational simulations and erosion of 0.47 mm/year was obtained using the Arabnejad et al. model. The results indicated that the models work well at low velocities and low temperature conditions. To account for temperature effect, a mathematical correlation was developed using data published by DUCOM [3] for Inconel 600 eroded by alumina particles at high velocities. The correlation was applied to both Arabnejad et. al model and the E/CRC model. The prediction results from these modified models were within 20% of this experimental data. Predictions of of erosion by the modified E/CRC model at three different temperatures are made. Similar to the calculation at low temperature, a typical CSP system with 1 kg/s/m of particle flow rate per unit length of the particle curtain and a curtain thickness of 0.0254 m is assumed. The annual thickness loss calculations were run for different particle impact velocities, assuming a uniform particle impact area equal to the cross-sectional area of the curtain (particle-particle interactions and dispersion of particles are not considered in obtaining the results). It is observed that erosion increases exponentially as temperature increases. Furthermore, it is also noted that, erosion changes non-linearly with impact velocity. Currently, experiments are also being conducted to measure erosion of SS316 at 800 ºC with HSP 40/70 particles at low impact velocities. We expect to use the results from high temperature testing to further improve the temperature correlation function. Similar models are also being developed for abrasion erosion resulting from particle sliding along the surfaces as well as attrition from particle to particle and particle to surface interactions. References. [1] Institute, A. P. (1991). API Recommended Practice for Design and Installation of Offshore Production Platform Piping System, API RP 14E. [2] Arabnejad, H., Mansouri, A., Shirazi, S. A., and McLaury, B. S. (2015a). Development of mechanistic erosion equation for solid particles. Wear, 332–333, 1044–1050. http://doi.org/10.1016/j.wear.2015.01.031. [3] https://ducom.com/high-temperature-erosion-evaluating-sample-wear/

14 SOLAR ENERGY↗

Roughrider Carbon Storage Hub (Final Report)

The Roughrider Carbon Storage Hub was a 2-year project (October 2023 – September 2025) conducted by the Energy & Environmental Research Center (EERC) focused on advancing the feasibility of a commercial-scale carbon dioxide (CO 2 ) geologic storage hub in McKenzie County, North Dakota. The project’s objective was to investigate the potential that stacked storage complexes (multiple deep saline formations) can safely and economically store at least 50 million tonnes of CO 2 within 30 years. The captured CO 2 would be sourced from industrial emitters including project partner ONEOK, Inc.’s gas-processing plants and a planned gas-to-liquids facility. Drilling of the Roughrider 1 stratigraphic test well (14,979-ft total depth) was completed in November 2024. The wellbore intersected four candidate storage formations: Inyan Kara, Broom Creek, Mission Canyon, and Black Island–Deadwood. Operational challenges, including a stuck drill string, were resolved without long-term impact. A comprehensive logging and coring program was conducted, followed by successful well abandonment and site reclamation. Over 660 ft of 4-in. whole core was retrieved. Core plug samples were processed and analyzed for petrophysical and geochemical properties. Results confirmed promising porosity and permeability in the Inyan Kara and Broom Creek Formations and removal of the Mission Canyon and Black Island–Deadwood horizons from further investigation. Data derived from the logging and coring program were used to improve initial geologic models built from legacy data. CO 2 injection simulations showed that the Inyan Kara alone can feasibly store the target mass of CO 2 . Because of subtle differences in geologic structure and porosity trends between the formations, a stacked storage scenario using the Broom Creek and Inyan Kara Formations resulted in a larger overall plume area than using the Inyan Kara alone. Preliminary CO 2 pipeline routes from the industrial sources were mapped utilizing existing rights of way and evaluated for capacity and cost using U.S. Department of Energy Office of Fossil Energy and Carbon Management/National Energy Technology Laboratory models and U.S. Environmental Protection Agency emissions data. Integrating capture, transport, and storage cost estimates with policy incentives (e.g., 45Q credits) provided a total cost-per-ton analysis. Results indicate that the small scale of the volumes to be transported over the cumulative large distances does not support the project’s financial viability. However, the groundwork laid during this project from geological, regulatory, and social perspectives positions the Roughrider hub site as a promising candidate for commercial carbon storage in North Dakota, especially if the economy of scale is introduced for CO 2 transportation to the hub site.

01 COAL, LIGNITE, AND PEAT↗

Modeling and Simulation of Tank Pressure Control using Zero-Boil Off Active Thermal Control for LOXSAT Technology Demonstration Mission

To-date, research and modeling of cryogenic fluid management technologies (CFM) for spaceflight has been limited to ground tests, short-duration zero-g simulations (e.g. drop towers), and small-scale experiments on-orbit. There has not been a large-scale flight demonstration of a flight-like system. As future NASA missions to take humans further from Earth will require large, in-space cryogenic propulsion vehicles, it is imperative to begin collecting flight data for these systems to accurately model and design future vehicles. To meet this goal, NASA awarded tipping point technology demonstration awards to Eta Space, Lockheed Martin, Space Exploration Technologies (SpaceX), and United Launch Alliance (ULA) to demonstrate on-orbit storage and transfer of cryogenic propellant. For its award, Eta Space is developing LOXSAT-1. It is a small satellite that will be launched on a Rocket Lab Electron rocket. The spacecraft consists of a Rocket Lab Photon spacecraft bus with a primary payload of a spherical liquid oxygen (LOX) storage tank with thermodynamic control systems. The primary objective of the mission is to demonstrate zero-boil-off storage of liquid oxygen. To accomplish this objective, the payload is equipped with an active thermal control system fluid loop that consists of propellant management device (PMD), positive-displacement pump, heat exchanger connected to a cryocooler, and a spray bar mixing injector. When the fluid loop is operating, fluid is drawn from the tank by the PMD and pumped through the heat exchanger, lowering the fluid temperature below the fluid temperature in the tank. This subcooled liquid is then injected back into the tank through the spray bar. The subcooled injected liquid has two effects. If it is sprayed into the ullage space, the injected liquid will form into jets or droplets and exchange heat with the ullage gas. This will cool and condense the gas, reducing the pressure in the tank. Additionally, the liquid that is not sprayed through the ullage, as well as any remaining liquid spray from the ullage, will rejoin the liquid mass of the tank, lowering the bulk temperature of the liquid. These combines effects provide for zero-boil off pressure control by lowering the tank pressure and the liquid saturation pressure simultaneously, ensuring the liquid stays subcooled. To model these complex mechanics and predict the performance of the active thermal control system, NASA is providing Eta Space with 3 parallel models of the tank. The approach of providing 3 different models allows for cross-checking and comparisons between the three to better understand how different modeling assumptions and selection semi-empirical factors affects the modeling result. Additionally, developing 3 models provides three different schemes for numerical simulation, providing confidence that results depict real physical phenomenon and not numerical quirks of the program. Within the tank thermodynamics, there are two primary areas of heat transfer we concern ourselves with: the heat transfer between the ullage space and the droplet spray, and between the ullage space and bulk liquid. For the droplet heat transfer, there are multiple sets of assumptions that can be made and correlations that can be used. Currently, two working models - the TankSIM model and Easy5 model – provide for an overview of the different approaches available. The TankSIM model and Easy5 model use two different models for droplet heating and evaporation that illustrate how the models use different types of mechanisms to arrive at the same answer. For the TankSIM model, droplets are treated as spheres of constant radius. Heat is transferred from the ullage to the droplet and warms the droplet until it reaches saturation, then the droplet begins evaporating and reducing its radius and mass. To calculate the heat transfer coefficient between the droplet and ullage, the Ranz-Marshall correlation is used. To determine the number of droplets in the ullage, a resident mass approach is used. This approach averages the number of droplets such that residuals at the start-up and shut-off of the spray bar cancel out. This same approach is used in the Easy5 model. The GFSSP model implements a linked list to track individual droplet “nodes” within the model. For the Easy5 model, the droplet is assumed to have an interface at a temperature equal to the saturation temperature corresponding to the pressure of the gas phase. The heat transfer from the gas to the interface and the interface to the droplet bulk is then calculated, and the net mass transfer between the droplet and interface is determined by performing an energy balance across the interface. For the gas side of the interface, the Ranz-Marshall correlation is used. For the liquid side of the interface, a variety of correlations were tried, including Kronig and Brink (1950) and effective conductivity models. As a result of these assumptions, the Easy5 model currently predicts faster depressurization, as at saturated vapor conditions, the heat transfer coeffect on the liquid side for the Easy5 model is greater than the heat transfer coefficient predicted by Ranz-Marshall used in the TankSIM code. This greater heat flux translates into faster condensation of the saturated ullage gas. At the bulk liquid to ullage interface, the models are in much closer agreement. Both models model the ullage as a sphere centered within the bulk liquid in the tank, and both use the energy-jumping boundary condition to model heat and mass transfer across the interface. There are slight differences in how the interface temperature is calculated, however. The Easy5 model assumes the temperature of the interface is equal to the saturation temperature associated with the pressure of the gas phase. The TankSIM model calculates this temperature with Alabovskii’s equation, which provides a correction factor for interface temperatures. Analysis tasks are focused on determining rates of depressurization within the tank during active cooling operation. To maintain net positive suction head at the pump inlet, the tank pressure cannot fall faster than the saturation pressure associated with the temperature of the bulk liquid. Additionally, there is interest in analyzing the performance of the loop at different pump speeds and cryocooler input powers. Adjusting the flowrate affects both the performance of the heat exchanger between the cryocooler and pumped liquid, and the heat transfer between the droplet spray and the ullage. Ideally, a pump speed and cryocooler power can be selected that will allow the tank to operate in zero-boil-off mode with a very narrow range of storage pressure.

Cameron J. Hines↗

Modeling and Simulation of Tank Pressure Control using Zero-Boil Off Active Thermal Control for LOXSAT Technology Demonstration Mission

To-date, research and modeling of cryogenic fluid management technologies (CFM) for spaceflight has been limited to ground tests, short-duration zero-g simulations (e.g. drop towers), and small-scale experiments on-orbit. There has not been a large-scale flight demonstration of a flight-like system. As future NASA missions to take humans further from Earth will require large, in-space cryogenic propulsion vehicles, it is imperative to begin collecting flight data for these systems to accurately model and design future vehicles. To meet this goal, NASA awarded tipping point technology demonstration awards to Eta Space, Lockheed Martin, Space Exploration Technologies (SpaceX), and United Launch Alliance (ULA) to demonstrate on-orbit storage and transfer of cryogenic propellant. For its award, Eta Space is developing LOXSAT-1. It is a small satellite that will be launched on a Rocket Lab Electron rocket. The spacecraft consists of a Rocket Lab Photon spacecraft bus with a primary payload of a spherical liquid oxygen (LOX) storage tank with thermodynamic control systems. The primary objective of the mission is to demonstrate zero-boil-off storage of liquid oxygen. To accomplish this objective, the payload is equipped with an active thermal control system fluid loop that consists of propellant management device (PMD), positive-displacement pump, heat exchanger connected to a cryocooler, and a spray bar mixing injector. When the fluid loop is operating, fluid is drawn from the tank by the PMD and pumped through the heat exchanger, lowering the fluid temperature below the fluid temperature in the tank. This subcooled liquid is then injected back into the tank through the spray bar. The subcooled injected liquid has two effects. If it is sprayed into the ullage space, the injected liquid will form into jets or droplets and exchange heat with the ullage gas. This will cool and condense the gas, reducing the pressure in the tank. Additionally, the liquid that is not sprayed through the ullage, as well as any remaining liquid spray from the ullage, will rejoin the liquid mass of the tank, lowering the bulk temperature of the liquid. These combines effects provide for zero-boil off pressure control by lowering the tank pressure and the liquid saturation pressure simultaneously, ensuring the liquid stays subcooled. To model these complex mechanics and predict the performance of the active thermal control system, NASA is providing Eta Space with 3 parallel models of the tank. The approach of providing 3 different models allows for cross-checking and comparisons between the three to better understand how different modeling assumptions and selection semi-empirical factors affects the modeling result. Additionally, developing 3 models provides three different schemes for numerical simulation, providing confidence that results depict real physical phenomenon and not numerical quirks of the program. Within the tank thermodynamics, there are two primary areas of heat transfer we concern ourselves with: the heat transfer between the ullage space and the droplet spray, and between the ullage space and bulk liquid. For the droplet heat transfer, there are multiple sets of assumptions that can be made and correlations that can be used. Currently, two working models - the TankSIM model and Easy5 model – provide for an overview of the different approaches available. The TankSIM model and Easy5 model use two different models for droplet heating and evaporation that illustrate how the models use different types of mechanisms to arrive at the same answer. For the TankSIM model, droplets are treated as spheres of constant radius. Heat is transferred from the ullage to the droplet and warms the droplet until it reaches saturation, then the droplet begins evaporating and reducing its radius and mass. To calculate the heat transfer coefficient between the droplet and ullage, the Ranz-Marshall correlation is used. To determine the number of droplets in the ullage, a resident mass approach is used. This approach averages the number of droplets such that residuals at the start-up and shut-off of the spray bar cancel out. This same approach is used in the Easy5 model. The GFSSP model implements a linked list to track individual droplet “nodes” within the model. For the Easy5 model, the droplet is assumed to have an interface at a temperature equal to the saturation temperature corresponding to the pressure of the gas phase. The heat transfer from the gas to the interface and the interface to the droplet bulk is then calculated, and the net mass transfer between the droplet and interface is determined by performing an energy balance across the interface. For the gas side of the interface, the Ranz-Marshall correlation is used. For the liquid side of the interface, a variety of correlations were tried, including Kronig and Brink (1950) and effective conductivity models. As a result of these assumptions, the Easy5 model currently predicts faster depressurization, as at saturated vapor conditions, the heat transfer coeffect on the liquid side for the Easy5 model is greater than the heat transfer coefficient predicted by Ranz-Marshall used in the TankSIM code. This greater heat flux translates into faster condensation of the saturated ullage gas. At the bulk liquid to ullage interface, the models are in much closer agreement. Both models model the ullage as a sphere centered within the bulk liquid in the tank, and both use the energy-jumping boundary condition to model heat and mass transfer across the interface. There are slight differences in how the interface temperature is calculated, however. The Easy5 model assumes the temperature of the interface is equal to the saturation temperature associated with the pressure of the gas phase. The TankSIM model calculates this temperature with Alabovskii’s equation, which provides a correction factor for interface temperatures. Analysis tasks are focused on determining rates of depressurization within the tank during active cooling operation. To maintain net positive suction head at the pump inlet, the tank pressure cannot fall faster than the saturation pressure associated with the temperature of the bulk liquid. Additionally, there is interest in analyzing the performance of the loop at different pump speeds and cryocooler input powers. Adjusting the flowrate affects both the performance of the heat exchanger between the cryocooler and pumped liquid, and the heat transfer between the droplet spray and the ullage. Ideally, a pump speed and cryocooler power can be selected that will allow the tank to operate in zero-boil-off mode with a very narrow range of storage pressure.

zero boil-off↗

Modeling and Simulation of Tank Pressure Control using Zero-Boil Off Active Thermal Control for LOXSAT Technology Demonstration Mission

To-date, research and modeling of cryogenic fluid management technologies (CFM) for spaceflight has been limited to ground tests, short-duration zero-g simulations (e.g. drop towers), and small-scale experiments on-orbit. There has not been a large-scale flight demonstration of a flight-like system. As future NASA missions to take humans further from Earth will require large, in-space cryogenic propulsion vehicles, it is imperative to begin collecting flight data for these systems to accurately model and design future vehicles. To meet this goal, NASA awarded tipping point technology demonstration awards to Eta Space, Lockheed Martin, Space Exploration Technologies (SpaceX), and United Launch Alliance (ULA) to demonstrate on-orbit storage and transfer of cryogenic propellant. For its award, Eta Space is developing LOXSAT-1. It is a small satellite that will be launched on a Rocket Lab Electron rocket. The spacecraft consists of a Rocket Lab Photon spacecraft bus with a primary payload of a spherical liquid oxygen (LOX) storage tank with thermodynamic control systems. The primary objective of the mission is to demonstrate zero-boil-off storage of liquid oxygen. To accomplish this objective, the payload is equipped with an active thermal control system fluid loop that consists of propellant management device (PMD), positive-displacement pump, heat exchanger connected to a cryocooler, and a spray bar mixing injector. When the fluid loop is operating, fluid is drawn from the tank by the PMD and pumped through the heat exchanger, lowering the fluid temperature below the fluid temperature in the tank. This subcooled liquid is then injected back into the tank through the spray bar. The subcooled injected liquid has two effects. If it is sprayed into the ullage space, the injected liquid will form into jets or droplets and exchange heat with the ullage gas. This will cool and condense the gas, reducing the pressure in the tank. Additionally, the liquid that is not sprayed through the ullage, as well as any remaining liquid spray from the ullage, will rejoin the liquid mass of the tank, lowering the bulk temperature of the liquid. These combines effects provide for zero-boil off pressure control by lowering the tank pressure and the liquid saturation pressure simultaneously, ensuring the liquid stays subcooled. To model these complex mechanics and predict the performance of the active thermal control system, NASA is providing Eta Space with 3 parallel models of the tank. The approach of providing 3 different models allows for cross-checking and comparisons between the three to better understand how different modeling assumptions and selection semi-empirical factors affects the modeling result. Additionally, developing 3 models provides three different schemes for numerical simulation, providing confidence that results depict real physical phenomenon and not numerical quirks of the program. Within the tank thermodynamics, there are two primary areas of heat transfer we concern ourselves with: the heat transfer between the ullage space and the droplet spray, and between the ullage space and bulk liquid. For the droplet heat transfer, there are multiple sets of assumptions that can be made and correlations that can be used. Currently, two working models - the TankSIM model and Easy5 model – provide for an overview of the different approaches available. The TankSIM model and Easy5 model use two different models for droplet heating and evaporation that illustrate how the models use different types of mechanisms to arrive at the same answer. For the TankSIM model, droplets are treated as spheres of constant radius. Heat is transferred from the ullage to the droplet and warms the droplet until it reaches saturation, then the droplet begins evaporating and reducing its radius and mass. To calculate the heat transfer coefficient between the droplet and ullage, the Ranz-Marshall correlation is used. To determine the number of droplets in the ullage, a resident mass approach is used. This approach averages the number of droplets such that residuals at the start-up and shut-off of the spray bar cancel out. This same approach is used in the Easy5 model. The GFSSP model implements a linked list to track individual droplet “nodes” within the model. For the Easy5 model, the droplet is assumed to have an interface at a temperature equal to the saturation temperature corresponding to the pressure of the gas phase. The heat transfer from the gas to the interface and the interface to the droplet bulk is then calculated, and the net mass transfer between the droplet and interface is determined by performing an energy balance across the interface. For the gas side of the interface, the Ranz-Marshall correlation is used. For the liquid side of the interface, a variety of correlations were tried, including Kronig and Brink (1950) and effective conductivity models. As a result of these assumptions, the Easy5 model currently predicts faster depressurization, as at saturated vapor conditions, the heat transfer coeffect on the liquid side for the Easy5 model is greater than the heat transfer coefficient predicted by Ranz-Marshall used in the TankSIM code. This greater heat flux translates into faster condensation of the saturated ullage gas. At the bulk liquid to ullage interface, the models are in much closer agreement. Both models model the ullage as a sphere centered within the bulk liquid in the tank, and both use the energy-jumping boundary condition to model heat and mass transfer across the interface. There are slight differences in how the interface temperature is calculated, however. The Easy5 model assumes the temperature of the interface is equal to the saturation temperature associated with the pressure of the gas phase. The TankSIM model calculates this temperature with Alabovskii’s equation, which provides a correction factor for interface temperatures. Analysis tasks are focused on determining rates of depressurization within the tank during active cooling operation. To maintain net positive suction head at the pump inlet, the tank pressure cannot fall faster than the saturation pressure associated with the temperature of the bulk liquid. Additionally, there is interest in analyzing the performance of the loop at different pump speeds and cryocooler input powers. Adjusting the flowrate affects both the performance of the heat exchanger between the cryocooler and pumped liquid, and the heat transfer between the droplet spray and the ullage. Ideally, a pump speed and cryocooler power can be selected that will allow the tank to operate in zero-boil-off mode with a very narrow range of storage pressure.

zero boil-off↗

Modeling and Simulation of Tank Pressure Control using Zero-Boiloff Active Thermal Control for LOXSAT Technology Demonstration Mission

To-date, research and modeling of cryogenic fluid management technologies (CFM) for spaceflight has been limited to ground tests, short-duration zero-g simulations (e.g. drop towers), and small-scale experiments on-orbit. There has not been a large-scale flight demonstration of a flight-like system. As future NASA missions to take humans further from Earth will require large, in-space cryogenic propulsion vehicles, it is imperative to begin collecting flight data for these systems to accurately model and design future vehicles. To meet this goal, NASA awarded tipping point technology demonstration awards to Eta Space, Lockheed Martin, Space Exploration Technologies (SpaceX), and United Launch Alliance (ULA) to demonstrate on-orbit storage and transfer of cryogenic propellant. For its award, Eta Space is developing LOXSAT-1. It is a small satellite that will be launched on a Rocket Lab Electron rocket. The spacecraft consists of a Rocket Lab Photon spacecraft bus with a primary payload of a spherical liquid oxygen (LOX) storage tank with thermodynamic control systems. The primary objective of the mission is to demonstrate zero-boil-off storage of liquid oxygen. To accomplish this objective, the payload is equipped with an active thermal control system fluid loop that consists of propellant management device (PMD), positive-displacement pump, heat exchanger connected to a cryocooler, and a spray bar mixing injector. When the fluid loop is operating, fluid is drawn from the tank by the PMD and pumped through the heat exchanger, lowering the fluid temperature below the fluid temperature in the tank. This subcooled liquid is then injected back into the tank through the spray bar. The subcooled injected liquid has two effects. If it is sprayed into the ullage space, the injected liquid will form into jets or droplets and exchange heat with the ullage gas. This will cool and condense the gas, reducing the pressure in the tank. Additionally, the liquid that is not sprayed through the ullage, as well as any remaining liquid spray from the ullage, will rejoin the liquid mass of the tank, lowering the bulk temperature of the liquid. These combines effects provide for zero-boil off pressure control by lowering the tank pressure and the liquid saturation pressure simultaneously, ensuring the liquid stays subcooled. To model these complex mechanics and predict the performance of the active thermal control system, NASA is providing Eta Space with 3 parallel models of the tank. The approach of providing 3 different models allows for cross-checking and comparisons between the three to better understand how different modeling assumptions and selection semi-empirical factors affects the modeling result. Additionally, developing 3 models provides three different schemes for numerical simulation, providing confidence that results depict real physical phenomenon and not numerical quirks of the program. Within the tank thermodynamics, there are two primary areas of heat transfer we concern ourselves with: the heat transfer between the ullage space and the droplet spray, and between the ullage space and bulk liquid. For the droplet heat transfer, there are multiple sets of assumptions that can be made and correlations that can be used. Currently, two working models - the TankSIM model and Easy5 model – provide for an overview of the different approaches available. The TankSIM model and Easy5 model use two different models for droplet heating and evaporation that illustrate how the models use different types of mechanisms to arrive at the same answer. For the TankSIM model, droplets are treated as spheres of constant radius. Heat is transferred from the ullage to the droplet and warms the droplet until it reaches saturation, then the droplet begins evaporating and reducing its radius and mass. To calculate the heat transfer coefficient between the droplet and ullage, the Ranz-Marshall correlation is used. To determine the number of droplets in the ullage, a resident mass approach is used. This approach averages the number of droplets such that residuals at the start-up and shut-off of the spray bar cancel out. This same approach is used in the Easy5 model. The GFSSP model implements a linked list to track individual droplet “nodes” within the model. For the Easy5 model, the droplet is assumed to have an interface at a temperature equal to the saturation temperature corresponding to the pressure of the gas phase. The heat transfer from the gas to the interface and the interface to the droplet bulk is then calculated, and the net mass transfer between the droplet and interface is determined by performing an energy balance across the interface. For the gas side of the interface, the Ranz-Marshall correlation is used. For the liquid side of the interface, a variety of correlations were tried, including Kronig and Brink (1950) and effective conductivity models. As a result of these assumptions, the Easy5 model currently predicts faster depressurization, as at saturated vapor conditions, the heat transfer coeffect on the liquid side for the Easy5 model is greater than the heat transfer coefficient predicted by Ranz-Marshall used in the TankSIM code. This greater heat flux translates into faster condensation of the saturated ullage gas. At the bulk liquid to ullage interface, the models are in much closer agreement. Both models model the ullage as a sphere centered within the bulk liquid in the tank, and both use the energy-jumping boundary condition to model heat and mass transfer across the interface. There are slight differences in how the interface temperature is calculated, however. The Easy5 model assumes the temperature of the interface is equal to the saturation temperature associated with the pressure of the gas phase. The TankSIM model calculates this temperature with Alabovskii’s equation, which provides a correction factor for interface temperatures. Analysis tasks are focused on determining rates of depressurization within the tank during active cooling operation. To maintain net positive suction head at the pump inlet, the tank pressure cannot fall faster than the saturation pressure associated with the temperature of the bulk liquid. Additionally, there is interest in analyzing the performance of the loop at different pump speeds and cryocooler input powers. Adjusting the flowrate affects both the performance of the heat exchanger between the cryocooler and pumped liquid, and the heat transfer between the droplet spray and the ullage. Ideally, a pump speed and cryocooler power can be selected that will allow the tank to operate in zero-boil-off mode with a very narrow range of storage pressure.

zero boil-off↗

Bench-Scale Testing of a High Efficiency, Ultra-Compact Process for Pre-Combustion CO 2 Capture (Final Report)

The overarching objective of this bench-scale study is to field-validate the technical feasibility of a membrane- and adsorption-enhanced water gas shift (WGS) reaction process that employs a carbon molecular sieve (CMS) membrane reactor (MR) followed by an adsorption reactor (AR) for pre-combustion CO 2 capture while demonstrating progress towards achievement of the overall performance goals of CO 2 capture with 95% CO 2 purity at a cost of electricity (COE) of 30% less than the baseline capture approaches. The main goal of this bench-scale project is to advance the proposed MR-AR transformative CO 2 capture technology to a sufficient maturity level so that our present industrial partners (M&PT and Worley) can potentially adapt the technology for further small pilot-scale testing. The project began at TRL 4, as the system prototype had already been validated in the laboratory on simulated syngas (as part of project DE-FE0026423). The project ended at TRL 5, via scaling-up of the prototype system and testing it on actual syngas at a host site (CAER at the University of Kentucky (UKy)). The project was carried-out in two different phases: In Phase I (during BP1 of the project), the team designed, constructed, and assembled the bench-scale experimental MR-AR system, prepared the membranes, adsorbents, and catalysts, tested the bench-scale unit with simulated syngas to validate functionality, and prepared a preliminary TEA of the technology. In Phase II (during BP2 of the project), the team installed the unit at the test site at the UKy site and completed all utility connections and hookups, field-tested the novel MR-AR process in the bench-scale system using real syngas, collected and analyzed experimental data, and completed a detailed TEA of the technology. A key aim of the project was to identify and address the technical and process risks and to generate information to advance the technology to the next stage of development. All project milestones and success criteria were met. Specifically, the team: (i) designed, constructed and assembled a bench scale system that handled 1 – 5 scfm syngas and tested its functionality with simulated syngas; (ii) prepared high performance CMS membrane tubes (ID: 3.5 mm, OD: 5.7 mm, 30” long) that meet the target H 2 permeance ( > 1 m 3 /(m 2 .hr.bar) or (> 370.3 GPU)) and a target H 2 /CO selectivity >80 at the relevant temperature (up to 300oC) and pressure conditions (up to 25 bar) with a <10% decline in performance over each 250 hr. testing period (iii) procured commercial sour-shift catalyst in sufficient quantity and prepared up to 10 kg of pelletized adsorbent for use at relevant conditions (250oC 2.5wt.% and target sorbent attrition rate < 0.2; (iv) installed the bench-scale unit at the test site (UKy) and tested the MR-AR technology using real syngas for over 250 hr. for both static and flow experiments; (v) updated the TEA analysis based on bench-scale data and met CO 2 capture goals of 95% CO 2 purity at a cost of electricity 30% less than baseline capture approaches. The CMS membranes, HTC adsorbents and catalysts employed all exhibited very robust and stable performance during the long-term run (over a >250 hr live syngas run). Furthermore, the proposed MR-AR IGCC system achieved a LCOE with a N 2 sale price of $\$$ 30/ton, with N 2 compression (no N 2 compression) of 101.2 $\$$/MWh (95.3 $\$$/MWh), which represents a 29.8% (33.9%) LCOE reduction in the baseline IGCC with carbon capture of 144.2 $\$$/MWh. The proposed MR-AR IGCC delivers a CO 2 capture cost of 44.8 $\$$/tonne (39.9 $\$$/tonne) vs 98.1 $\$$/tonne of the baseline capture case and a net power production of 586 MWe (623 MWe) vs 556 MWe of the baseline capture case.

01 COAL, LIGNITE, AND PEAT↗

A Process with Decoupled Absorber Kinetics and Solvent Regeneration through Membrane Dewatering and In-Column Heat Transfer (Final Report)

This report summarizes the work conducted on project DE-FE0031604 where University of Kentucky Center for Applied Energy (UK CAER) has validated its intensified CO 2 capture process through substantial enhancements to the kinetics of the absorption process and energy reductions by absorber temperature profile modification, dewatering and heat integration technologies for achieving significant capital and operating cost reductions. To address DOE’s objective of improving post-combustion CO 2 capture technology and reducing associated cost, UK CAER employed an intensified process which combined three key aspects targeted at overcoming inherent limitations or barriers in the conventional CO 2 capture and desorption process. The process designed to be independent of the type of solvent used, included (1) the use of 3-D printed two-channel structured packing material to control the temperature profile and increase the CO 2 absorption rate in the absorber, (2) a zeolite membrane dewatering unit for dewatering of the carbon-rich solvent to decouple solvent concentration needs for CO 2 absorption and desorption, and (3) a rich-split feed with two-phase flow heat transfer prior to the stripper that provided a secondary point of vapor generation to provide energy savings in steam extraction and solvent regeneration. The project was executed over two budget periods. This involved testing of individual process components which included the advanced heat transfer packing and the dewatering membrane on UK CAER’s 30 liter per minute (L/min) CO 2 (3” Column) capture bench unit with simulated flue gas in the first budget period. Subsequent scaled-up testing of these components together with the split-feed configuration were also tested in UK CAER’s 0.1 MWth CO 2 capture unit with coal-derived flue gas in the second-budget period. Long term studies were done during this period to assess process and solvent performance over extended duration. Project partners Lawrence Livermore National Laboratory (LLNL) and Media & Process Technology (MPT) led the development efforts for the advanced packing material and dewatering membrane respectively. Data from the long term testing was used as input for an environmental, health and safety (EH&S) assessment for the process and scaled technology performed by ALL4 LLC. Trimeric Corporation also completed a techno-economic analysis (TEA) for the UK CAER technology which was compared to the DOE reference Case B12B. Tests on the 3” column capture unit showed that the advanced heat transfer packing could be used to lower the bulge temperature in the absorber, and this was also proven in the scaled testing in the 0.1 MWth CO 2 capture unit. The bulge temperature could be lowered by >10 °C, changing the temperature profile in the absorber, and showed potential to enhance absorption with the ability to tailor the profile to provide conditions suitable for a solvent’s properties and kinetics. Conditions for short term evaluation of a 19” zeolite dewatering membrane on the 3” column capture unit yielded desirable fluxes and sustained rejection rates of >80%. However, for the scaled testing of six membrane modules consisting of 21 parts of 31-inch-long membrane tubes in each bundle (surface area 0.3 m 2 ), over a more extended duration, similar rejection rates could not be achieved. With the split-feed of the rich stream to the stripper, improved heat recovery minimized waste heat exiting the top of the stripper. The stripper exhaust temperatures could be reduced by >10 °C; reducing the amount of water vaporization contributed to lowering the regeneration energy by ~ 15%. The energy benefit could be sustained from the long term monitoring of the solvent performance. The solvent properties were not significantly impacted over the long-term operations. The benefits of the UK CAER process demonstrated experimentally were mostly validated from the TEA comparing a commercial scale application of the technology to DOE reference Case B12B. The cost of CO 2 capture for the UK CAER technology was estimated to be ~$34.97/tonne of CO 2 captured; a reduction of 23% compared to Case B12B. The increase in cost of electricity was also shown to be 16% lower than that of Case B12B. The total parasitic demand was also shown to be 11% lower. The key drivers for the benefits are a result of the process intensification approaches employed in the UK CAER technology for enhanced solvent performance, effective heat recovery and improved energy performance. The EH&S assessment did not find any major environmental concerns or barriers to the full scale implementation of the technology.

20 FOSSIL-FUELED POWER PLANTS↗

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER↗

Winds, Water Budgets and Stable Isotopes in Tropical Cyclones using TRMM and QUICKSCAT

Water vapor is the most abundant greenhouse gas in the atmosphere. Changes in its concentration and distribution are controlled by the hydrologic cycle. Because of its capacity to absorb and emit long wave radiation, release latent heat during condensation in storms and reflect short wave radiation when clouds form it has a major impact on Global climate change. The stable isotope ratios of water are H20 H2l6O and H0 H2l6O. These ratios change whenever water undergoes a phase change. They also change in both rain and water vapor whenever an air parcel is exposed to rain. In addition the relative changes in the two ratios differ as a &nction of the relative humidity. In short, the stable isotope ratios in water vapor in the atmosphere contain an integrated history of the processes affecting the concentration and distribution of water vapor in the atmosphere. Therefore the measurement and interpretation of changes in these stable isotope ratios are a powerful tool matched by no other method in tracing the transport history of water in the atmosphere. Our initial studies under this grant focused on the changes of the stable isotope ratios of precipitation and water vapor in tropical cyclones. The changes in time and space were found to be very large and to trace the transport of water in the storms reflecting changes in basic structural features. Because the stable isotope ratios of rains from tropical cyclones are so low flooding associated with land falling tropical cyclones introduces a negative isotopic spike into the coastal surface waters. In addition the stable isotope ratios of water vapor in the vicinity of tropical cyclones is anomalously low. This suggests that carbonate shelled organisms such as ostracoda living in coastal waters have the potential to record the isotopic spike and thereby provide a long term record of tropical storm activity in sediment cores containing fossil shells. Likewise, tree rings in coastal environments offer a similar potential. We have analyzed the oxygen isotopic composition of ostrcoda shells formed in the floodwaters of Tropical Storm Allison (2001) and discovered the negative isotopic 1 16 spike. Because we had learned that storm activity has a major impact on the stable isotope ratios of water vapor in the tropics and sub-tropics we decided to analyze the isotopic compositions of water vapor in different locations in the tropics. We did this in Puerto Escondido, Mexico in July 1998, near Kwajalein Island in the Pacific in 1999 as part of a TRMM summer field program and in 2001 in Key West, Florida as part of the CAMEX 4 summer field program. Our isotopic studies along with our earlier tropical cyclone studies showed that the low isotopic ratios in water vapor induced by exposure to rains the storms persisted for 48 hours often far away from the original storm site. We also noted that positive isotopic spikes were introduced into atmospheric water vapor if winds were high and extensive sea spray was present. These findings have a significant impact on the interpretation of the stable isotope studies of tropical ice cores found in the high mountain regions of the tropics. The assumption made in interpreting the ice core record is that the source water vapor evaporated from the sea surface is in near isotopic equilibrium with the seawater and undergoes a decrease during its transport that reflects the change in temperature from the sea surface to the site of the ice core. Because an additional isotopic depletion occurs at the sea surface source area that depends on the intensity, duration and size of the tropical rain system the isotopic variations found in the ice cores must take into account changes in past storm activity in the tropics. These systems must be an important source of water vapor to the ice cores because they charge the troposphere with water vapor to a far greater vertical height than evaporation in quiescent regions. Finally, an interest in increased heat transfer in thnterior of tropical cyclones resulting from greater amounts of sea spray is a topic of considerable interest to the research community. Increases in sea spray may be related to rapid changes in the intensity of hurricanes, a feature of hurricanes that currently is very poorly forecast. Project CBLAST of the Hurricane Research Division of NOAA is an active program that uses P3 research aircraft to evaluate this problem. An instrument has been designed and built at the University of Houston that will be placed on the P3 research aircraft during the 2004 hurricane season. It continuously measures the salt content of rain in hurricanes. Changes in the salt content of the rains should reflect the abundance of sea spray at the sea surface. In this way maps of sea spray intensity in hurricanes may be forthcoming. This should help computer modelers who simulate hurricanes to better understand the potential of changes in sea spray to change the intensity of hurricanes. The cost of designing, building and installing this instrument was borne largely by funding from this NASA grant. A list of presentations at national meetings and publications that were as the result of funding from this NASA grant are found in the report.

Lawrence, James R.↗