Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “power control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

An Investigation of Heuristic Control Strategies for Multi-Electrolyzer Wind-Hydrogen Systems Considering Degradation

With the growing demand for renewable-energy-powered hydrogen generation and the corresponding increase in plant capacity, individually controlling many electrolyzer stacks will be critical for increasing the plant's lifetime and efficiency. This paper introduces a rule-based controller framework targeting electrolyzer degradation to explore the opportunity space in multi-stack hydrogen plant control. A novel control-oriented degradation model is also presented in this work, which quantifies the impact of steady power input, fluctuating power input, and the number of startup/shutdown cycles on electrolyzer degradation. Using a wind power input signal, 13 controller configurations are tested on 5 MW hydrogen plants consisting of 2, 5, 10, and 25 stacks. These configurations are evaluated on their capability to mitigate electrolyzer degradation and efficiently produce hydrogen from the time-varying input power. The results show that multi-stack control for degradation can extend the plant's lifetime by more than a factor of 3 with minimal impact on instantaneous hydrogen production.

control↗

Power Grid Simulation Testbed for Transactive Energy Management Systems

To effectively engage demand-side and distributed energy resources (DERs) for dynamically maintaining the electric power balance, the challenges of controlling and coordinating building equipment and DERs on a large scale must be overcome. Although several control techniques have been proposed in the literature, a significant obstacle to applying these techniques in practice is having access to an effective testing platform. Performing tests at scale using real equipment is impractical, so simulation offers the only viable route to developmental testing at scales of practical interest. Existing power-grid testbeds are unable to model individual residential end-use devices for developing detailed control formulations for responsive loads and DERs. Furthermore, they cannot simulate the control and communications at subminute timescales. To address these issues, this paper presents a novel power-grid simulation testbed for transactive energy management systems. Detailed models of primary home appliances (e.g., heating and cooling systems, water heaters, photovoltaic panels, energy storage systems) are provided to simulate realistic load behaviors in response to environmental parameters and control commands. The proposed testbed incorporates software as it will be deployed, and enables deployable software to interact with various building equipment models for end-to-end performance evaluation at scale.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Assessing DER Network Cybersecurity Defences in a Power-Communication Co-Simulation Environment

Increasing penetrations of interoperable distributed energy resources (DER) in the electric power system are expanding the power system attack surface. Maloperation or malicious control of DER equipment can now cause substantial disturbances to grid operations. Fortunately, many options exist to defend and limit adversary impact on these newly-created DER communication networks, which typically traverse the public internet. However, implementing these security features will increase communication latency, thereby adversely impacting real-time DER grid support service effectiveness. In this work, a collection of software tools called SCEPTRE were used to create a co-simulation environment where SunSpec-compliant PV inverters were deployed as virtual machines and interconnected to simulated communication network equipment. Network segmentation, encryption, and moving target defence security features were deployed on the control network to evaluate their influence on cybersecurity metrics and power system performance. The results indicated that adding these security features did not impact DER-based grid control systems but improved the cybersecurity posture of the network when implemented appropriately.

97 MATHEMATICS AND COMPUTING↗

Uncertainty Quantification and Sensitivity Analysis of Non-Nuclear Advanced Controls Testbed Reactor Mockup

The research presented in this report describes our progress in applying stochastic methods and uncertainty quantification, parametric study, and variance-based sensitivity analysis (also known as Sobol sensitivity analysis) to a full-core model of a nuclear thermal propulsion (NTP) system simulated with Griffin, with the goal of developing a reduced order (surrogate) model which can be rapidly sampled while perturbing multiple input parameters. In this NTP system, reactivity and power feedback affect the rotation of control drums, which are controlled by a hybrid proportional, integral and derivative (PID) controller, actuated by the power demand and reactivity feedback from the numerical model. This model uses reactor kinetic feedback (mean generation time and $\beta$ from a transient Griffin simulation executed with the improved quasi-static method to provide the kinetic parameters) as inputs to functions which control the CD rotation angle. Using a number of stochastic method approaches, we developed a dual purpose training-surrogate model of the NTP system using polynomial regression. The trained model can be rapidly sampled while simultaneously perturbing various input parameters of the model, such as coefficients on the PID control, or temperature (directly affect the neutron cross section). The surrogate model delivers accurate results orders-of-magnitude faster (minutes, not days) than the base model. Once the base model has been trained, distributions of the uncertain parameters can be changed at will to investigate the effects of perturbing multiple inputs and their effect on the output. For example, coefficients used in the PID control system may vary due to some physical interference, or there may be uncertainty in the temperature of the neutron cross sections in various regions of the reactor. A distribution can be placed on these parameters and operational boundaries can be determined. The goal of this work is to support development of an advanced control system to operate CDs in a functioning NTP system.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Hierarchical Control of Utility-Scale Solar PV Plants for Mitigation of Generation Variability and Ancillary Service Provision

This paper presents a hierarchical control system to mitigate the variability of solar photovoltaic (PV) power plant and provide ancillary services to the electric grid without the need for additional non-solar resources. With coordinated management of each inverter in the system, the control system commands the power plant to proactively curtail a small fraction of its instantaneous maximum power potential, which gives the plant enough headroom to ramp up production from the overall power plant, for a service such as regulation reserve. This control system is practical for continuously changing cloud cover conditions in partially cloudy days. A case study from a site in Hawaii with one-second resolution solar irradiance data is used to verify the efficacy of the proposed control system. The proposed control algorithm is subsequently compared with the alternative control technology from the literature, the grouping control algorithm; the results show that the proposed hierarchical control system is over 10 times more effective in reducing generator mileage to support power fluctuations from solar PV power plants.

14 SOLAR ENERGY↗

Statistical Multiobjective Optimization of Thiospinel CoNi 2 S 4 Nanocrystal Synthesis via Design of Experiments

Thiospinels, such as CoNi 2 S 4 , are showing promise for numerous applications, including as catalysts for the hydrogen evolution reaction, hydrodesulfurization, and oxygen evolution and reduction reactions; however, CoNi 2 S 4 has not been synthesized as small, colloidal nanocrystals with high surface-area-to-volume ratios. Traditional optimization methods to control nanocrystal attributes such as size typically rely upon one variable at a time (OVAT) methods that are not only time and labor intensive but also lack the ability to identify higher-order interactions between experimental variables that affect target outcomes. Herein, we demonstrate that a statistical design of experiments (DoE) approach can optimize the synthesis of CoNi 2 S 4 nanocrystals, allowing for control over the responses of nanocrystal size, size distribution, and isolated yield. After implementing a 2 5–2 fractional factorial design, the statistical screening of five different experimental variables identified temperature, Co:Ni precursor ratio, Co:thiol ratio, and their higher-order interactions as the most critical factors in influencing the aforementioned responses. Second-order design with a Doehlert matrix yielded polynomial functions used to predict the reaction parameters needed to individually optimize all three responses. A multiobjective optimization, allowing for the simultaneous optimization of size, size distribution, and isolated yield, predicted the synthetic conditions needed to achieve a minimum nanocrystal size of 6.1 nm, a minimum polydispersity (σ/$\bar{d}$) of 10%, and a maximum isolated yield of 99%, with a desirability of 96%. The resulting model was experimentally verified by performing reactions under the specified conditions. Furthermore, our work illustrates the advantage of multivariate experimental design as a powerful tool for accelerating control and optimization in nanocrystal syntheses.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Reinforcement Learning‐Based Adaptation of Grid Following Inverter's Internal Controller to Networked Microgrids' Strengths

The varying topological configurations, generator commitments and dispatches, and dynamic load demand lead to changing system's strengths during the operations of networked microgrids. When the system's strengths significantly change, the fixed control gains at large devices may result in unsatisfactory system performance; this necessitates the tuning of the control gains at large devices to adapt to the changing system's strengths. In this paper, observer-based reinforcement learning (RL) is utilised to automatically tune the proportional-integral (PI) gains of phase lock loop (PLL) controller of grid-following (GFL) inverters to adapt to the changing strengths of microgrids and networked microgrids. The RL agent in this framework augments an observer predicting system's strengths, from which the RL control policy will adjust accordingly to tune the PLL controller's gains towards the system's strengths. Also, to enhance the control performance, the recently introduced Barrier function-based RL framework is leveraged for the design of reward function to prevent the high frequency nadir. An operational 26 kV electric distribution system, which is modelled as networked microgrids, is used to illustrate the need and effectiveness of the proposed RL-tuned control.

frequency response↗

Numerical Modelling of a Two-Body Point Absorber Featuring Variable Geometry

This work presents a novel wave energy converter (WEC) device concept that incorporates variable geometry modules into a two-body point absorber type WEC. The variable geometry modules consist of air inflatable bags in the surface float and a water inflatable ring in the reaction body. The variable geometry floats are able to provide greater control over the device hydrodynamics; they can be inflated or deflated to emphasize either power absorption or load shedding. The device geometry is controlled in a quasi-static fashion, while the power take-off (PTO) unit is controlled on a wave-to-wave timescale. The surface float is tethered directly to the submerged reaction body through PTO tether lines. A linear time-domain analysis, conducted using open-source Wave Energy Converter (WEC-Sim) software, was used to estimate the absorbed power of the WEC in sea states defined by the Wave Energy Prize. WEC power performance was weighted against the expected capital cost of building the load bearing structure of the device, providing an estimated ACE value. The inclusion of the variable geometry modules was shown to be effective in altering the device geometry to improve power capture with a near proportional increase in expected costs, providing a nearly constant power-to-cost ratio.

cost of energy↗

AI & Physics-Based Bad Command/Data Detection in Large Power Electronics Systems: Multi-Port Autonomous Reconfigurable Solar Power Plant (MARS)

Detection of bad data from measurement sensors and bad commands from control centers need to be carried out to avoid instabilities within large power electronics systems. Towards the same, in this paper, model and data driven methods are proposed to identify anomalies in measured data and commands received by large power electronics systems. The large power electronics system considered in this paper is a multi-port autonomous reconfigurable solar power plant (MARS), which consists of photovoltaic (PV) and energy storage systems (ESSs) that connect to high-voltage direct current (HVdc) system and transmission ac power grid. The proposed algorithms in the MARS power plant to detect bad data from measurements and bad commands from control centers are evaluated in simulations and hardware-in-the-loop (HIL) tests. Furthermore, it has been observed that the proposed algorithms are able to detect bad measurements and commands in all the use cases evaluated.

14 SOLAR ENERGY↗

Implementing Inertial Control for PMSG-WTG in Region 2 Using Virtual Synchronous Generator with Multiple Virtual Rotating Masses

With the increasing integration of renewable energy, the problems associated with a deteriorating grid frequency profile and potential power system instability have become more significant. In this paper, the inertial control algorithm using a virtual synchronous generator (VSG) is implemented on a Type 4 permanent magnet synchronous generator (PMSG) wind turbine generator (WTG). The overall nonlinear dynamic model and its small-signal linearization of the PMSG-WTG using a VSG is established and comprehensively analyzed. Inevitably, the direct application of the VSG introduces a large inertia, which causes conflict between the fast variance of available wind power and inverter control with slow dynamics, particularly in Region 2 of the wind turbine. Aiming to address such issues, a VSG with multiple virtual rotating masses is proposed to improve the active power tracking performance as well as to boost the inertial control of a VSG. The inertial responses are verified in a modified 10-MVA IEEE 14-bus microgrid system. The assessment of the simulation results demonstrates the applicability of the VSG on renewable energy generation units.

17 WIND ENERGY↗

Smart Outlets: Wireless Meter and Control Systems for Plug and Process Loads

Smart outlets control the flow of power to devices plugged into them and measure their energy use. The energy use data can be accessed via an online dashboard or smartphone application, allowing the user to turn power to plug-in devices on or off based on a schedule established in the dashboard or application. This four-page resource is a fact sheet meant to educate commercial building owners on smart outlets: what they are, why we use them, and how to use them in a way that will achieve energy savings while maintaining occupant comfort. The resource also describe how to procure a smart outlet system and how to fully capture their benefits over time. This resource was developed to support the Better Buildings Alliance Plug and Process Loads Technology Research Team.

30 DIRECT ENERGY CONVERSION↗

A New Offering for the Seaman Status Labyrinth - Seaman Status for Nuclear Reactor Operators on Floating Nuclear Power Plants

Floating nuclear power plants present a unique operating environment for land-based nuclear reactor operators. Traditionally located in the control room of a nuclear power plant on land, development of floating nuclear power plants exposes the traditional land-based employees to the marine environment. With the extension of nuclear power generation facilities into the maritime domain, do nuclear reactor operators working on a floating nuclear power plant qualify as seaman under maritime law? Applying existing maritime law, the answer is no, a nuclear reactor operator who operates the nuclear reactor on a floating nuclear power plant does not qualify as a seaman because their work is not in support of the mission of the vessel and the reactor is not connected to a vessel because a floating nuclear power plant is not a vessel. Applying the analysis developed by the Supreme Court in Chandris v. Latsis and the recent Sanchez v. Smart Fabricators of Texas, L.L.C. en banc decision by the Fifth Circuit, a nuclear reactor operator on a floating nuclear power plant does not qualify for seaman status under the Jones Act because their function supports the operation of the reactor and the structure on which the reactor resides does not meet the reasonable person standard established in Lozman v. City of Riviera Beach. Further, existing case law highlights that rendering a structure practically impossible to move eliminates the structure from consideration as a vessel. Because a floating nuclear power plant may be anchored at a seaport or anchored offshore but connected via transmission cables and protected by physical protection barriers, a floating nuclear power plant, with no current means of propulsion is rendered a power plant on water, which is its true function. Recognizing that technological change may alter the conclusion presented in this Article, current designs and structures that exist illustrate the intersection between nuclear and maritime law and the ever-evolving concepts that underpin seamen status in maritime law.

Fialkoff, Marc↗

Virtual Synchronous Generator Control of Multi-port Autonomous Reconfigurable Solar Plants (MARS)

Multi-port autonomous reconfigurable solar power plant (MARS) is an integrated concept for integration of solar photovoltaic (PV) and energy storage systems (ESS) to transmission alternating current (ac) grid and high-voltage direct current (HVdc) links. The integrated development incorporates advanced control methods to provide enhanced grid ancillary services such as fast frequency responses and dynamic voltage support. In this paper, the virtual synchronous generator (VSG) control algorithm of MARS is discussed. The proposed VSG-based control enables enhanced synthetic inertial response and flexible frequency response characteristics of hybrid PV and ESS power plants in accordance with grid ancillary service requirements. Multi-port power electronics interface allows controlled emergency power support from MARS to local transmission ac grid and remote grid through the HVdc link. The performance of VSG control is validated using a reduced-order model of MARS in Simulink. Methods for estimating grid ancillary service capabilities of MARS are also discussed.

Pan, Jiuping↗

Parameter-Varying Hydrodynamic Model of a Single Vane in a Variable-Geometry Oscillating Surge Wave Energy Converter: Preprint

This paper presents a study on the time-varying hydrodynamic modeling of an individual flap of a variable geometry oscillating surge wave energy converter (VGOSWEC). The WEC design incorporates controlled surfaces that can modify their orientation relative to the wave motion, reducing hydrodynamic pressure and related loads. This research focuses on characterizing the behavior of the oscillating WEC using a simplified model and three methods for achieving a continuous time-variant model: discrete hydrodynamic parameters, interpolation of hydrodynamic parameters, and a fitting function. The results of this study contribute to the understanding of time-varying hydrodynamic effects in variable geometry oscillating WECs. The findings provide insights into the potential for reducing structural loads and improving the overall performance of such devices. Further research and development in this area could lead to advancements in WEC technologies, enabling their integration into the competitive energy market.

HYDRO ENERGY,TIDAL AND WAVE POWER↗

Draft Methodology for Cybersecurity Analysis for Adoption of Wireless Technology in Nuclear Power Plants

The report is delivered as DOE-NE Cybersecurity Program Milestone M2CT-22IN1104014-Industry cybersecurity guidance adoption status. The milestone is specifically to document the process and the status of the efforts towards developing guidance in support of industry’s adoption of wireless communication technologies. To transform the operation of nuclear power plants, including domestic light-water reactors, advanced reactors, microreactors, and fission battery, for grid and non-grid applications, secure and resilient wireless capabilities are required. In addition, to realize new operational concepts such as autonomous operation and remote monitoring, advanced sensor, and instrumentation, wireless technology is essential. However, industry implementation is low, and there is no technical basis for how to understand and address potential risks for wireless communications for critical plant functions. A methodology with a technical basis for implementing secure wireless communication is crucial. This wireless adoption methodology is intended to assist a licensee in identifying an appropriate technological approach for securing wireless communications in nuclear power plant. However, this methodology does not provide guidance for addressing wireless design criteria or for addressing all the cybersecurity commitments in licensees’ cybersecurity plans (CSPs) including addressing security impact analysis that a licensee must perform before an update to a Critical Digital Asset (CDA). This methodology guides a licensee through a process of evaluating a proposed wireless implementation and drafting a plant change notification for an example use case. The example is a generic/nonproprietary version of the first test case of the methodology, which, if successfully implemented, is part of the consideration for protecting other functions’ use of wireless in a cybersecure manner.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Safety Assurance of Software and Machine Learning Development for Nuclear Instrumentation and Controls

Digital instrumentation and control (DI&C) systems monitor and control parameters in nuclear power plants. Ensuring their safety is a critical part of ensuring overall plant safety. Nuclear power plant licensing generates thousands of safety documents that could be organized more effectively using a safety assurance case (SAC). We conducted a literature survey of SACs and created a SAC framework for DI&C software using Goal Structuring Notation (GSN). This framework focuses on four software development processes: management & assurance, pre-developed software (PDS) qualification, the Software Development Life Cycle (SDLC), and the Machine Learning Development Life Cycle (MLDLC). We organized our framework using a novel level structure that can be applied to other SACs to improve their clarity. Finally, we demonstrate how our framework can be incorporated as part of a SAC for a larger reactor system.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Microreactor Automated Control System - Digital Twin Models and Advanced Control Systems Updates

Automation of control systems is expected to be important in the economic and safe operation of microreactors. Therefore, there is a need to develop and demonstrate automated control for microreactors, along with the development of testbeds for this purpose. This report provides updates on the status of a nonnuclear microreactor automated control system (MACS)—a real-time, hardware-in-the-loop testbed for non-nuclear testing of microreactor control system automation. A real-time hardware-in-the-loop testbed incorporates the realistic dynamics of physical systems into control system development and testing. The collaborative effort between Oak Ridge National Laboratory (ORNL) and Idaho National Laboratory (INL) resulted in the development of a prototypic microreactor plant-level digital twin that includes the reactor and a balance of plant system. Advanced control strategies were incorporated to demonstrate testing of control automation solutions. The gRPC communication protocol, which was implemented in the hardware-in-the-loop testbed by INL, was coupled to a digital twin model developed using the TRANsient Simulation Framework of Reconfigurable Models (TRANSFORM) library in Modelica. This digital twin simulation was tested with the ViBRANT hardware for realistic feedback and visual representation of control action in real time. A modular Python client structure was developed to manage functional mock-up unit-based simulation and real-time gRPC communication. Hardware-in-the-loop testing indicated that the modeled reactor—a natural-convection, molten-salt coolant loop configuration—responds well to control of drum positioning for modulation of reactor core power, as well as system-level control and downstream demand changes. Ongoing research is focused on integrating additional control algorithms that utilize data from newly included sensors within the MACS hardware testbed, as well as demonstrating and assessing the performance of the different automated control algorithms on multiple additional operational scenarios.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗