Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “optical instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

SIM spectral characteristics and accuracy analysis

The Space Interferometry Mission (SIM) will perform global astrometry (full sky), local wide-angle (15 degree) and narrow-angle (1 degree) observations to search extra-solar planets, and can calibrate stellar and galactic evolution theories. The astrometric accuracy of the SIM mission depends on spectral characteristics of the optics, detectors and targets. This paper will discuss the photometric throughput of the SIM instrument, and analyze effects of wavefront errors, optical mismatches and control biases as a function of wavelength. The color dependence models of the instrument optics including mirrors, lenses, field-stop and beam-splitter are presented. The performances of different detectors with a variety of coatings are compared. A model of the SIM fringe spectrometer is created. For early and late types of stars, brightness dependency errors are analyzed for different combinations of optics and detectors. Visibility loss due to imperfect optics is investigated in detail. Based on the models of instrument and estimated visibilities, the astrometric accuracies for various kinds of stars are evaluated. It is important to emphasize that not only light sources, mirrors, lenses, field stop and detectors are all wavelength dependent, but also fringe visibility loss, wavefront error, optics control error, etc. are all a function of wavelengths. For the first time the estimate of SIM performance is based on spectral analysis of all factors above, rather than monochromatic approximations of detected fringes, or simply adopted constants. This paper summarizes the astrometric accuracies for a wide range of stars and various combinations of optical design and detector configurations. It has been verified that SIM has astrometric accuracy of about 4 μas for targets with different spectra.

Shao, Michael↗

Passive IFF: Autonomous Nonintrusive Rapid Identification of Friendly Assets

A proposed optoelectronic instrument would identify targets rapidly, without need to radiate an interrogating signal, apply identifying marks to the targets, or equip the targets with transponders. The instrument was conceived as an identification, friend or foe (IFF) system in a battlefield setting, where it would be part of a targeting system for weapons, by providing rapid identification for aimed weapons to help in deciding whether and when to trigger them. The instrument could also be adapted to law-enforcement and industrial applications in which it is necessary to rapidly identify objects in view. The instrument would comprise mainly an optical correlator and a neural processor (see figure). The inherent parallel-processing speed and capability of the optical correlator would be exploited to obtain rapid identification of a set of probable targets within a scene of interest and to define regions within the scene for the neural processor to analyze. The neural processor would then concentrate on each region selected by the optical correlator in an effort to identify the target. Depending on whether or not a target was recognized by comparison of its image data with data in an internal database on which the neural processor was trained, the processor would generate an identifying signal (typically, friend or foe ). The time taken for this identification process would be less than the time needed by a human or robotic gunner to acquire a view of, and aim at, a target. An optical correlator that has been under development for several years and that has been demonstrated to be capable of tracking a cruise missile might be considered a prototype of the optical correlator in the proposed IFF instrument. This optical correlator features a 512-by-512-pixel input image frame and operates at an input frame rate of 60 Hz. It includes a spatial light modulator (SLM) for video-to-optical image conversion, a pair of precise lenses to effect Fourier transforms, a filter SLM for digital-to-optical correlation-filter data conversion, and a charge-coupled device (CCD) for detection of correlation peaks. In operation, the input scene grabbed by a video sensor is streamed into the input SLM. Precomputed correlation-filter data files representative of known targets are then downloaded and sequenced into the filter SLM at a rate of 1,000 Hz. When there occurs a match between the input target data and one of the known-target data files, the CCD detects a correlation peak at the location of the target. Distortion- invariant correlation filters from a bank of such filters are then sequenced through the optical correlator for each input frame. The net result is the rapid preliminary recognition of one or a few targets.

Moynihan, Philip↗

Externally-Modulated Electro-Optically Coupled Detector Architecture for Nuclear Physics Instrumentation

A new laser-based externally-modulated electro-optically coupled detector (EOCD) architecture is being developed to enable high-density readout for radiation detectors with accurate analog radiation pulse shape and timing preservation. Unlike digital conversion before electro-optical modulation, the EOCD implements complete analog optical signal modulation and multiplexing in its detector front-end. The result is a compact, high performance detector readout that can be both radiation tolerant and immune to magnetic fields. In this work, the feasibility of EOCD was explored by constructing a two-wavelength laser-based externally-modulated EOCD, and testing analog pulse shape preservation and wavelength-division multiplexing (WDM) crosstalk. Comparisons were first made between the corresponding initial pulses and the electro-optically coupled analog pulses. This confirmed an excellent analog pulse preservation over $ sim {hbox {29}}% $ of the modulator’s switching voltage range. Optical spectrum analysis revealed less than $-{hbox {14}}~hbox{dB}$ crosstalk with 1.2 nm WDM wavelength bandgap, and provided insight on experimental conditions that could lead to increased inter-wavelength crosstalk. Further discussions and previous research on the radiation tolerance and magnetic field immunity of the candidate materials were also given, and quantitative device testing is proposed in the future.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of an optical fiber cable link for lightning instrumentation

A lightning instrumentation system was designed to record current magnitudes of lightning strikes that hit a launch pad service structure at NASA's Kennedy Space Center. The instrumentation system consists of a lightning ground rod with a current sensor coil, an optical transmitter, an optical fiber cable link, a detector receiver, and a recording system. The transmitter is a wideband pulse transformer driving an IR LED emitter. The transmitter operates linearly as a transducer. A low loss fiber bundle provides isolation of the recorder system from the electromagnetic field of the lightning strike. The output of an optical detector receiver module is sampled and recorded in digital format. The significant factors considered in the design were dynamic range, linearity, mechanical configuration, electromagnetic isolation, and temperature compensation.

Grove, C. H.↗

Self-Raman Nd:YVO4 Laser and Electro-Optic Technology for Space-Based Sodium Lidar Instrument

We are developing a laser and electro-optic technology to remotely measure Sodium (Na) by adapting existing lidar technology with space flight heritage. The developed instrumentation will serve as the core for the planning of an Heliophysics mission targeted to study the composition and dynamics of Earth's mesosphere based on a spaceborne lidar that will measure the mesospheric Na layer. We present performance results from our diode-pumped tunable Q-switched self-Raman c-cut Nd:YVO4 laser with intra-cavity frequency doubling that produces multi-watt 589 nm wavelength output. The c-cut Nd:YVO4 laser has a fundamental wavelength that is tunable from 1063-1067 nanometers. A CW (Continuous Wave) External Cavity diode laser is used as a injection seeder to provide single-frequency grating tunable output around 1066 nanometers. The injection-seeded self-Raman shifted Nd:VO4 laser is tuned across the sodium vapor D2 line at 589 nanometers. We will review technologies that provide strong leverage for the sodium lidar laser system with strong heritage from the Ice Cloud and Land Elevation Satellite-2 (ICESat-2) Advanced Topographic Laser Altimeter System (ATLAS). These include a space-qualified frequency-doubled 9 watts-at-532-nanometer wavelength Nd:YVO4 laser, a tandem interference filter temperature-stabilized fused-silica-etalon receiver and high-bandwidth photon-counting detectors.

Krainak, Michael A.↗

Self-Raman Nd:YVO4 Laser and Electro-Optic Technology for Space-Based Sodium Lidar Instrument

We are developing a laser and electro-optic technology to remotely measure Sodium (Na) by adapting existing lidar technology with space flight heritage. The developed instrumentation will serve as the core for the planning of an Heliophysics mission targeted to study the composition and dynamics of Earth's mesosphere based on a spaceborne lidar that will measure the mesospheric Na layer. We present performance results from our diode-pumped tunable Q-switched self-Raman c-cut Nd:YVO4 laser with intra-cavity frequency doubling that produces multi-watt 589 nm wavelength output. The c-cut Nd:YVO4 laser has a fundamental wavelength that is tunable from 1063-1067 nanometers. A CW (Continuous Wave) External Cavity diode laser is used as a injection seeder to provide single-frequency grating tunable output around 1066 nanometers. The injection-seeded self-Raman shifted Nd:VO4 laser is tuned across the sodium vapor D2 line at 589 nanometers. We will review technologies that provide strong leverage for the sodium lidar laser system with strong heritage from the Ice Cloud and Land Elevation Satellite-2 (ICESat-2) Advanced Topographic Laser Altimeter System (ATLAS). These include a space-qualified frequency-doubled 9 watts-at-532-nanometer wavelength Nd:YVO4 laser, a tandem interference filter temperature-stabilized fused-silica-etalon receiver and high-bandwidth photon-counting detectors.

Krainak, Michael A.↗

The Optical Corrector for the Dark Energy Spectroscopic Instrument

The Dark Energy Spectroscopic Instrument (DESI) is currently measuring the spectra of 40 million galaxies and quasars, the largest such survey ever made to probe the nature of cosmological dark energy. The 4 m Mayall telescope at Kitt Peak National Observatory has been adapted for DESI, including the construction of a 3$_{.}^{°}$2 diameter prime focus corrector that focuses astronomical light onto a 0.8 m diameter focal surface with excellent image quality over the DESI bandpass of 360–980 nm. The wide-field corrector includes six lenses, as large as 1.1 m in diameter and as heavy as 237 kilograms, including two counterrotating wedged lenses that correct for atmospheric dispersion over zenith angles from 0° to 60°. The lenses, cells, and barrel assembly all meet precise alignment tolerances on the order of tens of microns. The barrel alignment is maintained throughout a range of observing angles and temperature excursions in the Mayall dome by use of a hexapod, which is itself supported by a new cage, ring, and truss structure. In this paper we describe the design, fabrication, and performance of the new corrector and associated structure, focusing on how they meet DESI requirements. In particular, we describe the prescription and specifications of the lenses, design choices and error budgeting of the barrel assembly, stray light mitigations, and integration and test at the Mayall telescope. We conclude with some validation highlights that demonstrate the successful corrector on-sky performance, and we list some lessons learned during the multiyear fabrication phase.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Towards an Optimal Estimation Retrieval of Cirrus Cloud Optical and Microphysical Properties Using Hyperspectral Shortwave Instruments and A Fast Radiative Transfer Algorithm

Cirrus cloud retrieval products (here, cloud optical depth, effective particle size, and cloud top height) are important inputs into numerical weather and climate models. Uncertainties in such retrieval products, as a matter of course, propagate downstream, impacting model calculations. Improvements in high-quality global cirrus cloud optical and microphysical data products from satellite observations are needed to understand and reduce retrieval uncertainties. Hyperspectral shortwave instruments produce high-resolution and information-dense spectra, thus offering the opportunity to reduce uncertainties in retrieval products. We are in the process of developing a retrieval that uses the very fast Principal Component Radiative Transfer Model in the solar spectral region (PCRTM-Solar) in the forward model calculations. This retrieval will use measured reflectances from the NASA Earth Surface Mineral Dust Source Investigation (EMIT) and the forthcoming Climate Absolute Radiance and Refractivity Observatory Pathfinder (CLARREO-Pathfinder) instruments. In this manuscript we present progress towards a reference retrieval employing a widely used, verified, accurate, yet computationally slower radiative transfer modeling technique. The reference retrieval, while too slow for using the complete hyperspectral measurement, will allow us to study the behavior of retrieval products and help us verify results from our in-development fast retrieval. Both retrievals will use the optimal estimation retrieval framework. In this manuscript we present results from an uncertainty analysis considering three uncertainty sources for a cirrus cloud retrieval in the form of error covariance matrices: reflectance uncertainty due to water vapor, the reflectance uncertainty due to ice crystal scattering assumptions, and the instrument measurement uncertainty. Results show that the uncertainty due to habit selection is the largest, while that due to water vapor is at most 0.6% relative to channel reflectance. As a first step, the retrieval is being designed for single layer ice clouds over open ocean water.

Cirrus cloud↗

Mesospheric and lower thermospheric winds, temperatures densities, and volume emission rates

This memo has been written to report on the progress made under grant NAG1-1315 and to request a continuation of funding for this work. Our proposal involved a plan to utilize an existing ground-based chain of optical and radar facilities to assemble a comprehensive, long-term, multi-station base of upper-mesospheric and lower thermospheric measurements of neutral winds, temperatures, and volume emission rates that can be used to make comparisons with data from the HRDI and WINDII instruments that are flying aboard the UARS spacecraft. The ground-based, optical data were to be obtained on a routine basis from five geographically separated observatories at: Thule, Greenland; Sondrestrom, Greenland; Watson Lake, Yukon (replacing Calgary, Alberta); Ann Arbor, Michigan; and Maynooth, Eire. Several different optical instruments are present at these sites: the total array of instruments is comprised of five Fabry-Perot interferometers, two half meter Ebert-Fastie spectrometers, one all-sky CCD imager, and a near infra-red Michelson Fourier transform spectrometer. In addition to these optical instruments, data were to be obtained from the incoherent scatter radar at Sondrestrom, Greenland. These radar measurements are comprised of neutral winds, temperatures, and densities from altitudes between approximately 70 - 120 km. The optical measurements are obtained locally from specific altitudes depending on the emission line studied. For example, red line optical data come from about 220 km. In this report we summarize the progress made in obtaining these data and relate it to the specific tasks outlined in the original grant application. These tasks are discussed in the next section. Progress towards their completion is discussed in section three, while future plans and summary are described in section four.

Killeen, Timothy L.↗

Structural dynamic measurement practices for turbomachinery at the NASA Lewis Research Center

Methods developed for measuring blade and rotor-shaft system response include optical systems, transient instruments, and special digital data processing equipment. Optical methods offer some distinct benefits for blade vibration measurement. Transient and steady state measurements of the response of rotor-shaft systems strongly affect analytical methods development. Digital computing systems allow processing of large volumes of high speed data from rotating blade sets. Also, digital systems develop useful vibration response signatures from randomly excited systems. Research facilities include the spin rig facility and the transient rotor response lab.

Kiraly, L. J.↗

Remote detection of boundary-layer transition by an optical system

This instrument development program was funded because of the urgent need to measure boundary-layer transition in wind tunnels. In the course of this development program, a prototype was designed, built, and tested. Recent transonic experiments in the Boeing Model Transonic Wind Tunnel show that the interferometer results correlate very well with sublimating chemical tests.

Hall, Robert M.↗

Optical Micromachining

Under an SBIR (Small Business Innovative Research) with Marshall Space Flight Center, Potomac Photonics, Inc., constructed and demonstrated a unique tool that fills a need in the area of diffractive and refractive micro-optics. It is an integrated computer-aided design and computer-aided micro-machining workstation that will extend the benefits of diffractive and micro-optic technology to optical designers. Applications of diffractive optics include sensors and monitoring equipment, analytical instruments, and fiber optic distribution and communication. The company has been making diffractive elements with the system as a commercial service for the last year.

Source record↗

X-ray optics metrology limited by random noise, instrumental drifts, and systematic errors

Continuous, large-scale efforts to improve and develop third- and forth-generation synchrotron radiation light sources for unprecedented high-brightness, low emittance, and coherent x-ray beams demand diffracting and reflecting x-ray optics suitable for micro- and nano-focusing, brightness preservation, and super high resolution. One of the major impediments for development of x-ray optics with the required beamline performance comes from the inadequate present level of optical and at-wavelength metrology and insufficient integration of the metrology into the fabrication process and into beamlines. Based on our experience at the ALS Optical Metrology Laboratory, we review the experimental methods and techniques that allow us to mitigate significant optical metrology problems related to random, systematic, and drift errors with super-high-quality x-ray optics. Measurement errors below 0.2 mu rad have become routine. We present recent results from the ALS of temperature stabilized nano-focusing optics and dedicated at-wavelength metrology. The international effort to develop a next generation Optical Slope Measuring System (OSMS) to address these problems is also discussed. Finally, we analyze the remaining obstacles to further improvement of beamline x-ray optics and dedicated metrology, and highlight the ways we see to overcome the problems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimized Umkehr Profile Algorithm for Ozone Trend Analyses

The long-term record of Umkehr measurements from four NOAA Dobson spectrophotometers was reprocessed after updates to the instrument calibration procedures. In addition, a new data quality-control tool was developed for the Dobson automation software (WinDobson). This paper presents a comparison of Dobson Umkehr ozone profiles from NOAA ozone network stations (Boulder, OHP, MLO, Lauder) against several satellite records, including Aura Microwave Limb Sounder (MLS; ver. 4.2), and combined SBUV and OMPS records (NASA AGG and NOAA COH). A subset of satellite data is selected to match Dobson Umkehr observations at each station spatially (distance less than 200 km) and temporally (within 24 hours). Umkehr Averaging Kernels (AKs) are applied to vertically smooth all overpass satellite profiles prior to comparisons. The station Umkehr record consists of several instrumental records, which have different optical characterizations, and thus instrument-specific stray light contributes to the data processing errors and creates step changes in the record. This work evaluates the overall quality of Umkehr long-term measurements at NOAA ground-based stations and assesses the impact of the instrumental changes on the stability of the Umkehr ozone profile record. This paper describes a method designed to correct biases and discontinuities in the retrieved Umkehr profile that originate from the Dobson calibration process, repair, or optical realignment of the instrument. The M2GMI and GMI CTM ozone profile model output matched to station location and date of observation is used to evaluate instrumental step changes in the Umkehr record. Homogenization of the Umkehr record and discussion of the apparent stray light error in retrieved ozone profiles are the focus of this paper. Homogenization of ground-based records is of great importance for studies of long-term ozone trends and climate change.

Umkehr↗

bicep2/KECK ARRAY. IV. OPTICAL CHARACTERIZATION AND PERFORMANCE OF THE bicep2 AND KECK ARRAY EXPERIMENTS

bicep2 and the Keck Array are polarization-sensitive microwave telescopes that observe the cosmic microwave background (CMB) from the South Pole at degree angular scales in search of a signature of inflation imprinted as B-mode polarization in the CMB. bicep2 was deployed in late 2009, observed for three years until the end of 2012 at 150 GHz with 512 antenna-coupled transition edge sensor bolometers, and has reported a detection of B-mode polarization on degree angular scales. The Keck Array was first deployed in late 2010 and will observe through 2016 with five receivers at several frequencies (95, 150, and 220 GHz). bicep2 and the Keck Array share a common optical design and employ the field-proven bicep1 strategy of using small-aperture, cold, on-axis refractive optics, providing excellent control of systematics while maintaining a large field of view. This design allows for full characterization of far-field optical performance using microwave sources on the ground. Here we describe the optical design of both instruments and report a full characterization of the optical performance and beams of bicep2 and the Keck Array at 150 GHz.

79 ASTRONOMY AND ASTROPHYSICS↗

Optical Testing Using Portable Laser Coordinate Measuring Instruments

High precision, portable coordinate measuring instruments (CMI) such as laser radars (LR) and laser trackers (LT) have been used for optical system alignment and integration. The LRs ability to perform a non-contact scan of surfaces was previously utilized to characterize large spherical and aspheric mirrors. In this paper, we explore the use of a CMI as an accurate, fast, robust, and non-contact tool for prescription characterization of powered optical surfaces. Using Nikons MV-224350 LR and Leicas Absolute Tracker AT401402 instruments, proof of concept measurements were performed to characterize a variety of optical components by measuring the actual and apparent, or equivalently the direct and through (DT), coordinates of calibrated metrology targets. Custom macros in metrology software and other data reduction code were developed to compute surface-ray intercepts and surface slopes from the DT shots. The calculated data is fit to an aspheric surface formula to obtain the optimum prescription. The results were compared to the nominal parameters and were crosschecked using LR scans or other approaches. We discuss potential applications across the fields of optical component fabrication and system alignment and testing.

Khreishi, M.↗