Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “moderation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

Phenomenology of TMD parton distributions in Drell-Yan and 𝑍 0 boson production in a hadron structure oriented approach

We present a first practical implementation of a recently proposed hadron structure oriented (HSO) approach to transverse momentum dependent (TMD) phenomenology applied to Drell-Yan-like processes, including lepton pair production at moderate 𝑄 2 and 𝑍 0 boson production. We compare and contrast general features of our methodology with other common practices and emphasize aspects that we view as improvements. Separately, we discuss the importance of treatments that preserve various theoretical properties of the nonperturbative parts of TMD parametrizations for future applications that have the extraction of hadron structure as a primary goal. These include the HSO’s preservation of a basic TMD parton-model-like framework even while accounting for full TMD factorization and evolution, explicit preservation of the integral relationship between TMD and collinear parton density functions, and the ability to meaningfully compare different theoretical models of nonperturbative TMD parton distributions. In our examples, we show that there is significant sensitivity at moderate 𝑄 2 to both the form of the nonperturbative transverse momentum dependence and the parametrization of collinear parton densities. However, we also find that evolving to 𝑄 2 =𝑀$^2_𝑍$, without fitting, results in a satisfactory postdiction of existing data for 𝑍0 production, nearly independently of the modeling of nonperturbative transverse momentum behavior. We argue that this demonstrates that moderate 𝑄 measurements should be given greater weight than high 𝑄 measurements in extractions of nonperturbative transverse momentum dependence. We also obtain new extractions of the nonperturbative Collins-Soper kernel within the HSO approach. We discuss its features and compare with some earlier extractions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Nambu-Jona-Lasinio model description of weakly interacting Bose condensate and BEC-BCS crossover in dense QCD-like theories

QCD-like theories possess a positively definite fermion determinant at finite baryon chemical potential {mu}{sub B} and the lattice simulation can be successfully performed. While the chiral perturbation theories are sufficient to describe the Bose condensate at low density, to describe the crossover from Bose-Einstein condensation (BEC) to BCS superfluidity at moderate density we should use some fermionic effective model of QCD, such as the Nambu-Jona-Lasinio model. In this paper, using two-color two-flavor QCD as an example, we examine how the Nambu-Jona-Lasinio model describes the weakly interacting Bose condensate at low density and the BEC-BCS crossover at moderate density. Near the quantum phase transition point {mu}{sub B}=m{sub {pi}} (m{sub {pi}} is the mass of pion/diquark multiplet), the Ginzburg-Landau free energy at the mean-field level can be reduced to the Gross-Pitaevskii free energy describing a weakly repulsive Bose condensate with a diquark-diquark scattering length identical to that predicted by the chiral perturbation theories. The Goldstone mode recovers the Bogoliubov excitation in weakly interacting Bose condensates. The results of in-medium chiral and diquark condensates predicted by chiral perturbation theories are analytically recovered. The BEC-BCS crossover and meson Mott transition at moderate baryon chemical potential as well as the beyond-mean-field corrections are studied. Part of our results can also be applied to real QCD at finite baryon or isospin chemical potential.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

NDX: Neutron Dose Rate Meters with Extended Capabilities

Particle accelerators, irradiation facilities, and nuclear power plants would benefit from using neutron dose rate meters featuring improved energy response covering full range of expected neutron energies, improved dynamic range of measured dose rates while providing the real-time data, and improved ability to operate in harsh radiation environments including heavy photon backgrounds and pulsed beams. The novel design of the neutron moderator for the NDX dose rate meter implements a layer of a Beryllium-loaded medium Z material which, similar to the earlier known WENDI detectors, allows the device to detect higher energy neutron flux and convert it to dose. Using Beryllium helps to fill the known dip in the response functions around 5-50 MeV. Optimized design parameter set, obtained using FLUKA Monte Carlo simulations, features the NDX moderator made of polyethylene embedding a layer of BeCu alloy inside, with the dose rate response constant within ±10% in the neutron energy range from about 100 keV to 500 MeV, and ±25% essentially in the full energy range above thermal. A new sensor technique implemented in the NDX is based on using the Ionization Chamber (IC) filled with 3He gas to capture the moderated neutron fluence, and includes a symmetric IC filled with regular 4He to evaluate the contributions due to the non-neutron ionizing radiation. Advantages of the method include large accessible dynamic range, relative insensitivity of the IC probes to photon radiation fields, and the ability to subtract their contribution. Two prototype NDX detectors were built, calibrated, and operated in various conditions at the CEBAF 12 GeV electron accelerator at JLab. The first results showed reliable neutron dose rate measurements in the presence of overwhelming photon radiation fields, and at practical high dose rate levels of up to approximately 10 Sv/h. Detector design, operation, first results, and further development plans are presented.

Degtiarenko, Pavel V.↗

Microbial functional diversity covaries with permafrost thaw-induced environmental heterogeneity in tundra soil

Permafrost soil in high latitude tundra is one of the largest terrestrial carbon (C) stocks and is highly sensitive to climate warming. Understanding microbial responses to warming-induced environmental changes is critical to evaluating their influences on soil biogeochemical cycles. In this study, a functional gene array (i.e., geochip 4.2) was used to analyze the functional capacities of soil microbial communities collected from a naturally degrading permafrost region in Central Alaska. Varied thaw history was reported to be the main driver of soil and plant differences across a gradient of minimally, moderately, and extensively thawed sites. Compared with the minimally thawed site, the number of detected functional gene probes across the 15-65 cm depth profile at the moderately and extensively thawed sites decreased by 25% and 5%, while the community functional gene β-diversity increased by 34% and 45%, respectively, revealing decreased functional gene richness but increased community heterogeneity along the thaw progression. Particularly, the moderately thawed site contained microbial communities with the highest abundances of many genes involved in prokaryotic C degradation, ammonification, and nitrification processes, but lower abundances of fungal C decomposition and anaerobic-related genes. Significant correlations were observed between functional gene abundance and vascular plant primary productivity, suggesting that plant growth and species composition could be co-evolving traits together with microbial community composition. Finally, altogether, this study reveals the complex responses of microbial functional potentials to thaw-related soil and plant changes and provides information on potential microbially mediated biogeochemical cycles in tundra ecosystems.

59 BASIC BIOLOGICAL SCIENCES↗

Preliminary waste management plan of European spallation

The European Spallation Source (ESS) is the European common effort in designing and building a next generation large-scale user facility for studies of the structure and dynamics of materials. The proposed schematic layout of the ESS facility is based on a linear driver (linac) directing the proton beam (5 MW of 2.5 GeV) of 2.8 ms long pulses with a 20 Hz on a tungsten target where neutrons are produced via spallation reactions. Further the neutrons will be moderated to thermal and sub-thermal energies in a couple of moderators placed around the target. The moderators feed 22 beamlines guiding the neutrons to the scattering instruments, mainly for neutron scattering research, as has been previously mentioned. The objective of this work is to develop a waste management plan for ESS facility. In this respect two important aspects are analyzed. First the present status of the problem is outlined as follow. Estimate types and quantities of waste that the ESS project will generate at different stages: commission, operation, decommissioning were derived using: i) precise Monte Carlo calculations ii) scaling the activity from the operation experience of the existing spallation source installations for waste such it is difficult to predict level of activation or for components of the facility in stage of the preconceptual model. Associated waste treatment/conditioning options and final disposal route were further analyzed in order to define the waste type and packet descriptions in agreement with Swedish regulations and policy. It was found that the compilation of completely new waste type descriptions for qualification of the ESS waste for disposal will be necessary. Particular attention was devoted to 'problematic waste' as Beryllium reflector, C-14 from graphite used as core zone of the beam-dump and collimators or waste arising from the purification systems of both Helium and water cooling circuits. Management of waste on ESS site: collection/segregation systems, characterization system, storage options, is also described. In the second step, the acquired information is used for planning and implementing actions involving all participants (ESS, treatment facility operator, disposal operator, regulatory body and other authorized authorities). (authors)

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-272: Radiation Damage Comparison Between Intensity Modulated Radiotherapy and Field-In-Field Technique in Breast Cancer Treatments

Purpose: To compare normal tissue complications between IMRT and FIF treatment in breast cancer. Methods: 16 patients treated with IMRT plan and 20 patients treated with FIF plan were evaluated in this study. Both kinds of plans were generated using Eclipse treatment planning system by dosimetrist following clinical radiotherapy treatment guidelines. The plans were reviewed and approved by radiation oncologist. The average survival fraction (SF) for three different normal tissue cells of each concerned structure can be calculated from differential dose volume histogram (DVH) using linear quadratic model. The three types of normal tissues include radiosensitive, moderately radiosensitive and radio-resistant that represents 70%, 50% and 30% survival fractions, respectively, for a 2-Gy open field. Equivalent uniform doses (EUD) for corresponding normal tissues of each structure were calculated. Results: The EUDs of the lungs, heart, healthy breast and spinal cord with both IMRT and FIF treatments were calculated. Considering the average value of all IMRT plans, the lung of treated side absorbed 16.0% of dosage prescribed to the tumor if the radiosensitivity of the lung is similar to the radiosensitive cell line. For moderately radiosensitive and radio-resistant lung tissue, the average EUDs can be 18.9% and 22.4% of prescription. In contrast, patients treated with FIF plans were delivered 6.0%, 7.5% and 10.3% of prescribed dose for radiosensitive, moderately radiosensitive and radio-resistant lung tissue, respectively. Comparing heart EUDs between IMRT and FIF plans, average absorbed doses in IMRT treatment were 7.7%, 8.7% and 9.7% of prescription for three types of heart normal tissue cell lines while FIF treatments delivered only 1.3%, 1.5% and 1.6% of prescription dose. For the other organs, the results were similar. Conclusion: The results indicated that breast cancer treatment using IMRT technique had more normal tissue damage than FIF treatment. FIF demonstrated more effective normal tissue dose reduction in breast cancer treatment.

60 APPLIED LIFE SCIENCES↗

SU-E-J-86: Functional Conformal Planning for Stereotactic Body Radiation Therapy with CT-Pulmonary Ventilation Imaging

Purpose: To evaluate the functional planning using CT-pulmonary ventilation imaging for conformal SBRT. Methods: The CT-pulmonary ventilation image was generated using the Jacobian metric in the in-house program with the NiftyReg software package. Using the ventilation image, the normal lung was split into three lung regions for functionality (high, moderate and low). The anatomical plan (AP) and functional plan (FP) were made for ten lung SBRT patients. For the AP, the beam angles were optimized with the dose-volume constraints for the normal lung sparing and the PTV coverage. For the FP, the gantry angles were also optimized with the additional constraint for high functional lung. The MLC aperture shapes were adjusted to the PTV with the additional 5 mm margin. The dosimetric parameters for PTV, the functional volumes, spinal cord and so on were compared in both plans. Results: Compared to the AP, the FP showed better dose sparing for high- and moderate-functional lungs with similar PTV coverage while not taking care of the low functional lung (High:−12.9±9.26% Moderate: −2.0±7.09%, Low: +4.1±12.2%). For the other normal organs, the FP and AP showed similar dose sparing in the eight patients. However, the FP showed that the maximum doses for spinal cord were increased with the significant increment of 16.4Gy and 21.0Gy in other two patients, respectively. Because the beam direction optimizer chose the unexpected directions passing through the spinal cord. Conclusion: Even the functional conformal SBRT can selectively reduce high- and moderatefunctional lung while keeping the PTV coverage. However, it would be careful that the optimizer would choose unexpected beam angles and the dose sparing for the other normal organs can be worse. Therefore, the planner needs to control the dose-volume constraints and also limit the beam angles in order to achieve the expected dose sparing and coverage.

60 APPLIED LIFE SCIENCES↗

WE-EF-207-05: Monte Carlo Dosimetry for a Dedicated Cone-Beam CT Head Scanner

Purpose: Cone-Beam CT (CBCT) is an attractive platform for point-of-care imaging of traumatic brain injury and intracranial hemorrhage. This work implements and evaluates a fast Monte-Carlo (MC) dose estimation engine for development of a dedicated head CBCT scanner, optimization of acquisition protocols, geometry, bowtie filter designs, and patient-specific dosimetry. Methods: Dose scoring with a GPU-based MC CBCT simulator was validated on an imaging bench using a modified 16 cm CTDI phantom with 7 ion chamber shafts along the central ray for 80–100 kVp (+2 mm Al, +0.2 mm Cu). Dose distributions were computed in a segmented CBCT reconstruction of an anthropomorphic head phantom with 4×10{sup 5} tracked photons per scan (5 min runtime). Circular orbits with angular span ranging from short scan (180° + fan angle) to full rotation (360°) were considered for fixed total mAs per scan. Two aluminum filters were investigated: aggressive bowtie, and moderate bowtie (matched to 16 cm and 32 cm water cylinder, respectively). Results: MC dose estimates showed strong agreement with measurements (RMSE<0.001 mGy/mAs). A moderate (aggressive) bowtie reduced the dose, per total mAs, by 20% (30%) at the center of the head, by 40% (50%) at the eye lens, and by 70% (80%) at the posterior skin entrance. For the no bowtie configuration, a short scan reduced the eye lens dose by 62% (from 0.08 mGy/mAs to 0.03 mGy/mAs) compared to full scan, although the dose to spinal bone marrow increased by 40%. For both bowties, the short scan resulted in a similar 40% increase in bone marrow dose, but the reduction in the eye lens was more pronounced: 70% (90%) for the moderate (aggressive) bowtie. Conclusions: Dose maps obtained with validated MC simulation demonstrated dose reduction in sensitive structures (eye lens and bone marrow) through combination of short-scan trajectories and bowtie filters. Xiaohui Wang and David Foos are employees of Carestream Health.

60 APPLIED LIFE SCIENCES↗

SU-F-T-629: Effect of Multi-Leaf Collimator (MLC) Width On Plan Quality of Single-Isocenter VMAT Intracranial Stereotactic Radiosurgery for Multiple Metastases

Purpose: Single-isocenter VMAT has been shown able to create high quality plans for complex intracranial multiple metastasis SRS cases. Linacs capable of the technique are typically outfitted with an MLC that consists of a combination of 5 mm and 10 mm leaves (standard) or 2.5 mm and 5 mm leaves (high-definition). In this study, we test the hypothesis that thinner collimator leaves are associated with improved plan quality. Methods: Ten multiple metastasis cases were identified and planned for VMAT SRS using a 10 MV flattening filter free beam. Plans were created for a standard (std) and a high-definition (HD) MLC. Published values for leaf transmission factor and dosimetric leaf gap were utilized. All other parameters were invariant. Conformity (plan and individual target), moderate isodose spill (V50%), and low isodose spill (mean brain dose) were selected for analysis. Results: Compared to standard MLC, HD-MLC improved overall plan conformity (median: Paddick CI-HD = 0.83, Paddick CI-std = 0.79; p = 0.004 and median: RTOG CI-HD =1.18, RTOG CI-std =1.24; p = 0.01 ), improved individual lesion conformity (median: Paddick CI-HD,i =0.77, Paddick CI-std,i =0.72; p < 0.001 and median: RTOG CI-HD,i = 1.28, RTOG CI-std,i =1.35; p < 0.001), improved moderate isodose spill (median: V50%-HD = 37.0 cc, V50%-std = 45.7 cc; p = 0.002), and improved low dose spill (median: dmean-HD = 2.90 Gy, dmean-std = 3.19 Gy; p = 0.002). Conclusion: For the single-isocenter VMAT SRS of multiple metastasis plans examined, use of HD-MLC modestly improved conformity, moderate isodose, and low isodose spill compared to standard MLC. However, in all cases we were able to generate clinically acceptable plans with the standard MLC. More work is need to further quantify the difference in cases with higher numbers of small targets and to better understand any potential clinical significance. This research was supported in part by Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

SU-G-IeP4-10: Microimaging for Different Degrees of Human Cavernous Hemangioma of Liver by Using In-Line Phase-Contrast Imaging CT

Purpose: Cavernous hemangioma of the liver (CHL) is the most common benign solid tumor of the liver. In this study, we quantitative assessment the different degrees of CHL from microscopic viewpoint by using in-line phase-contrast imaging CT (ILPCI-CT). Methods: The experiments were performed at x-ray imaging and biomedical application beamline (BL13W1) of Shanghai Synchrotron Radiation Facility (SSRF) in China. Three typical specimens at different stages, i.e., mild, moderate and severe human CHL were imaged using ILPCI-CT at 16keV without contrast agents. The 3D visualization of different degrees of CHL samples were presented using ILPCI-CT. Additionally, quantitative evaluation of the CHL features, such as the range of hepatic sinusoid equivalent diameters in different degrees of CHL samples, the ratio of the hepatic sinusoid to the CHL tissue, were measured. Results: The planar image clearly displayed the dilated hepatic sinusoids in microns. There was no normal hepatic vascular found in the all CHL samples. Different stages of CHL samples were presented with vivid shapes and stereoscopic effects by using 3D visualization. The equivalent diameters of hepatic sinusoids in three degrees CHL were different. The equivalent diameters of the hepatic sinusoids in mild CHL, range from 60 to 120 µm. The equivalent diameters of the hepatic sinusoids in moderate CHL, range from 65 to 190 µm. The equivalent diameters of the hepatic sinusoids in severe CHL, range from 95 to 215 µm. The ratio of the hepatic sinusoid to the mild, moderate and severe CHL tissue were 3%, 16% and 21%, respectively. Conclusion: The results show that the high degree of sensitivity of the ILPCI-CT technique and demonstrate the feasibility of accurate visualization of different stage human CHL. ILPCI-CT may offers a potential use in non-invasive study and analysis of CHL.

60 APPLIED LIFE SCIENCES↗

WE-H-207A-05: Spatial Co-Localization of F-18 NaF Vs. F-18 FDG Defined Disease Volumes

Purpose: Both [F-18]NaF and [F-18]FDG show promise for quantitative PET/CT assessment in metastatic prostate cancer to bone. Broad agreement between the tracers has been shown but voxel-wise correspondence has not been explored in depth. This study evaluates the spatial co-localization of [F-18]NaF PET and [F-18]FDG PET in bone lesions. Methods: Seventy-three lesion contours were identified in six patients receiving dynamic NaF PET/CT and FDG PET/CT scans two hours apart using identical fields-of-view. Tracer uptake (SUV) reflecting 60 minutes post-injection was modeled from kinetic parameters. Lesions were segmented by a physician separately on NaF PET and FDG PET. PET images were rigidly aligned using skeletal references on CT images. Lesion size, degree of overlap, voxel-wise tracer uptake values (SUV), and CT density distributions were compared using Dice coefficient, Positive Predictive Value (PPV), and Spearman rank correlation tests. Results: Across all patients, 42 lesions were identified on NaF PET (median 1.4 cm{sup 3}, range <1–204 cm{sup 3}) compared to 31 using FDG PET (median 1.8 cm{sup 3}, range <1–244 cm{sup 3}). Spatial cooccurrence was found in 25 lesion pairs. Lesions on NaF PET had PPV of 0.91 and on FDG a PPV of 0.65. Overall, NaF-defined lesions were 47% (±24%) larger by volume with moderate overlap to FDG, resulting in mean Dice coefficient of 34% (±22%). In areas of overlap, voxel-wise correlation of NaF and FDG SUV was moderate (ρ=0.56). Expanding to regions of non-spatial overlap, voxels contained in FDG-only contours were almost exclusively low HU (median 118), compared to dense regions of NaF-only voxels (median 250). In sclerotic sub-volumes (HU > 300) NaF-defined contours encompassed 83% of total FDG volume. Conclusion: Moderate voxel-wise correlation of FDG and NaF PET/CT uptake was observed. Spatial discrepancies in FDG and NaF PET/CT imaging of boney metastases could be influenced by poor sensitivity of FDG PET/CT in sclerotic regions. Funded by Prostate Cancer Foundation.

60 APPLIED LIFE SCIENCES↗

Experiments towards a neutron target for measurements in inverse kinematics

Neutron-induced reactions play an important role in fundamental nuclear physics, nuclear astrophysics, and applications. In the case of reactions on rare isotopes, there are limited options for direct experimental measurements. The Neutron Target Demonstrator project at Los Alamos National Laboratory seeks to test the feasibility of moderating spallation neutrons within a 1 m 3 graphite cube to create a standing neutron target for neutron-induced reaction measurements in inverse kinematics. This paper presents the results of experimental neutron flux distribution tests using neutron sources (ranging from 1 keV to 50 MeV) created by accelerators at the University of Notre Dame and Texas A&M University. Measurements were made with both the full graphite cube as well as a ”half cube” setup in which half of the graphite cube was removed. The measured distributions agree with simulated distributions in the case of the full cube moderator, although there remain discrepancies in certain cases for the half cube moderator. The results shown here will provide useful information for an upcoming experimental campaign to test the neutron target proof-of-principle.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

ENDF/B-VIII.1: Thermal Neutron Scattering Sublibrary

The thermal neutron scattering law (TSL) sublibrary aims to describe the interaction of incident neutrons at thermal or sub-thermal energies with different compound materials such fuels, moderators and special-purpose materials. In ENDF/B-VIII.1 there was a large number of new and updated TSL evaluations, including traditional moderators (light water, Beryllium metal, Beryllium Oxide, Calcium Hydride, plastics (Polystyrene and Lucite), graphite (reactor-grade and crystalline), anhydrous Hydrogen Fluoride, and heavy paraffinic oil); exotic moderators (Beryllium Carbide, Zirconium Hydride, Yttrium Hydride, Lithium-7 Hydride and Deuteride), FLiBe molten salt, structural materials and cladding (Silicon Carbide, Silicon Dioxide, Zirconium Carbide), fuels (Plutonium Dioxide, Uranium Carbide, Uranium metal, Uranium Nitride, Uranium Dioxide, Uranium Hydride), and special purpose materials. In ENDF/B-VIII.1 we also distribute alongside the evaluated files, a comma-separated file (CSV), named TSL_MAT_numbers.csv, which lists all evaluated files in the current release and their corresponding unique MAT number.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Hydrogen transport in yttrium hydride under asymmetric heat

Metal hydrides are a promising moderator material for high temperature fission reactors. Yttrium hydride can be loaded to a high hydrogen density with relatively high hydrogen stability at temperatures up to 800°C. This makes yttrium hydride a potential moderator material for microreactors as foreseen in the fission surface power program. However, during the operation of such advanced reactors temperature gradients are expected which can change the local hydrogen density in the moderator. Hydrogen diffusion in metals is driven by a concentration gradient (Fick’s law) and thermal diffusion (Soret diffusion). Thermal diffusion is the transport of hydrogen, or other species, due to a temperature gradient. For example, hydrogen might migrate from the hot side of a sample to the cold side of a sample. Measuring Fickian diffusion is achieved through various permeation or absorption experiments, however measuring thermal diffusion is challenging and has rarely been performed. The Hydrogen Experimental Apparatus for Thermal Diffusion (HEATD) experiment is designed to induce thermal diffusion in samples and quench those samples so that the hydrogen distribution can be analyzed using hot vacuum extraction (HVE). One side of the sample was heated to a high temperature e.g., 800°C, while the other side of the sample is at a lower temperature. The sample was held under the applied temperature gradient for a given time until the anticipated hydrogen diffusion has occurred. The actual time depends depend on the sample composition and hydrogen concentration. The results from HVE showed that thermal diffusion took place in the specimen and the Soret coefficient was calculated.

36 MATERIALS SCIENCE↗

Transformational challenge reactor design characteristics

The Transformational Challenge Reactor (TCR) program was conceived with the goal to reduce costs and time frames associated with advanced reactor deployment by leveraging developments in advanced manufacturing, advanced materials, data science, and rapid prototyping and testing. The final deliverable of the TCR program was to be an operational test of a novel reactor design. The TCR core design incorporates a dense tri-structural-isotropic/SiC fuel form and volumetrically efficient yttrium hydride moderator, both of which were manufactured and characterized under the TCR program. The TCR is a 3 MW{sub th} He-cooled experimental nuclear reactor designed to reach a total integrated burnup of less than 24 effective full-power hours to keep the radioactive source term to a very low level. TCR design process revealed a positive moderator coefficient; however, the negative doppler coefficients for the fuel and thermal expansion of fuel, moderator, and core support plate yield an overall negative reactivity coefficient. Calculated fuel element temperatures and stresses are well within safety margins. The maximum hypothetical accident (i.e., de-pressurized loss of forced cooling) yields only a modest increase in reactor temperatures that are all within safety margins. This paper summarizes the high-level TCR design characteristics, which were derived from neutronics, thermohydraulics, thermomechanics, and safety analyses.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Evaluation of Thermal Neutron Scattering Cross Sections for CaH 2

Solid metal hydrides have long been considered viable moderators for nuclear reactor designs due to their moderating ratios, hydrogen densities, high dissociation temperatures, and mechanical properties. CaH 2 is an orthorhombic saline-hydride that has recently been investigated and shows promise for use as a moderator in microreactors. At present, there is no Thermal Scatting Law (TSL) evaluation for CaH 2 in the ENDF/B-VIII.0 database. An evaluation does exist in the JEFF-3.3 database, performed by Serot, however it was limited by the implemented methods and thus both drastically over-predicts the incoherent elastic contribution and completely ignores the coherent elastic contribution to scattering from the metal ions. The thermal neutron scattering cross sections of CaH 2 are evaluated in this work to establish accurate data for use in reactor design. The present evaluation corrects the inaccuracies of the JEFF-3.3 data, and yields three distinct libraries: Ca in CaH 2 , H 1 in CaH 2 , and H 2 in CaH 2 .

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Rossi-alpha Analysis of CURIE Experiment

Critical assembly measurement and operations are crucial to the development of benchmark data to support research into criticality safety, radiation-detection development, and the overall application of nuclear technologies. Accurate nuclear data are needed for accurate predictive simulations, and validation using critical experiments is an important part of the nuclear data pipeline. The accuracy of nuclear data are improved using more robust and targeted measurements. In particular, the intermediate energy range of uranium is of great interest. LANL has successfully performed the Zeus series of experiments on the Comet assembly to investigate the intermediate energy range for HEU with various moderators. A successor to these experiments is the benchmark for the Critical Unresolved Region Integral Experiment (CURIE), designed to be sensitive to the unresolved resonance region (URR). This experiment is designed using polytetrafluoroethylene, more commonly known as Teflon, moderators. The CURIE experiment was successfully conducted at the National Criticality Experiments Research Center (NCERC). The Rossi-alpha method was used to evaluate the propensity of the CURIE configurations to sustain fission chains by estimating the prompt neutron decay constant α. This work evaluates the α at delayed critical using Rossi-alpha for different Teflon moderator thicknesses in the CURIE experiment. These results will help improve understanding of the CURIE benchmark experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Expression of the T Helper 17-Associated Cytokines IL-17A and IL-17F in Asthma and COPD

Asthma and COPD are characterized by airway dysfunction and infl ammation. Neutrophilic airway infl ammation is a common feature of COPD and is recognized in asthma, particularly in severe disease. The T helper (Th) 17 cytokines IL-17A and IL-17F have been implicated in the development of neutrophilic airway infl ammation, but their expression in asthma and COPD is uncertain. Methods: We assessed IL-17A and IL-17F expression in the bronchial submucosa from 30 subjects with asthma, 10 ex-smokers with mild to moderate COPD, and 27 nonsmoking and 14 smoking control subjects. Sputum IL-17 concentration was measured in 165 subjects with asthma and 27 with COPD. Results: The median (interquartile range) IL-17A cells/mm 2 submucosa was increased in mild to moderate asthma (2.1 [2.4]) compared with healthy control subjects (0.4 [2.8]) but not in severe asthma (P = .04). In COPD, IL-17A + cells/mm 2 submucosa were increased (0.5 [3.7]) compared with nonsmoking control subjects (0 [0]) but not compared with smoking control subjects (P = .046). IL-17F + cells/mm 2 submucosa were increased in severe asthma (2.7 [3.6]) and mild to moderate asthma (1.6 [1.0]) compared with healthy controls subjects (0.7 [1.4]) (P = .001) but was not increased in subjects with COPD. IL-17A and IL-17F were not associated with increased neutrophilic inflammation, but IL-17F was correlated with the submucosal eosinophil count (rs = 0.5, P = .005). The sputum IL-17 concentration in COPD was increased compared with asthma (2 [0–7] pg/mL vs 0 [0–2] pg/mL, P < .0001) and was correlated with post-bronchodilator FEV 1 % predicted (r = -0.5, P = .008) and FEV 1 /FVC (r = -0.4, P = .04). Our findings support a potential role for the Th17 cytokines IL-17A and IL-17F in asthma and COPD, but do not demonstrate a relationship with neutrophilic inflammation

60 APPLIED LIFE SCIENCES↗