Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “measurement errors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

Experimental comparison of icing cloud instruments

Icing cloud instruments were tested in the spray cloud Icing Research Tunnel (IRT) in order to determine their relative accuracy and their limitations over a broad range of conditions. It was found that the average of the readings from each of the liquid water content (LWC) instruments tested agreed closely with each other and with the IRT calibration; but all have a data scatter (+ or - one standard deviation) of about + or - 20 percent. The effect of this + or - 20 percent uncertainty is probably acceptable in aero-penalty and deicer experiments. Existing laser spectrometers proved to be too inaccurate for LWC measurements. The error due to water runoff was the same for all ice accretion LWC instruments. Any given laser spectrometer proved to be highly repeatable in its indications of volume median drop size (DVM), LWC and drop size distribution. However, there was a significant disagreement between different spectrometers of the same model, even after careful standard calibration and data analysis. The scatter about the mean of the DVM data from five Axial Scattering Spectrometer Probes was + or - 20 percent (+ or - one standard deviation) and the average was 20 percent higher than the old IRT calibration. The + or - 20 percent uncertainty in DVM can cause an unacceptable variation in the drag coefficient of an airfoil with ice; however, the variation in a deicer performance test may be acceptable.

Olsen, W.↗

CAD of control systems: Application of nonlinear programming to a linear quadratic formulation

The familiar suboptimal regulator design approach is recast as a constrained optimization problem and incorporated in a Computer Aided Design (CAD) package where both design objective and constraints are quadratic cost functions. This formulation permits the separate consideration of, for example, model following errors, sensitivity measures and control energy as objectives to be minimized or limits to be observed. Efficient techniques for computing the interrelated cost functions and their gradients are utilized in conjunction with a nonlinear programming algorithm. The effectiveness of the approach and the degree of insight into the problem which it affords is illustrated in a helicopter regulation design example.

Fleming, P.↗

AE aeronomy studies

Chemical processes in the thermosphere and ionosphere using AE data were studied. These data were analyzed and interpreted in such a way as to verify and correct laboratory measured rate coefficients, obtain values for rate coefficients not measured in the laboratory, and to reveal and correct inadequacies in existing models of thermospheric chemistry. This activity stimulated new work in the laboratory measurement of rate coefficients by revealing errors in existing measurements and by suggesting new measurements that need to be made.

Walker, J. C. G.↗

Jitter in SS 433-A clue to the collimation mechanism

The blue and red shift jitter observed in SS 433 is examined with a view to determining its sources. The jitter is characterized by a Delta-z rms amplitude of 0.01, corresponding to a 3000 km/sec Doppler velocity, which is larger than either the width or the error of measurement of the shifted lines. In addition, the amplitude of the jumps is not strongly dependent on the phase in the 164-day cycle, and the amplitudes of the jitter in the redshifted and blueshifted branches are comparable. It is shown that these features set strong constraints on models proposed for SS 433 by Sarazin et al. (1980), Katz (1980), and Van den Heuvel et al. (1980).

Katz, J. I.↗

Satellite sensing capabilities for surface temperature and meteorological parameters over the ocean

Remote meteorological measurements over the oceans have been used extensively for weather forecasting, ship safety, and global-scale studies of climate and sea conditions. A review is conducted regarding the satellite-sensing capabilities for sea-surface temperature and tropospheric marine meteorological mesurements. The tropospheric measurements are concerned with vertical temperature profiles, integrated water vapor and liquid water, rain, aerosols and surface winds. Attention is also given to several environmental-monitoring applications where satellite sensed synoptic data might be combined with ground and airborne chemical measurements to provide improved assessments of regional and global ennvironmental quality and climatology. Special emphasis is given to current satellite measurement accuracies (errors) and to programs involving U.S. technology. Aspects of sea-surface temperature are treated in detail in connection with extensive studies concentrated in this area.

Darnell, W. L.↗

The design and analysis of single flank transmission error testor for loaded gears

Due to geometrical imperfections in gears and finite tooth stiffnesses, the motion transmitted from an input gear shaft to an output gear shaft will not have conjugate action. In order to strengthen the understanding of transmission error and to verify mathematical models of gear transmission error, a test stand that will measure the transmission error of a gear pair at operating loads, but at reduced speeds would be desirable. This document describes the design and development of a loaded transmission error tester. For a gear box with a gear ratio of one, few tooth meshing combinations will occur during a single test. In order to observe the effects of different tooth mesh combinations and to increase the ability to load test gear pairs with higher gear ratios, the system was designed around a gear box with a gear ratio of two.

Houser, D. R.↗

Automation of assertion testing - Grid and adaptive techniques

Assertions can be used to automate the process of testing software. Two methods for automating the generation of input test data are described in this paper. One method selects the input values of variables at regular intervals in a 'grid'. The other, adaptive testing, uses assertion violations as a measure of errors detected and generates new test cases based on test results. The important features of assertion testing are that: it can be used throughout the entire testing cycle; it provides automatic notification of error conditions; and it can be used with automatic input generation techniques which eliminate the subjectivity in choosing test data.

Andrews, D. M.↗

Effect of hand-arm exercise on venous blood constituents during leg exercise

Contributions by ancillary hand and arm actions to the changes in blood constituents effected by leg exercises on cycle ergometer were assessed. Static or dynamic hand-arm exercises were added to the leg exercise (50 percent VO2 peak)-only control regimens for the subjects (19-27 yr old men) in the two experimental groups. Antecubital venous blood was analyzed at times 0, 15, and 30 min (T0, T15, and T30) for serum Na(+), K(+), osmolality, albumin, total CA(2+), and glucose; blood hemoglobin, hematocrit, and lactic acid; and change in plasma volume. Only glucose and lactate values were affected by additional arm exercise. Glucose decreased 4 percent at T15 and T30 after static exercise, and by 2 percent at T15 (with no change at T30) after dynamic arm exercise. Conversely, lactic acid increased by 20 percent at T30 after static exercise, and by 14 percent by T15 and 6 percent at T30 after dynamic arm exercise. It is concluded that additional arm movements, performed usually when gripping the handle-bar on the cycle ergometer, could introduce significant errors in measured venous concentrations of glucose and lactate in the leg-exercised subjects.

Wong, N.↗

Calculation and accuracy of ERBE scanner measurement locations

The Earth Radiation Budget Experiment (ERBE) uses scanning radiometers to measure shortwave and longwave components of the Earth's radiation field at about 40 km resolution. It is essential that these measurements be accurately located at the top of the Earth's atmosphere so they can be properly interpreted by users of the data. Before the launch of the ERBE instrument sets, a substantial emphasis was placed on understanding all factors which influence the determination of measurement locations and properly modeling those factors in the data processing system. After the launch of ERBE instruments on the Earth Radiation Budget Satellite and NOAA 9 spacecraft in 1984, a coastline projection method was developed to assess the accuracy of the algorithms and data used in the location calculations. Using inflight scanner data and the coastline detection technique, the measurement location errors are found to be smaller than the resolution of the scanner instruments. This accuracy is well within the required location knowledge for useful science analysis.

Hoffman, Lawrence H.↗

Estimation of blade airloads from rotor blade bending moments

A method is developed to estimate the blade normal airloads by using measured flap bending moments; that is, the rotor blade is used as a force balance. The blade's rotation is calculated in vacuum modes and the airloads are then expressed as an algebraic sum of the mode shapes, modal amplitudes, mass distribution, and frequency properties. The modal amplitudes are identified from the blade bending moments using the Strain Pattern Analysis Method. The application of the method is examined using simulated flap bending moment data that have been calculated for measured airloads for a full-scale rotor in a wind tunnel. The estimated airloads are compared with the wind tunnel measurements. The effects of the number of measurements, the number of modes, and errors in the measurements and the blade properties are examined, and the method is shown to be robust.

Bousman, William G.↗

ASTROS - High-performance CCD tracker for spacecraft

The architecture, capabilities, and testing of the Advanced Star and Target Reference Optical Sensor (ASTROS) I and II are described. The ASTROS I tracker is to be utilized for a UV telescope experiment on a Shuttle flight and is capable of measuring pointing errors of 1.5 microrad, and the ASTROS II tracker is being developed for the Mariner Mark II spacecraft to perform tracking, guiding, and optical navigation functions. The requirements for the two trackers are compared. Consideration is given to star and target tracking, optical navigation, and mass and power constraints. The compositions of the trackers, in particular the sensor, electrode drives, amplifiers and signal clamp, video signal processor, control and timing generator, memories, microprocessor, and interface, are examined.

Dennison, E. W.↗

Decoding of DBEC-TBED Reed-Solomon codes

A problem in designing semiconductor memories is to provide some measure of error control without requiring excessive coding overhead or decoding time. In LSI and VLSI technology, memories are often organized on a multiple bit (or byte) per chip basis. For example, some 256 K bit DRAM's are organized in 32 K x 8 bit-bytes. Byte-oriented codes such as Reed-Solomon (RS) codes can provide efficient low overhead error control for such memories. However, the standard iterative algorithm for decoding RS codes is too slow for these applications. The paper presents a special decoding technique for double-byte-error-correcting, triple-byte-error-detecting RS codes which is capable of high-speed operation. This technique is designed to find the error locations and the error values directly from the syndrome without having to use the iterative algorithm to find the error locator polynomial.

Deng, Robert H.↗

On the accuracy of solving triangular systems in parallel

An error complexity analysis of two algorithms for solving a unit-diagonal triangular system is given. The results show that the unusual sequential algorithm is optimal in terms of having the minimal maximum and cumulative error complexity measures. The parallel algorithm described by Sameh and Brent is shown to be essentially equivalent to the optimal sequential one. Some numerical experiments are also taught.

Tsao, Nai-Kuan↗

Evaluation of ERBE scanner pointing accuracy based upon a coastline detection algorithm

Measurements from the Earth Radiation Budget Experiment (ERBE) scanning radiometers must be accurately located at the top of the Earth's atmosphere for proper interpretation of derived longwave and shortwave components of the Earth radiation field. The accuracy of the location calculations is affected by the orbit characteristics and attitude control systems of the three spacecraft, ERBS, NOAA-9, and NOAA-10. A technique was developed which makes use of the longwave scanner measurements to detect the thermal gradients at the boundaries of ocean and land masses. By analyzing many such coastline boundaries, estimates of the overall accuracy of the scanner measurement location calculations have been derived for the three satellites. The resulting measurement location errors are found to be smaller than the resolution of the radiometers, and this accuracy is well within the required location knowledge for useful science analysis of the ERBE scanner data.

Weaver, William L.↗

On the equivalence of Gaussian elimination and Gauss-Jordan reduction in solving linear equations

A novel general approach to round-off error analysis using the error complexity concepts is described. This is applied to the analysis of the Gaussian Elimination and Gauss-Jordan scheme for solving linear equations. The results show that the two algorithms are equivalent in terms of our error complexity measures. Thus the inherently parallel Gauss-Jordan scheme can be implemented with confidence if parallel computers are available.

Tsao, Nai-Kuan↗

Stabilized fiber-optic frequency distribution system

A technique for stabilizing reference frequencies transmitted over fiber-optic cable in a frequency distribution system is discussed. The distribution system utilizes fiber-optic cable as the transmission medium to distribute precise reference signals from a frequency standard to remote users. The stability goal of the distribution system is to transmit a 100-MHz signal over a 22-km fiber-optic cable and maintain a stability of 1 part in 10(17) for 1000-second averaging times. Active stabilization of the link is required to reduce phase variations produced by environmental effects, and is achieved by transmitting the reference signal from the frequency standard to the remote unit and then reflecting back to the reference unit over the same optical fiber. By comparing the phase of the transmitted and reflected signals at the reference unit, phase variations of the remote signal can be measured. An error voltage derived from the phase difference between the two signals is used to add correction phase.

Primas, L. E.↗