Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “load tests”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

Buckling test of a 3-meter-diameter corrugated graphite-epoxy ring-stiffened cylinder

A three m diameter by three m long corrugated cylindrical shell with external stiffening rings was tested to failure by buckling. The corrugation geometry for the graphite epoxy composite cylinder wall was optimized to withstand a compressive load producing an ultimate load intensity of 157.6 kN/m without buckling. The test method used to produce the design load intensity was to mount the specimen as a cantilevered cylinder and apply a pure bending moment to the end. A load introduction problem with the specimen was solved by using the BOSOR 4 shell of revolution computer code to analyze the shell and attached loading fixtures. The cylinder test loading achieved was 101 percent of design ultimate, and the resulting mass per unit of shell wall area was 1.96 kg/sq m.

Davis, R. C.↗

An examination of the aerodynamic moment on rotor blade tips using flight test data and analysis

The analysis CAMRAD/JA is used to model two aircraft, a Puma with a swept-tip blade and a UH-60A Black Hawk. The accuracy of the analysis in predicting the torsion loads is assessed by comparing the predicted loads with measurements from flight tests. The influence of assumptions in the analytical model is examined by varying model parameters and comparing the predicted results to baseline values for the torsion loads. Flight test data from a research Puma are used to identify the source of torsion loads. These data indicate that the aerodynamic section moment in the region of the blade tip dominates torsion loading in high-speed flight. Both the aerodynamic section moment at the blade tip and the pitch-link loads are characterized by large positive (nose-up) moments in the first quadrant with rapid reversal of load so that the moment is negative in the second quadrant. Both the character and magnitude of this loading are missed by the CAMRAD/JA analysis.

Maier, Thomas H.↗

Small to Full-Height Scale Comparisons of Cesium Ion Exchange Performance with Crystalline Silicotitanate

Crystalline silicotitanate (CST) ion exchanger is planned to be used to remove cesium (137Cs) from the aqueous phases of Hanford tank wastes in preparation for vitrification at the Waste Treatment and Immobilization Plant (WTP) Pretreatment Facility. Column scale up testing was conducted to evaluate performance of Cs exchange onto the CST. Batch contact testing was conducted to assess exchange kinetics of Cs exchange at four different CST PSDs. Column testing was conducted at three column sizes, small (2.5% full height), medium (12% full height), and full height, to assess Cs load performance behavior. Testing at the small scale was compared to actual Hanford tank waste testing to verify the validity of simulant tests to accurately represent full height column performance. A change in CST particle size was essential in scaling the small column dynamics up to full scale. Based on these results, a determination of intraparticle and film diffusion impacts on overall mass transfer coefficients will allow future modeling of the breakthrough performance at a range of process conditions.

Westesen, Amy M.↗

Distribution of SLS Integrated Load Uncertainty to Surface Pressures and Sectional Loads

Aerodynamic loads that are important to launch vehicle programs such as NASA’s Space Launch System (SLS) include both integrated loads such as the force & moment on the entire vehicle and distributed loads. In this work two examples of distributed loads are considered: the pressure field on the surface of the vehicle and sectional loads, which are one-dimensional distributions along the axis of the launch vehicle. In some modern flight programs, the integrated loads, such as lift and drag, used to design the guidance and control laws for the vehicle come from wind tunnel testing, while distributed loads are produced using Computational Fluid Dynamics(CFD). The first task that is addressed in this paper, then, is to provide a formal method to adjust the distributed loads so that integrating them matches the prescribed integrated load. In addition, the integrated loads in a launch vehicle typically include an uncertainty estimate. The second task is to distribute this prescribed integrated uncertainty to each point in a distributed load. Both tasks are addressed using the same technique, which is to create distributed load profiles that isolate adjustments to one integrated load while leaving the others unaffected. These adjustments are informed by Proper Orthogonal Decomposition (POD) of the entire CFD-based distributed load database. Once applied, the adjusted distributed loads can be used to evaluate any scalar quantity of interest that might be needed by downstream users such as structural analysis or trajectory modelers.

SLS↗

Development of Composite Sandwich Bonded Longitudinal Joints for Space Launch Vehicle Structures

The NASA Composite Technology for Exploration (CTE) Project is developing and demonstrating critical composite technologies with a focus on composite bonded joints; incorporating materials, design/analysis, manufacturing, and tests that utilize NASA’s expertise and capabilities. The project has goals of advancing composite technologies and providing lightweight structures to support future NASA exploration missions. In particular, the CTE project will demonstrate weight-saving, performance-enhancing composite bonded joint technology for Space Launch System (SLS)-scale composite hardware. Advancements from the CTE project may be incorporated as future block upgrades for SLS structural components. This paper discusses the details of the development of a composite sandwich bonded longitudinal joint for a generic space launch vehicle structure called the CTE Point Design. The paper includes details of the design, analysis, materials, manufacturing, and testing of sub-element joint test articles to test the capability of the joint design. The test results show that the composite longitudinal bonded joint design significantly exceeds the design loads with a 2.0 factor of safety. Analysis pre-test failure predictions for all sub-element bonded joint test coupons were all within 10% of the average test coupon failure load. This testing and analysis provides confidence in the potential use of composite bonded joints for future launch vehicle structures.

Segal, Kenneth N.↗

Space station docking mechanism dynamic testing

A prototype docking mechanism for the Space Station was designed and fabricated for NASA. This docking mechanism is actively controlled and uses a set of electromechanical actuators for alignment and load attenuation. Dynamic tests are planned using the Marshall Space Flight Center's 6-DOF Motion Simulator. The proposed tests call for basic functionality verification as well as complete hardware-in-the-loop docking dynamics simulations.

Howsman, Thomas G.↗

Methods for data reduction and loads analysis of Space Shuttle Solid Rocket Booster model water impact tests

The methodology used to predict full scale space shuttle solid rocket booster (SRB) water impact loads from scale model test data is described. Tests conducted included 12.5 inch and 120 inch diameter models of the SRB. Geometry and mass characteristics of the models were varied in each test series to reflect the current SRB baseline configuration. Nose first and tail first water entry modes were investigated with full-scale initial impact vertical velocities of 40 to 120 ft/sec, horizontal velocities of 0 to 60 ft/sec., and off-vertical angles of 0 to plus or minus 30 degrees. The test program included a series of tests with scaled atmospheric pressure.

Source record↗

Optimal Design and Damage Tolerance Verification of an Isogrid Structure for Helicopter Application

A composite isogrid panel design for application to a rotorcraft fuselage is presented. An optimum panel design for the lower fuselage of the rotorcraft that is subjected to combined in-plane compression and shear loads was generated using a design tool that utilizes a smeared-stiffener theory in conjunction with a genetic algorithm. A design feature was introduced along the edges of the panel that facilitates introduction of loads into the isogrid panel without producing undesirable local bending gradients. A low-cost manufacturing method for the isogrid panel that incorporates these design details is also presented. Axial compression tests were conducted on the undamaged and low-speed impact damaged panels to demonstrate the damage tolerance of this isogrid panel. A combined loading test fixture was designed and utilized that allowed simultaneous application of compression and shear loads to the test specimen. Results from finite element analyses are presented for the isogrid panel designs and these results are compared with experimental results. This study illustrates the isogrid concept to be a viable candidate for application to the helicopter lower fuselage structure.

Baker, Donald J.↗

Research study on multi-KW-DC distribution system

A detailed definition of the HVDC test facility and the equipment required to implement the test program are provided. The basic elements of the test facility are illustrated, and consist of: the power source, conventional and digital supervision and control equipment, power distribution harness and simulated loads. The regulated dc power supplies provide steady-state power up to 36 KW at 120 VDC. Power for simulated line faults will be obtained from two banks of 90 ampere-hour lead-acid batteries. The relative merits of conventional and multiplexed power control will be demonstrated by the Supervision and Monitor Unit (SMU) and the Automatically Controlled Electrical Systems (ACES) hardware. The distribution harness is supported by a metal duct which is bonded to all component structures and functions as the system ground plane. The load banks contain passive resistance and reactance loads, solid state power controllers and active pulse width modulated loads. The HVDC test facility is designed to simulate a power distribution system for large aerospace vehicles.

Berkery, E. A.↗

Utilizing Photogrammetry and Strain Gage Measurement to Characterize Pressurization of Inflatable Modules

This paper focuses on integrating a large hatch penetration into inflatable modules of various constructions. This paper also compares load predictions with test measurements. The strain was measured by utilizing photogrammetric methods and strain gages mounted to select clevises that interface with the structural webbings. Bench testing showed good correlation between strain data collected from an extensometer and photogrammetric measurements, even when the material transitioned from the low load to high load strain region of the curve. The full-scale torus design module showed mixed results as well in the lower load and high strain regions. After thorough analysis of photogrammetric measurements, strain gage measurements, and predicted load, the photogrammetric measurements seem to be off by a factor of two.

Mohammed, Anil↗

Propulsion System Development for the Iodine Satellite (iSAT) Demonstration Mission

The development and testing of a 200-W iodine-fed Hall thruster propulsion system that will be flown on a 12-U CubeSat is described. The switch in propellant from more traditional xenon gas to solid iodine yields the advantage of high density, low pressure propellant storage but introduces new requirements that must be addressed in the design and operation of the propulsion system. The thruster materials have been modified from a previously-flown xenon Hall thruster to make it compatible with iodine vapor. The cathode incorporated into this design additionally requires little or no heating to initiate the discharge, reducing the power needed to start the thruster. The feed system produces iodine vapor in the propellant reservoir through sublimation and then controls the flow to the anode and cathode of the thruster using a pair of proportional flow control valves. The propellant feeding process is controlled by the power processing unit, with feedback control on the anode flow rate provided through a measure of the thruster discharge current. Thermal modeling indicates that it may be difficult to sufficiently heat the iodine if it loses contact with the propellant reservoir walls, serving to motivate future testing of that scenario to verify the modeling result and develop potential mitigation strategies. Preliminary, short-duration materials testing has thus-far indicated that several materials may be acceptable for prolonged contact with iodine vapor, motivating longer-duration testing. A propellant loading procedure is presented that aims to minimize the contaminants in the feed system and propellant reservoir. Finally, an 80-hour duration test being performed to gain experience operating the thruster over long durations and multiple restarts is discussed.

Polzin, Kurt A.↗

Characterization of secondary ignition sources in unattended compartments and full-scale baseline test

The characteristics of five fuel loads burned within a metal lavatory were identified. In 15 of the tests the lavatory door remained closed for the 30-minute test period while in 15 additional tests the door was opened after the fire had developed. Upon completion of these tests the most severe source was selected for use in the baseline test. In the baseline test, the lavatory and adjacent panels, all of which were constructed of contemporary materials, were tested for a period of 1 hour. Thermal, environmental, and biological data were obtained for all fuel loads, door conditions, and the baseline test. All tests were conducted in a cabin fire simulator with separate ventilation of the cabin and lavatory representative of an inflight condition. The baseline test established that by using the most severe fuel source: (1) the exposed animal subject survived without complications; (2) no toxic levels of gas within the cabin were detected; (3) a propagating fire did not develop in adjacent structures; (4) the lavatory containing the fire remained structurally intact; (5) decomposition of portions of the lavatory did occur; and (6) cabin visibility would have presented a problem after 5 minutes.

Klink, D. M.↗

The effect of matrix mechanical properties on (0)8 unidirectional SiC/Ti composite fatigue resistance

The relationship between constituent and MMC properties in fatigue loading is investigated with low-cycle fatigue-resistance testing of an alloy Ti-15-3 matrix reinforced with SiC SCS-6 fibers. The fabrication of the composite is described, and specimens are generated that are weak and ductile (WD), strong and moderately ductile (SM), or strong and brittle (SB). Strain is measured during MMC fatigue tests at a constant load amplitude with a load-controlled waveform and during matrix-alloy fatigue tests at a constant strain amplitude using a strain-controlled waveform. The fatigue resistance of the (0)8 SiC/Ti-15-3 composite is found to be slightly influenced by matrix mechanical properties, and the composite- and matrix-alloy fatigue lives are not correlated. This finding is suggested to relate to the different crack-initiation and -growth processes in MMCs and matrix alloys.

Gabb, T. P.↗

Experimental Observations of Damage States in Unnotched and Notched 3D Orthogonal Woven Coupons Loaded in Tension

This paper describes a series of unnotched and notched tensile tests on two 3D orthogonal woven architectures. Dog bone specimens were used for the unnotched tests, and open-hole specimens were used for the notched tests. For each architecture and test type, two specimens were loaded under monotonic displacement control to failure and two specimens were incrementally loaded to failure in five steps. X-ray computed tomography (CT) was used to characterize the woven architecture and defects on each specimen prior to testing. Digital image correlation (DIC) images were obtained from both sides of the specimen throughout the loading and unloading. Acoustic emission (AE) data were also continuously acquired throughout the loading. For the incremental tests, X-ray CT was used to document the damage progression after each load increment. The damage progression was analyzed based on the results from these three techniques. The results for both architectures and test specimens followed a pattern where matrix cracks formed at the surface perpendicular to the tensile load direction. New surface cracks formed continuously throughout the loading and cracks extended in depth and width. In general, fiber failure was not detected until specimen failure.

Wade C Jackson↗

TPSAS-NF1676L-13678-DND

An area that shows promise in enhancing structural integrity of aircraft and aerospace structures is integral stitched composite technology. The most recent generation of this technology is the Pultruded Rod Stitched Efficient Unitized Structure (PRSEUS) concept. The goal of the PRSEUS concept is to provide damage-containment capability for composite structures while reducing overall structural weight. The National Aeronautics and Space Administration, the Boeing Company, and the Federal Aviation Administration (FAA) have partnered in an effort to assess the damage-containment features of a full-scale curved PRSEUS panel using the FAA Full-Scale Aircraft Structural Test Evaluation and Research facility. The background, test plan, fixture modifications, pre-test analysis, and planned experimental procedure were presented at the 2011 Aircraft Airworthiness and Sustainment Conference. This follow-on paper and presentation will provide details of the experimental procedure, test results, nondestructive inspection results, and preliminary test analysis comparison. The test program included three phases of loading and inspections: Phase I, as-built; Phase II, with barely visible impact damage (BVID); and Phase III, with a two-bay notch severing the central stiffener. Axial tension, internal pressure, and combined axial tension and internal pressure load conditions were applied during each phase using load levels that demonstrate compliance with the strength, deformation, and damage-tolerance requirements of Title 14 Code of Federal Regulations Part 25. Pressure loads were based on an operating pressure of 9.2 psi, designated as 1P, and the axial loads were based on a design limit load (DLL) of 227 kip. The Phase I test results provided a baseline. First, 50 percent limit-load levels were applied for each of the three load cases to verify proper load introduction and repeatability by examining strain and displacement results. Next, three limit-load cases were applied: limit pressure of 12.2 psi (1.33 P), axial DLL of 227 kip, and combined 1P pressure and axial DLL. Linear strain and displacement results were observed in all load cases. For Phase-II testing, the panel was impacted to introduce BVID with an energy of 40 ft-lb, with the impact located between the central stringer stitch line and flange edge. The impact created non-penetrating visual damage with fiber breaks and delamination between the skin and stringer flange. Limit-load conditions were applied followed by pressure overload of 18.4 psi (2P) and ultimate load conditions, defined as 1.5 times DLL. Inspections were performed after each load case; no damage growth was observed. For Phase-III testing, a two-bay notch was machined severing the central stiffener. The panel was then subjected to limit-load conditions, followed by combined 1P pressure while increasing axial tension load to catastrophic failure. As limit combined loads were approached, damage initiation was observed in the form of 45? splitting at 1P + 79% DLL. Axial loading was increased to 1P + 150 percent DLL causing damage to propagate to the adjacent stringer flanges. Damage was contained within the two-bay region by the stitching rows up to 1P + 176% DLL. Axial load was further increased until catastrophic failure, when a stringer rod failed at 1P + 192% DLL. These test results further verify the damage containment features of the PRSEUS concept and suggest its appropriateness for future flight vehicles.

Andrew Bergan↗

A comparison of constant-load and constant-deflection stress-corrosion tests on precracked DCB specimens

A comparison is made between measurements of stress-corrosion crack propagation made by a constant-load procedure and by a constant-deflection procedure. Precracked double cantilever beam specimens from 7075 aluminum alloy plate were used. The specimens were oriented in such a way that cracking would begin in the short-transverse plane and would propagate in the rolling direction. The specimens were subjected to a buffered salt-chromate solution and a 3.6% synthetic sea salt solution. The measurements were made optically with a binocular microscope. Stress intensities and crack lengths were calculated and crack velocities were obtained. Velocity was plotted against the average calculated stress intensity. Good agreement between the two methods was found for the salt-chromate solution, although some descrepancies were noted for the artificial sea salt solution.

Dorward, R. C.↗

A study of the core module simulator floor capability

The floor of the Core Module Simulator (CMS) is required to support various combinations of dead load and live load during the testing process. Even though there is published data on the structural capability of the grating, it is not always evident if the combined loadings with joint loads will cause structural failure.

Foreman, James W.↗

A Miniature Force Sensor for Prosthetic Hands

Tactile sensing is an important part of the development of new prosthetic hands. A number of approaches to establishing an afferent pathway back to the patient for tactile information are becoming available including tactors and direct stimulation of the afferent nerves. Tactile information can also be used by low-level control systems that perform simple tasks for the patient such as establishing a stable grasp and maintaining the grasping forces needed to hold an object. This abstract reports on the design of a small fingertip load cell based on semi-conductor strain gauges. Since this load cell is so small (measuring only 8.5mm in diameter and 6.25 mm in height), it easily fits into the tip of an anthropomorphic mechatronic hand. This load cell is tested by comparing a time series of force and moment data with reference data acquired from a much larger high-precision commercial load cell.

Platt, Robert↗