Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “histogram”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

A patch-based pseudo-CT approach for MRI-only radiotherapy in the pelvis

Purpose: In radiotherapy based only on magnetic resonance imaging (MRI), knowledge about tissue electron densities must be derived from the MRI. This can be achieved by converting the MRI scan to the so-called pseudo-computed tomography (pCT). An obstacle is that the voxel intensities in conventional MRI scans are not uniquely related to electron density. The authors previously demonstrated that a patch-based method could produce accurate pCTs of the brain using conventional T{sub 1}-weighted MRI scans. The method was driven mainly by local patch similarities and relied on simple affine registrations between an atlas database of the co-registered MRI/CT scan pairs and the MRI scan to be converted. In this study, the authors investigate the applicability of the patch-based approach in the pelvis. This region is challenging for a method based on local similarities due to the greater inter-patient variation. The authors benchmark the method against a baseline pCT strategy where all voxels inside the body contour are assigned a water-equivalent bulk density. Furthermore, the authors implement a parallelized approximate patch search strategy to speed up the pCT generation time to a more clinically relevant level. Methods: The data consisted of CT and T{sub 1}-weighted MRI scans of 10 prostate patients. pCTs were generated using an approximate patch search algorithm in a leave-one-out fashion and compared with the CT using frequently described metrics such as the voxel-wise mean absolute error (MAE{sub vox}) and the deviation in water-equivalent path lengths. Furthermore, the dosimetric accuracy was tested for a volumetric modulated arc therapy plan using dose–volume histogram (DVH) point deviations and γ-index analysis. Results: The patch-based approach had an average MAE{sub vox} of 54 HU; median deviations of less than 0.4% in relevant DVH points and a γ-index pass rate of 0.97 using a 1%/1 mm criterion. The patch-based approach showed a significantly better performance than the baseline water pCT in almost all metrics. The approximate patch search strategy was 70x faster than a brute-force search, with an average prediction time of 20.8 min. Conclusions: The authors showed that a patch-based method based on affine registrations and T{sub 1}-weighted MRI could generate accurate pCTs of the pelvis. The main source of differences between pCT and CT was positional changes of air pockets and body outline.

60 APPLIED LIFE SCIENCES↗

Feasibility of MRI-only treatment planning for proton therapy in brain and prostate cancers: Dose calculation accuracy in substitute CT images

Purpose: Magnetic resonance imaging (MRI) is increasingly used for radiotherapy target delineation, image guidance, and treatment response monitoring. Recent studies have shown that an entire external x-ray radiotherapy treatment planning (RTP) workflow for brain tumor or prostate cancer patients based only on MRI reference images is feasible. This study aims to show that a MRI-only based RTP workflow is also feasible for proton beam therapy plans generated in MRI-based substitute computed tomography (sCT) images of the head and the pelvis. Methods: The sCTs were constructed for ten prostate cancer and ten brain tumor patients primarily by transforming the intensity values of in-phase MR images to Hounsfield units (HUs) with a dual model HU conversion technique to enable heterogeneous tissue representation. HU conversion models for the pelvis were adopted from previous studies, further extended in this study also for head MRI by generating anatomical site-specific conversion models (a new training data set of ten other brain patients). This study also evaluated two other types of simplified sCT: dual bulk density (for bone and water) and homogeneous (water only). For every clinical case, intensity modulated proton therapy (IMPT) plans robustly optimized in standard planning CTs were calculated in sCT for evaluation, and vice versa. Overall dose agreement was evaluated using dose–volume histogram parameters and 3D gamma criteria. Results: In heterogeneous sCTs, the mean absolute errors in HUs were 34 (soft tissues: 13, bones: 92) and 42 (soft tissues: 9, bones: 97) in the head and in the pelvis, respectively. The maximum absolute dose differences relative to CT in the brain tumor clinical target volume (CTV) were 1.4% for heterogeneous sCT, 1.8% for dual bulk sCT, and 8.9% for homogenous sCT. The corresponding maximum differences in the prostate CTV were 0.6%, 1.2%, and 3.6%, respectively. The percentages of dose points in the head and pelvis passing 1% and 1 mm gamma index criteria were over 91%, 85%, and 38% with heterogeneous, dual bulk, and homogeneous sCTs, respectively. There were no significant changes to gamma index pass rates for IMPT plans first optimized in CT and then calculated in heterogeneous sCT versus IMPT plans first optimized in heterogeneous sCT and then calculated on standard CT. Conclusions: This study demonstrates that proton therapy dose calculations on heterogeneous sCTs are in good agreement with plans generated with standard planning CT. An MRI-only based RTP workflow is feasible in IMPT for brain tumors and prostate cancers.

60 APPLIED LIFE SCIENCES↗

Sci-Thur PM – Colourful Interactions: Highlights 05: Opal–the Oncology Patient Application

We describe Opal (Oncology portal and application), the mobile phone app and patient portal that we have developed and are deploying for Radiation Oncology patients at our cancer centre. Opal is a novel tool to empower patients with their own personal medical data, including appointment schedules, consultation notes, test results, radiotherapy treatment planning information and wait time management. Furthermore, due to its integration with our electronic medical record and treatment planning database, Opal will allow us to collect patient reported outcomes from consenting patients and link them directly with dose volume histograms and other treatment data.

60 APPLIED LIFE SCIENCES↗

Sci-Thur PM – Colourful Interactions: Highlights 07: Canadian Computed Tomography Survey: National Diagnostic Reference Levels

Purpose: The Canadian Computed (CT) Tomography Survey sought to collect CT technology and dose index data (CTDI and DLP) at the national level in order to establish national diagnostic reference levels (DRLs) for seven common CT examinations of standard-sized adults and pediatric patients. Methods: A single survey booklet (consisting of four sections) was mailed to and completed for each participating CT scanner. Survey sections collected data on (i) General facility and scanner information, (ii) routine protocols (as available), (iii) individual patient data (as applied) and (iv) manual CTDI measurements. Results: Dose index (CTDIvol and DLP) and associated patient data from 24 280 individual patient exam sequences was analyzed for seven common CT examinations performed in Canada: Adult Head, Chest, Abdomen/Pelvis, and Chest/Abdomen/Pelvis, and Pediatric Head, Chest, and Abdomen. Pediatric examination data was sub-divided into three age ranges: 0–3, 3–7 and 7–13 years. DRLs (75th percentile of dose index distributions) were found for all thirteen groups. Further analysis also permitted segmentation of examination data into 8 sub-groups, whose dose index data was displayed along with group histograms – showing relative contribution of axial vs. helical, contrast use (C+ vs. C-), and application of fixed current vs. dose reduction (DR) – 75th percentiles of DR sub-groups were, in almost all cases, lower than whole group (examination) DRLs. Conclusions: The analysis and summaries presented in the pending survey report can serve to aid local CT imaging optimization efforts within Canada and also contribute further to international efforts in radiation protection of patients.

60 APPLIED LIFE SCIENCES↗

Poster – 12: Radiological assessment of the secondary barrier shielding for IMRT treatments delivered through patient inhomogeneities

Purpose: To assess the impact of radiation treatment delivery through patient inhomogeneities on the secondary barrier shielding requirements in IMRT treatments using Monte Carlo Simulations. Materials and Methods: Scatter factors were calculated at a distance of 1m from the center of a virtual phantom in Geant4.10.01. Phantom (30×30×30 cm{sup 3}) was inserted with lung (30×30×8 cm{sup 3}), stainless steel (5×5×5 cm{sup 3}) and aluminum (5×5×5 cm{sup 3}) to represent the inhomogeneities. Scatter factor was defined according to the NCRP-151 recommendations and was calculated for angles of 3° to 120° with respect to the beam’s central axis. A virtual radiation source, with energy sampled from a histogram representing 6 MV FFF beam, was used for irradiation with a field size of 15×15 cm{sup 2} and SSD of 100 cm. Results: Irradiation through the inhomogeneity affects the patient scattered dose. For high Z material inhomogeneities the scattered dose is reduced due to significant attenuation of the primary radiation. On the other hand if the inhomogeneity is a low Z material such as lung the scattered dose is higher by a maximum of 26%. The average increase in scatter factors for the lung phantom was 17% for angles between 3° and 63° compared to the homogeneous water phantom. Conclusions: In IMRT type treatments delivered through low density patient inhomogeneities (lung) the scattered dose increases significantly. Considering a large proportion of patients receiving radiation therapy for lung cancers the increase in the scattered dose should be incorporated in the shielding calculations for the secondary barriers.

60 APPLIED LIFE SCIENCES↗

Poster - 52: Smoothing constraints in Modulated Photon Radiotherapy (XMRT) fluence map optimization

Purpose: Modulated Photon Radiotherapy (XMRT), which simultaneously optimizes photon beamlet energy (6 and 18 MV) and fluence, has recently shown dosimetric improvement in comparison to conventional IMRT. That said, the degree of smoothness of resulting fluence maps (FMs) has yet to be investigated and could impact the deliverability of XMRT. This study looks at investigating FM smoothness and imposing smoothing constraint in the fluence map optimization. Methods: Smoothing constraints were modeled in the XMRT algorithm with the sum of positive gradient (SPG) technique. XMRT solutions, with and without SPG constraints, were generated for a clinical prostate scan using standard dosimetric prescriptions, constraints, and a seven coplanar beam arrangement. The smoothness, with and without SPG constraints, was assessed by looking at the absolute and relative maximum SPG scores for each fluence map. Dose volume histograms were utilized when evaluating impact on the dose distribution. Results: Imposing SPG constraints reduced the absolute and relative maximum SPG values by factors of up to 5 and 2, respectively, when compared with their non-SPG constrained counterparts. This leads to a more seamless conversion of FMS to their respective MLC sequences. This improved smoothness resulted in an increase to organ at risk (OAR) dose, however the increase is not clinically significant. Conclusions: For a clinical prostate case, there was a noticeable improvement in the smoothness of the XMRT FMs when SPG constraints were applied with a minor increase in dose to OARs. This increase in OAR dose is not clinically meaningful.

60 APPLIED LIFE SCIENCES↗

Technical Note: SCUDA: A software platform for cumulative dose assessment

Purpose: Accurate tracking of anatomical changes and computation of actually delivered dose to the patient are critical for successful adaptive radiation therapy (ART). Additionally, efficient data management and fast processing are practically important for the adoption in clinic as ART involves a large amount of image and treatment data. The purpose of this study was to develop an accurate and efficient Software platform for CUmulative Dose Assessment (SCUDA) that can be seamlessly integrated into the clinical workflow. Methods: SCUDA consists of deformable image registration (DIR), segmentation, dose computation modules, and a graphical user interface. It is connected to our image PACS and radiotherapy informatics databases from which it automatically queries/retrieves patient images, radiotherapy plan, beam data, and daily treatment information, thus providing an efficient and unified workflow. For accurate registration of the planning CT and daily CBCTs, the authors iteratively correct CBCT intensities by matching local intensity histograms during the DIR process. Contours of the target tumor and critical structures are then propagated from the planning CT to daily CBCTs using the computed deformations. The actual delivered daily dose is computed using the registered CT and patient setup information by a superposition/convolution algorithm, and accumulated using the computed deformation fields. Both DIR and dose computation modules are accelerated by a graphics processing unit. Results: The cumulative dose computation process has been validated on 30 head and neck (HN) cancer cases, showing 3.5 ± 5.0 Gy (mean±STD) absolute mean dose differences between the planned and the actually delivered doses in the parotid glands. On average, DIR, dose computation, and segmentation take 20 s/fraction and 17 min for a 35-fraction treatment including additional computation for dose accumulation. Conclusions: The authors developed a unified software platform that provides accurate and efficient monitoring of anatomical changes and computation of actually delivered dose to the patient, thus realizing an efficient cumulative dose computation workflow. Evaluation on HN cases demonstrated the utility of our platform for monitoring the treatment quality and detecting significant dosimetric variations that are keys to successful ART.

60 APPLIED LIFE SCIENCES↗

Phase transitions in the two-dimensional ferro- and antiferromagnetic potts models on a triangular lattice

The phase transitions in the two-dimensional ferro- and antiferromagnetic Potts models with q = 3 states of spin on a triangular lattice are studied using cluster algorithms and the classical Monte Carlo method. Systems with linear sizes L = 20-120 are considered. The method of fourth-order Binder cumulants and histogram analysis are used to discover that a second-order phase transition occurs in the ferromagnetic Potts model and a first-order phase transition takes place in the antiferromagnetic Potts model. The static critical indices of heat capacity ({alpha}), magnetic susceptibility ({gamma}), magnetization ({beta}), and correlation radius index ({nu}) are calculated for the ferromagnetic Potts model using the finite-size scaling theory.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Phase transitions in the antiferromagnetic Ising model on a body-centered cubic lattice with interactions between next-to-nearest neighbors

Phase transitions in the antiferromagnetic Ising model on a body-centered cubic lattice are studied on the basis of the replica algorithm by the Monte Carlo method and histogram analysis taking into account the interaction of next-to-nearest neighbors. The phase diagram of the dependence of the critical temperature on the intensity of interaction of the next-to-nearest neighbors is constructed. It is found that a second-order phase transition is realized in this model in the investigated interval of the intensities of interaction of next-to-nearest neighbors.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Phase transitions and critical properties in the antiferromagnetic Ising model on a layered triangular lattice with allowance for intralayer next-nearest-neighbor interactions

The phase transitions (PTs) and critical properties of the antiferromagnetic Ising model on a layered (stacked) triangular lattice have been studied by the Monte Carlo method using a replica algorithm with allowance for the next-nearest-neighbor interactions. The character of PTs is analyzed using the histogram technique and the method of Binder cumulants. It is established that the transition from the disordered to paramagnetic phase in the adopted model is a second-order PT. Static critical exponents of the heat capacity (α), susceptibility (γ), order parameter (β), and correlation radius (ν) and the Fischer exponent η are calculated using the finite-size scaling theory. It is shown that (i) the antiferromagnetic Ising model on a layered triangular lattice belongs to the XY universality class of critical behavior and (ii) allowance for the intralayer interactions of next-nearest neighbors in the adopted model leads to a change in the universality class of critical behavior.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Critical Properties of the Anisotropic Ising Model with Competitive Interactions in the Region of a Phase Transition from the Modulated Phase to the Paramagnetic One

Monte Carlo methods are used to study the anisotropic Ising model with competing interactions in the region of the phase transition from the modulated to the paramagnetic phase. Using histogram analysis of Monte Carlo data and the theory of finite-size scaling, it is shown that the transition from the modulated state to the paramagnetic one is a second-order phase transition. The critical parameters and temperatures of phase transitions in this region are calculated. It is shown that the modulated–paramagnetic phase transition cannot be described within the framework of the known universality classes of critical behavior.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Phase Transitions and Thermodynamic Properties of the Potts Model with Spin States Number q = 4 on a Hexagonal Lattice

Phase transitions and thermodynamic properties of the 2D ferromagnetic Potts model with the number of spin states q = 4 on a hexagonal lattice are investigated by the Mote Carlo method based on the Wang–Landau algorithm. The orders of the phase transitions are investigated using the Binder fourth-order cumulant method and histogram analysis of data. It is established that a first-order transition is observed in the model being investigated.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Structure and optical properties of ZnO with silver nanoparticles

Textured nanocrystalline ZnO thin films are synthesized by ion beam assisted deposition. According to X-ray diffraction data, the crystallite size is ∼25 nm. Thin (∼15 nm) ZnO layers containing Ag nanoparticles are formed in a thin surface region of the films by the implantation of Ag ions with an energy of 30 keV and a dose in the range (0.25–1) × 10{sup 17} ion/cm{sup 2}. The structure and optical properties of the layers are studied. Histograms of the size distribution of Ag nanoparticles are obtained. The average size of the Ag nanoparticles varies from 0.5 to 1.5–2 nm depending on the Ag-ion implantation dose. The optical transmittance of the samples in the visible and ultraviolet regions increases, as the implantation dose is increased. The spectra of the absorption coefficient of the implanted films are calculated in the context of the (absorbing film)/(transparent substrate) model. It is found that the main changes in the optical-density spectra occur in the region of ∼380 nm, in which the major contribution to absorption is made by Ag nanoparticles smaller than 0.75 nm in diameter. In this spectral region, absorption gradually decreases, as the Ag-ion irradiation dose is increased. This is attributed to an increase in the average size of the Ag nanoparticles. It is established that the broad surface-plasmon-resonance absorption bands typical of nanocomposite ZnO films with Ag nanoparticles synthesized by ion implantation are defined by the fact that the size of the nanoparticles formed does not exceed 1.5–2 nm.

36 MATERIALS SCIENCE↗

Density of States and the Ground State Structure in the Ising Model on a Kagome Lattice with Consideration for Next-Nearest-Neighbor Interaction

Phase transitions and thermodynamic properties have been studied in the two-dimensional antiferromagnetic Ising model on a Kagome lattice by the Monte Carlo method with consideration for both nearest- and next-nearest-neighbor interaction. Using the histogram data analysis method, it has been shown that the studied model is characterized by a second-order phase transition. The temperature dependence of thermodynamic parameters has been revealed to exhibit abnormal behavior.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Phase Transitions in the Antiferromagnetic Heisenberg Model on a Body-Centered Cubic Lattice with Allowance for the Next-Nearest-Neighbor Interactions

Based on the replica exchange Monte Carlo algorithm and histogram analysis of data, the phase transitions in the three-dimensional antiferromagnetic Heisenberg model on a body-centered cubic lattice with allowance for the next-nearest-neighbor interaction are studied. The study is performed for the nextnearest- neighbor exchange interaction ratio of r = 1. It is established that, for this model, the transition from the antiferromagnetic to paramagnetic phase is a first-order phase transition.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Studying Thermodynamic Properties of the Ising Model on a Body-Centered Cubic Lattice with Competing Exchange Interactions

Using the Monte Carlo method, magnetic structures of the ground state and thermodynamic properties of the antiferromagnetic Ising model on a body-centered cubic lattice with competing exchange interactions are studied. The investigations are carried out for the ratio of the exchange interactions of next and nearest neighbors r = J{sub 2}/J{sub 1} = 2/3. All possible magnetic structures of the ground state for this ratio of exchange interactions have been obtained. It has been shown that at r = 2/3 the competition of exchange interactions does not lead to the appearance of frustration and degeneracy of the ground state. Based on the histogram data analysis, it has been shown that the phase transition of the second kind is observed in the model under study at r = 2/3.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Phase Transitions and the Critical Properties of the Heisenberg Model on a Body-Centered Cubic Lattice

The Monte Carlo replica technique is used to study phase transitions and the thermodynamic and critical properties of the three-dimensional Heisenberg antiferromagnetic model on the body-centered cubic lattice with the inclusion of the interaction of the nearest and the next-nearest neighbors. The studies are performed for the proportions of the values of the exchange interactions of the nearest and the next-nearest neighbors in the range of values of k [0.0, 0.6]. The phase transition character is analyzed based on the histogram method. The overall set of static critical indices is calculated in terms of the theory of the finite-dimensional scaling. It is shown that the class of the critical behavior universality of this model is conserved in the above range of values of k.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Phase Transitions and the Thermodynamic Properties of the Potts Model with the Number of Spin States q = 4 on a Triangular Lattice

The phase transitions and the thermodynamic properties of the two-dimensional ferromagnetic Potts model with the number of spin states q = 4 on a triangular lattice are studied on the base of the Wang–Landau algorithm of the Monte Carlo method. The phase transition characters are analyzed using the method of the four-order Binder cumulants and the histogram analysis of the data. It is found that a first-order phase transition is observed in the model under study.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗