Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “heating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

Induction Heating of Trash Reactor (OSCAR)

Induction heating is one of the standard processes used in the manufacturing industry to heat conductive materials using induced currents. Due to its efficiency, this heating method has reached other industries such as common household appliances. Currently, the majority of the heating methods used in the KSC laboratory rely on resistive heating for its heating operations. This project aims to study the benefits of the induction heating method being applied to heating processes in current laboratory projects. Potential benefits of this study include increase in heating efficiency, reduced power consumption, and speed of operations.

Jaime Toro↗

Assessing Urban Heat in the Cincinnati and Covington Area to Inform Local Decision-Makers and Environmental Justice Initiatives

The Urban Heat Island effect is a phenomenon characterized by urban areas experiencing temperatures that are, on average, warmer than surrounding suburban and rural regions. Urban Heat Islands are fueled by expansive impervious surfaces, vehicle emissions, and insufficient urban green space. Densely populated urban centers like the Cincinnati, Ohio and Covington, Kentucky area can experience negative health impacts due to the Urban Heat Island. NASA DEVELOP partnered with Groundwork USA and Groundwork Ohio River Valley to combine environmental education and outreach with technical capacity building in NASA Earth observations. The DEVELOP team used Landsat 5 TM and ISS ECOSTRESS to calculate daytime and nighttime land surface temperature anomalies. The team found that the Cincinnati and Covington area was 8.32°F warmer during the day and 4.97°F warmer at night compared to non-urban areas. The team also ran the Natural Capital Project InVEST Urban Cooling Model to map a heat mitigation index for the study area. The heat mitigation index models the cooling capacity of each pixel and the effect of green spaces on the pixel’s ability to mitigate heat. Results show which communities are most vulnerable to impacts of increased urban heat. The team also assessed alternative tree canopy scenarios with the InVEST model to better understand the effectiveness of potential heat mitigation strategies. Increasing tree canopy cover by 25% in urbanized land cover types was found to reduce mean temperature across the study area by 0.87°F. Combining these results with work from Groundwork’s Climate Safe Neighborhoods program highlights the relationship between extreme heat and historical-race based housing practices in the region. Results provide partners at Groundwork with refined methodologies to support future education and outreach, as well as increase future capacity to NASA Earth observations.

Celeste Gambino↗

Variance Decomposition of MEDLI2 Reconstructed Heating Using Neural Networks

The Mars Entry, Descent, and Landing Instrumentation (MEDLI2) sensor suite collected data during entry of the Mars 2020 Perseverance rover into Mars’ atmosphere. This suite included a network of MEDLI2 Instrumented Sensor Plugs (MISPs). Each MISP was comprised of a cylinder made of Thermal Protection System (TPS) material with 1-3 embedded thermocouples (TCs), and it was flush mounted into the heatshield or backshell. Data from these in-depth TCs were used to reconstruct the aeroheating environment of the vehicle throughout entry. Surface heating was posed as an inverse problem, with the goal of estimating the surface heating by minimizing an objective function of the difference between MISP temperature measurements during flight and the temperature predictions derived from the Fully Implicit Ablation and Thermal response (FIAT) program. Given an aerothermal environment, FIAT calculates the material response and provides in-depth temperatures throughout the TPS material. To achieve the reverse, an internal tool called FIAT_Opt runs through multiple different environments until the output temperature at the TC depth closely matches the flight data. 95% confidence intervals on the reconstructed surface heating were obtained using Monte Carlo analysis, in which uncertainties in the thermocouple depth and the TPS material properties (e.g., density, thermal conductivity, heat capacity, emissivity) based on flight-lot material testing were included. A variance decomposition method using Sobol indices was employed to assess the sensitivity of the reconstructed peak heating to the TC placement and material property uncertainties. Variance decomposition was found to require tens of thousands of FIAT_Opt runs in order for the Sobol indices to converge. With a single FIAT_Opt run taking on the order of 40 minutes, the required number of computations would take months to complete, even if using multiple CPUs. To mitigate this problem, three machine learning models (ridge regression with cross-validation, random forest regression, and a deep neural network) were trained and tested using the 2000 Monte Carlo runs that were already completed. A subset of 1600 runs were used to train the model (i.e., training set), while the remaining 400 runs were used as the test set. The predictions from the deep neural network (DNN) on the test set showed nearly perfect agreement to the actual values computed with FIAT_Opt (R2 > 0.99). Using the DNN as a surrogate model, the variance decomposition using 50,000 runs was completed within minutes. The resulting Sobol indices showed that the reconstructed peak surface heating was most sensitive to the uncertainties in the thermal conductivity (ST = 0.37) and heat capacity (ST = 0.26). This method can be leveraged to provide requirements for material property measurements needed to improve the accuracy of surface heating prediction and ultimately lead to the reduction of design margins in the future. This presentation will include background on the MEDLI2 suite; the method used for inverse heating estimation; the way that material property uncertainties were accounted for using Monte Carlo analysis; a brief background on variance decomposition; the motivation for using machine learning in this context; how a neural network was trained on the data to enable variance decomposition in a fraction of the time; and the variance decomposition results for one of the MISPs.

Hannah Alpert↗

Thermal Management System Modeling in the Heat Transport System Simulation (HeaTSSPy) Package

This paper describes the development of a thermal management system (TMS) concept design and analysis software package called Heat Transport System Simulation (HeaTSSPy). Built within Python using the OpenMDAO framework, HeaTSSPy can be used to size and optimize an active (using liquid/air heat exchangers) or passive (using finned heat sinks) TMS. The package makes use of modular TMS elements that allow for the creation of different system architectures and includes components such as heat sinks, heat exchangers, liquid pumps, fans, ducts, air inlets, air nozzles, and liquid pipes. Modeling methods for these components include a combination of physics-based analytical and empirical equations that relate component sizing criteria to system performance. The HeatSSPy heat sink methods are fully detailed within this paper, while the heat exchanger methods are described and referenced from previous work. This paper also uses high-fidelity simulation to validate two different methods of calculating thermal resistance using CFD results. Once the methods are fully described, the code is exercised to compare an active TMS with that of a passive TMS. Design criteria for this study include rejected heat, system altitude, Mach number, and ambient temperature. These criteria are used to develop a TMS system with estimated performance metrics such as weight, drag, and operational power. Results of this paper show the crossover point when a passive system begins to weigh more than an active system for a given heat rejection.

Thermal management system↗

Vacuum Operation of Consolidated Heat Pipe (CHP) for Fission Surface Power

Consolidated Heat Pipe (CHP) is a new technology that enables direct thermal power delivery to the hot-end of a Stirling engine using a heat pipe--a two phase passive heat transfer device. CHP was developed after the efforts of the Kilopower Using Stirling TechnologY (KRUSTY) test where a heat pipe was used to deliver thermal power from a fission-basedreactor to a Stirling engine to produce 1 kWe of useable electrical power in 2018. Large thermal losses were noted during the KRUSTY test where a temperature drop of 145 °C was measured between the heat pipe’s condenser and the engine’s hot-end. The Consolidated Heat Pipe was designed to address and mitigate this temperature loss. CHP was designed, built and tested at the Glenn Research Center (GRC). The initial test was performed in ambient air conditions, and the results were presented in “Consolidation of a Sodium Heat Pipe and Stirling Engine for Fission Surface Power” at the Thermal Fluids Analysis Workshop in 2023. Researchers at GRC have tested this technology again in a vacuum environment in 2024. Results show that the heat pipe and the hot-end of the Stirling engine are isothermal with a minimal temperature differential of approximately 2.5 °C in varying operational states. The Consolidated Heat Pipe technology has proven to be an efficient way of delivering thermal power directly to Stirling engines.

Greeta J Thaikattil↗

Process Heating Assessments Using DOE’s Manufacturing Energy Assessment Software for Utility Reduction (MEASUR) Tool Suite

Process heating is the most energy-intensive manufacturing process for most sectors of industry. To quantify energy savings from various energy conservation measures, the Department of Energy (DOE) sponsored the development of the Process Heating Assessment and Survey Tool (PHAST) and similar tools for other industrial systems in the early 2000s. It has been used extensively in the Save Energy Now Program’s Energy Savings Assessments and the Better Plants Program’s In-Plant Trainings. Since the initial development of the legacy tools, both computer operating systems and software development have evolved significantly. Thus, DOE has invested in the modernization of PHAST and other legacy software tools to create the Manufacturing Energy Assessment Software for Utility Reduction (MEASUR) tool suite. MEASUR offers a collection of software tools that can aid manufacturing facilities in improving the efficiency of energy systems and equipment (specifically pumps, fans, steam, and process heating) and in conducting “Energy Treasure Hunts”. Eventually, the tool will also add compressed air and process cooling systems. The Process Heating Assessment (PHA) module of MEASUR is an upgrade of the PHAST tool. PHA provides the means to model fuel-fired, steam-based, and electric process heating systems, covering process heating for most industrial plants in manufacturing sector. It also includes several key upgrades, including the ability to consider multi-component charge loads and account for several different areas of energy losses. The new tool includes a comprehensive flue gas calculator to quantify available heat and heat loss for various gaseous, liquid, and solid fuels and new heat loss calculators. It generates a report and a dynamic Sankey diagram to show the energy consumption in various areas of energy use. MEASUR has significantly improved the user experience by adopting a modern software design. This paper details the structure and workflow of PHA and presents a real-world case study to demonstrate energy savings quantification and MEASUR’s outstanding reporting capabilities.

Nimbalkar, Sachin U.↗

Seamlessly Fuel Flexible Heat Pump with Optimal Model-based Control Strategies to Reduce Peak Demand, Utility Cost and CO2 Emission

This research develops a novel hybrid fuel heat pump system for space heating of residential and small commercial buildings with built-in optimization and control. Whereas conventional dual fuel systems either run on gas or electricity at any given moment, the proposed seamlessly fuel flexible heat pump (SFFHP) simultaneously consumes gas and electricity and continuously optimizes the proportion of each. The building air flows across the heat pump condenser first and then flows across the furnace coil, and this reduces the heat pump temperature lift. The SFFHP delivers energy savings by allowing each subsystem (gas furnace and electric heat pump) to operate where it performs best to improve energy efficiency, minimize energy cost, and minimize carbon footprint. The capacities of the electric heat pump and gas furnace are continuously adjusted based on ambient conditions, utility price signals, and marginal grid emission signals. An optimal model predictive control strategy was developed with the goal of minimizing utility cost and minimizing CO2 emission. Two case studies were conducted to simulate the performance of SFFHP during the heating season in Chicago and Los Angeles, respectively. Compared with a conventional electric heat pump, SFFHP yields 33% utility cost reduction and 49% CO2 emission reduction in Chicago. Similarly, it achieves 23% utility cost reduction and 17% CO2 emission reduction in Los Angeles. Case studies demonstrate that SFFHP can deliver significant reductions in peak demand, utility cost, and CO2 emission. Due to the hybrid fuel nature of this novel equipment, user comfort will always be maintained. The fuel flexibility makes it an attractive option for demand response programs.

Li, Zhenning↗

Cold Climate Integrated Heat Pump with Energy Storage for Grid-Responsive Control

An air-source integrated heat pump (ASIHP) is a multifunctional unit, capable of space cooling, space heating, and water heating. We developed a packaged cold climate ASIHP, using a multi-stage compressor, capable of working down to -25°C, and providing 100% rated capacity down to -15°C with a heating COP > 2.2. An innovative system configuration and related controls were developed to solve charge balance in the integrated heat pump, smooth charge migration, and mode transition among multiple working modes. Extensive laboratory investigations for individual modes were performed to verify the performance. Its integrated heating capability provides speedy water heating to meet domestic hot water use and store heating energy in a phase change material ceiling/panel. The heating energy storage can be used to shift the load when the electricity price is high. Based on the performance data and a calibrated model from the laboratory testing, we conducted building energy simulations driven by a model predictive control, using EnergyPlus in one U.S. cold climate zone to investigate the grid-responsive control strategy and estimate the utility cost reduction potential.

Shen, Bo↗

An analysis of Potential Benefits of Adding Diurnal Thermal Storage in Geothermal Heat Pump Systems

Geothermal heat pumps (GHP) are highly efficient for space heating and cooling, utilizing the subsurface of the ground as seasonal energy storage through borehole heat exchangers (i.e., heat stored in summer is used to provide heating in winter, and cold stored in winter is used to provide cooling in summer). On the other hand, diurnal thermal energy storage can actively be charged and discharged for load shifting. Conventional thermal energy storage uses tanks filled with thermal storage media (such as phase change materials) and heat exchangers. It occupies building floor space or land areas outside the building, which may not be available especially in residential buildings. This paper will introduce a novel configuration that can utilize existing GHP system for both diurnal and seasonal thermal storage. This system can actively charge the ground on daily basis by injecting heat or cold in borehole heat exchangers. A simulation model was created for the novel configuration. Computer simulations were conducted using the model for the new GHP system serving a typical single-family house in three U.S. cities representing hot, warm, and cold climates. Based on simulation results, the potential benefits of load shifting and downsize of the expensive ground heat exchangers used by the GHP system were assessed.

Anees, Fady [ORNL]↗

In Hot Water! The Challenges and Barriers of Decarbonizing Water Heating in Multifamily Buildings: Preprint

Domestic hot water heating is responsible for 32% of the total energy consumption in multifamily buildings and offers a significant decarbonization opportunity. An extensive market assessment was conducted to understand and document key technical and economic barriers to electrification of domestic water heating in multifamily buildings throughout the U.S. Through the program, 77 interviews were conducted to understand key market drivers and technical challenges associated with electrification of water heating systems in both retrofit and new construction scenarios. Interviewees encompassed a wide range of stakeholders in the ecosystem surrounding water heating systems, including suppliers, manufacturers, designers, owners, utilities, and developers. This paper documents key interview takeaways, including an extensive list of market barriers, technical challenges, and sought-after technology attributes that can inform pertinent design criteria for electric water heating research, development, and deployment efforts. Among economics and energy efficiency features, interviewees overwhelmingly alluded to space constraints, cold air exhaust, and lack of clear guidance regarding distributed versus centralized design selections as key challenges associated with mass adoption of electric water heating. Owners and developers seek systems with minimal footprint, which maximize rentable space and profits. Moreover, distributed heat pump solutions should balance ducting costs that mitigate cold exhaust entrainment into conditioned zones. Lastly, the market needs clear guidance regarding the selection of distributed versus central electric hot water systems.

challenges of water heating electrification↗

Material selection and manufacturing for high‐temperature heat exchangers: Review of state‐of‐the‐art development, opportunities, and challenges

Abstract Many energy systems demand heat transfer at high temperatures to keep up with high demand for power, so high‐temperature material that can perform and last under these harsh conditions is needed for heat exchangers. The engineering requirements for these high‐temperature heat exchanger material call for high thermal conductivity, high resistance to fracture, high resistance to creep deformation, environmental stability in environments associated with the application, and high modulus of elasticity while maintaining low cost to make and maintain. Naturally, ceramics are a good solution for this endeavor. In the past, high‐temperature heat exchangers made from ceramics have been used. We provide examples of ceramics in relevant heat exchange applications and provide motivation where additive manufacturing (AM) can improve efficiency. AM for the relevant material is under development, and we provide insight on the AM of ceramic materials and examples of AM heat exchangers keeping cost in mind. The motivation of the review paper is to provide a framework for material and manufacturing selection for high‐temperature heat exchangers for AM to keep up with the demand for better efficiency, better material, better manufacturing, and cost moving forward with AM technology in high‐temperature ceramic heat exchangers.

36 MATERIALS SCIENCE↗

Bottom-up assessment of industrial heat pump applications in U.S. Food manufacturing

Decarbonization of the industrial process heat supply through electrification could contribute significantly to climate change mitigation efforts. In the U.S. industry, thermal processes accounted for more than two-thirds of the total final energy demand in 2021. Cross-cutting electrification technologies like industrial heat pumps are suitable for the process heat supply to several industrial unit operations in a sustainable way while also improving overall energy efficiency. This study employs a bottom-up approach to investigate the techno-enviro-economic potentials of deploying high-temperature and steam-generating heat pumps in the major U.S. food manufacturing sectors in different timeframes. The results show that the annual technical potential energy and CO 2 savings by electrifying process heat supply are 325 PJ (or approximately 20% of the total final energy demand in U.S. food manufacturing) and 31 MtCO 2 (equivalent to the annual CO 2 emissions from over 6 million cars in the U.S.) in 2050, respectively; however, these incur additional costs in each sector. Although there may be individual cost-effective opportunities for electrifying heat supply in specific industrial sites, the overall costs are estimated to be high in the food sectors due to the large disparity between electricity and natural gas prices and low heat source temperatures. To overcome the identified techno-economic barriers, comprehensive action plans for different stakeholders are needed. In conclusion, this study provides novel insights that should inform policymakers’ and executives’ decisions about the electrification of the current and future U.S. industrial heat supply in relevant industrial sectors.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Wire-coil insert optimization for high-heat-load/flux synchrotron components

Many synchrotron components require high levels of internal-flow, forced-convection heat transfer to minimize surface temperatures, thermal gradients, and thermally induced stress on high-power beam-interacting surfaces. Wire-coil inserts, physically similar to a common spring, are mechanically fitted inside of component cooling passages to optimize heat transfer performance. They are routinely used in Advanced Photon Source (APS) front end and beamline high-heat-load/flux components to significantly enhance convection heat transfer-up to 400% compared to plain open passages. This has the additional benefit of greatly reducing coolant flow requirements for these components. Using several cooling passage sizes, five different wire sizes, and a range of pitch values, an experimental investigation conducted at the APS has determined the average heat transfer coefficient and resulting pressure loss as a function of water flow rate for 65 different wire-coil inserts. Data from this study have been non-dimensionalized and generalized to yield relationships that can be used to determine the heat transfer performance and resulting pressure loss for any given wire-coil insert that may be used at the APS. Through data reduction, the wire-coil insert characteristic dimensions have also been optimized to yield the highest heat transfer enhancement while minimizing the coolant flow requirements. These generalized expressions for wirecoil inserts will be presented, and they can be used by scientists and engineers during the component design process to evaluate achievable heat transfer performance and associated pressure loss, aiding in the establishment of optimized operating parameters and cooling passage flow distribution schemes.

43 PARTICLE ACCELERATORS↗

Advances in high-pressure and high-temperature heat exchangers: Innovations via additive manufacturing and their applications

This paper provides a comprehensive overview of technological developments and applications for high-pressure and high-temperature (HPHT) heat exchangers produced through additive manufacturing (AM) techniques. As the demand for high-efficiency energy systems has been rising, the role of heat exchangers for thermal management and transport is becoming increasingly crucial. In this context, AM has emerged as a promising manufacturing solution to address the challenges posed by higher operating temperatures and/or pressures. This paper delves into three primary areas: the exploration of HPHT regimes supported by conventional heat exchangers, the impact of AM processes on thermal transport devices, and the discussion focused on HPHT heat exchangers produced via AM. The study examines the traditional manufacturing processes, materials, structures and geometries, and limitations of the commonly used heat exchangers for HPHT applications. Furthermore, it highlights the potential of AM in optimizing HPHT heat exchanger design, by reviewing studies that enable uniform flow distribution, minimization of fouling, and thermo-hydraulic performance augmentation without compromising structural stability. While addressing the limitations of cost, size, and other constraints, this study offers insights into the possibilities of AM in revolutionizing HPHT heat exchanger technology. The goal has been to fill the gap in literature by summarizing key studies, findings, and limitations, presenting a detailed examination, and proposing new areas for research. In conclusion, this review contributes to a deeper understanding of AM’s role in advancing HPHT heat exchangers for future energy systems.

36 MATERIALS SCIENCE↗

Observations Indicate That Clouds Amplify Mechanisms of Southern Ocean Heat Uptake

Abstract The Southern Ocean has absorbed most of the excess heat associated with anthropogenic greenhouse gas emissions. Since Southern Ocean observations are sparse in certain regions and seasons, much of our knowledge of ocean heat uptake is based on climate model simulations. However, climate models still inadequately represent some properties of Southern Ocean clouds, and they have not identified the mechanisms by which clouds may affect Southern Ocean heat uptake (SOHU). Here, we use the ERA5 and JRA‐55 reanalyses to assess the influence of clouds and other atmospheric processes on SOHU from 1979 to 2020. We find that years with the highest SOHU between 45° and 65°S are dominated by ocean heat uptake anomalies during winter and spring, but not during summer or fall. Winter and spring cloud cover are up to 7% higher when SOHU is up to 5.5 W/m 2 higher than the climatological seasonal mean, with the largest increases in the South Pacific Ocean. Clouds also contain more liquid water. These changes in cloud properties increase downwelling longwave radiation, amplifying ocean heat uptake. Cloud changes are also concomitant with a more stable lower atmosphere, which suppresses turbulent heat fluxes out of the surface. Overall, we find that SOHU is likely not mediated by enhanced surface shortwave absorption over the observational time period. A better understanding of how atmospheric processes impact ocean heat uptake may help improve our understanding of ocean heat uptake mechanisms in the current generation of climate models.

54 ENVIRONMENTAL SCIENCES↗

Assessment of Screen-Covered Grooved Sodium Heat Pipes for Microreactor Applications

New nuclear reactor designs that incorporate heat pipes are being investigated for possible near-term deployment in terrestrial applications. Here, this study explores the use of screen-covered axially grooved sodium heat pipes and their applicability for providing heat removal for microreactors. A sodium working fluid is appropriate for microreactors operating in the 5 to 20 MW(thermal) range at approximately 650°C. HTPIPE, a legacy software code, was validated for the case of screen-covered grooves and used to perform steady-state analyses to determine the performance limits of a proposed heat pipe design. The performance limits of a sodium heat pipe with a screen-covered square grooved wick structure is compared to that of an equivalent heat pipe with an annular wick. In a horizontal orientation at an operating temperature of 650°C,the performance limits for the heat pipe with an annular wick configuration are 15% higher than for the screen-covered grooved wick. At operating temperatures below 777°C, the annular wick outperforms the screen-covered grooved wick, and at temperatures above 777°C, the screen-covered grooved wick outperforms the annular wick. However, the marginal performance gain at higher temperatures may not justify the use of heat pipes with a screen-covered grooved wick structure due to increased manufacturing costs.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Effect of air path heat losses at different locations in vapor compression-based clothes dryer: Quasi-steady modeling and design implications

Clothes drying is among the most power-intensive household end uses, and vapor compression-based clothes dryers offer substantial energy cost savings compared with conventional electric heater dryers. However, parasitic heat losses along the air path, that is, heat loss at the upstream of the drum, inside the drum, and at downstream of the drum, remain rarely quantified, but can strongly affect overall performance according to experiments. Here, this study enhances a vapor compression simulation model by integrating a validated drum model using a dimensionless heat-and-mass-transfer effectiveness correlation derived from 63 drying tests in the literature to form a quasi-steady dryer simulation model. The model is validated against laboratory measurements of a baseline dryer. The impact of heat losses is simulated at three locations and explored through 16 heat loss cases spanning two loads (2 and 5 kg), two airflow rates, and multiple loss distributions. For a 5 kg wet load, eliminating pre-drum and in-drum losses reduces total energy use by up to 34–35% and shortens drying time by 27–38% compared with the baseline. At a 2 kg wet load, introducing post-drum heat loss lowers energy costs by up to 23% and reduces operation time by up to 57% compared with the baseline. The results demonstrate that the impact of heat loss is location dependent. Vapor compression dryers should minimize pre-drum and in-drum losses while potentially exploiting post-drum heat dissipation to enhance the drying rate and energy cost savings.

Dryer↗

Experimental and Numerical Evaluation of the Thermal-Fluid Characteristics of the Helium-Cooled Modular Divertor with Multiple Jets Using a Reversed Heat Flux Approach

A single-finger unit of the Helium-Cooled Modular Divertor with Multiple Jets (HEMJ) with a plasma-facing surface (PFS) area of about 2 cm 2 has been studied in a helium (He) loop at He mass flow rates m˙ H ≤ 8 g/s and nearly prototypical conditions. Based on previous studies of the single finger of the HEMJ, our Georgia Institute of Technology group is planning to experimentally study larger divertors. Given that the HEMJ test section was heated with an induction heater and that it is impractical to scale this up to divertors with larger PFS areas, a reversed heat flux approach is being considered to measure heat transfer coefficients (HTCs). In this approach, the direction of the heat flux is reversed with water cooling and high-temperature He heating of the outer shell attached to the PFS. This work presents an initial experimental and numerical evaluation of this approach for a single HEMJ finger. Experiments with brass and copper-chromium-zirconium outer shells were conducted at dimensionless He mass flow rates or Reynolds numbers Re = 1 × 10 4 to 4.7 × 10 4 , an inlet pressure of 10 MPa, temperatures as great as 673 K, and maximum heat flux of 8.4 MW/m 2 . The experiments verify that the He-side HTCs are independent of the direction of the heat flux. Here, the results agree well with previous Nusselt number correlation and pressure loss coefficients for the HEMJ obtained using the normal heating approach.

42 ENGINEERING↗