Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “exchanger”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

Diffraction and photon exchange processes at the LHC and parton saturation

We present a review of the recent theoretical and experimental developments related to the field of diffraction, parton saturation, and forward physics. We first discuss our present understanding of the proton structure in terms of quarks and gluons, the degrees of freedom of quantum chromodynamics. We then focus on some of the main results on diffraction at the HERA electron–proton collider in DESY, Germany, at the Tevatron proton–antiproton collider at Fermilab, Batavia, US, and at the CERN Large Hadron Collider (LHC) proton–proton and nucleus–nucleus collider, which is located in Geneva, Switzerland. We also present a selected amount of results on diffraction and photon exchanges that can be done at the LHC experiments and at a future Electron Ion Collider (EIC) to be built in the US at Brookhaven National Laboratory, New York.

Physics↗

Comparison of Planar and Tubular Flow Field Plates for Proton Exchange Membrane Fuel Cells (PEMFCs) through Simulation

Proton exchange membrane fuel cells are excellent clean energy alternatives to current non-renewable energy sources. Bipolar plates are a key component of these fuel cells and directly responsible for their performance. Traditional bipolar plates are created in a planar form, but recent research has revealed a novel tubular design that performs similarly to conventional plates. Here, this study compares traditional planar designs with tubular ones. The finite element ANSYS software was used to determine and visualize velocity and pressure distributions of fluid flow through the bipolar plate channels.

25 ENERGY STORAGE↗

Editors’ Choice—Uncovering the Role of Alkaline Pretreatment for Hydroxide Exchange Membrane Fuel Cells

Alkaline pretreatment is perceived as an essential step for high-performance hydroxide exchange membrane fuel cells (HEMFCs), but its exact function is not fully understood. Here we show that alkaline pretreatment is only necessary when carboxylates are generated from platinum- or palladium-catalyzed oxidation of primary alcohol solvents during membrane electrode assembly (MEA) fabrication. When alkaline pretreatment is needed, bicarbonates are a better choice than the most commonly used hydroxide bases. We further demonstrate that MEAs with Pt/Pd-free catalysts, which can be used in HEMFCs, exhibit a better performance without the alkaline pretreatment: a voltage of 0.64 V at 1.0 A cm −2 and a peak power density of 0.69 W cm −2 in H 2 /O 2 . The optimization or elimination of the alkaline pretreatment will simplify the fabrication process for fuel cells and thus reduces their manufacturing costs.

Shi, Lin↗

Imidazolium-Type Anion Exchange Membranes for Improved Organic Acid Transport and Permselectivity in Electrodialysis

Most commercial anion exchange membranes (AEMs) deploy quaternary ammonium moieties. Alternative cation moieties have been explored in AEMs for fuel cells, but there are no studies focused examining alternative tethered cations in AEMs for ionic separations—such as organic acid anion transport via electrodialysis. H-cell and conductivity experiments demonstrate that tethered benzyl 1-methyl imidazolium groups in polysulfone AEMs enhance lactate conductivity by 49% and improved lactate anion flux by 24x when compared to a quaternary benzyl ammonium polysulfone AEM. An electrodialysis demonstration with the imidazolium-type AEM showed a 2x improvement in lactate anion flux and 20% improvement in permselectivity when benchmarked against the quaternary ammonium AEM. Molecular dynamics and 2D NOESY NMR revealed closer binding of lactate anions to the imidazolium cations when compared to the quaternary ammonium cation. It is posited that this closer binding is responsible to greater flux values observed with imidazolium-type AEM.

36 MATERIALS SCIENCE↗

Performance and Durability of Proton Exchange Membrane Vapor-Fed Unitized Regenerative Fuel Cells

With a growing demand for electricity, clean hydrogen production and usage can be an asset not only to mitigate emissions but for long-term energy storage as well. Hydrogen gas, a high-density energy carrier, can be made through electrolysis in charging mode and generate electricity via a fuel cell in discharging mode in a unitized regenerative fuel cell (URFC). While URFCs reduce cost by combining the charging and discharging modes into a singular device, switching between modes becomes burdensome, and water management is a major challenge. One way to mitigate these issues is to operate the entire system in the vapor phase. Vapor-phase operation simplifies the physics of the system but will introduce losses within the system, primarily ohmic and mass transport during the charging mode. In this study, we explore the performance of a Proton-Exchange-Membrane (PEM)-URFC under vapor-phase conditions and the impact of different PEMs, feed gases, and relative humidity on the performance and durability. By tailoring operating conditions and membrane, the vapor-URFC achieves a roundtrip efficiency of 42% and a lifetime of 50,000 accelerated stress test cycles for fully humidified feeds. Discussion of vapor-URFC for energy storage and extensions to look at various applications shows the promise of this technology.

25 ENERGY STORAGE↗

Transport of Ligand Coordinated Iron and Chromium through Cation-Exchange Membranes

Fluxes of negatively charged ligand-coordinated iron, Fe(CN) 6 3/4- , and chromium, CrPDTA 1/2− , through two promising commercial cation-exchange membranes, Aquivion E87–05S and Fumasep E-620(K), were measured as functions of current density. The magnitude of the partial current density reached a maximum of − 43 μ A cm −2 at the maximum applied current density magnitude of − 43 mA cm −2 for Fe(CN) 6 3/4− transport through Aquivion, or 0.1% of the total current density. Fumasep E-620(K) blocks practically all crossover of both compounds. Both membranes sorb more Fe(CN) 6 3/4− and CrPDTA 1/2− than predicted by Donnan equilibrium, and low crossover rates can be attributed mainly to slow diffusion, not charge-based rejection of co-ions. The magnitude of the diffusion coefficient appears to correlate with hydraulic permeability. Although Aquivion E87–05S and Fumasep E-620(K) have significant and observable differences in membrane crossover rates, cells built with the DI-soaked membranes offer similarly high coulombic efficiency, indicating the relatively small contribution that crossover makes to inefficiency over a single cycle.

25 ENERGY STORAGE↗

Pioneering Microporous Layers for Proton-Exchange-Membrane Water Electrolyzers via Tape Casting

The imperative shift towards decarbonization necessitates the production of clean hydrogen through water electrolysis, powered by renewable energy sources. Among electrolyzer technologies, proton-exchange-membrane (PEM) systems emerge as a promising option for large-scale hydrogen generation due to their modular design and rapid response, aligning well with the intermittency of renewable energy. In this study, we employ a tape casting method to fabricate microporous layers (MPLs), both as a single layer and as a bilayer over commercial porous transport layers (PTLs), to further enhance performance of water electrolyzers. We demonstrate that microporous layers require adequate pore sizes to facilitate gas removal, preventing gas flooding and preserving electrolyzer performance. Our single layer microporous layers exhibit lower overpotentials compared to commercial sintered Ti PTLs by 142 mV at 4 A·cm ⁻2 . Moreover, we show that having an effective microporous layer enhances electrolyzer performance irrespective of the substrate used, offering avenues for cost reduction. We also investigate novel PTL structures with reduced tortuosity and integrated MPL fabricated via phase inversion tape casting, resulting in a performance enhancement of 92 mV. Our findings unravel the critical role of microporous layer structures and their impact on electrolyzer performance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quantifying Sources of Long-Term Voltage Decay for Rutile Iridium Oxide Anodes in Proton Exchange Membrane Water Electrolysis

To achieve aggressive hydrogen cost targets for proton exchange membrane water electrolysis (PEMWE), it is necessary to develop catalyst systems that reduce precious metal loadings while maintaining performance over extended operation. While amorphous iridium (Ir) -based catalysts exhibit high initial activity, their long-term stability remains a key limitation. In this study, the behavior of a rutile IrO2 catalyst is investigated over 4000 h of durability testing and compared to past efforts evaluating a more amorphous material. This study finds that rutile IrO2 results in a smaller decay rate (4.9 ..mu..V h-1) than an amorphous catalyst (28 ..mu..V h-1); additionally, the rutile IrO2 results in a smaller degree of Ir migration (20% to the membrane and cathode) than an amorphous catalyst (35%). This research emphasizes rutile IrO2 as a promising avenue for the development of durable, low-iridium anodes that can meet lifetime and cost targets for next-generation electrolyzer systems.

08 HYDROGEN↗

The Impact of Catalyst Layer Properties and Transport Layer Interactions on Rutile Iridium Oxide Anode Durability in Proton Exchange Membrane Electrolysis

The performance and durability of proton exchange membrane electrolyzers are governed by the interplay between catalyst inks and integration, the resulting catalyst layer (CL) structure, and the interface between the CL and porous transport layer (PTL). In this study, we examine the impact of these factors on cell performance and degradation using rutile IrO2 as the anode catalyst. The two commercial rutile IrO2 catalysts differ from each other and from the amorphous benchmark in agglomerate size and ink stability. This has implications for CL morphology and electronic connectivity. In the context of long-term pressurized operation for up to 1000 h, the selection of the PTL has a marginal effect on the durability of CLs with good structural and compositional properties, whereas poorly structured CLs demonstrate evident degradation when used with certain PTLs. Poor CL properties amplify the negative impact of non-ideal CL/PTL interfaces, demonstrating the importance of CL/PTL interface engineering.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Reports From The Frontier: Overcoming Limitations for Pure-water Anion-exchange-membrane Electrolysis

Anion-exchange-membrane electrolysis is positioned to play a key role in the predicted exponential growth of green hydrogen technology with essential R&D advances. We reveal key design parameters essential to commercialization. First, stable alkaline oxygen-evolution reaction catalysts with high electronic conductivity and minimal surface reconstruction during operation must be designed. Alkaline catalyst layers must also be applied to the membrane electrode assembly with scalable, industrially relevant techniques. Second, ionomer oxidation mitigation strategies must be developed. Furthermore, this approach could also target other creative catalyst layer design, such as phase-separation control to protect oxidation-prone organic components or catalyst engineering to direct selectivity for hydroxide over polymer oxidation. If competitive efficiency and durability can be achieved in pure water, AEM electrolysis has the potential to become a dominant electrolyzer technology.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Mathematical Modeling of Hydroxide-Exchange-Membrane Water Electrolyzer

Water electrolyzers can transform intermittent renewable energy like solar energy and wind energy into the chemical energy of hydrogen with zero greenhouse-gas emissions. The hydroxide-exchange membrane electrolyzer (HEME) combines the capability to produce pressurized hydrogen with the advantage of being able to use low or non-platinum group metal (PGM) electrocatalysts in the alkaline environment.1 Hydroxide salts, for example, KOH, are added to the HEME water feed on both anode and cathode to improve its performance. However, the specific mechanism of performance improvement still needs to be further understood. In addition, at high current densities, bubble evolution can result in mass-transport limitations, a less well studied phenomena. Mathematical modeling is ideal to explore these issues as it is cost and time efficient and can deconvolute the physics, processes, and observed phenomena and study the applied-voltage breakdown. In this work, we extend our previously developed 1D two-phase continuum model2 to study the varies processes in the HEME and provide insights on performance optimizations. First, the oxygen evolution reaction (OER) and hydrogen evolution reaction (HER) kinetics at different hydroxide concentrations have been studied by rotating disk electrodes (RDE) and implemented in the model. Then, the model is calibrated and validated against experimental HEME polarization curves for different KOH concentrations as a liquid electrolyte. The model clearly shows a performance increase with increasing KOH concentrations, which is consistent with the experimental results. The reduced ohmic resistance and increased electrochemical active surface area (ECSA) are the two main reasons for performance increase. The large amount of hydroxide in the liquid electrolyte not only helps to distribute the reactant hydroxide throughout the catalyst layer (CL), which reduces ohmic loss, but also enables reaction at the interface between the liquid electrolyte and electrocatalyst, which increases the ECSA. Applied-voltage breakdown demonstrates that the electrolyzer performance is dominated by anode kinetics and ohmic loss. A comparison with the DI water feed shows a more uniform current distribution in the anode CL when KOH is added, which indicates a higher utilization of the CL. Second, we present modeling on the effects of bubble coverage. As gas evolves, part of the ECSA is minimized due to bubble coverage. To account for this effect, an empirical relationship between the fractional bubble coverage and the current density is implemented in the model.3 The model shows this bubble coverage effect is more pronounced at large current densities with DI water feed. Acknowledgements This work was funded under the HydroGEN Consortium by the Energy Efficiency and Renewable Energy, Hydrogen and Fuel Cell Technologies Office, of the U. S. Department of Energy under contract number DE-AC02-05CH11231. References R. Abbasi, B. P. Setzler, S. Lin, J. Wang, Y. Zhao, H. Xu, B. Pivovar, B. Tian, X. Chen, G. Wu and Y. Yan, 31, 1805876 (2019). L. N. Stanislaw, M. R. Gerhardt and A. Z. Weber, ECS Transactions, 92, 767 (2019). H. Vogt and R. J. Balzer, Electrochimica Acta, 50, 2073 (2005).

Liu, Jiangjin↗

Membrane Pretreatment and Cell Conditioning for Proton Exchange Membrane Water Electrolysis

As the research community studying proton exchange membrane water electrolysis (PEMWE) grows, it is important to develop methods that achieve transparent, reproducible research. Reproducibility of performance and durability is a challenge facing the PEMWE field, as the published literature includes a wide spread of results obtained with nominally similar materials. Prior round-robin performance benchmarking efforts [1] have identified inadequate cell conditioning as a major source of variation in apparent cell performance. Inadequate pre-treatment and conditioning can lead to instability in initial performance and adds ambiguity to durability measurements. However, excessively prolonged conditioning procedures limit the throughput of testing and the pace of research. Pretreatment and conditioning methods vary significantly across the research literature, but little systematic investigation is available into the mechanisms of these procedures or how procedural differences may impact results. This presentation will discuss investigations into the effects of membrane pre-treatment and operating procedures during cell conditioning on initial performance and catalyst-specific accelerated stress tests, with the aim of recommending procedures to enable clear, reproducible, and high-throughput research. Methods investigated include the use of hydrogen peroxide, acids, and hydration at elevated temperature for membrane pretreatment, and conditioning procedures such as current or voltage holds and cycling. The investigations cover both the impacts of these procedures on cell performance and stability as well as underlying mechanisms and processes taking place in the cell materials.

cell↗

Hydroxide Exchange Membrane Carbon Capture (HEMCC) Using Nickel Hydroxide Batteries and Flow-through Membranes

Proposed is an electrochemical nickel hydroxide based hydroxide exchange membrane carbon capture (HEMCC) device for Direct Air Capture (DAC) of CO2. DAC has been identified as one of the key net negative carbon technologies to achieve net zero carbon emissions. Net negative carbon technologies are required to offset continued emissions from dilute CO2 sources such as agriculture and construction. The majority of current DAC technologies at scale (>1 KT∙yr-1) are adsorbent based technologies with significant energy cost. The traditional DAC energy cost is primarily driven by the temperature swing required to regenerate the sorbent and has been shown to be 1.8 MWh·ton-1 at the system level. Electrochemical pH swing devices are a growing research area for carbon capture devices with the goal of lowering the energy cost required for DAC. A pH gradient is built by generating OH- at the cathode and consuming OH- at the anode. An acid-base equilibrium with CO2 allows for the capture of CO2 at the cathode and release at the anode. This extends from other electrochemical CO2 capture devices based on pKa shifts of an electrochemically active organic species allowing for the capture and release of CO2. Electrochemical CO2 capture is considered promising based on potentially low energy costs to capture CO2 in comparison with current temperature swing adsorption technologies. This work explores Ni(OH)2 electrodes to produce the pH gradient for CO2 capture and release. At the cathode NiOOH is reduced to Ni(OH)2 while at the anode Ni(OH)2 is oxidized to NiOOH. The symmetrical electrodes allow for a low voltage requirement; the thermodynamic potential difference of standard electrochemical reactions is zero. Most of the voltage observed is to produce the pH gradient with the remainder driving the polarization of the electrodes. There is a resistance component as well, but this is small in comparison due to the low current densities used in the device, nominally 2 mA·cm-1. Two similar devices are presented, a traditional MEA (membrane electrode assembly) and a flow-through MEA. The traditional MEA separates the two Ni(OH)2 electrodes with an 80μm Piperion® membrane. While the flow-through membrane separates the electrodes with a three piece membrane consisting of two 80μm Piperion® membranes with a porous membrane between them. In the traditional MEA system air is passed over the cathode for capture, while the flow-through MEA the air is passed through the porous membrane isolated from the electrodes. The traditional MEA has been used to establish a baseline performance of the device and has been shown to capture CO2 at an energy cost of 1 MWh·ton-1 at the device level. An understanding has been built around the components of that energy cost including the relationship of flux to current density, effect of a regeneration process, transient battery behavior, and gas losses coinciding with changing the polarization of the batteries. The flow-through MEA looks to address of transient battery behavior and gas losses. It allows for denser, higher capacity electrodes, which can lean on traditional Ni-MH battery technology used in alkaline batteries used today. The higher capacities, limit the transient battery effect on flux in the device. Gas losses are addressed by having a continuous inlet air stream to the device and continuous outlet product.

Buchen, James↗

Two dimensional topology optimization of heat exchangers with the volume fraction method

We perform a comparison study of two topology optimizations methods applied to the design of a two fluids heat exchanger modeled with a coupled thermal-flow problem. The flow follows an isothermal and incompressible Stokes-Brinkman equation and the heat transfer is governed by a convection-diffusion equation without internal generation and high Peclet number. To keep the two fluid phases separated, we solve two Stokes-Brinkman equations, where the Brinkman term models the other phase as a solid. These two velocity fields are then fed to the heat transfer equation. Our goal is to maximize the enthalpy at the cold outlet while constraining the pressure drop. We first solve the design modeling the solid and fluid phases with a volume fraction variable. A SIMP-like penalization in the Brinkman term drives the optimization to a discrete design. The cost and constraint function derivatives are calculated with the library pyadjoint and the optimization is performed by IPOPT. We present optimized designs in two dimensions and discuss the influence of the parameters.

Beck, VictorA.↗

$η(') → π0γγ$ decays: Test of meson exchange models and searches of leptophobic $B$ bosons

We analyze the vector and scalar meson exchange contributions to the doubly radiative decays $η(') → π0γγ$ and $η → ηγγ$, and study the sensitivity of these decays to a leptophobic B boson in the sub-GeV mass range. Our results are relevant for studies of these decays at existing (A2, BESIII, KLOE-2) and forthcoming $η/η'$-factories, such as the JEF and REDTOP experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SBML Level 3: an extensible format for the exchange and reuse of biological models

Systems biology has experienced dramatic growth in the number, size, and complexity of computational models. To reproduce simulation results and reuse models, researchers must exchange unambiguous model descriptions. We review the latest edition of the Systems Biology Markup Language (SBML), a format designed for this purpose. A community of modelers and software authors developed SBML Level 3 over the past decade. Its modular form consists of a core suited to representing reaction-based models and packages that extend the core with features suited to other model types including constraint-based models, reaction-diffusion models, logical network models, and rule-based models. The format leverages two decades of SBML and a rich software ecosystem that transformed how systems biologists build and interact with models. More recently, the rise of multiscale models of whole cells and organs, and new data sources such as single-cell measurements and live imaging, has precipitated new ways of integrating data with models. We provide our perspectives on the challenges presented by these developments and how SBML Level 3 provides the foundation needed to support this evolution.

59 BASIC BIOLOGICAL SCIENCES↗

Raw leaf gas exchange data in the Amazon basin, 2014-2016

This data package contains raw leaf gas exchange data used to support the publication "Leaf isoprene and monoterpene emission distribution across hyperdominant tree genera in the Amazon basin," Phytochemistry, in-press. Data was collected from 162 individuals, distributed among 25 botanical families and 113 species, from four sites in the Amazon. The data was collected using a modified portable photosynthesis system for environmental control coupled to a thermal desorption tube for volatile isoprenoid collections. Collected TD tube samples were analysed in Manaus, Brazil, using thermal desorption-gas chromatography-mass spectrometry (TD-GC-MS). The dataset includes both photosynthesis and isoprene/monoterpene emission rates from leaves under standard environmental conditions as well as controlled light response curves. For detailed methods and raw data, refer to the publication and related material cited in Dataset References.

54 ENVIRONMENTAL SCIENCES↗

Oxygen Reduction on Platinum-Nickel and Platinum-Cobalt Alloy Based Catalysts for High Temperature Proton Exchange Membrane Fuel Cells

Catalyst layers, with commercial PtNi/TKK (TECNiE52; platinum 46.5 wt%), PtCo/TKK (TEC36E52; platinum 45.8 wt%) catalysts, and an in-house catalyst PtNi-NC (platinum 38.4 wt%), synthesised using acoustic mixer and a tube furnace, are prepared using three different ionomers: 20 wt% Nafion®, 60 wt% polytetrafluoroethylene (PTFE), and an in-house 5 wt% ionomer (‘Ionomer X’). These inks are bar-coated onto carbon paper gas diffusion layers (GDLs), which are cut into 3 cm × 5 cm pieces. The coated layers are tested for oxygen reduction in a commercial gas diffusion electrode (GDE) test cell, FlexCell® (Gaskatel GmbH, Germany), using 85 wt% phosphoric acid at both room temperature and at 155°C. This study evaluates the polynorbornene (PNB)-based in-house ionomer performance as binder and in-house catalyst oxygen reduction reaction (ORR) activity in comparison to commercial products. The catalyst layers are characterised using X-ray diffraction (XRD) analysis, X-ray photoelectron spectroscopy (XPS), and high-angle annular dark-field scanning transmission electron microscopy (HAADF-STEM). Among the catalyst layers prepared with PTFE ionomer and tested at 155°C, the in-house catalyst demonstrates the highest ORR activity. Ionomer X proves to be a good candidate to be used as a per- and polyfluoroalkyl-free binder for high-temperature (HT) proton exchange membrane fuel cell (PEMFC) applications.

85 wt% phosphoric acid↗