Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “error estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

Measuring Interfractional and Intrafractional Motion With Cone Beam Computed Tomography and an Optical Localization System for Lower Extremity Soft Tissue Sarcoma Patients Treated With Preoperative Intensity-Modulated Radiation Therapy

Purpose: To evaluate inter- and intrafractional motion and rotational error for lower extremity soft tissue sarcoma patients by using cone beam computed tomography (CBCT) and an optical localization system. Methods and Materials: Thirty-one immobilized patients received CBCT image-guided intensity-modulated radiation therapy. Setup deviations of >3 mm from the planned isocenter were corrected. A second CBCT acquired before treatment delivery was registered to the planning CT to estimate interfractional setup error retrospectively. Interfractional error and rotational error were calculated in the left-right (LR), superoinferior (SI), and anteroposterior (AP) dimensions. Intrafractional motion was assessed by calculating the maximum relative displacement of optical localization system reflective markers placed on the patient's surface, combined with pre- and postfraction CBCT performed for 17 of the 31 patients once per week. The overall systematic error (SE) and random error (RE) were calculated for the interfractional and intrafractional motion for planning target volume margin calculation. Results: The standard deviation (SD) of the interfractional RE was 1.9 mm LR, 2.1 mm SI, and 1.8 mm AP, and the SE SD was 0.6 mm, 1.2 mm, and 0.7 mm in each dimension, respectively. The overall rotation (inter- and intrafractional) had an RE SD of 0.8{sup o} LR, 1.7{sup o} SI, and 0.7{sup o} AP and an SE SD of 1.1{sup o} LR, 1.3{sup o} SI, and 0.3{sup o} AP. The SD of the overall intrafractional RE was 1.6 mm LR, 1.6 mm SI, and 1.4 mm AP, and the SE SD was 0.7 mm AP, 0.6 mm SI, and 0.6 mm AP. Conclusions: A uniform 5-mm planning target volume margin was quantified for lower extremity soft tissue sarcoma patients and has been implemented clinically for image-guided intensity-modulated radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An evaluation of multi-fidelity methods for quantifying uncertainty in projections of ice-sheet mass change

Abstract. This study investigated the computational benefits of using multi-fidelity statistical estimation (MFSE) algorithms to quantify uncertainty in the mass change of Humboldt Glacier, Greenland, between 2007 and 2100 using a single climate change scenario. The goal of this study was to determine whether MFSE can use multiple models of varying cost and accuracy to reduce the computational cost of estimating the mean and variance of the projected mass change of a glacier. The problem size and complexity were chosen to reflect the challenges posed by future continental-scale studies while still facilitating a computationally feasible investigation of MFSE methods. When quantifying uncertainty introduced by a high-dimensional parameterization of the basal friction field, MFSE was able to reduce the mean-squared error in the estimates of the statistics by well over an order of magnitude when compared to a single-fidelity approach that only used the highest-fidelity model. This significant reduction in computational cost was achieved despite the low-fidelity models used being incapable of capturing the local features of the ice-flow fields predicted by the high-fidelity model. The MFSE algorithms were able to effectively leverage the high correlation between each model's predictions of mass change, which all responded similarly to perturbations in the model inputs. Consequently, our results suggest that MFSE could be highly useful for reducing the cost of computing continental-scale probabilistic projections of sea-level rise due to ice-sheet mass change.

54 ENVIRONMENTAL SCIENCES↗

Unrecognized Sources of Uncertainties ( USU ) in Experimental Nuclear Data

Evaluated nuclear data uncertainties reported in the literature or archived in data libraries are often perceived as unrealistic, most often because they are thought to be too small. The impact of this issue in applied nuclear science has been discussed widely in recent years. Commonly suggested causes are: poor estimates of specific error components, neglect of uncertainty correlations, and overlooked known error sources. However, instances have been reported where very careful, objective assessments of all known error sources have been made with realistic error magnitudes and correlations provided, yet the resulting evaluated uncertainties still appear to be inconsistent with observed scatter of predicted mean values. These discrepancies might be attributed to significant unrecognized sources of uncertainty ( USU ) that limit the accuracy to which these physical quantities can be determined. The objective of our work reported herein has been to develop qualitative and quantitative procedures for revealing and including USU estimates in nuclear data evaluations involving experimental input data. This paper identifies several specific clues that can be explored by evaluators in identifying the existence of USU . It then describes numerical procedures we have introduced to generate quantitative estimates of USU magnitudes. Key requirements for these procedures to be viable are that sufficient numbers of data points be available, for statistical reasons, and that additional supporting information about the measurements be provided by the experimenters. Several realistic examples are described here to illustrate these procedures and demonstrate their outcomes and limitations. Our work strongly supports the view that USU is an important issue in nuclear data evaluation, with significant consequences for applications, and that this topic warrants further investigation by the nuclear science community.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The Correlation between Halo Mass and Stellar Mass for the Most Massive Galaxies in the Universe

We present measurements of the clustering of galaxies as a function of their stellar mass in the Baryon Oscillation Spectroscopic Survey. We compare the clustering of samples using 12 different methods for estimating stellar mass, isolating the method that has the smallest scatter at fixed halo mass. In this test, the stellar mass estimate with the smallest errors yields the highest amplitude of clustering at fixed number density. We find that the PCA stellar masses of Chen et al. clearly have the tightest correlation with halo mass. The PCA masses use the full galaxy spectrum, differentiating them from other estimates that only use optical photometric information. Using the PCA masses, we measure the large-scale bias as a function of M{sub ∗} for galaxies with logM{sub ∗}⩾11.4, correcting for incompleteness at the low-mass end of our measurements. Using the abundance matching ansatz to connect dark matter halo mass to stellar mass, we construct theoretical models of b(M{sub ∗}) that match the same stellar mass function but have different amounts of scatter in stellar mass at fixed halo mass, σ{sub logM∗}. Using this approach, we find σ{sub logM∗}=0.18{sub −0.02}{sup +0.01}. This value includes both intrinsic scatter as well as random errors in the stellar masses. To partially remove the latter, we use repeated spectra to estimate statistical errors on the stellar masses, yielding an upper limit to the intrinsic scatter of 0.16 dex.

79 ASTRONOMY AND ASTROPHYSICS↗

TU-H-CAMPUS-JeP1-05: Dose Deformation Error Associated with Deformable Image Registration Pathways

Purpose: To evaluate errors associated with using different deformable image registration (DIR) pathways to deform dose from planning CT (pCT) to cone-beam CT (CBCT). Methods: Deforming dose is controversial because of the lack of quality assurance tools. We previously proposed a novel metric to evaluate dose deformation error (DDE) by warping dose information using two methods, via dose and contour deformation. First, isodose lines of the pCT were converted into structures and then deformed to the CBCT using an image based deformation map (dose/structure/deform). Alternatively, the dose matrix from the pCT was deformed to CBCT using the same deformation map, and then the same isodose lines of the deformed dose were converted into structures (dose/deform/structure). The doses corresponding to each structure were queried from the deformed dose and full-width-half-maximums were used to evaluate the dose dispersion. The difference between the FWHM of each isodose level structure is defined as the DDE. Three head-and-neck cancer patients were identified. For each patient, two DIRs were performed between the pCT and CBCT, either deforming pCT-to-CBCT or CBCT-to-pCT. We evaluated the errors associated by using either of these pathways to deform dose. A commercially available, Demons based DIR was used for this study, and 10 isodose levels (20% to 105%) were used to evaluate the errors in various dose levels. Results: The prescription dose for all patients was 70 Gy. The mean DDE for CT-to-CBCT deformation was 1.0 Gy (range: 0.3–2.0 Gy) and this was increased to 4.3 Gy (range: 1.5–6.4 Gy) for CBCT-to-CT deformation. The mean increase in DDE between the two deformations was 3.3 Gy (range: 1.0–5.4 Gy). Conclusion: The proposed DDF was used to quantitatively estimate dose deformation errors caused by different pathways to perform DIR. Deforming dose using CBCT-to-CT deformation produced greater error than CT-to-CBCT deformation.

60 APPLIED LIFE SCIENCES↗

Neural network-based single material beam-hardening correction for X-ray CT in Additive Manufacturing

Beam-hardening (BH) artifacts are ubiquitous in X-ray CT scans of dense metal additively manufactured (AM) parts. While linearization approaches are useful for correcting beam-hardened data from single material objects, they either require a calibration scan or detailed system and material composition information. In this paper, we introduce a neural network-based, material-agnostic method to correct beam-hardening artifacts. We train a neural network to map the acquired beam-hardened projection values and the corresponding estimated thickness of the part based on an initial segmentation to beam-hardening related parameters, which can be used to compute the coefficients of a linearizing correction polynomial. A key strength of our approach is that, once the network is trained, it can be used for correcting beam hardening from a variety of materials without any calibration scans or detailed system and material composition information. Furthermore, our method is robust to errors in the estimated thickness due to the typical challenge of obtaining an accurate initial segmentation from reconstructions impacted by BH artifacts. We demonstrate the utility of our method to obtain high-quality CT reconstructions from a collection of AM parts -- suppressing cupping and streaking artifacts

Rahman, Obaid↗

SU-E-T-270: Quality Control of Source Strength and Indexer Length in HDR Brachytherapy Using Sun Nuclear Mapcheck2

Purpose: The goal of this work was to evaluate Sun Nuclear MapCheck2 capability for quantitative determination of both HDR source strength and position. Predictive power of Mapcheck2 dose matrix, originated by a microSelectron-v2 source from 22mm distance, was investigated. Methods: A Mick MultiDoc phantom with the 1400mm indexer length mark aligned over MapCheck2 central detector plus two additional 5cm plastic slabs were used as a composite phantom. Dose readings were transformed by applying published source anisotropy corrections and experimentally established radial dose and relative sensitivity factors. Angular dependence was not considered. Only readings from diodes located 2cm around the central detector were evaluated. The reproducibility of a fit between transformed dose readings and the ratio of virtual source strength and the square of source-detector distance was investigated. Four parameters were considered in the model: virtual source strength, lateral, longitudinal and vertical source positions. Final source strength calibration factor was calculated from the ratio of reference measurements and results from the fit. Results: Original lateral and longitudinal source position estimations had systematic errors of 0.39mm and 0.75mm. After subtracting these errors, both source positions were predicted with a standard deviation of 0.15mm. Results for vertical positions were reproducible with a standard deviation of 0.05mm. The difference between calculated and reference source strengths from 34 independent measurement setups had a standard deviation of 0.3%. The coefficient of determination for the linear regression between known indexer lengths and results from the fit in the range 1400mm ± 5mm was 0.985. Conclusions: ource strength can be estimated with MapCheck2 at appropriate accuracy levels for quality control. Verification of indexer length with present implementation is more accurate than visual alternatives. Results can be improved by designing a coupling catheter phantom and refining relative diode calibration. Diode angular dependence in MapCheck2 does not play significant role.

07 ISOTOPE AND RADIATION SOURCES↗

CORRECTING A STATISTICAL ARTIFACT IN THE ESTIMATION OF THE HUBBLE CONSTANT BASED ON TYPE IA SUPERNOVAE RESULTS IN A CHANGE IN ESTIMATE OF 1.2%

The Hubble constant enters big bang cosmology by quantifying the expansion rate of the universe. Existing statistical methods used to estimate Hubble's constant only partially take into account random measurement errors. As a consequence, estimates of Hubble's constant are statistically inconsistent and systematically too low. Using the simplest of the existing methods to illustrate the problem, we show that the change in estimate is 1.2%. The more advanced techniques suffer from the same deficiency.

79 ASTRONOMY AND ASTROPHYSICS↗

Decay curve analysis for data error quantification in time-domain induced polarization imaging

In recent years, the time-domain induced polarization (TDIP) imaging technique has emerged as a suitable method for the characterization and the monitoring of hydrogeologic and biogeochemical processes. However, one of the major challenges refers to the resolution of the electrical images. Hence, various studies have stressed the importance of data processing, error characterization, and the deployment of adequate inversion schemes. A widely accepted method to assess data error in electrical imaging relies on the analysis of the discrepancy between normal and reciprocal measurements. Nevertheless, the collection of reciprocals doubles the acquisition time and is only viable for a limited subset of commonly used electrode configurations (e.g., dipole-dipole [DD]). To overcome these limitations, we have developed a new methodology to quantify the data error in TDIP imaging, which is entirely based on the analysis of the recorded IP decay curve and does not require recollection of data (e.g., reciprocals). The first two steps of the methodology assess the general characteristics of the decay curves and the spatial consistency of the measurements for the detection and removal of outliers. In the third and fourth steps, we quantify the deviation of the measured decay curves from a smooth model for the estimation of random error of the total chargeability and transfer resistance measurement. The error models and imaging results obtained from this methodology - in the following referred to as "decay curve analysis" - are compared with those obtained following a conventional normal-reciprocal analysis revealing consistent results. As a result, we determine the applicability of our methodology with real field data collected at the floodplain scale (approximately 12 ha) using multiple gradient and DD configurations.

58 GEOSCIENCES↗

Improving Lidar Turbulence Estimates for Wind Energy

Remote sensing devices (e.g., lidars) are quickly becoming a cost-effective and reliable alternative to meteorological towers for wind energy applications. Although lidars can measure mean wind speeds accurately, these devices measure different values of turbulence intensity (TI) than an instrument on a tower. In response to these issues, a lidar TI error reduction model was recently developed for commercially available lidars. The TI error model first applies physics-based corrections to the lidar measurements, then uses machine-learning techniques to further reduce errors in lidar TI estimates. The model was tested at two sites in the Southern Plains where vertically profiling lidars were collocated with meteorological towers. Results indicate that the model works well under stable conditions but cannot fully mitigate the effects of variance contamination under unstable conditions. To understand how variance contamination affects lidar TI estimates, a new set of equations was derived in previous work to characterize the actual variance measured by a lidar. Terms in these equations were quantified using a lidar simulator and modeled wind field, and the new equations were then implemented into the TI error model.

17 WIND ENERGY↗

Basis set expansion for inverse problems in plasma diagnostic analysis

A basis set expansion method [V. Dribinski, A. Ossadtchi, V. A. Mandelshtam, and H. Reisler, Rev. Sci. Instrum. 73, 2634 (2002)] is applied to recover physical information about plasma radiation sources from instrument data, which has been forward transformed due to the nature of the measurement technique. This method provides a general approach for inverse problems, and we discuss two specific examples relevant to diagnosing fast z pinches on the 20–25 MA Z machine [M. E. Savage, L. F. Bennett, D. E. Bliss, W. T. Clark, R. S. Coats, J. M. Elizondo, K. R. LeChien, H. C. Harjes, J. M. Lehr, J. E. Maenchen, D. H. McDaniel, M. F. Pasik, T. D. Pointon, A. C. Owen, D. B. Seidel, D. L. Smith, B. S. Stoltzfus, K. W. Struve, W. A. Stygar, L. K. Warne, J. R. Woodworth, C. W. Mendel, K. R. Prestwich, R. W. Shoup, D. L. Johnson, J. P. Corley, K. C. Hodge, T. C. Wagoner, and P. E. Wakeland, in Proceedings of the Pulsed Power Plasma Sciences Conference (IEEE, 2007), p. 979]. First, Abel inversion of time-gated, self-emission x-ray images from a wire array implosion is studied. Second, we present an approach for unfolding neutron time-of-flight measurements from a deuterium gas puff z pinch to recover information about emission time history and energy distribution. Through these examples, we discuss how noise in the measured data limits the practical resolution of the inversion, and how the method handles discontinuities in the source function and artifacts in the projected image. We add to the method a propagation of errors calculation for estimating uncertainties in the inverted solution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of Data-Driven Mesh-Model Optimization in System Thermal-Hydraulic Simulation

Quantification of nuclear power plant safety risk requires a systematic and yet practical approach to identification of accident scenarios, assessment of their likelihood and consequences. Instrumental to this goal is risk-informed safety margin characterization (RISMC) framework, whose realization requires computationally robust and affordable methods for sufficiently accurate simulation of complex multi-dimensional physical phenomena, such as turbulent and multi-phase flow. The CFD-like correlation-based codes with 3D simulation capability (e.g., GOTHIC) ensure computational efficiency using coarse mesh size and the sub-grid phenomena in the boundary layer that can be captured by adequate constitutive correlations. However, the error sources and user effects on the selection of mesh size and models lead to unpredictable simulation error, while rich High-Fidelity (HF) data from experiments and numerical simulation using validated code or DNS are not fully explored. It would be useful to have a “smart” data-driven multi-scale framework in which the low-resolution models can be “taught” to emulate high-resolution models. The objective of this work is to develop and evaluate a physical-based data-driven mesh-model optimization approach (Optimized Mesh/Model Information System, OMIS) to estimate the simulation error and give advice on the optimized selection of coarse mesh size and Low-Fidelity (LF) models for System Thermal Hydraulic (STH) simulation to achieve accuracy comparable to that of HF models. This approach takes advantages of computational efficiency of coarse-mesh simulation and application of Machine Learning (ML) algorithms.

97 MATHEMATICS AND COMPUTING↗

Exploring the scaling limitations of the variational quantum eigensolver with the bond dissociation of hydride diatomic molecules

Abstract Materials simulations involving strongly correlated electrons pose fundamental challenges to state‐of‐the‐art electronic structure methods but are hypothesized to be the ideal use case for quantum computing algorithms. To date, no quantum computer has simulated a molecule of a size and complexity relevant to real‐world applications, despite the fact that the variational quantum eigensolver (VQE) algorithm can predict chemically accurate total energies. Nevertheless, because of the many applications of moderately sized, strongly correlated systems, such as molecular catalysts, the successful use of the VQE stands as an important waypoint in the advancement toward useful chemical modeling on near‐term quantum processors. In this paper, we take a significant step in this direction. We lay out the steps, write, and run parallel code for an (emulated) quantum computer to compute the bond dissociation curves of the TiH, LiH, NaH, and KH diatomic hydride molecules using the VQE. TiH was chosen as a relatively simple chemical system that incorporates d orbitals and strong electron correlation. Because current VQE implementations on existing quantum hardware are limited by qubit error rates, the number of qubits available, and the allowable gate depth, recent studies using it have focused on chemical systems involving s and p block elements. Through VQE + UCCSD calculations of TiH, we evaluate the near‐term feasibility of modeling a molecule with d‐orbitals on real quantum hardware. We demonstrate that the inclusion of d‐orbitals and the use of the UCCSD ansatz, which are both necessary to capture the correct TiH physics, dramatically increase the cost of this problem. We estimate the approximate error rates necessary to model TiH on current quantum computing hardware using VQE + UCCSD and show them to likely be prohibitive until significant improvements in hardware and error correction algorithms are available.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Probabilistic estimation of depth-resolved profiles of soil thermal diffusivity from temperature time series

Abstract. Improving the quantification of soil thermal and physical properties is key to achieving a better understanding and prediction of soil hydro-biogeochemical processes and their responses to changes in atmospheric forcing. Obtaining such information at numerous locations and/or over time with conventional soil sampling is challenging. The increasing availability of low-cost, vertically resolved temperature sensor arrays offers promise for improving the estimation of soil thermal properties from temperature time series, and the possible indirect estimation of physical properties. Still, the reliability and limitations of such an approach need to be assessed. In the present study, we develop a parameter estimation approach based on a combination of thermal modeling, sliding time windows, Bayesian inference, and Markov chain Monte Carlo simulation to estimate thermal diffusivity and its uncertainty over time, at numerous locations and at an unprecedented vertical spatial resolution (i.e., down to 5 to 10 cm vertical resolution) from soil temperature time series. We provide the necessary framework to assess under which environmental conditions (soil temperature gradient, fluctuations, and trend), temperature sensor characteristics (bias and level of noise), and deployment geometries (sensor number and position) soil thermal diffusivity can be reliably inferred. We validate the method with synthetic experiments and field studies. The synthetic experiments show that in the presence of median diurnal fluctuations ≥ 1.5 ∘C at 5 cm below the ground surface, temperature gradients > 2 ∘C m−1, and a sliding time window of at least 4 d the proposed method provides reliable depth-resolved thermal diffusivity estimates with percentage errors ≤ 10 % and posterior relative standard deviations ≤ 5 % up to 1 m depth. Reliable thermal diffusivity under such environmental conditions also requires temperature sensors to be spaced precisely (with accuracy to a few millimeters), with a level of noise ≤ 0.02 ∘C, and with a bias defined by a standard deviation ≤ 0.01 ∘C. Finally, the application of the developed approach to field data indicates significant repeatability in results and similarity with independent measurements, as well as promise in using a sliding time window to estimate temporal changes in soil thermal diffusivity, as needed to potentially capture changes in bulk density or water content.

54 ENVIRONMENTAL SCIENCES↗

Relationship between x-ray illumination field size and flat field intensity and its impacts on x-ray imaging

Purpose: X-ray cone-beam CT (CBCT) is being increasingly used for various clinical applications, while its performance is still hindered by image artifacts. This work investigates a new source of reconstruction error, which is often overlooked in the current CBCT imaging. The authors find that the x-ray flat field intensity (I{sub 0}) varies significantly as the illumination volume size changes at different collimator settings. A wrong I{sub 0} value leads to inaccurate CT numbers of reconstructed images as well as wrong scatter measurements in the CBCT research. Methods: The authors argue that the finite size of x-ray focal spot together with the detector glare effect cause the I{sub 0} variation at different illumination sizes. Although the focal spot of commercial x-ray tubes typically has a nominal size of less than 1 mm, the off-focal-spot radiation covers an area of several millimeters on the tungsten target. Due to the large magnification factor from the field collimator to the detector, the penumbra effects of the collimator blades result in different I{sub 0} values for different illumination field sizes. Detector glare further increases the variation, since one pencil beam of incident x-ray is scattered into an area of several centimeters on the detector. In this paper, the authors study these two effects by measuring the focal spot distribution with a pinhole assembly and the detector point spread function (PSF) with an edge-spread function method. The authors then derive a formula to estimate the I{sub 0} value for different illumination field sizes, using the measured focal spot distribution and the detector PSF. Phantom studies are carried out to investigate the accuracy of scatter measurements and CT images with and without considering the I{sub 0} variation effects. Results: On our tabletop system with a Varian Paxscan 4030CB flat-panel detector and a Varian RAD-94 x-ray tube as used on a clinical CBCT system, the focal spot distribution has a measured full-width-at-half-maximum (FWHM) of around 0.4 mm, while non-negligible off-focal-spot radiation is observed at a distance of over 2 mm from the center. The measured detector PSF has an FWHM of 0.510 mm, with a shape close to Gaussian. From these two distributions, the author calculate the estimated I{sub 0} values at different collimator settings. The I{sub 0} variation mainly comes from the focal spot effect. The estimation matches well with the measurements at different collimator widths in both horizontal and vertical directions, with an average error of less than 3%. Our method improves the accuracy of conventional scatter measurements, where the scatter is measured as the difference between fan-beam and cone-beam projections. On a uniform water cylinder phantom, more accurate I{sub 0} suppresses the unfaithful high-frequency signals at the object boundaries of the measured scatter, and the SPR estimation error is reduced from 0.158 to 0.014. The proposed I{sub 0} estimation also reduces the reconstruction error from about 20 HU on the Catphan Copyright-Sign 600 phantom in the selected regions of interest to less than 4 HU. Conclusions: The I{sub 0} variation is identified as one additional error source in x-ray imaging. By measuring the focal-spot distribution and detector PSF, the authors propose an accurate method of estimating the I{sub 0} value for different illumination field sizes. The method obtains more accurate scatter measurements and therefore facilitates scatter correction algorithm designs. As correction methods for other CBCT artifacts become more successful, our research is significant in further improving the CBCT imaging accuracy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

tih_vqe [SWR-23-32]

This software supports the paper, "Exploring the scaling limitations of the variational quantum eigensolver with the bond dissociation of hydride diatomic molecules," published in the International Journal of Quantum Chemistry, whose abstract is as follows: Materials simulations involving strongly correlated electrons pose fundamental challenges to state-of-the-art electronic structure methods but are hypothesized to be the ideal use case for quantum computing. To date, no quantum computer has simulated a molecule of a size and complexity relevant to real-world applications, despite the fact that the variational quantum eigensolver (VQE) algorithm can predict chemically accurate total energies. Nevertheless, because of the many applications of moderately-sized, strongly correlated systems, such as molecular catalysts, the successful use of the VQE stands as an important waypoint in the advancement toward useful chemical modeling on near-term quantum processors. In this paper, we take a significant step in this direction. We lay out the steps, write, and run parallel code for an (emulated) quantum computer to compute the bond dissociation curves of the TiH, LiH, NaH, and KH diatomic hydride molecules using VQE. TiH was chosen as a relatively simple chemical system that incorporates d orbitals and strong electron correlation. Because current VQE implementations on existing quantum hardware are limited by qubit error rates, the number of qubits available, and the allowable gate depth, recent studies have focused on chemical systems involving s and p block elements. Through VQE + UCCSD calculations of TiH, we evaluate the near-term feasibility of modeling a molecule with d-orbitals on real quantum hardware. We demonstrate that the inclusion of d-orbitals and the use of the UCCSD ansatz, which are both necessary to capture the correct TiH physics, dramatically increase the cost of this problem. We estimate the approximate error rates necessary to model TiH on current quantum computing hardware using VQE+UCCSD and show them to likely be prohibitive until significant improvements in hardware and error correction algorithms are available.

Graf, Peter↗

Monte Carlo methods and their analysis for Coulomb collisions in multicomponent plasmas

Highlights: •A general approach to Monte Carlo methods for multicomponent plasmas is proposed. •We show numerical tests for the two-component (electrons and ions) case. •An optimal choice of parameters for speeding up the computations is discussed. •A rigorous estimate of the error of approximation is proved. -- Abstract: A general approach to Monte Carlo methods for Coulomb collisions is proposed. Its key idea is an approximation of Landau–Fokker–Planck equations by Boltzmann equations of quasi-Maxwellian kind. It means that the total collision frequency for the corresponding Boltzmann equation does not depend on the velocities. This allows to make the simulation process very simple since the collision pairs can be chosen arbitrarily, without restriction. It is shown that this approach includes the well-known methods of Takizuka and Abe (1977) [12] and Nanbu (1997) as particular cases, and generalizes the approach of Bobylev and Nanbu (2000). The numerical scheme of this paper is simpler than the schemes by Takizuka and Abe [12] and by Nanbu. We derive it for the general case of multicomponent plasmas and show some numerical tests for the two-component (electrons and ions) case. An optimal choice of parameters for speeding up the computations is also discussed. It is also proved that the order of approximation is not worse than O(√(ε)), where ε is a parameter of approximation being equivalent to the time step Δt in earlier methods. A similar estimate is obtained for the methods of Takizuka and Abe and Nanbu.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

ObstacleSense: Low-Power Neuromorphic Vision for Corridor Obstacle Awareness in Low-Level ADAS

The automotive industry’s pursuit of Level 5 autonomy is constrained by substantial perception-compute power requirements, often reaching 1, 000 + watts in full autonomy stacks. Reducing this energy burden requires rethinking perception not only at the high-end autonomy level, but also at the foundational Advanced Driver Assistance Systems (ADAS) level where low-power, safety-critical sensing can have broad impact. Neuromorphic vision provides a promising starting point: HD Dynamic Vision Sensors (DVS) can operate below 100 mW at the sensor level by reporting only asynchronous brightness changes. However, low-power sensing alone is insufficient if downstream perception reintroduces dense, energy-intensive computation. In particular, many event-driven object-detection pipelines still rely on CNN backbones, while purely spiking alternatives often trade away accuracy or ignore deployment constraints. We introduce ObstacleSense, a highly compact, CNN-free hybrid ANN–SNN framework for Level 0–1 forward-corridor obstacle awareness. Instead of performing full-scene object detection with a convolutional feature backbone, ObstacleSense targets the safety-critical question of whether the ego corridor is occupied and how far the nearest obstacle is. The architecture combines polarity-conditioned event encoding, lightweight temporal spiking dynamics, axial spatial mixing, and coarse-to-fine range estimation within a regular fixed-grid compute pattern. This design avoids the dense CNN backbone commonly used in event-based detection while maintaining a small state footprint suitable for eventual small-FPGA deployment. Before hardware mapping, we evaluate the software implementation using a model-side power proxy derived from MACs, weight and activation traffic, and spiking state updates under shared FP16 assumptions. On simulated CARLA event corpora, the deployment-oriented model achieves 0.9464 objectness F1, 0.9978 grid-level mAP, and 0.8987 m distance Mean Absolute Error at an estimated 1.92 mW proxy cost, while maintaining performance on unseen generalization test sequences.

Johnson-Scott, Zac [ORNL]↗