Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electrical distribution system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

Control approach for power modulation of end-use loads

Methods, apparatus, and systems are disclosed herein for power modulation control of power grids using end-use loads. At the beginning of a coordination period typically lasting a few minutes, a population of end-use loads (water heaters, air conditioners, plug-in electric vehicles, etc.) is interrogated for their willingness to participate in power modulation by undergoing state transitions from on to off, or off to on. Distribution system flexibilities are calculated from the sums of device powers within distribution systems. Area flexibilities are calculated from the sums of device powers within areas. Thresholds for various devices to change state in response to inter-area oscillation damping or frequency regulation are derived from these flexibilities. Two power functions are monitored in real-time and compared with the device thresholds to trigger state changes which then remain locked throughout the remainder of the coordination period, then the devices are released from the lockout state.

Lian, Jianming↗

A Path to 100 Percent Renewable Energy: Grid-Forming Inverters will Give Us the Grid We Need Now

This is a more urgent problem than it might sound. The westernmost Hawaiian island of significant size, Kauai is home to around 70,000 residents and 30,000 tourists at any given time. Renewable energy accounts for 70 percent of the energy produced in a typical year - a proportion that's among the highest in the world and that can be hard to sustain for such a small and isolated grid. During the day, the local system operator, the Kauai Island Utility Cooperative, sometimes reaches levels of 90 percent from solar alone. But on 2 April, the 26-MW generator was running near its peak output, to compensate for the drop in solar output as the sun set. At the moment when it failed, that single generator had been supplying 60 percent of the load for the entire island, with the rest being met by a mix of smaller generators and several utility-scale solar-and-battery systems.

battery management systems↗

PR100: Puerto Rico Grid Resilience and Transition to 100% Renewable Energy: Preventing and Responding to Extreme Events

This presentation discusses the aftermath of Hurricane Maria's landfall in Puerto Rico on September 20, 2017. Maria incapacitated Puerto Rico's power systems, leaving the entire island without electricity and access to fresh water. Some parts are still recovering years later. A resilient electric grid is vital to Puerto Rico's security, economy, and way of life.

demand impacts↗

Multiscale Electricity Modeling for Evaluating Carbon Capture and Sequestration Technologies (MEME-CCS)

This effort employs and adapts an existing, rigorous multiscale electricity modeling platform at the National Renewable Energy Laboratory (NREL) to evaluate carbon capture and sequestration (CCS) and negative emissions technologies (NET) from the ARPA-E FLECCS program. NREL's modeling platform includes the Regional Energy Deployment System (ReEDS) electric sector capacity expansion model, which projects future electricity generation mixes at sub-state-level resolution that are downscaled to the unit-level to enable hourly, zonal or nodal electricity production cost modeling in the PLEXOS model. The resulting hourly price data from PLEXOS is provided to technology developers under the ARPA-E FLECCS program to enable technology-specific economic analysis. The ReEDS-PLEXOS modeling suite is well-established for examining electric sector futures with high renewable energy penetrations, energy storage, electrification, and distributed generation. The key advancement proposed herein utilizes collaboration with CCS experts at the University of Wyoming and the FLECCS teams to create innovative methods for representing CCS and NET in the ReEDS and PLEXOS models. Expanded technology options, new operational parameterizations, and detailed data defining CO2 capture, transportation, and storage systems are being integrated into these models to allow an unprecedented combination of scope and resolution for exploring the future of CCS and NET. The resulting capabilities will take advantage of high-performance computing resources to permit wide-ranging scenario analysis to assess CCS and NET deployment under alternative CO2 prices, fossil fuel prices, electricity demand growth, and other electric sector characteristics. Final outcomes will include publicly available hourly grid operation and price data for any U.S. region of interest along with open-access capacity expansion tools for evaluating CCS/NET systems. These products will help an emerging CCS/NET industry in the United States by providing economics-driven guidance to technology developers while informing policy and investment decisions in the public and private sectors.

air capture↗

Brayton Power Conversion Unit Tested: Provides a Path to Future High-Power Electric Propulsion Missions

Closed-Brayton-cycle conversion technology has been identified as an excellent candidate for nuclear electric propulsion (NEP) power conversion systems. Advantages include high efficiency, long life, and high power density for power levels from about 10 kWe to 1 MWe, and beyond. An additional benefit for Brayton is the potential for the alternator to deliver very high voltage as required by the electric thrusters, minimizing the mass and power losses associated with the power management and distribution (PMAD). To accelerate Brayton technology development for NEP, the NASA Glenn Research Center is developing a low-power NEP power systems testbed that utilizes an existing 2- kWe Brayton power conversion unit (PCU) from previous solar dynamic technology efforts. The PCU includes a turboalternator, a recuperator, and a gas cooler connected by gas ducts. The rotating assembly is supported by gas foil bearings and consists of a turbine, a compressor, a thrust rotor, and an alternator on a single shaft. The alternator produces alternating-current power that is rectified to 120-V direct-current power by the PMAD unit. The NEP power systems testbed will be utilized to conduct future investigations of operational control methods, high-voltage PMAD, electric thruster interactions, and advanced heat rejection techniques. The PCU was tested in Glenn s Vacuum Facility 6. The Brayton PCU was modified from its original solar dynamic configuration by the removal of the heat receiver and retrofitting of the electrical resistance gas heater to simulate the thermal input of a steady-state nuclear source. Then, the Brayton PCU was installed in the 3-m test port of Vacuum Facility 6, as shown. A series of tests were performed between June and August of 2002 that resulted in a total PCU operational time of about 24 hr. An initial test sequence on June 17 determined that the reconfigured unit was fully operational. Ensuing tests provided the operational data needed to characterize PCU performance over its full operating range. The primary test variables used in operating the Brayton PCU were heater input power and rotor speed. Testing demonstrated a maximum steady-state alternating-current power output of 1835 W at a gas heater power of 9000 W and a rotor speed of 52000 rpm. The corresponding measured turbine inlet gas temperature was 1076 K, and the compressor inlet gas temperature was 282 K. When insulation losses from the gas heater were neglected, the Brayton cycle efficiency for the maximum power point was calculated to be 24 percent. The net direct-current power output was 1750 W, indicating a PMAD efficiency of about 95 percent.

Mason, Lee S.↗

TrustDER: Trusted, Private and Scalable Coordination of Distributed Energy Resources

In this project, the Stanford and SLAC Teams have developed a Trusted, Private and Scalable platform for coordinating Coordination of Distributed Energy Resources (TrustDER). This is a layered system that ensures private, trusted and scalable coordination and monitoring of DERs. It accommodates a variety of resources, such as solar generation, gensets and loads, with a particular focus on battery systems-based resources, as they are a transformational technology experiencing fast growth in adoption by large critical facilities. The platform can be used as standalone or added to existing aggregation systems to enable trust, privacy and resilience. TrustDER consists of layers that address each of the shortcomings of the existing state of the art. Each layer in the platform can operate independently but provides information to the layers above it to enable a novel form of overall coordination architecture. The project consists of several tasks, with each task dedicated to the design of each layer. Task 2 Resource Virtualization defined a software abstraction layer for distributed energy resources (DERs). The goal of this abstraction was to simplify the implementation of algorithms utilizing cooperation of DERs resources in a variety of use cases. Task 3 is on Secure ID for Asset Authentication. Identity Management Systems (IDMS) are a foundational infrastructure for interactions between entities (organizations, users, devices, and services). Secure ID is blockchain-based a distributed identity management system allowing (1) identity provisioning, (2) authentication, (3) authorization, and (4) identity data sharing for IoT-enabled assets on the electricity grid. In this project, the SLAC team focused on designing and testing Keymaker, a protocol for authenticating device identity managed by Secure ID. Task 5 Private and Safe Integration is focused on the design and evaluation of a DER cooperation scheme which allows for the aggregation of DERs without impacting network reliability. The approach is designed based on realistic assumptions regarding data availability, communication infrastructure limitations, and privacy. Task 6 Scalable Distributed Privacy for Information explored how virtualized batteries could be managed privately. Specifically, it examined the case in which a principal provides a partitioned battery to multiple clients. Task 7 Use Cases was to ensure that this technology was applied in relevant situations and scenarios. Primarily, this means that virtualization needed to be employed in a manner that either improved flexibility, bolstered security or privacy, or decreased costs.

25 ENERGY STORAGE↗

Ultra-Fast Resonant DC Breaker

This project’s focus was to create an ultra-fast resonant hybrid dc circuit breaker for medium voltage electric systems. Medium voltage DC systems offer higher efficiency, additional resiliency, more controllability, and greater flexibility over comparable AC systems. Although technically, medium voltage DC systems are more attractive than their AC counterparts, no solution exists for the protection of medium voltage DC systems, and thus one cannot build a reliable MVDC system. This research will fill the technology gap, providing a MVDC protection solution, allowing mass adoption and proliferation of MVDC systems. MVDC systems will allow greater integration of renewable energy sources, higher efficiency of transmission and distribution, reduced losses in transmission lines, reduce carbon emissions, and higher electric power reliability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Applying Utility's Advanced Grid Technologies to Improve Resiliency of a Critical Load

The US DOE Office of Electricity's Energy Storage Program's joint R&D work with the Cordova Electric Cooperative (CEC) has deployed several advanced grid technologies that are providing benefits today to Cordova Alaska's electricity users. Advanced grid technologies deployed through DoE co-funded R&D include a 1MW Battery Energy Storage System (BESS), and enhanced monitoring including Phasor Measurement Units (PMU's) to help better understand the operational impacts of the added BESS. This paper will highlight key accomplishments to-date in deploying and using advanced grid technologies, and then outline the next phase of work that will use these technologies to implement an operating scheme to reconfigure the utility's distribution system and utility resources including BESS to provide emergency back-up power to a critical load: the Cordova Community Medical Center (CCMC). This paper will include additional insights on the use of utility resources to support critical loads via case study examples by the National Rural Electric Cooperative Assoc. (NRECA).

BESS↗

Characterization of Soil Thermal and Electrical Properties along Multiple Hillslope Transects at Teller Road Site, Seward Peninsula, Alaska, 2017

This dataset has been acquired along five-119 m long transects located on the bottom part of the watershed hillslope at the NGEE Arctic Teller Road site at mile marker 27 (TL_MM27) on the Seward Peninsula, Alaska in July and September 2017. The Distributed Temperature Profiling (DTP) system dataset consist in vertically-resolved profile of soil temperature covering the top 0.8 m of soil with 8 cm interval. In addition to DPT data, electrical resistivity tomography (ERT) data, soil moisture, depth to rock or thaw layer thickness (no differentiation) and ground elevations data have been acquired along each of the transects. A UAV-based geotiff mosaic of the investigated site is also provided. The four data types provided with this dataset of 37 files (*.csv, *.tif, *.DATA): (1) soil temperature profiles, (2) ERT data, (3) the physical measurements of the thaw layer, and (4) an orthomosaic GeoTIFF of the transect study area.The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research.The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska.Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

An economic assessment of behind-the-meter photovoltaics paired with batteries on the Hawaiian Islands.

Due to natural variability and uncertainty, the ever-increasing penetration of solar generation in Hawaii presents challenges to power grid operators to maintain reliable system operation. Demand response (DR) has the potential to be a cost-effective tool for Hawaii to reach its aggressive renewable energy goals while maintaining the reliability of power grids. The Hawaii Public Utilities Commission has approved the Hawaiian Electric Company's revised portfolio of DR programs. The companies have released a grid services purchase agreement and subscribed an initial tranche of load into their DR programs. This paper presents innovative analytical methods and comprehensive economic assessment for distributed photovoltaics (PV) paired with battery energy storage systems (BESSs) for two new DR programs, including fast frequency response and capacity grid service. Optimal dispatch and sizing methods are proposed for the paired system considering different tariff schedules and PV compensation programs across five islands. It was found that while the best resource configuration and potential economic benefits vary with tariff structure, a BESS paired with PV can be optimally dispatched to generate multiple value streams simultaneously. Compensation from DR programs is an important value stream to help increase the cost-effectiveness of the integrated system.

Battery energy storage system↗

Atomic structural mechanism for ferroelectric-antiferroelectric transformation in perovskite NaNbO 3

Sodium niobate (NaNbO 3 or NN) is described as “the most complex perovskite system,” which exhibits transitions between, as well as coexistence of, several ferroelectrics (FE) and antiferroelectric (AFE) phases at different temperatures. Recently, solid solutions of NN with stabilized AFE phases(s) have gained attention for energy-related applications, such as high-density energy storage and electrocaloric cooling. A better understanding of the atomic mechanisms responsible for AFE/FE phase transitions in NaNbO 3 can enable a more rational design of its solid-solution systems with tunable functional properties. In this work, we have investigated changes in the average and local atomic structure of NN using a combination of x-ray/neutron diffraction and neutron pair-distribution function (PDF) analyses. The Rietveld refinement of the x-ray/neutron-diffraction patterns indicates a coexistence of the FE Q (P2 1 ma) and AFE P (Pbma) phases in the temperature range of 300 K ≤ T ≤ 615K, while PDF analysis indicated that the local structure (r < 8Å) is better described by a P2 1 ma symmetry. Above 615 K, the average structure transitions to an AFE R phase (Pmmn or Pnma), while PDF analysis shows an increased disordering of the octahedral distortions and Na displacements at the local scale. These results indicate that the average P/Q/R phase transitions in NN can be described as a result of complex ordering of distorted octahedral tilts at the nanoscale and off-centered displacements of the Na atoms.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A Power Conversion Concept for the Jupiter Icy Moons Orbiter

The Jupiter Icy Moons Orbiter (JIMO) mission is currently under study by the Office of Space Science under the Project Prometheus Program. JIMO is examining the use of Nuclear Electric Propulsion (NEP) to carry scientific payloads to three Jovian moons. A potential power system concept includes dual 100 kWe Brayton converters, a deployable pumped loop heat rejection subsystem, and a 400 Vac Power Management and Distribution (PMAD) bus. Many trades were performed in aniving at this candidate power system concept. System-level studies examined design and off-design operating modes, determined startup requirements, evaluated subsystem redundancy options, and quantified the mass and radiator area of reactor power systems from 20 to 200 kWe. In the Brayton converter subsystem, studies were performed to investigate converter packaging options, and assess the induced torque effects on spacecraft dynamics due to rotating machinery. In the heat rejection subsystem, design trades were conducted on heat transport approaches, material and fluid options, and deployed radiator geometries. In the PMAD subsystem, the overall electrical architecture was defined and trade studies examined distribution approaches, voltage levels, and cabling options.

Mason, Lee S.↗

Ampaire ARPA-e Electric Flight Testbed

A hybrid-electric aircraft flying testbed was developed in this program with the intent to serve as a dedicated, enduring testbed to test and evaluate ARPA-e CIRCUITS Program and other electrified aviation technologies in relevant flight environments. This testbed enabled rapid development cycles of novel and innovative technologies in the electrified aviation space, maturing them from a research lab environment to flying in an aircraft. By providing research groups with the means to test their transformative technologies in a real-world, aircraft environment, the path to validating the safety and reliability of their technologies for future commercial opportunities was greatly accelerated. Three core technologies were integrated and tested: an inverter/motor drive built by the University of Arkansas, a solid-state circuit breaker (iBreaker) built by the Illinois Institute of Technology, and a Flying Capacitor Multi-level (FCML) DC/DC converter built by the University of California, Berkeley. In each of these cases, the requirements established for safety of flight resulted in a holistic approach to the designs, evoking a deeper understanding of the potential failure modes and mitigations necessary to build a robust and flightworthy system. Further, the integration into a hybrid-electric aircraft de-risked the potential electrical and mechanical issues that cannot easily be experienced or replicated in a lab environment. The experiments were also required to undergo representative temperature, shock, and vibration testing as the FAA prescribes for this category of aircraft, facilitating familiarity with the relevant design and test guidelines necessary to commercialize the technologies. This testbed unlocks the massive potential of core power electronics technologies necessary for a safe, robust, and efficient electric aviation future. With quick iterative design, test, and flight cycles, these core technologies are on a quicker path to technology readiness level maturity and commercialization, enabling a more sustainable future for the aviation industry.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Fragility Functions Resource Report: Documented Sources for Electricity and Water Resilience Valuation

Fragility curves provide the vulnerability between hazard intensity and an asset. Federal installations may include many different electricity and water infrastructure types (or assets) such as generators, wind turbines, solar PV, switch yards, substations and power lines as well as water distribution systems that could be affected by different hazards. The vulnerability of each asset is a function of its age, type of materials and maintenance. In addition, the vulnerability changes with the hazards intensity and has a probability distribution function associated with it. The fragility functions are used in conjunction with hazard probability and consequence valuations to determine the values at risk for examination of investment grade analyses of alternative mitigation strategies. This document provides examples of fragility functions and links to their sources for different electricity and water infrastructure assets by hazard type.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Wind Tunnel-Based Aerodynamic Model Identification for a Tilt-Wing, Distributed Electric Propulsion Aircraft

This paper describes the methodology used to develop a high-fidelity aerodynamic model for the Langley Aerodrome No. 8 (LA-8) tandem tilt-wing, distributed electric propulsion, vertical takeoff and landing aircraft. Electric vertical takeoff and landing (eVTOL) vehicle configurations exhibit aerodynamic characteristics of both fixed-wing and rotary-wing aircraft as well as complex vehicle-specific phenomena, such as propeller-wing interactions and high incidence angle propeller aerodynamics. Consequently, conventional aircraft aerodynamic modeling strategies require modification when applied to eVTOL aircraft. Two novel system identification-based approaches are used to develop an aerodynamic model for the LA-8 aircraft configuration using wind tunnel data collected with design of experiments techniques. The modeling strategies are compared by assessing their predictive performance for validation data acquired separately from the data used to identify the model and are shown to have sufficient predictive capability. Research findings are presented with a discussion of unique eVTOL aerodynamic modeling characteristics and practical strategies to inform future aerodynamic modeling efforts for eVTOL aircraft.

Urban Air Mobility↗

The application of simulation modeling to the cost and performance ranking of solar thermal power plants

A computer simulation code was employed to evaluate several generic types of solar power systems (up to 10 MWe). Details of the simulation methodology, and the solar plant concepts are given along with cost and performance results. The Solar Energy Simulation computer code (SESII) was used, which optimizes the size of the collector field and energy storage subsystem for given engine-generator and energy-transport characteristics. Nine plant types were examined which employed combinations of different technology options, such as: distributed or central receivers with one- or two-axis tracking or no tracking; point- or line-focusing concentrator; central or distributed power conversion; Rankin, Brayton, or Stirling thermodynamic cycles; and thermal or electrical storage. Optimal cost curves were plotted as a function of levelized busbar energy cost and annualized plant capacity. Point-focusing distributed receiver systems were found to be most efficient (17-26 percent).

Rosenberg, L. S.↗

Electric Vehicles Charging Time Constrained Deliverable Provision of Secondary Frequency Regulation

Aggregation of electric vehicles (EVs) is a promising technique for providing secondary frequency regulation (SFR) in highly renewable energy-penetrated power systems. Equipped with energy storage devices, EV aggregation can provide reliable SFR. However, the main challenge is to guarantee reliable intra-interval SFR capacities and inter-interval delivery following the automatic generation control (AGC) signal. Furthermore, aggregated EV SFR provision will be further complicated by the EV charging time anxiety because SFR provision might extend EV's charging time. This paper proposes a deliverable EV SFR provision with a charging-time-constrained control strategy. First, a charging-time-constrained EV aggregation is proposed to address the uncertainty of EV capacity based on the state-space model considering the charging-time restriction of EV owners. Second, a real-time economic dispatch and time domain simulation (RTED-TDS) cosimulation framework is proposed to verify financial results and the dynamic performance of the EV SFR provision. Last, the proposed charging time-constrained EV aggregation is validated on the IEEE 39-bus system. In conclusion, the results demonstrate that with charging time-constrained EV aggregation, the dynamic performance of the system can be improved with a marginal increase in total cost. More importantly, the charging time constraint can be respected in the proposed SFR provision of the EV aggregation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Assessment and Commissioning of Electrical Substation Grid Testbed with a Real-Time Simulator and Protective Relays/Power Meters in the Loop

Electrical utility substations are wired with intelligent electronic devices (IEDs), such as protective relays, power meters, and communication switches. Substation engineers commission these IEDs to assess the appropriate measurements for monitoring, control, power system protection, and communication applications. Like real electrical utility substations, complex electrical substation grid testbeds (ESGTs) need to be assessed for measuring current and voltage signals in monitoring, power system protection, control (synchro check), and communication applications that are limited by small measurement percentage errors. In the process of setting an ESGT with real-time simulators and IEDs in the loop, protective relays, power meters, and communication devices must be commissioned before running experiments. In this study, an ESGT with IEDs and distributed ledger technology was developed. The ESGT with a real-time simulator and IEDs in the loop was satisfactorily assessed and commissioned. The commissioning and problem-solving tasks of the testbed are described to define a method with flowcharts to assess possible trouble-shooting in ESGTs. This method was based on comparing the simulations versus IED measurements for the phase current and voltage magnitudes, three-phase phasor diagrams, breaker states, protective relay times with selectivity coordination at electrical faults, communication data points, and time-stamp sources.

Piesciorovsky, Emilio↗