Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “eclipse”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

WE-F-16A-05: Use of 3D-Printers to Create a Tissue Equivalent 3D-Bolus for External Beam Therapy

Purpose: The purpose of this project is to demonstrate that a non-expensive 3D-printer can be used to manufacture a 3D-bolus for external beam therapy. The printed bolus then can be modeled in our treatment planning system to ensure accurate dose delivery to the patient. Methods: We developed a simple method to manufacture a patient-specific custom 3Dbolus. The bolus is designed using Eclipse Treatment Planning System, contoured onto the patients CT images. The bolus file is exported from Eclipse to 3D-printer software, and then printed using a 3D printer. Various tests were completed to determine the properties of the printing material. Percent depth dose curves in this material were measured with electron and photon beams for comparison to other materials. In order to test the validity of the 3D printed bolus for treatment planning, a custom bolus was printed and tested on the Rando phantom using film for a dose plane comparison. We compared the dose plane measured on the film to the same dose plane exported from our treatment planning system using Film QA software. The gamma-dose distribution tool was used in our film analysis. Results: We compared point measurements throughout the dose plane and were able to achieve greater than 95% passing rate at 3% dose difference and 3 mm distance to agreement, which is our departments acceptable gamma pixel parameters. Conclusion: The printed 3D bolus has proven to be accurately modeled in our treatment planning system, it is more conformal to the patient surface and more durable than other bolus currently used (wax, superflab etc.). It is also more convenient and less costly than comparable bolus from milling machine companies.

60 APPLIED LIFE SCIENCES↗

Poster — Thur Eve — 61: A new framework for MPERT plan optimization using MC-DAO

This work combines the inverse planning technique known as Direct Aperture Optimization (DAO) with Intensity Modulated Radiation Therapy (IMRT) and combined electron and photon therapy plans. In particular, determining conditions under which Modulated Photon/Electron Radiation Therapy (MPERT) produces better dose conformality and sparing of organs at risk than traditional IMRT plans is central to the project. Presented here are the materials and methods used to generate and manipulate the DAO procedure. Included is the introduction of a powerful Java-based toolkit, the Aperture-based Monte Carlo (MC) MPERT Optimizer (AMMO), that serves as a framework for optimization and provides streamlined access to underlying particle transport packages. Comparison of the toolkit's dose calculations to those produced by the Eclipse TPS and the demonstration of a preliminary optimization are presented as first benchmarks. Excellent agreement is illustrated between the Eclipse TPS and AMMO for a 6MV photon field. The results of a simple optimization shows the functioning of the optimization framework, while significant research remains to characterize appropriate constraints.

60 APPLIED LIFE SCIENCES↗

Independent calculation of monitor units for VMAT and SPORT

Purpose: Dose and monitor units (MUs) represent two important facets of a radiation therapy treatment. In current practice, verification of a treatment plan is commonly done in dose domain, in which a phantom measurement or forward dose calculation is performed to examine the dosimetric accuracy and the MU settings of a given treatment plan. While it is desirable to verify directly the MU settings, a computational framework for obtaining the MU values from a known dose distribution has yet to be developed. This work presents a strategy to calculate independently the MUs from a given dose distribution of volumetric modulated arc therapy (VMAT) and station parameter optimized radiation therapy (SPORT). Methods: The dose at a point can be expressed as a sum of contributions from all the station points (or control points). This relationship forms the basis of the proposed MU verification technique. To proceed, the authors first obtain the matrix elements which characterize the dosimetric contribution of the involved station points by computing the doses at a series of voxels, typically on the prescription surface of the VMAT/SPORT treatment plan, with unit MU setting for all the station points. An in-house Monte Carlo (MC) software is used for the dose matrix calculation. The MUs of the station points are then derived by minimizing the least-squares difference between doses computed by the treatment planning system (TPS) and that of the MC for the selected set of voxels on the prescription surface. The technique is applied to 16 clinical cases with a variety of energies, disease sites, and TPS dose calculation algorithms. Results: For all plans except the lung cases with large tissue density inhomogeneity, the independently computed MUs agree with that of TPS to within 2.7% for all the station points. In the dose domain, no significant difference between the MC and Eclipse Anisotropic Analytical Algorithm (AAA) dose distribution is found in terms of isodose contours, dose profiles, gamma index, and dose volume histogram (DVH) for these cases. For the lung cases, the MC-calculated MUs differ significantly from that of the treatment plan computed using AAA. However, the discrepancies are reduced to within 3% when the TPS dose calculation algorithm is switched to a transport equation-based technique (Acuros™). Comparison in the dose domain between the MC and Eclipse AAA/Acuros calculation yields conclusion consistent with the MU calculation. Conclusions: A computational framework relating the MU and dose domains has been established. The framework does not only enable them to verify the MU values of the involved station points of a VMAT plan directly in the MU domain but also provide a much needed mechanism to adaptively modify the MU values of the station points in accordance to a specific change in the dose domain.

60 APPLIED LIFE SCIENCES↗

SU-E-T-96: An Analysis of VMAT SBRT Lung Treatment Plans

Purpose: To present an analysis of 218 lung sbrt treatment plans delivered using Varian Eclipse RapidArc software and delivered with Varian linear accelerators. Methods: A retrospective analysis of treatment plans generated using the Varian Eclipse PRO RapidArc VMAT optimization and AAA photon beam calculation algorithms was done for 218 plans delivered using Varian Trilogy and TrueBeam linear accelerators. Some of the patients were enrolled in the RTOG 0813 and RTOG 0915 lung protocols. All of the patients’ plans were optimized using the guidelines outlined by these protocols. The plans presented were normalized so that 95% of the PTV volume received 100% of the prescribed dose. Results: The dose co formality constraints from the RTOG protocols and the number of plans within those constraints were:Tumor dose between 60% of maximum dose and 90% of maximum: 218/218 = 100%.Volume of 105% tumor dose outside put less than 15% of the PTV volume: 218/218 = 100%.Maximum dose 2 cm away from PTV within protocol table guidelines: No minor deviation: 188/218 = 86.2%. No major deviation: 216/218 = 99.1%.Ratio of 50% dose volume to PTV volume less than R50 in protocol table: No minor deviation 148/218 = 67.9%. No major deviation: 213/218 = 97.7%.Percent of lung receiving 20 Gy less than 10% (no minor violation): 218/218 = 100%.99% of PTV receiving at least 90% of the tumor dose: 214/218 = 98.2%. Conclusion: Varian RapidArc VMAT can successfully deliver lung SBRT treatments as outlined in the RTOG 0813 and 0915 protocols. The largest deviations were seen in the R50 constraints for the larger PTV volumes.

60 APPLIED LIFE SCIENCES↗

SU-E-T-231: Cross-Validation of 3D Gamma Comparison Tools

Purpose: Moving the computational analysis for 3D gel dosimetry into the 3D Slicer (www.slicer.org) environment has made gel dosimetry more clinically accessible. To ensure accuracy, we cross-validate the 3D gamma comparison module in 3D Slicer with an independently developed algorithm using simulated and measured dose distributions. Methods: Two reference dose distributions were generated using the Varian Eclipse treatment planning system. The first distribution consisted of a four-field box irradiation delivered to a plastic water phantom and the second, a VMAT plan delivered to a gel dosimeter phantom. The first reference distribution was modified within Eclipse to create an evaluated dose distribution by spatially shifting one field by 3mm, increasing the monitor units of the second field, applying a dynamic wedge for the third field, and leaving the fourth field unchanged. The VMAT plan was delivered to a gel dosimeter and the evaluated dose in the gel was calculated from optical CT measurements. Results from the gamma comparison tool built into the SlicerRT toolbox were compared to results from our in-house gamma algorithm implemented in Matlab (via MatlabBridge in 3D Slicer). The effects of noise, resolution and the exchange of reference and evaluated designations on the gamma comparison were also examined. Results: Perfect agreement was found between the gamma results obtained using the SlicerRT tool and our Matlab implementation for both the four-field box and gel datasets. The behaviour of the SlicerRT comparison with respect to changes in noise, resolution and the role of the reference and evaluated dose distributions was consistent with previous findings. Conclusion: Two independently developed gamma comparison tools have been cross-validated and found to be identical. As we transition our gel dosimetry analysis from Matlab to 3D Slicer, this validation serves as an important test towards ensuring the consistency of dose comparisons using the 3D Slicer environment.

60 APPLIED LIFE SCIENCES↗

SU-E-T-317: Dosimetric Evaluation of Acuros XB Advanced Dose Calculation Algorithm in Head and Neck Patients

Purpose: The Acuros XB photon dose calculation algorithm is a newly implemented calculation technique within the Eclipse treatment planning system using deterministic solutions to the linear Boltzmann transport equations. The goal of this study is to assess the clinical impact of dose differences arising from a retrospective comparison of calculations performed using the Analytical Anisotropic Algorithm (AAA) and Acuros XB on patients. Methods: Ten head and neck patients receiving intensity modulated radiation therapy were selected as a pilot study. Initial evaluation was based on the percentage of the planning target volume (PTV) covered by the prescription dose, minimum dose within the PTV, and dose differences in critical structures. For patients receiving boost plans, dosimetric evaluations were performed on the plan sum of the primary and boost plans. Results: Among the ten patients there were a total of 21 PTVs corresponding to primary and boost volumes. Using the same normalization within Eclipse, the average percentage of the PTVs receiving the prescription dose were 95.6% for AAA and Acuros XB. The average minimum doses within the PTVs, expressed as a percentage of the prescription to the volume, were 82.3% and 83.6% for AAA and Acuros XB respectively. Neither comparison showed differences with statistical significance when subjected to a paired t-test. Statistical significance was found in the average difference of the maximum dose for the mandible (242.5cGy, p=0.0005) and cord with a 5mm radial expansion (105.0cGy, p=0.0005) and in the median dose for the left parotid (25.0cGy, p=0.0423) and oral cavity (36.3cGy, p=0.002). Conclusion: The Acuros XB dose calculation algorithm did not exhibit significant differences in PTV coverage when compared to the AAA algorithm. Significant differences in critical structures are likely attributed to the structures proximity to high atomic number materials or air cavities, regions of known difficulty for the AAA algorithm.

60 APPLIED LIFE SCIENCES↗

SU-E-T-381: Evaluation of Calculated Dose Accuracy for Organs-At-Risk Located at Out-Of-Field in a Commercial Treatment Planning System for High Energy Photon Beams Produced From TrueBeam Accelerators

Purpose: Dose calculation accuracy for the out-of-field dose is important for predicting the dose to the organs-at-risk when they are located outside primary beams. The investigations on evaluating the calculation accuracy of treatment planning systems (TPS) on out-of-field dose in existing publications have focused on low energy (6MV) photon. This study evaluates out-of-field dose calculation accuracy of AAA algorithm for 15MV high energy photon beams. Methods: We used the EGSnrc Monte Carlo (MC) codes to evaluate the AAA algorithm in Varian Eclipse TPS (v.11). The incident beams start with validated Varian phase-space sources for a TrueBeam linac equipped with Millennium 120 MLC. Dose comparisons between using AAA and MC for CT based realistic patient treatment plans using VMAT techniques for prostate and lung were performed and uncertainties of organ dose predicted by AAA at out-of-field location were evaluated. Results: The results show that AAA calculations under-estimate doses at the dose level of 1% (or less) of prescribed dose for CT based patient treatment plans using VMAT techniques. In regions where dose is only 1% of prescribed dose, although AAA under-estimates the out-of-field dose by 30% relative to the local dose, it is only about 0.3% of prescribed dose. For example, the uncertainties of calculated organ dose to liver or kidney that is located out-of-field is <0.3% of prescribed dose. Conclusion: For 15MV high energy photon beams, very good agreements (<1%) in calculating dose distributions were obtained between AAA and MC. The uncertainty of out-of-field dose calculations predicted by the AAA algorithm for realistic patient VMAT plans is <0.3% of prescribed dose in regions where the dose relative to the prescribed dose is <1%, although the uncertainties can be much larger relative to local doses. For organs-at-risk located at out-of-field, the error of dose predicted by Eclipse using AAA is negligible. This work was conducted in part using the resources of Varian research grant VUMC40590-R.

60 APPLIED LIFE SCIENCES↗

SU-E-T-479: IMRT Plan Recalculation in Patient Based On Dynalog Data and the Effect of a Single Failing MLC Motor

Purpose: Using Linac dynamic logs (Dynalogs) we evaluate the impact of a single failing MLC motor on the deliverability of an IMRT plan by assessing the recalculated dose volume histograms (DVHs) taking the delivered MLC positions and beam hold-offs into consideration. Methods: This is a retrospective study based on a deteriorating MLC motor (leaf 36B) which was observed to be failing via Dynalog analysis. To investigate further, Eclipse-importable MLC files were generated from Dynalogs to recalculate the actual delivered dose and to assess the clinical impact through DVHs. All deliveries were performed on a Varian 21EX linear accelerator equipped with Millennium-120 MLC. The analysis of Dynalog files and subsequent conversion to Eclipse-importable MLC files were all performed by in-house programming in Python. Effects on plan DVH are presented in the following section on a particular brain-IMRT plan which was delivered with a failing MLC motor which was then replaced. Results: Global max dose increased by 13.5%, max dose to the brainstem PRV increased by 8.2%, max dose to the optic chiasm increased by 7.6%, max dose to optic nerve increased by 8.8% and the mean dose to the PTV increased by 7.9% when comparing the original plan to the fraction with the failing MLC motor. The reason the dose increased was due to the failure being on the B-bank which is the lagging side on a sliding window delivery, therefore any failures on this side will cause an over-irradiation as the B-bank leaves struggles to keep the window from growing. Conclusion: Our findings suggest that a single failing MLC motor may jeopardize the entire delivery. This may be due to the bad MLC motor drawing too much current causing all MLCs on the same bank to underperform. This hypothesis will be investigated in a future study.

60 APPLIED LIFE SCIENCES↗

SU-E-T-647: Quality Assurance of VMAT by Gamma Analysis Dependence On Low-Dose Threshold

Purpose: The AAPM TG-119 instructed institutions to use low-dose threshold (LDT) of 10% or a ROI determined by the jaw when they collected gamma analysis QA data of planar dose distribution. Also, based on a survey by Nelms and Simon, more than 70% of institutions use a LDT between 0% and 10% for gamma analysis. However, there are no clinical data to quantitatively demonstrate the impact of the LDT on the gamma index. Therefore, we performed a gamma analysis with LDTs of 0% to 15% according to both global and local normalization and different acceptance criteria: 3%/3 mm, 2%/2 mm, and 1%/1 mm. Methods: A total of 30 treatment plans—10 head and neck, 10 brain, and 10 prostate cancer cases—were randomly selected from the Varian Eclipse TPS, retrospectively. For the gamma analysis, a predicted portal image was acquired through a portal dose calculation algorithm in the Eclipse TPS, and a measured portal image was obtained using a Varian Clinac iX and an EPID. Then, the gamma analysis was performed using the Portal Dosimetry software. Results: For the global normalization, the gamma passing rate (%GP) decreased as the LDT increased, and all cases of low-dose thresholds exhibited a %GP above 95% for both the 3%/3 mm and 2%/2 mm criteria. However, for local normalization, the %GP increased as LDT increased. The gamma passing rate with LDT of 10% increased by 6.86%, 9.22% and 6.14% compared with the 0% in the case of the head and neck, brain and prostate for 3%/3 mm criteria, respectively. Conclusion: Applying the LDT in the global normalization does not have critical impact to judge patient-specific QA results. However, LDT for the local normalization should be carefully selected because applying the LDT could affect the average of the %GP to increase rapidly.

61 RADIATION PROTECTION AND DOSIMETRY↗

Monte Carlo validation of the TrueBeam 10XFFF phase–space files for applications in lung SABR

Purpose: To establish the clinical acceptability of universal Monte Carlo phase–space data for the 10XFFF (flattening filter free) photon beam on the Varian TrueBeam Linac, including previously unreported data for small fields, output factors, and inhomogeneous media. The study was particularly aimed at confirming the suitability for use in simulations of lung stereotactic ablative radiotherapy treatment plans. Methods: Monte Carlo calculated percent depth doses (PDDs), transverse profiles, and output factors for the TrueBeam 10 MV FFF beam using generic phase–space data that have been released by the Varian MC research team were compared with in-house measurements and published data from multiple institutions (ten Linacs from eight different institutions). BEAMnrc was used to create field size specific phase–spaces located underneath the jaws. Doses were calculated with DOSXYZnrc in a water phantom for fields ranging from 1 × 1 to 40 × 40 cm{sup 2}. Particular attention was paid to small fields (down to 1 × 1 cm{sup 2}) and dose per pulse effects on dosimeter response for high dose rate 10XFFF beams. Ion chamber measurements were corrected for changes in ion collection efficiency (P{sub ion}) with increasing dose per pulse. MC and ECLIPSE ANISOTROPIC ANALYTICAL ALGORITHM (AAA) calculated PDDs were compared to Gafchromic film measurement in inhomogeneous media (water, bone, lung). Results: Measured data from all machines agreed with Monte Carlo simulations within 1.0% and 1.5% for PDDs and in-field transverse profiles, respectively, for field sizes >1 × 1 cm{sup 2} in a homogeneous water phantom. Agreements in the 80%–20% penumbra widths were better than 2 mm for all the fields that were compared. For all the field sizes considered, the agreement between their measured and calculated output factors was within 1.1%. Monte Carlo results for dose to water at water/bone, bone/lung, and lung/water interfaces as well as within lung agree with film measurements to within 2.8% for 10 × 10 and 3 × 3 cm{sup 2} field sizes. This represents a significant improvement over the performance of the ECLIPSE AAA. Conclusions: The 10XFFF phase–space data offered by the Varian Monte Carlo research team have been validated for clinical use using measured, interinstitutional beam data in water and with film dosimetry in inhomogeneous media.

60 APPLIED LIFE SCIENCES↗

SU-C-202-05: Pilot Study of Online Treatment Evaluation and Adaptive Re-Planning for Laryngeal SBRT

Purpose: We have instigated a phase I trial of 5-fraction stereotactic body radiotherapy (SBRT) for advanced-stage laryngeal cancer. We conducted this pilot dosimetric study to confirm the potential utility of online adaptive re-planning to preserve treatment quality. Methods: Ten cases of larynx cancer were evaluated. Baseline and daily SBRT treatment plans were generated per trial protocol. Daily volumetric images were acquired prior to every fraction of treatment. Reference simulation CT images were deformably registered to daily volumetric images using Eclipse. Planning contours were then deformably propagated to daily images. Reference SBRT plans were directly copied to calculate delivered dose distributions on deformed reference CT images. In-house software platform has been developed to calculate cumulative dose over a course of treatment in four steps: 1) deforming delivered dose grid to reference CT images using deformation information exported from Eclipse; 2) generating tetrahedrons using deformed dose grid as vertices; 3) resampling dose to a high resolution within every tetrahedron; 4) calculating dose-volume histograms. Our inhouse software was benchmarked with a commercial software, Mirada. Results: In all ten cases including 49 fractions of treatments, delivered daily doses were completely evaluated and treatment could be re-planned within 10 minutes. Prescription dose coverage of PTV was less than intended in 53% of fractions of treatment (mean: 94%, range: 84%–98%) while minimum coverage of CTV and GTV was 94% and 97%, respectively. Maximum bystander point dose limits to arytenoids, parotids, and spinal cord remained respected in all cases, although variances in carotid artery doses were observed in a minority of cases. Conclusion: Although GTV and CTV coverage is preserved by in-room 3D image guidance of larynx SBRT, PTV coverage can vary significantly from intended plans. Online adaptive treatment evaluation and re-planning is potentially necessary and our procedure is clinically applicable to fully preserve treatment quality. This project is supported by CPRIT Individual Investigator Research Award RP150386.

60 APPLIED LIFE SCIENCES↗

SU-F-P-07: Applying Failure Modes and Effects Analysis to Treatment Planning System QA

Purpose: A small-scale implementation of Failure Modes and Effects Analysis (FMEA) for treatment planning system QA by utilizing methodology of AAPM TG-100 report. Methods: FMEA requires numerical values for severity (S), occurrence (O) and detectability (D) of each mode of failure. The product of these three values gives a risk priority number (RPN). We have implemented FMEA for the treatment planning system (TPS) QA for two clinics which use Pinnacle and Eclipse TPS. Quantitative monthly QA data dating back to 4 years for Pinnacle and 1 year for Eclipse have been used to determine values for severity (deviations from predetermined doses at points or volumes), and occurrence of such deviations. The TPS QA protocol includes a phantom containing solid water and lung- and bone-equivalent heterogeneities. Photon and electron plans have been evaluated in both systems. The dose values at multiple distinct points of interest (POI) within the solid water, lung, and bone-equivalent slabs, as well as mean doses to several volumes of interest (VOI), have been re-calculated monthly using the available algorithms. Results: The computed doses vary slightly month-over-month. There have been more significant deviations following software upgrades, especially if the upgrade involved re-modeling of the beams. TG-100 guidance and the data presented here suggest an occurrence (O) of 2 depending on the frequency of re-commissioning the beams, severity (S) of 3, and detectability (D) of 2, giving an RPN of 12. Conclusion: Computerized treatment planning systems could pose a risk due to dosimetric errors and suboptimal treatment plans. The FMEA analysis presented here suggests that TPS QA should immediately follow software upgrades, but does not need to be performed every month.

60 APPLIED LIFE SCIENCES↗

SU-F-T-27: A Comparative Case Study Among Four Modalities for the Superficial Treatment of Squamous Cell Carcinoma

Purpose: We performed a comparative planning study among High Dose Rate (HDR) brachytherapy, superficial electrons, Volume Modulated Arc Therapy (VMAT), and Helical IMRT (Tomotherapy) for squamous cell carcinoma of the abdominal wall with consideration for the underlining bowel. Methods: A 69-year old female presented with squamous cell carcinoma protruding 8mm beyond the anterior skin surface of the midabdomen was considered for treatment. The patient had a ventral hernia which resulted in the reduction of the abdominal wall thickness and the adjacent small bowel being the dose limiting structure. Four plans were generated using different treatment modalities: a) an enface electron field (eMC, Eclipse v. 11), b) Tomotherapy (HI-Art II v.5.0.5), c) VMAT (Acuros, Eclipse v. 11), and d) HDR using a Freiburg applicator (Oncentra v. 4.3). The following plan objectives were used for all four plans: for the CTV target, V90% ≥90% (61.8Gy2/2).For the small bowel, D0.1cc < 56.2 Gy2/2 was a hard constraint and expressed as a percentage of the prescription for comparison to demonstrate the dose fall-off achieved among the modalities.For HDR, V200% <0.1cc was an additional constraint. Multiple dosimetric parameters, including those listed above, were compared among the four modalities. Results: The HDR plan showed comparable target coverage compared to the Tomotherapy plan and better coverage compared to the electron plan. Small bowel doses (D0.1cc) were lower in HDR plan compared to Tomotherapy, electron, & VMAT plans (88.8%, 89.6%, 90.9%, & 96.6%). Integral dose to the whole body (V5%) was much higher for HDR, VMAT, and Tomotherapy when compared to electron plan by factors of seven, eight, and ten, respectively. After reviewing all treatment modalities, the physician selected HDR owing to better control of the small bowel dose while maintaining adequate target coverage. Conclusion: This case study demonstrated HDR can successfully treat superficial lesions with superior sparing of underlying structures.

60 APPLIED LIFE SCIENCES↗

SU-F-T-156: Monte Carlo Simulation Using TOPAS for Synchrotron Based Proton Discrete Spot Scanning System

Purpose: This study provides an overview of the design and commissioning of the Monte Carlo (MC) model of the spot-scanning proton therapy nozzle and its implementation for the patient plan simulation. Methods: The Hitachi PROBEAT V scanning nozzle was simulated based on vendor specifications using the TOPAS extension of Geant4 code. FLUKA MC simulation was also utilized to provide supporting data for the main simulation. Validation of the MC model was performed using vendor provided data and measurements collected during acceptance/commissioning of the proton therapy machine. Actual patient plans using CT based treatment geometry were simulated and compared to the dose distributions produced by the treatment planning system (Varian Eclipse 13.6), and patient quality assurance measurements. In-house MATLAB scripts are used for converting DICOM data into TOPAS input files. Results: Comparison analysis of integrated depth doses (IDDs), therapeutic ranges (R90), and spot shape/sizes at different distances from the isocenter, indicate good agreement between MC and measurements. R90 agreement is within 0.15 mm across all energy tunes. IDDs and spot shapes/sizes differences are within statistical error of simulation (less than 1.5%). The MC simulated data, validated with physical measurements, were used for the commissioning of the treatment planning system. Patient geometry simulations were conducted based on the Eclipse produced DICOM plans. Conclusion: The treatment nozzle and standard option beam model were implemented in the TOPAS framework to simulate a highly conformal discrete spot-scanning proton beam system.

60 APPLIED LIFE SCIENCES↗

SU-F-T-284: The Effect of Linear Accelerator Output Variation On the Quality of Patient Specific Rapid Arc Verification Plans

Purpose: The aim of the current study is to investigate the effect of machine output variation on the delivery of the RapidArc verification plans. Methods: Three verification plans were generated using Eclipse™ treatment planning system (V11.031) with plan normalization value 100.0%. These plans were delivered on the linear accelerators using ArcCHECK− device, with machine output 1.000 cGy/MU at calibration point. These planned and delivered dose distributions were used as reference plans. Additional plans were created in Eclipse− with normalization values ranging 92.80%–102% to mimic the machine output ranging 1.072cGy/MU-0.980cGy/MU, at the calibration point. These plans were compared against the reference plans using gamma indices (3%, 3mm) and (2%, 2mm). Calculated gammas were studied for its dependence on machine output. Plans were considered passed if 90% of the points satisfy the defined gamma criteria. Results: The gamma index (3%, 3mm) was insensitive to output fluctuation within the output tolerance level (2% of calibration), and showed failures, when the machine output exceeds ≥3%. Gamma (2%, 2mm) was found to be more sensitive to the output variation compared to the gamma (3%, 3mm), and showed failures, when output exceeds ≥1.7%. The variation of the gamma indices with output variability also showed dependence upon the plan parameters (e.g. MLC movement and gantry rotation). The variation of the percentage points passing gamma criteria with output variation followed a non-linear decrease beyond the output tolerance level. Conclusion: Data from the limited plans and output conditions showed that gamma (2%, 2mm) is more sensitive to the output fluctuations compared to Gamma (3%,3mm). Work under progress, including detail data from a large number of plans and a wide range of output conditions, may be able to conclude the quantitative dependence of gammas on machine output, and hence the effect on the quality of delivered rapid arc plans.

60 APPLIED LIFE SCIENCES↗

SU-F-T-300: Impact of Electron Density Modeling of ArcCHECK Cylindricaldiode Array On 3DVH Patient Specific QA Software Tool Analysis

Purpose: 3DVH software is a patient specific quality assurance tool which estimates the 3D dose to the patient specific geometry with the help of Planned Dose Perturbation algorithm. The purpose of this study is to evaluate the impact of HU value of ArcCHECK phantom entered in Eclipse TPS on 3D dose & DVH QA analysis. Methods: Manufacturer of ArcCHECK phantom provides CT data set of phantom & recommends considering it as a homogeneous phantom with electron density (1.19 gm/cc or 282 HU) close to PMMA. We performed this study on Eclipse TPS (V13, VMS) & trueBEAM STx VMS Linac & ArcCHECK phantom (SNC). Plans were generated for 6MV photon beam, 20cm×20cm field size at isocentre & SPD (Source to phantom distance) of 86.7 cm to deliver 100cGy at isocentre. 3DVH software requires patients DICOM data generated by TPS & plan delivered on ArcCHECK phantom. Plans were generated in TPS by assigning different HU values to phantom. We analyzed gamma index & the dose profile for all plans along vertical down direction of beam’s central axis for Entry, Exit & Isocentre dose. Results: The global gamma passing rate (2% & 2mm) for manufacturer recommended HU value 282 was 96.3%. Detector entry, Isocentre & detector exit Doses were 1.9048 (1.9270), 1.00(1.0199) & 0.5078(0.527) Gy for TPS (Measured) respectively.The global gamma passing rate for electron density 1.1302 gm/cc was 98.6%. Detector entry, Isocentre & detector exit Doses were 1.8714 (1.8873), 1.00(0.9988) & 0.5211(0.516) Gy for TPS (Measured) respectively. Conclusion: Electron density value assigned by manufacturer does not hold true for every user. Proper modeling of electron density of ArcCHECK in TPS is essential to avoid systematic error in dose calculation of patient specific QA.

60 APPLIED LIFE SCIENCES↗

SU-F-T-449: Dosimetric Comparison of Acuros XB, Adaptive Convolve in Intensity Modulated Radiotherapy for Head and Neck Cancer

Purpose: There have been several publications focusing on dose calculation in lung for a new dose calculation algorithm of Acuros XB (AXB). AXB could contribute to dose calculation for high-density media for bone and dental prosthesis rather than in lung. We compared the dosimetric performance of AXB, Adaptive Convolve (AC) in head and neck IMRT plans. Methods: In a phantom study, the difference in depth profile between AXB and AC was evaluated using Kodak EDR2 film sandwiched with tough water phantoms. 6 MV x-ray using the TrueBeam was irradiated. In a patient study, 20 head and neck IMRT plans had been clinically approved in Pinnacle3 and were transferred to Eclipse. Dose distribution was recalculated using AXB in Eclipse while maintaining AC-calculated monitor units and MLC sequence planned in Pinnacle. Subsequently, both the dose-volumetric data obtained using the two different calculation algorithms were compared. Results: The results in the phantom evaluation for the shallow area ahead of the build-up region shows over-dose for AXB and under-dose for AC, respectively. In the patient plans, AXB shows more hot spots especially around the high-density media than AC in terms of PTV (Max difference: 4.0%) and OAR (Max. difference: 1.9%). Compared to AC, there were larger dose deviations in steep dose gradient region and higher skin-dose. Conclusion: In head and neck IMRT plans, AXB and AC show different dosimetric performance for the regions inside the target volume around high-density media, steep dose gradient regions and skin-surface. There are limitations in skin-dose and complex anatomic condition using even inhomogeneous anthropomorphic phantom Thus, there is the potential for an increase of hot-spot in AXB, and an underestimation of dose in substance boundaries and skin regions in AC.

60 APPLIED LIFE SCIENCES↗

SU-F-T-563: Delivered Dose Reconstruction of Moving Targets for Gated Volumetric Modulated Arc Therapy (VMAT)

Purpose: Actual delivered dose of moving tumors treated with gated volumetric arc therapy (VMAT) may significantly differ from the planned dose assuming static target. In this study, we developed a method which reconstructs actual delivered dose distribution of moving target by taking into account both tumor motion and dynamic beam delivery of gated VMAT, and applied to abdominal tumors. Methods: Fifteen dual-arc VMAT plans (Eclipse, Varian Medical Systems) for 5 lung, 5 pancreatic, and 5 liver cancer patients treated with gated VMAT stereotactic body radiotherapy (SBRT) were studied. For reconstruction of the delivered dose distribution, we divided each original arc beam into control-point-wise sub-beams, and applied beam isocenter shifting to each sub-beam to reflect the tumor motion. The tumor positions as a function of beam delivery were estimated by synchronizing the beam delivery with the respiratory signal which acquired during treatment. For this purpose, an in-house program (MATLAB, Mathworks) was developed to convert the original DICOM plan data into motion-involved treatment plan. The motion-involved DICOM plan was imported into Eclipse for dose calculation. The reconstructed delivered dose was compared to the plan dose using the dose coverage of gross tumor volume (GTV) and dose distribution of organs at risk (OAR). Results: The mean GTV dose coverage difference between the reconstructed delivered dose and the plan dose was 0.2 % in lung and pancreas cases, and no difference in liver cases. Mean D1000cc of ipsilateral lungs was reduced (0.8 ± 1.4cGy). Conclusion: We successfully developed a method of delivered dose reconstruction taking into account both respiratory tumor motion and dynamic beam delivery, and applied it to abdominal tumors treated with gated VAMT. No significant deterioration of delivered dose distribution indicates that interplay effect would be minimal even in the case of gated SBRT. This work was supported by the National Research Foundation of Korea (NRF) grant funded by the Korea government (MSIP) (No. 2015038710)

60 APPLIED LIFE SCIENCES↗