Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “detector development”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

Advanced Mixed-Mode Pixel Array Detector for X-rays Above 20 keV (Final Report)

The objective of the work reported upon was to perform research and development and test advanced prototype imaging x-ray detectors needed to meet pressing scientific research needs at U.S. x-ray synchrotron user facilities. The high x-ray brightness of the Nation’s x-ray synchrotron sources in the DOE National Laboratories holds promise to advance science and technology in a broad range of fundamental and applied disciplines, including physics, chemistry, biomedical areas and engineering. At present, progress in many areas is being limited not by the x-ray source but by the lack of imaging x-ray detectors capable of meeting experimental needs. Specifically, there is pressing need for imaging detectors with high dynamic range, low noise, high frame rates and the ability to capture x-ray images with x-rays of energy > 20 keV. This Final Technical Report summarizes progress made at Cornell University on novel integrating x-ray detectors that address these characteristics.

36 MATERIALS SCIENCE↗

Performance of a geometric deep learning pipeline for HL-LHC particle tracking

The Exa.TrkX project has applied geometric learning concepts such as metric learning and graph neural networks to HEP particle tracking. Exa.TrkX’s tracking pipeline groups detector measurements to form track candidates and filters them. The pipeline, originally developed using the TrackML dataset (a simulation of an LHC-inspired tracking detector), has been demonstrated on other detectors, including DUNE Liquid Argon TPC and CMS High-Granularity Calorimeter. This paper documents new developments needed to study the physics and computing performance of the Exa.TrkX pipeline on the full TrackML dataset, a first step towards validating the pipeline using ATLAS and CMS data. The pipeline achieves tracking efficiency and purity similar to production tracking algorithms. Crucially for future HEP applications, the pipeline benefits significantly from GPU acceleration, and its computational requirements scale close to linearly with the number of particles in the event.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Exploring the Potential of Residual Impurities in Germanium Detectors for MeV-Scale Dark Matter Detection

Abstract The direct detection of MeV-scale dark matter (DM) particles hinges on achieving an exceptionally low-energy detection threshold. Germanium (Ge) detectors, meticulously tailored with precise impurity compositions, hold the potential to enhance sensitivity to energy levels below the sub-electronvolt (sub-eV) range. This study explores the behavior of residual impurities inherent to Ge detectors at helium temperatures, unveiling a captivating freeze-out phenomenon leading to the formation of excited localized states known as dipole states. Using compelling evidence from relative capacitance measurements obtained from two detectors, we elucidate the transition of impurity atoms from free charge states to these dipole states as the temperature drops from 11 to 6.5 K. Our investigation comprehensively covers the intricate formation of these dipole states in bothn-type andp-type impurities. Furthermore, we shed light on the electric field generated by these dipole states, revealing their ability to trap charges and facilitate the creation of cluster dipole states. Confirming findings from previous measurements, we establish that these excited dipole states exhibit a binding energy of less than 10 meV, offering an exceptionally low detection threshold for MeV-scale DM. Building upon this concept, we propose the development of a 1-kg Ge detector with internal charge amplification—an innovative approach poised to surpass electrical noise and enable the detection of MeV-scale DM with unprecedented sensitivity.

Physics↗

Fine-Pitch CdTe Detector for Hard X-Ray Imaging and Spectroscopy of the Sun with the FOXSI Rocket Experiment

We have developed a fine-pitch hard X-ray (HXR) detector using a cadmium telluride (CdTe) semiconductor for imaging and spectroscopy for the second launch of the Focusing Optics Solar X-ray Imager (FOXSI). FOXSI is a rocket experiment to perform high sensitivity HXR observations from 4 to 15 keV using the new technique of HXR focusing optics. The focal plane detector requires less than 100 micrometers position resolution (to take advantage of the angular resolution of the optics) and approximately equals 1 keV energy resolution (full width at half maximum (FWHM)) for spectroscopy down to 4 keV, with moderate cooling (greater than -30 C). Double-sided silicon strip detectors were used for the first FOXSI flight in 2012 to meet these criteria. To improve the detectors' efficiency (66% at 15 keV for the silicon detectors) and position resolution of 75 micrometers for the second launch, we fabricated double-sided CdTe strip detectors with a position resolution of 60 micrometers and almost 100% efficiency for the FOXSI energy range. The sensitive area is 7.67 mm x 7.67 mm, corresponding to the field of view of 791'' x 791''. An energy resolution of 1 keV (FWHM) and low-energy threshold of approximately equals 4 keV were achieved in laboratory calibrations. The second launch of FOXSI was performed on 11 December 2014, and images from the Sun were successfully obtained with the CdTe detector. Therefore, we successfully demonstrated the detector concept and the usefulness of this technique for future HXR observations of the Sun.

Ishikawa, Shin-nosuke↗

The brighter-fatter effect in the JWST MIRI Si:As IBC detectors: I. Observations, impact on science, and modeling

Context.The Mid-Infrared Instrument (MIRI) on board theJames WebbSpace Telescope (JWST) uses three Si:As impurity band conduction (IBC) detector arrays. The output voltage level of each MIRI detector pixel is digitally recorded by sampling up the ramp. For uniform or low-contrast illumination, the pixel ramps become nonlinear in a predictable way, but in areas of high contrast, the nonlinearity curve becomes much more complex. The origin of the effect is poorly understood and currently not calibrated out of the data. Aims.We provide observational evidence of the brighter-fatter effect (BFE) in MIRI conventional and high-contrast coronagraphic imaging, low-resolution spectroscopy, and medium-resolution spectroscopy data, and we investigate the physical mechanism that gives rise to the effect on the MIRI detector pixel raw voltage integration ramps. Methods.We used public data from the JWST/MIRI commissioning and Cycle 1 phase. We also developed a numerical electrostatic model of the MIRI detectors using a modified version of the publicPoisson_CCDcode. Results.We find that the physical mechanism behind the BFE manifesting in MIRI data is fundamentally different to that of charge-coupled devices and photodiode arrays such as the Hawaii-XRG near-infrared detectors used by the NIRISS, NIRCam, and NIRSpec instruments on board JWST. Observationally, the BFE makes the JWST MIRI data yield 10–25% larger point sources and spectral line profiles as a function of the relative level of de-biasing of neighboring detector pixels. This broadening impacts the MIRI absolute flux calibration, time-series observations of faint companions, and point spread function modeling and subtraction. We also find that the intra-pixel 2D profile of the shrinking Si:As IBC detector depletion region directly impacts the accuracy of the pixel ramp nonlinearity calibration model.

Astronomy & Astrophysics↗

A directional gamma-ray telescope using coded aperture techniques

A directional detector for gamma-ray astronomy has been developed to image sources in the energy range 0.1 to 5 MeV. An array of 35 gain stabilized bismuth germanate detectors, together with a coded aperture mask based on a uniformly redundant array allows imaging in 4 deg square sky bins over a 16 x 24 deg field-of-view. The position of a strong point source, such as the Crab Nebula, can be determined to within not more than about 1 deg. A complementary 'anti-mask' greatly reduces systematic effects arising from nonuniform background rates amongst the detectors. The telescope has an effective area of 190 sq cm and an energy resolution of 19.5 percent FWHM at 662 keV. Results of laboratory tests of the imaging system, including the ability to image multiple sources, uniformity of response over the field-of-view, and the effect of the 'anti-mask', are in good agreement with computer simulations. Features of the flight detector system are described and results of laboratory tests and computer simulations are reviewed. A balloon flight of the telescope is planned for the fall of 1982.

Mcconnell, M. L.↗

Overview of the NASA LISA Laser System Development

NASA Goddard Space Flight Center (GSFC) is developing the Laser System (LS) for the Laser Interferometer Space Antenna (LISA) mission, led by the European Space Agency (ESA) with a launch date of 2035. The LS under development at NASA GSFC consists of the Laser Head (LH), the Frequency Reference System (FRS), and the Power Monitor (PMON) Detector Assemblies. Since late 2017, we have been developing various models to advance the technology readiness level (TRL) for the LH from prototype (TRL4) to a system model demonstration in a relevant environment (TRL6). For the LH and FRS, the models further breakdown into the optical and electronics modules where the LH is made up of the Laser Optical Module (LOM) and the Laser Electronics Module (LEM) and the FRS consists of the FRS Optical Reference Cavity (FRS-O) and the FRS Electronics (FRS-E). The LS development follows the established NASA process in demonstrating the performance requirements [1] through the TRL4 effort and then advancing the form factor and package design to meet relevant environment requirements and qualifying the TRL6 design through rigorous testing and performance verification for space applications. The LOM for the LH is a main oscillator power amplifier (MOPA) with wavelength of 1064 nm and nominal output power of 2 Watt throughout the mission. The low-power, low-noise main oscillator (MO) is a custom micro non-planar ring oscillator (µNPRO) [2] that is phase modulated then amplified by the forward pumped ytterbium-dope fiber power amplifier (PA) stage to meet the output power requirement. The FRS is baselined on the GRACE Follow-On (GFO) [3] approach with updated FRS-E design to work with the LH-LEM. The PMON is located on the Optical Bench Assembly (OBA) [4] that samples a small portion of the LH output signal and provides the feedback signal to the LH-LEM for relative intensity noise (RIN) control. In this paper, we will report on the latest status of the LH testing and system level tests, explain the other subsystems involved in the test campaigns, and discuss the path to bring each LS subsystem to TRL6. We will also present the NASA GSFC roadmap in advancing the LISA LS to TRL6+ and plans for future system level testing as well as the preparation for space flight development to meet the LISA launch date of 2035.

amplifier↗

Development of a pattern recognition algorithm for reconstructing multi-particle events in the Mu2e detector

Mu2e is an upcoming experiment at Fermilab and its main goal is to search for the Charged Lepton Flavor Violation (CLFV) in the coherent transition of a muon into an electron on an Al target. In Mu2e, multi-particle events can occur simultaneously within the same time region and it is crucial to accurately identify each particle track, including signals, to improve the robustness of track finding methods and enhance reconstruction efficiency. ¯p annihilation is one of the background events and produces multiple particles that can mimic signal events. Additionally, photons from radiative pion captures can produce a γ → $e+e−$ pair, which can be used to calibrate the Mu2e momentum scale and the resolution. The Mu2e track reconstruction sequence begins by grouping hits produced in the tracker based on time and z coordinate information, called TimeCluster, and selected hits are processed to reconstruct helices and determine their momentum. The current pattern recognition algorithms identify a single helix per TimeCluster for single track events. A new pattern recognition algorithm is being developed to reconstruct multi-particle events and its features for finding multiple tracks and the current evaluation results are reported.

Kitagawa, H. [Pisa U.]↗

Initial OSSE Sky Survey Observation: Deep Survey in the Virgo Region

The OSSE Virgo survey covered about 1% of the sky, using eight weeks of observing time on the Compton Gamma Ray Observatory, and was performed in conjunction with the EGRET and COMPTEL instruments on CGRO. A fundamental aspect of the survey was the development of data reduction techniques for the scanning data from the OSSE detectors. A direct algebraic approach for spatially deconvolving the data was developed. For the survey work, no background observations isolated from the survey region were acquired, unlike normal discrete source observations. The survey, reduction method covers the mapped region with a grid of pixels, and estimates the flux from each pixel by least-squares agreement with the data, assuming positivity constraints. This technique has led to the detection of compact sources at hard X-ray energies within the Virgo region, and the OSSE survey studies have been extended to the south galactic pole and north Ecliptic pole, with similar analysis techniques.

Cameron, Robert↗

Tools used in Space Radiation Operations

The goal of NASA's Radiation Health Program is to achieve human exploration and development of space without exceeding acceptable risk from exposure to ionizing radiation. The Space Radiation Analysis Group (SRAG) at NASA Johnson Space Center carries out this mission by following the philosophy of ALARA – As Low as Reasonably Achievable. SRAG utilizes a variety of tools to maintain awareness of space weather and to monitor the space radiation environment, both internal and external to the vehicle. SRAG develops and manages a wide variety of detectors that are located on the exterior and throughout the interior of the International Space Station and worn by crew. During Artemis I, SRAG provided detectors distributed within Orion’s interior and participated in the MARE experiment, which outfitted female phantoms with thousands of thermoluminescence detectors (TLD) and other dosimeters to better constrain the total dose accrued inside the human during a mission to the Moon. Motivated by the Artemis Exploration Class missions, SRAG and collaborators are developing forecasting capabilities for solar energetic particle (SEP) events and their biological impacts to crew. Tools that have come out of this work include the Acute Radiation Risk Tool (ARRT) and the SEP Scoreboards. This presentation will give an overview of the tools used in SRAG ops and currently under development to support our next steps in human space exploration.

space weather↗

Simulation and Characterization of a Miniaturized Scanning Electron Microscope

A miniaturized Scanning Electron Microscope (mSEM) for in-situ lunar investigations is being developed at NASA Marshall Space Flight Center with colleagues from the University of Alabama in Huntsville (UAH), Advanced Research Systems (ARS), the University of Tennessee in Knoxville (UTK) and Case Western Reserve University (CWRU). This effort focuses on the characterization of individual components of the mSEM and simulation of the complete system. SEMs can provide information on the size, shape, morphology and chemical composition of lunar regolith. Understanding these basic properties will allow us to better estimate the challenges associated with In-Situ Resource Utilization and to improve our basic science knowledge of the lunar surface (either precluding the need for sample return or allowing differentiation of unique samples to be returned to Earth.) The main components of the mSEM prototype includes: a cold field emission electron gun (CFEG), focusing lens, deflection/scanning system and backscatter electron detector. Of these, the electron gun development is of particular importance as it dictates much of the design of the remaining components. A CFEG was chosen for use with the lunar mSEM as its emission does not depend on heating of the tungsten emitter (lower power), it offers a long operation lifetime, is orders of magnitude brighter than tungsten hairpin guns, has a small source size and exhibits low beam energy spread.

Gaskin, Jessica A.↗

Gas detector tube applications on Space Station Freedom

The Space Station Freedom (SSF) program requires measurements, by gas detector tubes, of trace contaminants (mainly CO and toluene didsocyanate) in the Node 2 (which is isolated from the trace contaminant control system for about 100 days during the SSF building missions) and Lab A atmosphere prior to the first entry of the crew. This paper discusses the results of an analysis of the levels of trace contaminants that can be expected in the Node 2 atmosphere at 100 days and the aspects of the detector tube design and technology which may need further developent for application in microgravity. Attention is also given to the factors governing the use of detector tubes for monitoring selected contaminants.

Shah, Burt H.↗

Development of far infrared detection techniques

This grant supports the development of a variety of advanced far infrared detection techniques that will be used in future NASA missions such as the Space Infrared Telescope Facility (SIRTF). These studies span the wavelength region of 30-200 microns and include development of focal planes and electronics that would utilize them. Efforts reported here represent collaborations among the University of Arizona's Steward Observatory; Lawrence Berkeley Laboratories (LBL); and the University of California at Berkeley. The overall goal of this program is to demonstrate extremely high performance detectors for low background applications between 30-200 microns. For the 40-120 micron region, the program is developing a 32x32 filled detector array. Previous work has demonstrated the required performance with a Z-Plane array architecture; we are now upgrading construction facilities and techniques to increase yields and reliability. We have completed the initial tradeoff analysis for the interconnects between the detectors and and readouts. We found satisfactory performance for both Flex-Cable and Tape Automated Bonding (TAB) devices, but analysis showed that an all-sapphire device would not meet our requirements. In addition, the effort continued to develop readouts that can operate close to the detector element temperature; success would substantially improve the manufacturability of the arrays. For the 100-200 micron range, previous work has demonstrated good performance with individual detector elements of stressed Ge:Ga; current efforts are to increase the quantum efficiency of these devices. Work continues to discover how to construct an alternate type of long wave detector, Ge:B Blocked Impurity Band devices. Following descoping of SIRTF, we are closing out the bolometer and refrigerator development. We documented the optical designs and approaches developed previously to meet the specific requirements of these detector types in terms of modulation of the signals for good photometric behavior within the constraints of a compact and self-contained cryogenic instrument. Further study was initiated for the Band 3 optical train, where we have concerns about complexity and the manufacturability of one component.

Rieke, George↗

Technical issues in focal plane development for terrestrial resource observations

Performance goals for solid-state detector arrays operating in the pushbroom scan mode for the high-resolution, high-accuracy remote sensing of earth resources from space are discussed and some of the focal plane and system trades involved are identified. Issues in the development of solid-state pushbroom arrays with radiometric calibration to 0.5% precision detector-to-detector over a dynamic range of 1000:1 are considered, with calibration, temporal stability and spectral response conditions noted. Factors influencing the geometric precision of satellite-borne pushbroom scan mode sensors are then examined, including satellite orbit track and attitude errors, and geometric and radiometric correlation between information in the various spectral bands. Approaches to the alignment of linear arrays of thousands of detectors are then discussed that take into account tradeoffs between fabrication and test complexity and ground processing requirements. Continuing science experiments are indicated as necessary to establish tolerances on performance goals.

Thompson, L. L.↗

GADRAS Batch Inject Tool User Guide

Gamma Detector Response and Analysis Software (GADRAS) is used by the radiation detection and emergency response community to perform modeling and spectral analysis for gamma detector systems. Built into GADRAS is the ability to define a detector, geometry, background characteristics and source composition to generate synthetic spectra for drills and exercises (injects). Consequence Management is currently in development of a sample result data simulator tool in which a deposition model is probed for source conditions at moments in time and locations in space. These values are used to generate realistic sample results for use in drills and exercises. In addition to sample results, there is a need to simulate the actual spectra that would be observed in the field by downlooking HPGe instruments given a deposition activity. This way, the FRMAC Gamma Spectroscopist can practice their process of generating quantified results from spectra on realistic data as well. Recognizing the decades of work done in GADRAS to accurately generate synthetic spectra, this team decided to build a link between the new simulator and GADRAS to generate these spectra quickly and easily. The simulator tool will generate a file that specifies the name of the spectra, its location, date/time of measurement, duration of measurement, height off the ground, and the deposition activity and age for every radionuclide in the simulation. Then, a new tool within the Inject Tab of GADRAS was developed to read in this file given a detector selection and generate In-Situ spectra for each row in the file in any file format the user chooses. This way, simulation cell staff can take these files and then upload them to the appropriate data system (RAMS or RadResponder) for use during drills and exercises. An advanced feature of this tool allows for generating any spectra given an appropriate model and mapping of source to model layer in the batch inject tool. This way, spectra from field sample counts, mobile laboratories, or even fixed laboratories can be generated in bulk given an estimate of the radioactivity concentration or total radioactivity in an import file. This expands the capabilities of this tool a great deal and will make it a more useful tool for CM and others to help estimate detector response for nearly any situation. This user guide will explain the steps needed to perform a batch inject file generation.

61 RADIATION PROTECTION AND DOSIMETRY↗

Photon counting image sensor development for astronomical applications

Specially built intensified CCD (ICCD) detector tubes were purchased and the performance of the electron bombardment process was investigated. In addition to studying the signal characteristics of the photoevents, there was interest in demonstrating that back-illuminated chips were not susceptible to radiation damage to their clocking electrodes. How to perform a centroid analysis for a 2-dimensional Gaussian distribution of charge is described. Measurement of the projection (along columns or rows) of the average charge spread profile is discussed. The development and flight of the Interstellar Medium Absorption Profile Spectrograph (IMAPS) is discussed.

Jenkins, Edward B.↗

The Double Chooz antineutrino detectors

This article describes the setup and performance of the near and far detectors in the Double Chooz experiment. The electron antineutrinos of the Chooz nuclear power plant were measured in two identically designed detectors with different average baselines of about 400 m and 1050 m from the two reactor cores. Over many years of data taking the neutrino signals were extracted from interactions in the detectors with the goal of measuring a fundamental parameter in the context of neutrino oscillation, the mixing angle $\theta _{13}$. The central part of the Double Chooz detectors was a main detector comprising four cylindrical volumes filled with organic liquids. From the inside towards the outside there were volumes containing gadolinium-loaded scintillator, gadolinium-free scintillator, a buffer oil and, optically separated, another liquid scintillator acting as veto system. Above this main detector an additional outer veto system using plastic scintillator strips was installed. The technologies developed in Double Chooz were inspiration for several other antineutrino detectors in the field. The detector design allowed implementation of efficient background rejection techniques including use of pulse shape information provided by the data acquisition system. The Double Chooz detectors featured remarkable stability, in particular for the detected photons, as well as high radiopurity of the detector components.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗