Suitability of silica aerogel as a capture medium for interplanetary dust
Impact experiments using silica aerogel as a deceleration and capture medium for interplanetary dust are reported. A rough correlation is noted between increasing particle track lengths and decreasing aerogel density, and there is a poor correlation of track lengths with impact velocity at laboratory attainable velocities of 5-7 km/s. It is concluded that aerogel track lengths should not be used as velocity indicators. Chemical analyses are also reported of aerogel samples used in this study in order to assess the risks concerning contamination of interplanetary dust particles by the silica aerogel capture medium. It is demonstrated that this material is impressively clean.