Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

Predictive Data Analytics Framework Using Advanced Test Reactor Acoustic Data

Although a nuclear reactor is a hostile environment for sensing and electrical communications, the reactor core is amenable to acoustic communication. An acoustic measurement infrastructure (AMI) has been installed at the Advanced Test Reactor (ATR) nozzle trench area to record acoustic signals that has the ability to capture different operating regime of the reactor. This AMI includes ATR in-pile structural components, coolant, acoustic receivers, primary coolant pumps (PCP) as signal sources, a data acquisition system, and signal-processing algorithms, enabling real-time. This report will discusses development of recursive Fast Fourier Transform approach to process in real-time acoustic signals, application of short time Fast Fourier Transform to the ATR brush data to understand the vibration level and to develop spectrograms for different primary coolant pump combinations. The combination of primary coolant pumps for normal and power axial locator mechanism of ATR are different and generates different signatures. These acoustic signatures were used to develop machine learning approaches to automatically classify different operating regimes. This lay the foundation for predictive analytic framework that can be leverage by ATR to optimize their operation and maintenance. The path forward involves continued engagement with ATR and expanded implementation of AMI and predictive framework at ATR and other facilities within INL and at other experimental reactors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Project Update for “Designing Nuclear-data Measurements that Resolve Discrepancies in Existing Data” [Slides]

AIACHNE has made key progress this past year and will contribute to the larger scientific community. We recovered input data for the current 252 Cf(sf) PFNS evaluation that was previously lost. We render a standard to the best of our ability reproducible. We critically reviewed past data as input for ML & new standard evaluation that will impact PFNS of all major actinides. We developed a unique AI/ ML code that highlights which measurement features are related to bias and are working towards open-sourcing it for the community. Features that were identified as related to bias follow physics’ intuition and bring new understanding of exp effects and might help us for other reactions and isotopes. The results highlight that EXFOR is a goldmine of features that could help us understand experiment bias (if they are easy to parse).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

HME MicroCT Data Acquisition, Processing and Data Request Overview

This document is a short summary of the steps required for MicroCT evaluation of a specimen. This includes data acquisition through image analysis, for the Explosives Threat Assessment (ETA) program. Expected outputs for each stage are outlined. Information and data shall be shipped to LLNL as described herein.

42 ENGINEERING↗

Technical Track on Biomass Carbon Removal and Storage (BiCRS): Mapping bioresources, phase 1 - Consistency check comparing Mission Innovation’s Data Visualization Tool for Bioresources and the Clean Energy Ministerial Biofuture Initiative Global Biomass data accessible via the US Department of Energy’s Bioenergy Knowledge Discovery Framework (KDF)

The Mission Innovation (MI) Carbon Dioxide Removal (CDR) Mission, Technical Track on Biomass Carbon Dioxide Removal and Storage (BiCRS), has produced a biomass resource database for its members. In parallel, Oak Ridge National Laboratory (ORNL) developed the International Feedstock Reporting data portal—herein referred to as the CEM Biofuture-KDF data—on behalf of the Clean Energy Ministerial Biofuture Initiative (CEM Biofuture), as a specific task under Biofuture’s 2024–25 Action Plan. This work was conducted at the request of CEM Biofuture and funded by the U.S. Department of Energy in support of that initiative, and it is hosted within DOE’s Knowledge Discovery Framework (KDF).

09 BIOMASS FUELS↗

Data Assimilation Tools for CO2 Reservoir Model Development – A Review of Key Data Types, Analyses, and Selected Software

Pacific Northwest National Laboratory (PNNL) has embarked on an initiative to develop world-class capabilities for performing experimental and computational analyses associated with geologic sequestration of carbon dioxide. The ultimate goal of this initiative is to provide science-based solutions for helping to mitigate the adverse effects of greenhouse gas emissions. This Laboratory-Directed Research and Development (LDRD) initiative currently has two primary focus areas—advanced experimental methods and computational analysis. The experimental methods focus area involves the development of new experimental capabilities, supported in part by the U.S. Department of Energy’s (DOE) Environmental Molecular Science Laboratory (EMSL) housed at PNNL, for quantifying mineral reaction kinetics with CO2 under high temperature and pressure (supercritical) conditions. The computational analysis focus area involves numerical simulation of coupled, multi-scale processes associated with CO2 sequestration in geologic media, and the development of software to facilitate building and parameterizing conceptual and numerical models of subsurface reservoirs that represent geologic repositories for injected CO2. This report describes work in support of the computational analysis focus area. The computational analysis focus area currently consists of several collaborative research projects. These are all geared towards the development and application of conceptual and numerical models for geologic sequestration of CO2. The software being developed for this focus area is referred to as the Geologic Sequestration Software Suite or GS3. A wiki-based software framework is being developed to support GS3. This report summarizes work performed in FY09 on one of the LDRD projects in the computational analysis focus area. The title of this project is Data Assimilation Tools for CO2 Reservoir Model Development. Some key objectives of this project in FY09 were to assess the current state-of-the-art in reservoir model development, the data types and analyses that need to be performed in order to develop and parameterize credible and robust reservoir simulation models, and to review existing software that is applicable to these analyses. This report describes this effort and highlights areas in which additional software development, wiki application extensions, or related GS3 infrastructure development may be warranted.

54 ENVIRONMENTAL SCIENCES↗

Aircraft Flight Data - Long-EZ aircraft - Raw Data

IMPOWR_EZF_QC_20Hz_YYYYMMDD.txt These files contain the observational data from the EZFlight aircraft that was taken and has been processed by the Stonybrook team. All data here is 20 Hz.

17 WIND ENERGY↗

UAE6 - Wind Tunnel Tests Data - UAE6 - Sequence Q - Raw Data

Sequence Q: Dynamic Inflow (P) This sequence was designed to characterize the dynamic inflow variation using the five-hole probes that extend upwind of the leading edge of the blade. This test sequence used an upwind, rigid turbine with a 0° cone angle. The wind speeds ranged from 5 m/s to 15 m/s, and data were collected at a 0° yaw angle. The rotor rotated at 72 RPM. Blade and probe pressure measurements were collected. The teeter dampers were replaced with rigid links, and these two channels were flagged as not applicable by setting the measured values in the data file to -99999.99 Nm. The teeter link load cell was pretensioned to 40,000 N. The blade pitch angle was changed from the initial tip pitch angle to the final tip pitch angle at the maximum rate of 67°/s. This angle was maintained for the specified delay time duration. Then the blade was pitched back to the initial pitch angle and held for the specified hold time. This was repeated 20 times. The campaign at 15 m/s was aborted early due to excessive low-speed shaft torque loads. The file length varied depending on the time required to obtain 20 pitch cycles for the specified range of angles. The name convention was the standard format, except for the short campaigns collected to ascertain the functionality of the instrumentation. These points were collected at a 3° pitch angle and use the characters REF in the four digits that normally represent yaw angle.

17 WIND ENERGY↗

UAE6 - Wind Tunnel Tests Data - UAE6 - Sequence E - Raw Data

Sequence E: Yaw Releases (P) This test sequence used a downwind, rigid turbine with a 3.4° cone angle. The wind speeds ranged from 7 m/s to 17 m/s. Initial yaw angles of ±90° were achieved. The blade tip pitch was 3°. The rotor rotated at 72 RPM. Blade and probe pressure measurements were collected. The teeter dampers were replaced with rigid links, and these two channels were flagged as not applicable by setting the measured values in the data file to –99999.99 Nm. The teeter link load cell was pre-tensioned to 40,000 N. The turbine was positioned at each specified yaw angle. A 30- second data set was collected with the yaw brake engaged. These points used a letter for the last digit beginning with A and proceeding through the alphabet as repeat points were needed. These points were plotted and compared to ascertain the functionality of the instrumentation. The files ending in numbers beginning with 0 and increasing with each repetition represent yaw release points. Once the fixed-position yaw test was complete, the yaw drive was engaged to hold the turbine. The yaw brake was released, and the yaw drive was disabled allowing the turbine to yaw freely. The yaw drive was disabled about 5 seconds into the campaign, and the turbine was allowed to yaw freely for the rest of the 30-second duration. When the yaw drive is disabled, no torque is applied to the motor, and the inertia and yawing force of the nacelle and rotor overcomes the friction and inertia of the yaw gear and motor. The yaw releases were repeated five times at each condition. Four additional campaigns were collected to determine the turbine’s natural yaw error by releasing the brake at 0° yaw error. These file names use the E designation, followed by two digits for wind speed, followed by XXXX, followed by the repetition digit.

17 WIND ENERGY↗

UAE6 - Wind Tunnel Tests Data - UAE6 - Sequence F - Raw Data

Sequence F: Downwind High Cone (F) This test sequence used a downwind, rigid turbine with an 18° cone angle. The wind speed ranged from 10 m/s to 20 m/s. Excessive inertial loading due to the high cone angle prevented operation at lower wind speeds. Yaw angles of ±20° were achieved. The blade tip pitch was 3°. The rotor rotated at 72 RPM. Blade and probe pressure measurements were collected. The teeter dampers were replaced with rigid links, and these two channels were flagged as not applicable by setting the measured values in the data file to –99999.99 Nm. The teeter link was replaced with a shorter bar so the load cell was not installed during this test. However, the teeter link load cell channel was flagged as not applicable by setting the measured values in the data file to -99999.99 N.

17 WIND ENERGY↗

UAE6 - Wind Tunnel Tests Data - UAE6 - Sequence K - Raw Data

Sequence K: Step AOA, Probes (P) This sequence was designed to quantify the 3-D blade static angle-of-attack response in the presence of rotational influences by varying the blade pitch angle. Sequence K used an upwind, rigid turbine with a 0° cone angle. The wind speeds ranged from 6 m/s to 20 m/s, and data were collected at yaw angles of 0° and 30°. The rotor rotated at 72 RPM. Blade and probe pressure measurements were collected. The teeter dampers were replaced with rigid links, and these two channels were flagged as not applicable by setting the measured values in the data file to -99999.99 Nm. The teeter link load cell was pre-tensioned to 40,000 N. The blade pitch angle ramped continuously at 0.18°/s over a wide range of increasing and decreasing pitch angles. A step sequence was also performed. The blade pitch was stepped 5°, the flow was allowed to stabilize, and the pitch angle was held for 8 seconds. Then the pitch angle step was repeated. Again, a wide range of pitch angles was obtained, both increasing and decreasing. The file lengths for this sequence varied from 96 seconds to 6 minutes, depending on the pitch angle range. Some short points were collected at 0° yaw and 3° pitch to verify the functionality of the instrumentation. The file name convention used the initial letter K, followed by two digits specifying wind speed, followed by two digits for yaw angle, followed by RU, RD, or ST, followed by the repetition digit. The angle-of-attack motion was differentiated by RU (ramp up), RD (ramp down), and ST (step down then step up). This sequence is related to sequences L and R.

17 WIND ENERGY↗

UAE6 - Wind Tunnel Tests Data - UAE6 - Sequence L - Raw Data

Sequence L: Step AOA, Parked (P) This sequence was designed to quantify the 3-D blade static angle-of-attack response in the absence of rotational influences by varying the blade pitch angle. This test sequence used an upwind, rigid turbine with a 0° cone angle. Wind speeds of 20 m/s and 30 m/s were used, and all data were collected at a yaw angle of 0°. The rotor was parked with the instrumented blade fixed at 0° azimuth, and the rotor lock was installed (see Appendix A). Blade and probe pressure measurements were collected. The teeter dampers were replaced with rigid links, and these two channels were flagged as not applicable by setting the measured values in the data file to -99999.99 Nm. The teeter link load cell was pre-tensioned to 40,000 N. The blade pitch angle ramped continuously at 0.18°/s over a wide range of increasing and decreasing pitch angles. A step sequence was also performed. The blade pitch was stepped 5°, the flow was allowed to stabilize, and the pitch angle was held for 8 seconds. Then the pitch angle step was repeated. Again, a wide range of pitch angles was obtained, both increasing and decreasing. The file lengths for this sequence varied from 5 to 10 minutes, depending on the pitch angle range. The file name convention used the initial letter L followed by two digits specifying wind speed, followed by 00 for yaw angle, followed by RU, RD, or ST, followed by the repetition digit. The angle-of-attack motion was differentiated by RU (ramp up), RD (ramp down), and ST (step down, then step up). This sequence is related to sequences K and R.

17 WIND ENERGY↗

UAE6 - Wind Tunnel Tests Data - UAE6 - Sequence N - Raw Data

Sequence N: Sin AOA, Rotating (P) This sequence was designed to quantify the blade 3-D unsteady aerodynamic response in the presence of rotational influences by varying blade pitch angle. Test sequence N used an upwind, rigid turbine with a 0° cone angle. The wind speed was 15 m/s, and the yaw angle was 0° throughout the sequence. The rotor rotated at 72 RPM. Blade and probe pressure measurements were collected. The teeter dampers were replaced with rigid links, and these two channels were flagged as not applicable by setting the measured values in the data file to –99999.99 Nm. The teeter link load cell was pre-tensioned to 40,000 N. Sinusoidal angle-of-attack histories were designed to emulate 2-D S809 dynamic data obtained at the Ohio State University (OSU) wind tunnel (Reuss Ramsey et al. 1995) and the 1P yawed flow angle-of-attack variations the turbine could be expected to encounter in routine operation. The reduced frequency (K), mean angle of attack (αm), and oscillation amplitude (αω) were computed for each of the five primary span locations. The file lengths varied according to the time required to complete 40 oscillations at the specified frequency. The file name convention used the sequence designation N, followed by two digits for the span location (30, 47, 63, 80, or 95), followed by two digits representing the condition specified in the test matrix, followed by the repetition digit. Due to time constraints, most of the test conditions corresponding to the 63% span location were eliminated. Test points with a static pitch angle of 3° were collected throughout the sequence to ascertain instrumentation fidelity.

17 WIND ENERGY↗

UAE6 - Wind Tunnel Tests Data - UAE6 - Sequence O - Raw Data

Sequence O: Sin AOA, Parked (P) This sequence was designed to quantify the blade 3-D unsteady aerodynamic response in the absence of rotational influences by varying blade pitch angle. This test sequence used an upwind, rigid turbine with a 0° cone angle. The wind speed ranged from 18.9 m/s to 39.3 m/s, and the yaw angle was 0° throughout the sequence. The rotor was parked with the instrumented blade fixed at 0° azimuth, and the rotor lock was installed (see Appendix A). Blade and probe pressure measurements were collected. The teeter dampers were replaced with rigid links, and these two channels were flagged as not applicable by setting the measured values in the data file to -99999.99 Nm. The teeter link load cell was pre-tensioned to 40,000 N. Sinusoidal angle-of-attack histories were designed to emulate 2-D S809 dynamic data obtained at the OSU wind tunnel (Reuss Ramsey et al. 1995) as well as 1P yawed flow angle-of-attack variations the turbine could be expected to encounter in routine operation. The reduced frequency (K), mean angle of attack (αm), and oscillation amplitude (αω) were computed for each of the five primary span locations. The file lengths varied according to the time required to complete 40 oscillations at the specified frequency. The file name convention used the sequence designation O, followed by two digits for the span location (30, 47, 80, or 95), followed by two digits representing the condition specified in the test matrix, followed by the repetition digit. Due to time constraints, the test conditions corresponding to the 63% span location were eliminated. Test points with a static pitch angle of 3° were collected throughout the sequence to ascertain instrumentation fidelity.

17 WIND ENERGY↗

UAE6 - Wind Tunnel Tests Data - UAE6 - Sequence R - Raw Data

Sequence R: Step AOA, No Probes (P) This sequence was designed to quantify the effect of the five-hole probes on the 3-D blade static angle-of-attack response in the presence of rotational influences by repeating Sequence K without five-hole probes. This test sequence used an upwind, rigid turbine with a 0° cone angle. The wind speeds ranged from 6 m/s to 20 m/s, and data were collected at yaw angles of 0° and 30°. The rotor rotated at 72 RPM. Blade pressure measurements were collected. The five-hole probes were removed and the plugs were installed. Plastic tape 0.03-mm-thick was used to smooth the interface between the plugs and the blade. The teeter dampers were replaced with rigid links, and these two channels were flagged as not applicable by setting the measured values in the data file to –99999.99 Nm. The teeter link load cell was pre-tensioned to 40,000 N. During post-processing, the probe channels were set to read –99999.99. The blade pitch angle ramped continuously at 0.18°/s over a wide range of increasing and decreasing pitch angles. A step sequence was also performed. The blade pitch was stepped 5°; the flow was allowed to stabilize; and the pitch angle was held for 5 seconds. Then the pitch angle step was repeated. Again, a wide range of pitch angles was obtained, both increasing and decreasing. The file lengths for this sequence varied from 96 seconds to 6 minutes, depending on the pitch angle range. Some short points were collected at 0° yaw and 3° pitch to ascertain the functionality of the instrumentation and repeatability over time. The file name convention used the initial letter R, followed by two digits specifying wind speed, followed by two digits for yaw angle, followed by RU, RD, or ST, followed by the repetition digit. The angle of attack motion was differentiated by RU (ramp up), RD (ramp down), and ST (step down, then step up). This sequence is related to Sequences K and L.

17 WIND ENERGY↗

UAE6 - Wind Tunnel Tests Data - UAE6 - Sequence X - Raw Data

Sequence X: Elevated RPM (F) This test sequence used an upwind, rigid turbine with a 0° cone angle. The wind speed ranged from 5 m/s to 12 m/s, and yaw angles of ±30° were obtained. The blade pitch angle was 3°. The rotor rotated at 90 RPM. Blade pressure measurements were collected. The five-hole probes were removed and the plugs were installed. Plastic tape 0.03-mm-thick was used to smooth the interface between the plugs and the blade. The teeter dampers were replaced with rigid links, and these two channels were flagged as not applicable by setting the measured values in the data file to –99999.99 Nm. The teeter link load cell was pre-tensioned to 40,000 N. During post-processing, the probe channels were set to read -99999.99. As described in Appendix F, the hydrostatic correction derived for operation at 72 RPM was applied to these data.

17 WIND ENERGY↗

U.S. Hydropower Market Report Data and Metadata (2025 update)

This database complements the U.S. Hydropower Market Report (2025 update). This update focuses on data and trends in 2024 and contextualizes this information compared to evolving high-level trends over the past 10–20 years. It contains data on U.S. hydropower (and pumped storage hydropower) development pipeline, relicenses, license surrenders, performance metrics, and supply chain.

Johnson, Megan [ORNL] (ORCID:0000000290141741)↗

Data-Driven Chance-Constrained Design of Voltage Droop Control for Distribution Networks: Preprint

This paper addresses the design of local control methods for voltage control in distribution networks with high level of distributed energy resources (DERs). The designed control methods adapt the active and reactive power output of distributed energy resources proportional to the deviation of the local measured voltage magnitudes from a reference voltage, which is referred to as droop control. Thus, the design focuses on determining the droop characteristics which satisfy network-wide voltage magnitude constraints. The uncertainty and variability of DERs renders the design of optimal droop controls very challenging. Hence, this paper proposes chance constraints to limit the risk from intermittent DERs, by designing droop control coefficients that guarantee the satisfaction of network operational constraints with a specific probability. In addition, the proposed approach relies entirely on historical data rather than assuming knowledge of the probability distributions that characterize the uncertainty of DERs. The efficacy of the proposed method is demonstrated on a 37-bus distribution feeder.

chance-constrained optimization↗