Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “customize”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

Medium-scale to large-scale implementation of cyber-physical human experiments in live traffic

Autonomous Vehicles (AVs) such as cars and trucks are being developed and tested as Cyber-Physical Human systems while the technology improves. Before these systems can achieve full autonomy, some serve as tools in the form of adaptive cruise control. The CIRCLES Consortium investigates the potential for AVs to increase fuel efficiency of highway traffic by smoothing “stop-and-go” traffic waves that result from normal human driving behavior in congestion. We have performed an experiment to evaluate the real world effects of implementing this strategy. A medium-scale experiment was performed on I-24 near Nashville, TN in August 2021. This was a precursor to a larger experiment that will take place November 2022. We examine how the human part of the experiment will change as we scale up from an 11 vehicle test (four AVs) to 100 AVs. There are many solutions to problems of the medium-scale experiment that would be inconvenient, complicate the experience, or not be practicable. The medium-scale experiment involved 11 cars of which four had a custom control algorithm installed to be engaged by the driver. The large-scale experiment will have 100 cars, all with custom control algorithm installed to act on traffic when the controller is engaged. We examine key choices made for the medium experiment, and how some will be different for the large experiment. Our experience performing the medium-scale experiment has made it clear that repeating our methods from this smaller one are inefficient or impossible if used for the large-scale experiment and will be improved.

McQuade, Sean T.↗

Co-simulation of transactive energy markets: A framework for market testing and evaluation

The proliferation of distributed energy resources (DER)—and the ability to intelligently control these assets—is re-defining the electrical distribution system. As the number of controllable devices rapidly expands, grid operators must determine how to incorporate these assets while delivering reliable, equitable, and affordable electricity. One possible approach is to establish distribution-level electricity markets and allow devices/aggregations of devices to participate in price establishment. While this approach purports some of the same benefits as the highly successful wholesale electricity markets (i.e., open competition, efficient price discovery, reduced communication overhead), this needs to be researched and quantified via an analysis platform that models distribution-level markets at the appropriate fidelity. Specifically, the simultaneous evaluation of market performance, DER performance, DER bidding approaches, and distribution feeder power quality requires modeling that spans multiple technical areas. Co-simulation has emerged as a powerful tool in addressing this type of problem, where outputs depend on a range of underlying areas of expertise and associated models. In this paper we describe a solution, as implemented in the HELICS co-simulation platform, where we include (1) high fidelity house models, (2) intelligent bidding agents, (3) a modular market integration/design, and (4) a distribution feeder model. We then present a case study where we test two different market designs: (1) a pseudo-wholesale double-blind auction, and (2) an asynchronous matching market. In this work, the markets are run under two DER penetration levels and economic results are compared to full retail net energy metering and avoided cost net metering scenarios that bookend current approaches to remuneration of DER participation. We show the potential for transactive markets to provide increased value for most customers relative to net metering (and all customers relative to avoided cost scenarios) while decreasing costs for the utility.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Brachytherapy Application With In Situ Dose Painting Administered by Gold Nanoparticle Eluters

Purpose: Recent studies show promise that administering gold nanoparticles (GNP) to tumor cells during brachytherapy could significantly enhance radiation damage to the tumor. A new strategy proposed for sustained administration of the GNP in prostate tumors is to load them into routinely used brachytherapy spacers for customizable in situ release after implantation. This in silico study investigated the intratumor biodistribution and corresponding dose enhancement over time due to GNP released from such GNP-loaded brachytherapy spacers (GBS). Method and Materials: An experimentally determined intratumoral diffusion coefficient (D) for 10-nm nanoparticles was used to estimate D for other sizes by using the Stokes-Einstein equation. GNP concentration profiles, obtained using D, were then used to calculate the corresponding dose enhancement factor (DEF) for each tumor voxel, using dose painting-by-numbers approach, for times relevant to the considered brachytherapy sources' lifetimes. The investigation was carried out as a function of GNP size for the clinically applicable low-dose-rate brachytherapy sources iodine-125 (I-125), palladium-103 (Pd-103), and cesium-131 (Cs-131). Results: Results showed that dose enhancement to tumor voxels and subvolumes during brachytherapy can be customized by varying the size of GNP released or eluted from the GBS. For example, using a concentration of 7 mg/g GNP, significant DEF (>20%) could be achieved 5 mm from a GBS after 5, 12, 25, 46, 72, 120, and 195 days, respectively, for GNP sizes of 2, 5, 10, 20, 30, and 50 nm and for 80 nm when treating with I-125. Conclusions: Analyses showed that using Cs-131 provides the highest dose enhancement to tumor voxels. However, given its relatively longer half-life, I-125 presents the most flexibility for customizing the dose enhancement as a function of GNP size. These findings provide a useful reference for further work toward development of potential new brachytherapy application with in situ dose painting administered via gold nanoparticle eluters for prostate cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Novel Form of Breast Intraoperative Radiation Therapy With CT-Guided High-Dose-Rate Brachytherapy: Results of a Prospective Phase 1 Clinical Trial

Purpose: Existing intraoperative radiation therapy (IORT) techniques are criticized for the lack of image guided treatment planning and energy deposition with, at times, poor resultant dosimetry and low radiation dose. We pioneered a novel method of IORT that incorporates customized, computed tomography (CT)-based treatment planning and high-dose-rate (HDR) brachytherapy to overcome these drawbacks: CT-HDR-IORT. Methods and Materials: A phase 1 study was conducted to demonstrate the feasibility and safety of CT-HDR-IORT. Eligibility criteria included age ≥50 years, invasive or in situ breast cancer, tumor size <3 cm, and N0 disease. Patients were eligible before or within 30 days of breast-conserving surgery (BCS). BCS was performed, and a multilumen balloon catheter was placed. CT images were obtained, a customized HDR brachytherapy plan was created, and a dose of 12.5 Gy was delivered to 1-cm depth from the balloon surface. The catheter was removed, and the skin was closed. The primary endpoints were feasibility and acute toxicity. Feasibility was defined as IORT treatment interval (time from CT acquisition until IORT completion) ≤90 minutes. The secondary endpoints included dosimetry, cosmetic outcome, quality of life, and late toxicity. Results: Twenty-eight patients were enrolled. The 6-month follow-up assessments were completed by 93% of enrollees. The median IORT treatment interval was 67.2 minutes (range, 50-108 minutes). The treatment met feasibility criteria in 26 women (93%). The dosimetric goals were met in 22 patients (79%). There were no Radiation Therapy Oncology Group grade 3+ toxicities; 6 patients (21%) experienced grade 2 events. Most patients (93%) had good/excellent cosmetic outcomes at the last follow-up visit. Conclusions: CT-HDR-IORT is feasible and safe. This promising approach for a conformal, image-based, higher-dose breast IORT is being evaluated in a phase 2 trial.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

On numerical errors to the fields surrounding a relativistically moving particle in PIC codes

The particle-in-cell (PIC) method is widely used to model the self-consistent interaction between discrete particles and electromagnetic fields. It has been successfully applied to problems across plasma physics including plasma based acceleration, inertial confinement fusion, magnetically confined fusion, space physics, astrophysics, high energy density plasmas. In many cases the physics involves how relativistic particles (those with high relativistic γ factors) are generated and interact with plasmas. However, when relativistic particles stream across the grid, both in “vacuum” and in plasma, many numerical issues may arise which can lead to unphysical results. We present a detailed analysis of how discretized Maxwell solvers used in PIC codes can lead to numerical errors to the fields that surround particles that move at relativistic speeds across the grid. Expressions for the axial electric field as integrals in k space are presented that reveal two types of errors. The first arises from errors to the numerator of the integrand and leads to unphysical fields that are antisymmetric about the particle. Furthermore, the second arises from errors to the denominator of the integrand and lead to Cherenkov like radiation in “vacuum”. These fields are not anti-symmetric, extend behind the particle, and cause the particle to accelerate or decelerate depending on the solver and parameters. The unphysical fields are studied in detail for two representative solvers - the Yee solver and the FFT based solver. Although the Cherenkov fields are absent, the space charge fields are still present in the fundamental Brillouin zone for the FFT based solvers. In addition, the Cherenkov fields are present in higher order zones for the FFT based solvers. Comparison between the analytical solutions and PIC simulation results are presented. A solution for eliminating these unphysical fields by modifying the k operator in the axial direction is also presented. Using a customized finite difference solver, this solution was successfully implemented into OSIRIS [1]. Results from the customized solver are also presented. Additionally, this solution will be useful for a beam of particles that all move in one direction with a small angular divergence.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Review of in situ process monitoring for metal hybrid directed energy deposition

Hybrid manufacturing, or the combination of additive and subtractive manufacturing within a single build volume is transforming the way products are being fabricated. Additive manufacturing confers unprecedented freedom of design and reduced material usage while enabling serial customization. Subtractive manufacturing provides superior surface finish and improved dimensional accuracies. Interwoven, these two digital manufacturing paradigms are enabling the rapid manufacturing of complex, highly accurate, and customized geometries in a diversity of high-performance alloys. In situ monitoring, heavily relied upon in either additive or subtractive, becomes even more crucial with the interplay of the two processes in a single combined build sequence. Moreover, challenges that do not exist in either process alone can now have a dramatic impact on final part quality: (1) a large amount of heat is generated during additive manufacturing deposition, which is primarily dissipated into the machine tooling and impacts accuracy by deforming the material and causing misaligned machining; (2) microstructure, mechanical properties, and residual stresses are the result of the complex thermal histories generated by additive manufacturing and can impact subsequent cutting performance. This comprehensive review considers previous research in monitoring and providing closed-loop control in both additive and subtractive manufacturing separately and then considers the implications of the effectiveness of these monitoring techniques when additive and subtractive processes are integrated together.

36 MATERIALS SCIENCE↗

Immobilization and image-guidance methods for radiation therapy of limb extremity soft tissue sarcomas: Results of a multi-institutional survey

Radiation therapy for limb-extremity soft tissue sarcoma (STS) requires accurate, reproducible dose delivery. However, patient positioning is challenging and there is a lack of existing guidelines to assist institutional standardization. Therefore, we conducted a multi-institutional international survey of STS immobilization, image guidance methods, and treatment protocols to investigate current practice. Seventy-three UK radiotherapy centers and 15 hospitals in 7 other countries completed a questionnaire on STS immobilization and image-guidance procedures. Specifically, the survey collated information on the current usage of immobilization equipment, including custom devices, patient setup tolerances, the use of written protocols, the modality and frequency of image guidance, the method of treatment, allocated treatment times, and the application of surgical clips. Multiple combinations of immobilization devices were reported. In the UK, 12%, 40%, 30%, 12%, and 5% use 1, 2, 3, 4, and 5 types of device for lower limb STS. Vacuum bag plus either foot or ankle support was most common (66%). Of 15 international centers, 27%, 60%, 7%, 0%, 7% use 1, 2, 3, 4, 5 devices, with vacuum bags (73%) and thermoplastic (47%) predominant, similar to UK values of 77% and 52%. For image guidance, in the UK, 37% use kV planar, 34% use MV planar, and 16% use cone-beam CT for the first 3 fractions and then weekly. Internationally, daily imaging was more prevalent with 33% using kV planar, 7% MV planar, and 40% cone-beam CT daily. Custom devices plus combinations of devices, along with 5- and 10-mm set-up tolerances, were most commonly reported. Less than half of centers have written treatment protocols. Conventional treatment is most common in the UK, with only 42% using conformal techniques. Treatment is allocated between 10 and 30 minutes. Twenty-six percent of UK centers and 53% of international centers use surgical clips. Across treatment centers, there is no consistent approach to STS immobilization, image-guidance methods, or treatment protocols assessed by this survey. A wide variety of immobilization devices and configurations are utilized, and the frequency and modality of imaging are similarly diverse. In the absence of guidelines, the creation of an online repository of example immobilization techniques could enable centers to compare a diversity of cases. The availability of a forum for viewing and discussing a range of cases could potentially lead to improved patient setup and reduce the time taken to devise an individual immobilization strategy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Stable electrospray signal on a microfabricated glass chip with three-dimensional open edge and tiered depth geometries

This paper presents the microfabrication and performance of a three-dimensional electrospray ionization (ESI) emitter tip made from glass, which achieves stable current signals important for chemical analysis. Our novel microfabrication process and custom-built signal conditioning hardware provides the advantage of providing accurate features and steady signals. The fabrication process relies on standard microfabrication techniques (i.e., deposition, photolithography, and wet etching). This fabrication method involves the novel application of two layers of positive and negative photoresists in addition to Parafilm® wax tape. Open edge and tiered depth details were successfully created from a multilayer planar mask. This is a benefit for integrated miniaturized and microfluidic systems that often require micro features for their functionality but relatively large millimeter size features for their physical periphery. We demonstrate the fundamental performance of electrospray with this microfluidic chip. The emitter tip was fixed on a linear axis stage with high resolution (10 μm) to finely control the tip distance from a metal counter electrode plate. Further, a custom printed circuit board system was built to safely control four voltages applied to the microchip ports from a single high voltage power supply. To readily form the electrospray, non-aqueous solvents were used for their low viscosity and a constant voltage of +2.7 kV was applied to the sheath electrospray microchannel. The liquid being sprayed was 80/20 (v/v) methanol/acetonitrile with 0.1% acetic acid in the sheath microchannel and with ammonium acetate (10–40 mM) in its remaining microchannels. The electrospray signal was measured in response to varying the distance (1.4 to 1.6mm) between the electrospray emitter tip and a metal counter electrode plate in addition to the varying concentration of the background electrolyte, ammonium acetate. Stable and repeatable electrospray signal showed linear relationships with emitter tip distance and concentration (r 2 ≥ 0.95).

42 ENGINEERING↗

An automated multiplexed turbidometric and data collection system for measuring growth kinetics of anaerobes dependent on gaseous substrates

Standard methods of monitoring the growth kinetics of anaerobic microorganisms are generally impractical when there is a protracted or indeterminate period of active growth, and when high numbers of samples or replications are required. As part of our studies of the adaptive evolution of a simple anaerobic syntrophic mutualism, requiring the characterization of many isolates and alternative syntrophic pairings, here we developed a multiplexed growth monitoring system using a combination of commercially available electronics and custom designed circuitry and materials. This system automatically monitors up to 64 sealed, and as needed pressurized, culture tubes and reports the growth data in real-time through integration with a customized relational database. The utility of this system was demonstrated by resolving minor differences in growth kinetics associated with the adaptive evolution of a simple microbial community comprised of a sulfate reducing bacterium, Desulfovibrio vulgaris, grown in syntrophic association with Methanococcus maripaludis, a hydrogenotrophic methanogen.

59 BASIC BIOLOGICAL SCIENCES↗

Livermore tomography tools: Accurate, fast, and flexible software for tomographic science

Livermore Tomography Tools (LTT) is a customizable scientific software package that enables a broad range of research and development efforts into computed tomography (CT). Here, it was developed to process x-ray and neutron CT data accurately and rapidly from raw detector counts to reconstructed volumes with the flexibility to handle many special cases. LTT fulfills long-term CT software goals to provide quantitatively accurate results reported in physical units (e.g., mm -1 or cm -1 ) while exploiting all available computational advantages to maximize speed. Written in C/C++ with support for multiple CPUs and GPUs, LTT runs on many computing platforms (Linux/Unix, Windows, and Mac; laptops to supercomputers). As a result, LTT can:process data acquired from various custom-built and commercially available CT scanners, model and simulate x-ray and neutron interactions to encourage algorithm prototyping, and allow for rapid insertion of the latest algorithms.We describe LTT’s software architecture, user interfaces, and its 88 algorithms (as of this writing) for pre-processing, reconstruction, post-processing, and simulation that support many scanner geometries (parallel-, fan-, cone-beam, and custom). Several applications are presented that illustrate LTT’s accuracy, speed, and flexibility relative to other solutions.

36 MATERIALS SCIENCE↗

Focal-plane detector system for the KATRIN experiment

Here, the local plane detector system for the KArlsiuhe TRItium Neutrino (KATRIN) experiment consists of a multi-pixel silicon p-i-n-diode array, custom readout electronics, two superconducting solenoid magnets, an ultra high vacuum system, a high vacuum system, calibration and monitoring devices, a scintillating veto, and a custom data-acquisition system, It is designed to detect the low-energy electrons selected by the KATRIN main spectrometer. We describe the system and summarize its performance after its final installation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Q weak experimental apparatus

The Jefferson Lab Q weak experiment determined the weak charge of the proton by measuring the parity-violating elastic scattering asymmetry of longitudinally polarized electrons from an unpolarized liquid hydrogen target at small momentum transfer. A custom apparatus was created for this experiment to meet the technical challenges presented by the smallest and most precise e → p asymmetry ever measured. Technical milestones were achieved at Jefferson Lab in target power, beam current, beam helicity reversal rate, polarimetry, detected rates, and control of helicity-correlated beam properties. The experiment employed 180 μA of 89% longitudinally polarized electrons whose helicity was reversed 960 times per second. The electrons were accelerated to 1.16 GeV and directed to a beamline with extensive instrumentation to measure helicity-correlated beam properties that can induce false asymmetries. Møller and Compton polarimetry were used to measure the electron beam polarization to better than 1%. The electron beam was incident on a 34.4 cm liquid hydrogen target. After passing through a triple collimator system, scattered electrons between 5.8° and 11.6° were bent in the toroidal magnetic field of a resistive copper-coil magnet. The electrons inside this acceptance were focused onto eight fused silica Cherenkov detectors arrayed symmetrically around the beam axis. A total scattered electron rate of about 7 GHz was incident on the detector array. The detectors were read out in integrating mode by custom-built low-noise pre-amplifiers and 18-bit sampling ADC modules. The momentum transfer Q 2 =0.025 GeV 2 was observed using dedicated low-current ( ~ 100 pA ) measurements with a set of drift chambers before (and a set of drift chambers and trigger scintillation counters after) the toroidal magnet

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mass production of a trigger data serializer ASIC for the upgrade of the muon spectrometer at the ATLAS experiment

The Trigger Data Serializer (TDS) is a custom ASIC designed for the upgrade of the innermost station of the endcap ATLAS Muon spectrometer. Here, it is a mixed-signal chip with two working modes that can handle up to 128 detector channels. A total of 6000 TDS ASICs have been produced for detector operation. This paper discusses a custom automatic test platform we developed to provide quality control of the TDS ASICs. We introduce the design, illustrate the test procedures, and discuss the experimental results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation and mitigation of trace 210Pb contamination on copper surfaces

Clean materials are required to construct and operate many low-background physics experiments. High-purity copper has found broad use because of its physical properties and availability. In this paper, we describe methods to assay and mitigate Pb-210 contamination on copper surfaces, such as from exposure to environmental radon or coming from bulk impurities. We evaluated the efficacy of wet etching on commercial samples and observed that Po-210 contamination from the copper bulk does not readily pass into solution. During the etch, the polonium appears to trap at the copper-etchant boundary, such that it is effectively concentrated at the copper surface. We observed a different behavior for Pb-210; high-sensitivity measurements of the alpha emissivity versus time indicate the lowest level of Pb-210 contamination ever reported for a commercial copper surface: 0 +/- 12 nBq/cm2 (1-sigma). Additionally, we have demonstrated the effectiveness of mitigating trace Pb-210 and Po-210 surface backgrounds using custom, high-purity electroplating techniques. These approaches were evaluated utilizing assays performed with an XIA UltraLo-1800 alpha spectrometer.

radon, copper, copper cleaning, dark matter, Pb-21↗

The fixed probe storage ring magnetometer for the Muon g-2 experiment at Fermi National Accelerator Laboratory

The goal of the FNAL E989 experiment is to measure the muon magnetic anomaly to unprecedented accuracy and precision at the Fermi National Accelerator Laboratory. To meet this goal, the time and space averaged magnetic environment in the muon storage volume must be known to better than 70 ppb. A new pulsed proton nuclear magnetic resonance (NMR) magnetometer was designed and built at the University of Washington, Seattle to track the temporal stability of the 1.45 T magnetic field in the muon storage ring at this precision. It consists of an array of 378 petroleum jelly based NMR probes that are embedded in the walls of muon storage ring vacuum chambers and custom electronics built with readily available modular radio frequency (RF) components. We give NMR probe construction details and describe the functions of the custom electronic subsystems. The excellent performance metrics of the magnetometer are discussed, where after 8 years of operation the median single shot resolution of the array of probes remains at 650 ppb.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pixelated plastic scintillator array manufacturing using fast-, photo-curable resin

Pixelated plastic scintillator arrays can serve as high efficiency and high resolution neutron imaging detectors. Manufacturing these arrays is intensive in both time and labor. This article presents a fabrication method based on additive manufacturing for two-dimensional plastic organic scintillator arrays using a custom-built automated assembly machine and a custom photocurable resin that has significant non-aromatic acrylate oligomer content. The process involves two main stages: fully autonomous production of one-dimensional layered arrays, followed by semi-autonomous cutting and stacking to form two-dimensional pixel arrays. One-dimensional arrays were manufactured at a rate of around 4 layers per hour with minimal defects and tight dimensional tolerances, while two-dimensional arrays up to 7 x 7 pixels and 70 mm in length were completed in approximately 3.5 hours. Final arrays exhibited dimensional deviations of less than 0.5 mm. Two-dimensional arrays read out by a multi-anode photomultiplier tube demonstrated per-pixel position resolution and pulse-shape discrimination, enabling gamma–neutron interaction separation in mixed radiation environments.

36 MATERIALS SCIENCE↗