Crossover Flux and Ionic Resistance Metrics in Polysulfide-Permanganate Redox Flow Battery Membranes

A survey of 23 commercially available cation exchange membranes was performed for the downselection of membranes for use in a polysulfide-permanganate redox flow battery (pS-Mn RFB). The survey measured the flux of permanganate ions across a 0.1 mol L −1 concentration gradient as well as the membrane resistance in a 0.5 mol L −1 sodium chloride solution. The membranes exhibited the characteristic flux/resistance trade-off observed in most classes of membranes. To connect the individual membrane testing to how the membranes will perform in a device, cell performance data in a pS-Mn RFB was collected for three membranes from the survey. The coulombic, voltaic, and energy efficiency at low cycle counts aligned with the predictions from the membrane flux and resistance survey results. The study also identified three membranes—Fumapem F-930-RFS, Fumapem FS-715-RFS, and Aquivion E98-09S—that outperformed most other membranes regarding their position on the flux-resistance trade-off curve, indicating them to be good candidates for further testing.

Electrochemistry↗

Sensitivity and uncertainty analysis of PWR spent fuel observables to operational and model parameters

Sensitivity and uncertainty analyses of spent nuclear fuel (SNF) observables - decay heat, neutron and γ-ray emission rate - to operational and model parameters have been performed. A 2D model representing a typical PWR 17x17 UO{sub 2} fuel assembly has been taken as reference. The Serpent code and ENDF/B-VII.1 evaluated nuclear data library have been used for the analyses. Relative uncertainty of decay heat, neutron and γ-ray emission rates due to Monte Carlo counting statistics, as well as the number of fuel pin radial regions required for an accurate characterization of SNF neutron emission, have been estimated. A parametric study has been carried out to investigate the impact of the homogenization to an average value of the fuel and moderator temperature, boron concentration power and burnup on the prediction of the selected observables. In addition, linear sensitivity coefficients have been calculated. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Summary Report for the Environmental Protection Agency MERL/FRMAC Mission Alignment Exercise held at the Environmental Protection Agency Facility on June 24-26 2014

From June 24th thru June 26th 2014, members of the Federal Radiological Monitoring and Assessment Center (FRMAC), FRMAC Fly Away Laboratory, and the Environmental Protection Agency (EPA) participated in a joint nuclear incident emergency response/round robin exercise at the EPA facility in Las Vegas, Nevada. The purpose of this exercise was to strengthen the interoperability relationship between the FRMAC Fly Away Laboratory (FAL) and the EPA Mobile Environmental Radiation Laboratory (MERL) stationed in Las Vegas, Nevada. The exercise was designed to allow for immediate delivery of pre-staged, spiked samples to the EPA MERL and the FAL for sample preparation and radiological analysis. Upon completion of laboratory analysis, data was reviewed and submitted back to the FRMAC via an electronic data deliverable (EDD). In order to conduct a laboratory inter-comparison study, samples were then traded between the two laboratories and re-counted. As part of the exercise, an evaluation was conducted to identify gaps and potential areas for improvements for FRMAC, FAL and EPA operations. Additionally, noteworthy practices and potential future areas of interoperability opportunities between the FRMAC, FAL and EPA were acknowledged. The exercise also provided a unique opportunity for FRMAC personnel to observe EPA sample receipt and sample preparation processes and to gain familiarity with the MERL laboratory instrumentation and radiation detection capabilities. The areas for potential improvements and interoperability from this exercise will be critical for developing a more efficient, integrated response for future interactions between the FRMAC and EPA MERL assets.

54 ENVIRONMENTAL SCIENCES↗

Performance Evaluation of Darshan 3.0.0 on the Cray XC30

Abstract—Darshan is a lightweight I/O characterization tool used to gather and summarize salient I/O workload statistics from HPC applications. Darshan was designed to minimize any possible perturbations of an application’s performance, leading it to be enabled by default on a number of production HPC systems. For each file accessed by a given application, Darshan records the count and types of I/O operations performed, histograms of access sizes, cumulative timers on the amount of time spent doing I/O, and other statistical data. This type of data has proved invaluable in understanding and improving the I/O performance of HPC applications. Darshan 3.0.0 is the new modularized version of the traditional Darshan library and file format, allowing users to easily add more in-depth I/O characterization data to Darshan logs. In this work we perform an empirical evaluation of Darshan 3.0.0 to ensure that it continues to meet performance expectations for broad deployment. In particular, we evaluate the imposed overhead on instrumented I/O operations, time taken to shut down and generate corresponding Darshan log files, and resultant log file sizes for different workloads. These performance results are compared to results of Darshan 2.3.0 on the Edison XC30 system at NERSC to determine whether the new version is lightweight enough to run full-time on production HPC systems. Our evaluation shows that Darshan has limited impact on application I/O performance and can fully generate a corresponding log file for most application workloads in under two seconds.

97 MATHEMATICS AND COMPUTING↗

Neutron Multiplicity Counting Diagnosis of Uranium Assemblies Interrogated by Cf-252 [Poster]

Researchers concluded: First neutron multiplicity counting of tens of kilograms of 235 U with organic scintillators; leakage multiplication estimates to be improved by incorporating detector cross-talk; provides data comparison for “Multiplicity Theory Beyond the Point Model;" promotes continued use of organic scintillators for NCERC and elsewhere.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

NREL + Verizon Wireless

Verizon Wireless and the National Renewable Energy Laboratory (NREL) are working to develop and validate a new design solution for telecommunications facilities. Network equipment is all DC, so rather than relying on conventional AC power, the design will employ photovoltaics (PV) and batteries, and it will require new DC cooling systems. The new design will ease utility interconnection by connecting PV to the DC bus and batteries, increase resiliency by allowing PV to contribute - and cooling to continue - in a power outage, lower costs with day-to-day utility cost savings, and increase efficiency through reduced part count and fewer power conversions from DC to AC.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Comparison of MCNP6 and experimental results for neutron counts, Rossi-{alpha}, and Feynman-{alpha} distributions

MCNP6, the general-purpose Monte Carlo N-Particle code, has the capability to perform time-dependent calculations by tracking the time interval between successive events of the neutron random walk. In fixed-source calculations for a subcritical assembly, the zero time value is assigned at the moment the neutron is emitted by the external neutron source. The PTRAC and F8 cards of MCNP allow to tally the time when a neutron is captured by {sup 3}He(n, p) reactions in the neutron detector. From this information, it is possible to build three different time distributions: neutron counts, Rossi-{alpha}, and Feynman-{alpha}. The neutron counts time distribution represents the number of neutrons captured as a function of time. The Rossi-a distribution represents the number of neutron pairs captured as a function of the time interval between two capture events. The Feynman-a distribution represents the variance-to-mean ratio, minus one, of the neutron counts array as a function of a fixed time interval. The MCNP6 results for these three time distributions have been compared with the experimental data of the YALINA Thermal facility and have been found to be in quite good agreement. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Efficient Joins with Compressed Bitmap Indexes

We present a new class of adaptive algorithms that use compressed bitmap indexes to speed up evaluation of the range join query in relational databases. We determine the best strategy to process a join query based on a fast sub-linear time computation of the join selectivity (the ratio of the number of tuples in the result to the total number of possible tuples). In addition, we use compressed bitmaps to represent the join output compactly: the space requirement for storing the tuples representing the join of two relations is asymptotically bounded by min(h; n . cb), where h is the number of tuple pairs in the result relation, n is the number of tuples in the smaller of the two relations, and cb is the cardinality of the larger column being joined. We present a theoretical analysis of our algorithms, as well as experimental results on large-scale synthetic and real data sets. Our implementations are efficient, and consistently outperform well-known approaches for a range of join selectivity factors. For instance, our count-only algorithm is up to three orders of magnitude faster than the sort-merge approach, and our best bitmap index-based algorithm is 1.2x-80x faster than the sort-merge algorithm, for various query instances. We achieve these speedups by exploiting several inherent performance advantages of compressed bitmap indexes for join processing: an implicit partitioning of the attributes, space-efficiency, and tolerance of high-cardinality relations.

97 MATHEMATICS AND COMPUTING↗

Long-range time-of-flight scanning sensor based on high-speed time-correlated single-photon counting

We describe a scanning time-of-flight system which uses the time-correlated single-photon counting technique to produce three-dimensional depth images of distant, noncooperative surfaces when these targets are illuminated by a kHz to MHz repetition rate pulsed laser source. The data for the scene are acquired using a scanning optical system and an individual single-photon detector. Depth images have been successfully acquired with centimeter xyz resolution, in daylight conditions, for low-signature targets in field trials at distances of up to 325 m using an output illumination with an average optical power of less than 50 {mu}W.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Uncertainty Quantification of Spatial Correction Factor for Sjoestrand Method due to Cross-section Data

Accelerator-driven System (ADS), which couples a subcritical core with a spallation neutron source, is proposed as a nuclear transmutation technology to reduce the radioactive half-life of high-level waste. To maintain a safe operation in ADS, the core should be kept in subcritical state. Thus, the subcritical state of the core must be quantified through measurement of subcriticality, which is a quantitative margin from critical state. The area ratio method, or the Sjoestrand method, is one of the subcriticality measurement techniques applicable to the ADS. In this method, the absolute value of subcriticality can be obtained by analyzing the temporal variation of neutron density in the core due to the periodic injection of neutron pulses. In practice, the value of subcriticality is measured by the temporal variation of neutron count rate detected by a detector in the core. Time integrals of count rates due to prompt and delayed neutrons A{sub p} and A{sub d}, are measured. Then, the ratio of A{sub p} to A{sub d}, which is called as the area ratio, yields negative reactivity -ρ, i.e. subcriticality, in dollar units: A{sub p}/A{sub d} ≅ -ρ/β{sub eff'} (1) where β{sub eff} is the effective delayed neutron fraction. Equation (1) represents the basic idea of the Sjoestrand method. Note, however, that Eq. (1) is approximately derived using the point kinetics model. In an actual subcritical system, the measured area ratio is not necessarily equal to the exact value of subcriticality in dollar units, due distortion by spatial higher-order modes. Hence, in the actual measurement, this spatial effect is corrected by a spatial correction factor such as the Bell and Glasstone correction factor (the Bell factor), or by extraction of the fundamental mode (so-called the extrapolated area ratio method). In addition, there is an effect due to the neutron detector materials (e.g. {sup 3}He(n,p) and {sup 235}U(n,f)). These effects must be considered in the correction of the measured area ratio. In this study, we focused on the uncertainty of Bell factor. The Bell factor f is defined by the ratio of the area ratio to the subcriticality as follows: f ≡ -[ρ/β{sub eff}]/[A{sub p}/A{sub d}] (2) The Bell factor f can be evaluated by a core analysis. By multiplying the measured area ratio by the Bell factor?, the spatial higher-order mode effect in the area ratio can be corrected. However, the uncertainty of the Bell factor due to uncertainties of cross-section data (covariance data) has not been quantitatively evaluated so far. In this study, we propose a method to quantify the uncertainty of the Bell factor in an actual core analysis. As a feasibility study, the uncertainty quantification is carried out in a simple one-dimensional subcritical core system. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Hubble Space Telescope observations of the NUV transit of WASP-12b

We present new observations of four closely spaced near-ultraviolet (NUV) transits of the hot Jupiter-like exoplanet WASP-12b using Hubble Space Telescope (HST)/Cosmic Origins Spectrograph (COS), significantly increasing the phase resolution of the observed NUV light curve relative to previous observations, while minimizing the temporal variation of the system. We observe significant excess NUV absorption during the transit, with mean normalized in-transit fluxes of F{sub norm}≃0.97, i.e., ≃2–5σ deeper than the optical transit level of ≃0.986 for a uniform stellar disk (the exact confidence level depending on the normalization method used). We further observe an asymmetric transit shape, such that the post-conjunction fluxes are overall ≃2–3σ higher than pre-conjunction values, and characterized by rapid variations in count rate between the pre-conjunction and out-of-transit levels. We do not find evidence for an early ingress to the NUV transit as suggested by earlier HST observations. However, we show that the NUV count rate observed prior to the optical transit is highly variable, but overall ≃2.2–3.0σ below the post-transit values and comparable in depth to the optical transit, possibly forming a variable region of NUV absorption from at least phase ϕ≃0.83, limited by the data coverage.

79 ASTRONOMY AND ASTROPHYSICS↗

Cross sections of the {sup 67}Zn(n,{alpha}){sup 64}Ni reaction at 4.0, 5.0, and 6.0 MeV

Experimental cross section data of the {sup 67}Zn(n,{alpha}){sup 64}Ni reaction are very scanty because the residual nucleus {sup 64}Ni is stable and the commonly used activation method is not feasible. As a result, very large deviations (about 10 times) exist among different nuclear data libraries. In the present work, cross sections of the partial {sup 67}Zn(n,{alpha}{sub 0}){sup 64}Ni and total {sup 67}Zn(n,{alpha}){sup 64}Ni reactions are measured at neutron energies of 4.0 and 5.0 MeV for the first time, and those of 6.0 MeV are remeasured for consistency checking. A twin-gridded ionization chamber was used as the charged-particle detector and two enriched back-to-back-set {sup 67}Zn samples were adopted. Experiments were performed at the 4.5 MV Van de Graaff Accelerator of Peking University. Neutrons were produced through the {sup 2}H(d,n){sup 3}He reaction using a deuterium gas target. Absolute neutron flux was determined by counting the fission fragments from a {sup 238}U sample placed inside the gridded ionization chamber while a BF{sub 3} long counter was employed as neutron flux monitor. Present data are compared with results of previous measurements, evaluations, and talys code calculations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Prismatic analyser concept for neutron spectrometers

Developments in modern neutron spectroscopy have led to typical sample sizes decreasing from few cm to several mm in diameter samples. We demonstrate how small samples together with the right choice of analyser and detector components makes distance collimation an important concept in crystal analyser spectrometers. We further show that this opens new possibilities where neutrons with different energies are reflected by the same analyser but counted in different detectors, thus improving both energy resolution and total count rate compared to conventional spectrometers. The technique can readily be combined with advanced focussing geometries and with multiplexing instrument designs. We present a combination of simulations and data showing three different energies simultaneously reflected from one analyser. Experiments were performed on a cold triple axis instrument and on a prototype inverse geometry Time-of-flight spectrometer installed at PSI, Switzerland, and shows excellent agreement with the predictions. Typical improvements will be 2.0 times finer resolution and a factor of 1.9 in flux gain compared to a focussing Rowland geometry, or of 3.3 times finer resolution and a factor of 2.4 in flux gain compared to a single flat analyser slab.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Choline supplementation alleviates fluoride-induced testicular toxicity by restoring the NGF and MEK expression in mice

Fluoride is known to cause male reproductive toxicity, and the elucidation of its underlying mechanisms is an ongoing research focus in reproductive toxicology and epidemiology. Choline, an essential nutrient, has been extensively studied for its benefits in nervous system yet was rarely discussed for its prospective effect in male reproductive system. This study aims to explore the potential protective role of choline against NaF-induced male reproductive toxicity via MAPK pathway. The male mice were administrated by 150 mg/L NaF in drinking water, 5.75 g/kg choline in diet, and their combination respectively from maternal gestation to postnatal 15 weeks. The results showed that fluoride exposure reduced body weight growth, lowered sperm count and survival percentages, altered testicular histology, down-regulated the mRNA expressions of NGF, Ras, Raf, and MEK genes in testes, as well as significantly decreased the expressions of both NGF and phosphor-MEK proteins in testes. Examination of data from choline-treated mice revealed that choline supplementation ameliorated these fluoride-induced changes. Taken together, our findings suggest that choline supplementation alleviates fluoride-induced testicular toxicity by restoring the NGF and phosphor-MEK expression. The suitable dosage and supplementation periods of choline await further exploration. - Highlights: • Fluoride exposure altered the growth and development, sperm count and sperm survival percentages, testicular histology • Fluoride exposure decreased NGF, Ras, and Mek mRNA and NGF and p-MEK protein expressions in testis of mice. • Choline supplementation diminishes fluoride-induced testicular toxicity.

54 ENVIRONMENTAL SCIENCES↗

The missing GeV γ-ray binary: Searching for HESS J0632+057 with Fermi -LAT

The very high energy (VHE; >100 GeV) source HESS J0632+057 has been recently confirmed as a γ-ray binary, a subclass of the high-mass X-ray binary population, through the detection of an orbital period of 321 d. We performed a deep search for the emission of HESS J0632+057 in the GeV energy range using data from the Fermi Large Area Telescope (LAT). The analysis was challenging due to the source being located in close proximity to the bright γ-ray pulsar PSR J0633+0632 and lying in a crowded region of the Galactic plane where there is prominent diffuse emission. We formulated a Bayesian block algorithm adapted to work with weighted photon counts, in order to define the off-pulse phases of PSR J0633+0632. A detailed spectral-spatial model of a 5° circular region centred on the known location of HESS J0632+057 was generated to accurately model the LAT data. No significant emission from the location of HESS J0632+057 was detected in the 0.1–100 GeV energy range integrating over ~3.5 yr of data, with a 95 per cent flux upper limit of F0.1-100 GeV < 3 × 10 –8 ph cm –2 s –1 . A search for emission over different phases of the orbit also yielded no significant detection. A search for source emission on shorter time-scales (days–months) did not yield any significant detections. We also report the results of a search for radio pulsations using the 100-m Green Bank Telescope. No periodic signals or individual dispersed bursts of a likely astronomical origin were detected. We estimated the flux density limit of < 90/40 μJy at 2/9 GHz. Furthermore, the LAT flux upper limits combined with the detection of HESS J0632+057 in the 136–400 TeV energy band by the MAGIC collaboration imply that the VHE spectrum must turn over at energies <136 GeV placing constraints on any theoretical models invoked to explain the γ-ray emission.

79 ASTRONOMY AND ASTROPHYSICS↗

ThermoPore: Predicting part porosity based on thermal images using deep learning

Part qualification is often a critical and labor-intensive process in additive manufacturing, particularly in the detection of defects such as porosity, which stands to benefit significantly from advancements in machine learning. We present a deep learning approach for quantifying and localizing ex-situ porosity within Laser Powder Bed Fusion fabricated samples utilizing in-situ thermal image monitoring data. Our goal is to build the real time porosity map of parts based on thermal images acquired during the build. The quantification task builds upon the established Convolutional Neural Network model architecture to predict pore count and the localization task leverages the spatial and temporal attention mechanisms of the novel Video Vision Transformer model to indicate areas of expected porosity. Our model for porosity quantification achieved a R 2 score of 0.57 and our model for porosity localization produced an average Intersection over Union (IoU) score of 0.32 and a maximum of 1.0. This work is setting the foundations of part porosity “Digital Twins” based on additive manufacturing monitoring data and can be applied downstream to reduce time-intensive post-inspection and testing activities during part qualification and certification. In addition, we seek to accelerate the acquisition of crucial insights normally only available through ex-situ part evaluation by means of machine learning analysis of in-situ process monitoring data.

Deep learning↗

A Robot for Nondestructive Assay of Holdup Deposits in Gaseous Diffusion Piping - 19504

Miles of contaminated pipe must be characterized as part of the decommissioning effort at deactivated gaseous diffusion enrichment facilities. The current method requires cutting away asbestos- lined thermal enclosures and performing repeated, elevated operations to manually perform nondestructive assay (NDA) on pipe from the outside. The RadPiper robot, part of the Pipe Crawling Activity Measurement System (PCAMS) developed by Carnegie Mellon University and commissioned for use at the DOE Portsmouth Gaseous Diffusion Enrichment Facility, automatically measures U-235 in pipes from the inside. This improves certainty, increases safety, and greatly reduces measurement time. The heart of the RadPiper robot is a sodium iodide scintillation detector in an innovative disc-collimated assembly. By measuring from inside pipes, the robot significantly increases its count rate relative to external through-pipe measurements. The robot also provides imagery, models interior pipe geometry, and precisely measures distance in order to localize radiation measurements. Data collected by this system provides insight into pipe interiors that is simply not possible from exterior measurements, all while keeping operators safer. This paper describes the technical details of the PCAMS RadPiper robot. Key features for this robot include precision distance measurement, in-pipe obstacle detection, ability to transform for two pipe sizes, and robustness in autonomous operation. Test results demonstrating the robot's functionality are presented, including deployment tolerance tests, safeguarding tests, and localization tests. Integrated robot tests are also shown. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Waste Characterization Methods Based on Gamma-ray Imaging Spectrometers - 19454

Characterization of LLW, ILW, U, NORM and TENORM is critical to the nuclear industry's bottom line. Accurate measurements enable the disposal of waste at the lowest possible cost. In the past the most accurate technology available involved using HPGe detectors and extensive system modeling to estimate the total source term given what the user knows about the geometry of the source and any shielding between the source and the detectors. Now there are a variety of imaging detectors that are available commercially, including CZT and HPGe detectors that achieve energy resolution ≤1% FWHM at 662 keV. These devices couple the traditional high resolution spectroscopic analysis with next generation gamma-ray imaging information to more accurately characterize the radiation source term. Uncertainties in the source location will result in significant error in the characterization of an object's radioactivity. It is helpful if the object can be spun, such as a barrel, so that any asymmetry in the source distribution is averaged out from the detector's point of view. Even in the case of a spinning barrel it is important to determine if the radiation is concentrated near the center of the barrel or distributed near the edge. The closer one measures to a barrel, which usually dictates the time required to acquire data, the more these spatial variations in the source distribution will affect the calculated activity of each isotope. This paper will focus on showing the use of CZT imaging spectrometers to characterize complicated radiation source terms. The radiation images are used to determine where the source term should be defined in a radiation transport model that calculates the expected number of photopeak counts for each isotope detected. This is used to calculate the activity of the source. The transport model is used to determine the attenuation of the radiation source term through distance and shielding material, but the detection efficiency is based solely on radiation measurement data. These measurements are taken with a robotic source positioning device that allows for detailed directional efficiency calibration. It is a fully automated system where a detector is loaded into the device and all of the efficiency curves are captured as a function of direction by creating new measurements for each location the robot positions the source. These measurements are tagged with the true source location and the efficiency curve is calculated for each measurement. This is used to create a response function matrix as a function of energy and incident direction which is used to convert the direction dependent flux on the detector head determined from the simulation model to the expected number of counts per unit activity of each isotope of interest. The results of these source term reconstructions in both the spatial and spectral domain will be shown. The impact of improper specification of the source term will be shown for a few standard waste characterization scenarios to demonstrate the importance of proper source location determination. Finally, the underlying calibration method and some sample efficiency curves as a function of direction will be shown to demonstrate the importance of calibrating out directional response functions in imaging devices (which often have a strong forward sensitivity bias). (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗