Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “charge”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

"Electrostructural Phase Changes" In Charged Particulate Clouds: Planetary and Astrophysical Implications

There is empirical evidence that freely-suspended triboelectrostatically charged particulate clouds of dielectric materials undergo rapid conversion from (nominally) monodispersed "aerosols" to a system of well-defined grain aggregates after grain motion or fluid turbulence ceases within the cloud. In United States Microgravity Laboratory Space Shuttle experiments USML-1 and USML-2, it was found that ballistically-energized grain dispersions would rapidly convert into populations of filamentary aggregates after natural fluid (air) damping of grain motion. Unless continuously disrupted mechanically, it was impossible to maintain a non-aggregated state for the grain clouds of sand-size materials. Similarly, ground- based experiments with very fine dust-size material produced the same results: rapid, impulsive "collapse" of the dispersed grains into well-defined filamentary structures. In both ground-based and microgravity experiments, the chains or filaments were created by long-range dipole electrostatic forces and dipole-induced dielectric interactions, not by monopole interactions. Maintenance of the structures was assisted by short-range static boundary adhesion forces and van der Waals interactions. When the aggregate containers in the USML experiments were disturbed after aggregate formation, the quiescently disposed filaments would rearrange themselves into fractal bundles and tighter clusters as a result of enforced encounters with one another. The long-range dipole interactions that bring the grains together into aggregates are a product of randomly-distributed monopole charges on the grain surfaces. In computer simulations, it has been shown that when the force vectors of all the random charges (of both sign) on a grain are resolved mathematically by assuming Coulombic interaction between them, the net result is a dipole moment on individual grains, even though the grains are electrically neutral insofar as there is no predominance, on their surface, of one charge sign over another. The random charges of both sign derive from natural grain-to-grain interactions that produce triboelectrification via charge exchange every time grain surfaces make contact with one another. The conversion from a random distribution of grains (upon which there are randomly distributed charges) into an organization of electrostatically-ordered aggregates, can be regarded (within the framework of granular-material science) as an "electrical or Coulombic phase change" of the particulate cloud. It is not totally dissimilar from the more normal phase-change concept in which, for example, a gas with long free-path-molecules suddenly becomes a solid as a result of structural ordering of the molecules (notably, also the result of electronic forces, albeit at a different scale). In both the gas-to-solid case, and the aerosol-to-aggregate case, the same materials and charges are present before and after the phase change, but their arrangement now has a higher degree of order and a lower-energy configuration. An input of energy into the system is required to reverse the situation. The aggregates in the USML experiments were observed to undergo at least two phase changes as noted above. The point about phase changes, and by implication, the "electrostructural" reorganizations in particulate clouds, is the following: (a) they can occur very rapidly, almost spontaneously, above a critical cloud density, (b) in going from a higher energy state to a lower energy state, they convert to a denser system, (c) energy must be required to reverse the situation, implying that energy is released during the high-to-low energy phase change. In applying this information to natural particulate clouds, some inferences can be made (it is stressed that reference is still to dielectric materials attracted by dipole forces). There are several natural settings to which the USML observations apply, and to which the phase-change implications likewise apply. Dense clouds of triboelectrically-charged, kinetically-energized grains are to be found in volcanic eruptions (particularly on earth), aeolian dust storms (particularly on Mars), meteorite impact ejecta curtains (on all planets), in "immature" debris rings around planets (e.g., that from which our own Moon may have condensed), and in gravitationally collapsing protoplanetary dust/planetesimal debris disks where dielectric granules are being increasingly brought into collisional relationships with one another (increasing both charge exchange and physical proximity). It is noted that in many of these cases, the degree of electrical charging on the grains is likely to be much higher than that in the USML experiments where charging was not enhanced above the "normal", naturally encountered level for the particular materials (quartz, glass, and various silicate minerals). Application of the phase-change concept suggests that volcanic, aeolian, and impact debris clouds may, under certain circumstances, undergo rapid, impulsive, or even catastrophic collapse into a denser state that will lead to rapid precipitation or fall-out of suspended particulates. Although this idea has been suggested previously by the author , the phase change concept possibly permits some new insights into cloud-system behavior. For example, in a protoplanetary debris disk, the work of gravity may suddenly be enhanced by electrostatically driven collapse of the system when materials reach a critical intergranular spacing or grain number density. This might reduce the rate of planet formation by orders of magnitude (considering the ratio of g-forces to electrostatic ones for very small grains in close proximity), and indeed, it might drive the collapse into a system configuration that would perhaps not be created by gravity alone. Additional information is contained in the original.

Marshall, J. R.↗

Assessment and Control of Spacecraft Charging Risks on the International Space Station

The International Space Station (ISS) operates in the F2 region of Earth's ionosphere, orbiting at altitudes ranging from 350 to 450 km at an inclination of 51.6 degrees. The relatively dense, cool F2 ionospheric plasma suppresses surface charging processes much of the time, and the flux of relativistic electrons is low enough to preclude deep dielectric charging processes. The most important spacecraft charging processes in the ISS orbital environment are: 1) ISS electrical power system interactions with the F2 plasma, 2) magnetic induction processes resulting from flight through the geomagnetic field and, 3) charging processes that result from interaction with auroral electrons at high latitude. Recently, the continuing review and evaluation of putative ISS charging hazards required by the ISS Program Office revealed that ISS charging could produce an electrical shock hazard to the ISS crew during extravehicular activity (EVA). ISS charging risks are being evaluated in an ongoing measurement and analysis campaign. The results of ISS charging measurements are combined with a recently developed model of ISS charging (the Plasma Interaction Model) and an exhaustive analysis of historical ionospheric variability data (ISS Ionospheric Specification) to evaluate ISS charging risks using Probabilistic Risk Assessment (PRA) methods. The PRA combines estimates of the frequency of occurrence and severity of the charging hazards with estimates of the reliability of various hazard controls systems, as required by NASA s safety and risk management programs, to enable design and selection of a hazard control approach that minimizes overall programmatic and personnel risk. The PRA provides a quantitative methodology for incorporating the results of the ISS charging measurement and analysis campaigns into the necessary hazard reports, EVA procedures, and ISS flight rules required for operating ISS in a safe and productive manner.

Koontz, Steve↗

Spacecraft Charging Analysis of a CubeSat

Spacecraft charging occurs when charged particles from the surrounding space plasma environment contact a spacecraft and unequal charging currents result in a net charge density accumulation on or in spacecraft materials. Charging becomes a threat when differential potentials between two points on the spacecraft or between the spacecraft and the ambient space environment build to the level that electric fields associated with the potentials exceed the electric breakdown strength of the spacecraft materials and electrostatic discharge arcs are generated. Electrostatic discharges resulting from spacecraft charging can adversely affect telemetry and cause irreparable damage to electronics. Other spacecraft charging effects include damage of solar arrays and thermal protection, enhancement of contamination of surfaces, and degradation of optics. Typically, the large government and commercial space programs include spacecraft charging analysis as part of the design process. CubeSat projects, however, usually do not have the time or funding to include a spacecraft charging analysis due to their low budget and quick-turnaround requirements. CubeSat projects also tend to rely heavily on commercial "off-the-shelf" products, many of which are not qualified for use in space, and are particularly vulnerable to the effects of the space environment. As the demand for longer and more complex CubeSat missions increases, it is becoming more and more important to consider the effects of spacecraft charging in the design process. Results of surface charging analysis using Nascap-2k on a typical CubeSat design for a polar orbit scenario are illustrated. These results show that for a polar orbiting CubeSat, spacecraft charging could be an issue and steps should be taken to mitigate the effects for these small satellites.

Willis, Emily M.↗

Measuring momentum for charged particle tomography

Methods, apparatus and systems for detecting charged particles and obtaining tomography of a volume by measuring charged particles including measuring the momentum of a charged particle passing through a charged particle detector. Sets of position sensitive detectors measure scattering of the charged particle. The position sensitive detectors having sufficient mass to cause the charged particle passing through the position sensitive detectors to scatter in the position sensitive detectors. A controller can be adapted and arranged to receive scattering measurements of the charged particle from the charged particle detector, determine at least one trajectory of the charged particle from the measured scattering; and determine at least one momentum measurement of the charged particle from the at least one trajectory. The charged particle can be a cosmic ray-produced charged particle, such as a cosmic ray-produced muon. The position sensitive detectors can be drift cells, such as gas-filled drift tubes.

Morris, Christopher↗

Study of Nonlinear Dynamics of Intense Charged Particle Beams in the Paul Trap Simulator Experiment

The Paul Trap Simulator Experiment (PTSX) is a compact laboratory device that simulates the nonlinear dynamics of intense charged particle beams propagating over a large distance in an alternating-gradient magnetic transport system. The radial quadrupole electric eld forces on the charged particles in the Paul Trap are analogous to the radial forces on the charged particles in the quadrupole magnetic transport system. The amplitude of oscillating voltage applied to the cylindrical electrodes in PTSX is equivalent to the quadrupole magnetic eld gradient in accelerators. The temporal periodicity in PTSX corresponds to the spatial periodicity in magnetic transport system. This thesis focuses on investigations of envelope instabilities and collective mode excitations, properties of high-intensity beams with significant space-charge effects, random noise-induced beam degradation and a laser-induced-fluorescence diagnostic. To better understand the nonlinear dynamics of the charged particle beams, it is critical to understand the collective processes of the charged particles. Charged particle beams support a variety of collective modes, among which the quadrupole mode and the dipole mode are of the greatest interest. We used quadrupole and dipole perturbations to excite the quadrupole and dipole mode respectively and study the effects of those collective modes on the charge bunch. The experimental and particle-in-cell (PIC) simulation results both show that when the frequency and the spatial structure of the external perturbation are matched with the corresponding collective mode, that mode will be excited to a large amplitude and resonates strongly with the external perturbation, usually causing expansion of the charge bunch and loss of particles. Machine imperfections are inevitable for accelerator systems, and we use random noise to simulate the effects of machine imperfection on the charged particle beams. The random noise can be Fourier decomposed into various frequency components and experimental results show that when the random noise has a large frequency component that matches a certain collective mode, the mode will also be excited and cause heating of the charge bunch. It is also noted that by rearranging the order of the random noise, the adverse effects of the random noise may be eliminated. As a non-destructive diagnostic method, a laser-induced- fluorescence (LIF) diagnostic is developed to study the transverse dynamics of the charged particle beams. The accompanying barium ion source and dye laser system are developed and tested.

LIF↗

What is the Impact of Utility Demand Charges on a DCFC host

The PEV Electric Vehicle Supply Equipment (EVSE) delivered by The EV Project included both AC Level 2 and DCFC units. Over 100 of these dual-port Blink DC fast chargers were deployed by The EV Project. These DCFCs were installed in workplaces and in publicly accessible locations near traffic hubs, retail centers, parking lots, restaurants, and similar locations. The Blink DCFC is capable of charging at power up to 60 kW. Its dual-port design sequences the charge from one port to the other, delivering power to only one of two vehicles connected at a time. The actual power delivered through a port is determined by the PEV’s on-board battery management system (BMS). Both the power and the total energy used to recharge a PEV can represent a significant cost for the charging site host. Many electric utilities impose fees for power demand as part of their commercial rate structure. The demand charge incurred by a customer is related to the peak power used during a monthly billing cycle. This is in contrast to the cumulative total energy usage that is the more familiar utility charge seen for most residential services. A demand charge is typically assessed for the highest average power over any 15 minute interval during the monthly billing cycle. One objective of The EV Project was to identify and elucidate the motivations and barriers to potential DCFC site hosts. The application of electric utility demand charges is one such potential barrier. This subject was introduced in the paper: DC Fast Charge - Demand Charge Reduction1. It discussed demand charge impact in general terms in order to focus on potential mitigation actions. This paper identifies specific cases in order to quantify the impact of demand charges on EV Project DCFC hosts.

33 ADVANCED PROPULSION SYSTEMS↗

What is the Impact of Utility Demand Charges on an Alternating Current Level 2 Elective Vehicle Supply Equipment Host?

The EVSE delivered by The EV Project included both residential and non-residential units. Approximately 4,000 non-residential ACL2 EVSE were installed in workplace environments, fleet applications and publicly accessible locations near retail centers, parking lots, and similar locations. The Blink ACL2 utilized in The EV Project is capable of charging at up to 7.2 kW power, although most vehicles in The EV Project charged at about 3.7 kW. This power can be a significant additional electrical load for the charging site host. This concern becomes greater when several EVSE are in operation on a site at the same time. Many electric utilities include maximum power demand as part of their commercial rate structure. The demand charge incurred by a commercial customer is related to the peak power used during a monthly billing cycle. This is in contrast to the total energy usage that is the more familiar utility charge seen for residential service. A demand charge is typically calculated based on the highest average power level over a 15 minute period during the monthly billing cycle and is not a cumulative-type charge. One objective of The EV Project was to elucidate the motivations and hindrances to potential site hosts of non-residential EVSE. The imposition of electric utility demand charges represents such a potential hindrance. This subject was introduced in the paper: DC Fast Charge - Demand Charge Reduction1, specifically dealing with DC Fast Chargers. The concept remains relevant to ACL2 EVSE, especially when several EVSE are deployed at the same site, which occurred frequently in the EV Project. In fact, the average number of ACL2 EVSE per site was 2.58 and varied by market from 1.79 to 3.45 per site. This paper identifies the impact of demand charges on non-residential ACL2 hosts in The EV Project

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Use and Siting of Electric Vehicle Charging Stations in Juneau, Alaska

This report details a study of electric vehicle (EV) Level 2 charging stations in Juneau, Alaska. Utilization analyses of six public over five years and 250 residential chargers over two years are included, and a composite score is introduced to identify optimal locations for future charging stations that target residents of manufactured and multifamily housing (MMFH) in Juneau. We find that public charging station usage is very location-dependent, with three chargers in use more than 60% of days during the peak hour of the day (which ranges from 10 a.m. to 7 p.m.), including a charger near residential housing, illuminating potential needs for additional public chargers in those areas. Residential charging utilization typically occurs overnight - opposite to most public charging stations analyzed - and spikes after 10 p.m. This suggests that Alaska Electric Light & Power Company's time-of-use charging program, which lowers electricity rates at 10 p.m. to incentivize overnight charging, is very effective. Residential charging data also show that households tend to charge 15 hours per week, or 9% of the time, meaning that multiple households could likely share one charger if one were provided near MMFH locations. This is supported by residential charging session analysis, which shows that the median household has around two night charging sessions per week. The EV siting analysis identifies areas of high housing density, low access to public chargers, and unconstrained feeders. A cluster of MMFH parcels in Douglas demonstrated the highest composite scores considering all factors, being the only area to have a perfect score of 2.25.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Technology solutions to mitigate electricity cost for electric vehicle DC fast charging

Widespread adoption of alternative fuel vehicles is being hindered by high vehicle costs and refueling or range limitations. For plug-in electric vehicles, direct-current fast charging (DCFC) is proposed as a solution to support long-distance travel and relieve range anxiety. However, DCFC has also been shown to be potentially more expensive compared to residential or workplace charging. In particular, electricity demand charges can significantly impact electricity cost for fast charging applications. Here we explore technological solutions that can help reduce the electricity cost for electric vehicle fast charging. In particular, we consider thousands of electricity rates available in the United States and real-world vehicle charging load scenarios to assess opportunities to reduce the cost of DCFC by deploying solar photovoltaics (PV) panels and energy storage (battery), and implementing a co-location configuration where a DCFC station is connected to an existing meter within a commercial building. Results show that while the median electricity cost across more than 7000 commercial retail rates remains less than $0.20/kWh for all charging load scenarios considered, cost varies greatly, and some locations do experience significantly higher electricity cost. Co-location is almost always economically viable to mitigate fixed cost and demand charges, but the relative benefit of co-locating diminishes as station size and utilization increase. Energy storage alone can help mitigate demand charges and is more effective at reducing costs for 'peaky' or low-utilization loads. On the other hand, PV systems primarily help mitigate energy charges, and are more effective for loads that are more correlated with solar production, even in areas with lower solar resource. PV and energy storage can deploy synergistically to provide cost reductions for DCFC, leveraging their ability to mitigate demand and energy charges.

25 ENERGY STORAGE↗

Data mining of plug-in electric vehicles charging behavior using supply-side data

This paper aims to better understand the charging patterns of plug-in electric vehicles (PEVs) and identify factors that may significantly impact PEVs’ charging behavior. We collected 189,864 supply-side charging session data over 13 months from 821 charging stations in Illinois from ChargePoint. Through descriptive and regression analyses, we characterize the distributions of key charging behavior indicators, including charging location, dwell time, and battery start state of charge (SOC), and quantify the impacts of closely related factors on these charging behaviors. In this work, we find that: (1) PEVs are more likely to charge in the morning at multifamily commercial locations with a lower start SOC compared with single family residential locations; (2) Weekday and morning sessions are more likely to utilize workplace charging and have shorter dwell time compared with weekend and afternoon sessions; (3) Single family residential area and locations with Levels 1/2 chargers have a higher start SOC and longer dwell time compared with other locations and DC fast chargers (DCFCs). These findings provide policy insights to identify potential time and locations to incentivize PEVs for grid services, as well as identify critical location categories for further charging infrastructure investment to better reduce range anxiety and promote PEV adoption.

33 ADVANCED PROPULSION SYSTEMS↗

Understanding particle size effect on fast-charging behavior of graphite anode using ultra-thin-layer electrodes

Extreme fast charging (≤ 15 min) of lithium-ion batteries is highly desirable to accelerate mass-market adoption of electric vehicles. However, significant capacity fading, as well as safety issues due to the lithium plating caused by the fast charging rate, limit its implementation. In this study, we investigated the fast-charging capability of graphite materials with various particle sizes. To eliminate the Li + ion concentration gradient effect across the thickness of the electrode, ultra-thin-layer graphite electrodes were developed to investigate the "real" fast-charging capability of graphite at the particle level. Electrochemical assessments as well as microscopic characterizations revealed that smaller particles exhibited superior fast-charging performance, featuring enhanced capacity reversibility, faster charging rate, and less lithium plating under the same fast-charging conditions. It is shown that small-particle graphite (mean radius of 3.3 μm) could withstand a 4C charge (to 80 % state-of-charge) without plating, with minimal plating occurring at 6C. Thicker particles exhibited plating at lower C-rates. Since the experimental data could not directly explain whether intra-particle diffusion limitations or interfacial reaction limitations dominated the plating mechanism, the pseudo-2-dimensional model was used to evaluate the most likely plating mechanism. The model suggested that particle-level diffusion is the dominant mechanism contributing to plating at high rates. Finally, this work provides comprehensive insights into the particle size effects on fast-charging capability, offering a better understanding of fast-charging behavior and valuable guidance for designing optimal electrode architecture for high-rate lithium-ion batteries.

25 ENERGY STORAGE↗

Electrifying New York City Ride-Hailing fleets: An examination of the need for public fast charging

This report assesses the scale of public fast charging needed to electrify approximately 20,000 vehicles across the yellow cab and for-hire segments in New York City. The analysis considers real-world trip data in conjunction with driver home locations, overnight charging access rates, driver schedules, and more. Outcomes indicate that the existing charging network in New York City is not adequate even in the most optimistic scenario; 1,054 150-kW ports are required when 15% of drivers have access to overnight charging, whereas 367 150-kW ports are needed when 100% of drivers have access. Results also indicate that although charging is demanded in areas nearby high trip demand, fast charging ports are also demanded in areas near driver residences as a supplement for home charging in scenarios with limited overnight charging access. These findings motivate investment into both overnight charging and public fast charging to meet the charging demands of ride-hailing fleets.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Techno-economic and environmental assessment of solar-based electrical vehicles charging stations integrated with hydrogen production

With the growing interest in adopting both commercial and residential electric vehicles (EVs) utilizing green renewable energy, the techno-economic assessment of EV charging stations with solar energy is a critical aspect of the transition to sustainable transportation. However, battery storage capacity for variable solar energy production is becoming increasingly less cost-effective due to the higher Lithium price. Complementing solar energy production and battery storage, the potential of combining green hydrogen fuel energy integration with solar energy for EV charging stations can provide a sustainable alternative to reach carbon-free transportation. This research aims to assess the technical and economic viability of grid-connected Photovoltaic (PV)-based EV charging stations across Kentucky based on existing EV load profiles. The study considers different PV system sizes, locations, orientations, and the impact of net metering policies and electricity tariffs on the profitability of the PV systems. Further, using excess PV energy, Lithium-Ion batteries will be charged, which will be assessed considering the techno-economic and environmental impacts of green EV charging stations. To further enhance green renewable energy production, we also investigated the feasibility of on-grid PV-based EV charging stations with Lithium-Ion batteries charged during low tariff periods. In comparison with these scenarios, we studied the potential benefits of integrating green hydrogen energy production using excess solar energy with and without governmental incentives. Furthermore, we assess the environmental impact of these green EV charging stations across Kentucky. Our study indicates that EV stations across Kentucky have similar techno-economic feasibility with insignificant deviation in the levelized cost of electricity, payback period, and PV energy fraction with/without Li-Ion batteries. However, with green hydrogen production, the marginal H 2 production cost indicates the first scenario (on-grid PV energy charging) is the most significant, roughly 10 USD/Kg, which is similar to 1.5 times higher than the second (charging during low-tariff periods) and the third scenarios (power grid to satisfy the demand deficit - approximately 6.5 USD/Kg). From the environmental perspective, the second scenario would be a good option for either hybrid EV/H 2 or EV charging stations in Kentucky, factoring in the hydrogen production cost and the carbon footprint.

08 HYDROGEN↗

Modeling charging behavior of battery electric vehicle drivers: A cumulative prospect theory based approach

The behavior of drivers in charging a battery electric vehicle (BEV) can be influenced by psychological factors such as personality and risk preference. This paper proposes a cumulative prospect theory (CPT) based modeling framework to describe the charging behavior of BEV drivers. CPT captures an individual’s attitude and preference toward risk in the decision-making process. A BEV mass-market scenario is constructed using the 2017 National Household Travel Survey (NHTS) data. This work applies the CPT-based charging behavior model to study the battery state-of-charge (SOC) when drivers decide to charge their vehicles, charging timing and location choices, and charging power demand profile under the mass-market scenario. In addition, sensitivity analyses are used to examine the drivers’ risk attitudes and public charger network coverage. BEV drivers who reflect a higher degree of risk-seeking tend to charge vehicles at a lower SOC. Some home charging shifts to workplace and public charging as the public charger network expands, but home charging still plays the most significant role in BEV use. The power demand from public chargers increases critically with BEV expansion and has a larger impact on the power grid. The time-of-use (TOU) electricity rate can shift peak power demand to off-peak periods from midnight to early morning.

2017 National Household Travel Survey (NHTS)↗

Learning-based demand-supply-coupled charging station location problem for electric vehicle demand management

We present a learning-based, demand-supply-coupled optimization model for the charging station location problem (CSLP), aiming to integrate the concept of electric vehicle (EV) charging demand management into the planning of charging infrastructures. In stage one, a gradient boosting-based learning model is developed to predict the charging demand of a charging station based on 15 defined features. Next, in stage two, a demand–supply-coupled CSLP model is developed to optimize the total charging usage rates of both existing and newly selected charging stations. We design a gradient-based stochastic spatial search algorithm to solve the proposed model. A case study with 6-year charging event data from Kansas City Missouri is performed. Results show that the proposed method can generate satisfactory charging demand predictions, and can increase charging usage rates by 14%, outperforming two benchmark approaches. Furthermore, the results of this research are poised to guide agencies in identifying optimal locations for new charging stations.

33 ADVANCED PROPULSION SYSTEMS↗

Charge Breeding Application of EBIS/T Devices

The demand of highly charged ions of isotopes from all mass regions of the nuclear chart for low energy experiment or for the post acceleration has driven the development of different charge breeding methods. Charge state breeder employ high charge state ion sources like the Electron Beam Ion Source/Trap (EBIS/T) and the Electron Cyclotron Resonance Ion Source (ECRIS). Existing radioactive beam facilities like REX-ISOLDE or ISAC (TRIUMF) are already using charge state boosters for the post acceleration of radioactive ions. Upcoming facilities like the MSU re-accelerator project, SPIRAL II, SPES, EURISOL and MATS within FAIR have identified the need of a breeding system, because of the demand for highly charged ions at low energies and due to the available budget. Charge state breeding with EBIS/T devices requires several steps, which need to be optimized. A beam of singly charged ions must be prepared prior to injection into an EBIS/T in order to match the acceptance of the electron beam. An efficient injection and short breeding times are required as well as a high abundance in one specific charge state, which can be manipulated in EBIS/T devices. Further issues of charge breeder development are extraction and purification of the wanted highly charged ion species. The present paper will review the efforts of the EBIS/T community and will give an overview of the planned and running facilities.

43 PARTICLE ACCELERATORS↗

Particle size effects in particle-particle triboelectric charging studied with an integrated fluidized bed and electrostatic separator system

Fundamental studies of triboelectric charging of granular materials via particle-particle contact are challenging to control and interpret because of foreign material surfaces that are difficult to avoid during contacting and measurement. The measurement of particle charge itself can also induce charging, altering results. Here, we introduce a completely integrated fluidized bed and electrostatic separator system that charges particles solely by interparticle interactions and characterizes their charge on line. Particles are contacted in a free-surface fluidized bed (no reactor walls) with a well-controlled fountain-like flow to regulate particle-particle contact. The charged particles in the fountain are transferred by a pulsed jet of air to the top of a vertically-oriented electrostatic separator consisting of two electrodes at oppositely biased high voltage. The free-falling particles migrate towards the electrodes of opposite charge and are collected by an array of cups where their charge and size can be determined. We carried out experiments on a bidisperse size mixture of soda lime glass particles with systematically varying ratios of concentration. Results show that larger particles fall close to the negative electrode and smaller particles fall close to the positive electrode, consistent with theory and prior experiments that larger particles charge positively and smaller particles charge negatively. The segregation of particles by charge for one of the size components is strongest when its collisions are mostly with particles of the other size component; thus, small particles segregate most strongly to the negative sample when their concentration in the mixture is small (and analogous results occur for the large particles). Furthermore, we find additional size segregation due to granular flow, whereby the fountain becomes enriched in larger particles as the smaller particles are preferentially expelled from the fountain.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Interpretable Machine Learning for Characterizing Electric Vehicle Charging Behavior: Insights from Real-World Data

As electric vehicle (EV) adoption rises globally, concerns about the impact on aging electrical grids grow, particularly regarding the charging behavior of EV drivers. This study analyzes real-world driving and charging data from Ford battery electric vehicles (BEVs) collected between 2018 and 2019 to develop interpretable models that characterize charging behavior and quantify influencing factors. Prior research has relied on assumptions regarding driver behavior, often overlooking actual charging patterns. By employing generalized linear mixed models (GLMMs), this work offers insights into how various elements, such as next trip distance and state of charge (SOC), influence charging decisions. The dataset comprises over three million park-trip pairs from 1,997 vehicles, revealing that features related to driving behavior significantly dictate charging behavior, while infrastructure and regional factors have lesser impacts. The findings suggest that existing simulation models may oversimplify EV charging behavior assumptions. This work utilizes real-world EV driving and charging data to train interpretable models that describe charging behavior and quantify the factors most associated with how drivers use charging infrastructure. This research underscores the need for interpretable, data-driven methodologies to inform future EV infrastructure planning and grid management.

29 - ENERGY PLANNING, POLICY AND ECONOMY↗