Theory of open-ended circular cylindrical microwave cavity
Theory for open-ended circular cylindrical microwave cavities developed by using Laplace transform and Wiener-Hope techniques
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Theory for open-ended circular cylindrical microwave cavities developed by using Laplace transform and Wiener-Hope techniques
Technique for measuring dielectric constants using rectangular cavity resonator
Wall vibrations and amplitude attenuations measured in tunnel and cavity formed by underground nuclear explosion
Cyclotron radius, magnetospheric boundary and Debye length scaling parameters for magnetospheric cavity arising from solar wind- induced geomagnetic storm and visibility of quasi- Van Allen belts
Local emissivity of vertex point of diffuse conical or V-groove cavity, noting dependence on wall material, angle factor and agreement with theoretical solution
Microwave cavity resonant frequency sampler for direct oscilloscope-photographic recording of electron density, recombination and diffusion time in decaying plasma
Finite expansion of spherical cavity in locking medium using finite strain theory
Stress concentrations near elliptical and rectangular cavities in incompressible material calculated by determining biharmonic functions
Vacuum resonant-cavity dielectrometer for in situ measurements of complex permittivity in simulated space environment
Oscillation mode in open-ended circular cylindrical microwave cavity resonant frequency computed by Laplace transform and Wiener-Hopf techniques
Optical microsphere cavities, with their exceptionally high quality-factor and submillimeter dimensions, present an attractive new building block for fiber optics and photonics applications.
There has been a concerted effort to improve the microwave heating technique for processing materials at high temperature. Improved optimization of the energy transfer from a microwave source to the material being processed is required. A vibration technique is pre- sented to continuously maintain a mode resonance and impedance match between a constant frequency magnetron source and a resonant cavity.
Here we study the effect of nitrogen insertion on the electronic spectra of polycyclic aromatic hydrocarbon (PAH) molecules measured under laboratory conditions that are relevant for comparison with astronomical data. We examine the case of the substitution of carbon atoms by nitrogen atoms in the benzenoid skeleton of phenanthrene (C 14 H 10 ), a prototype non-compact PAH. The vibronic transitions of the 2 1 A 1 (S 1 )←X 1 A 1 (S 0 ) electronic absorption band system of neutral phenanthrene (C 14 H 10 ) and phenanthridine (C 13 H 9 N) molecules seeded in a supersonic free jet expansion of argon gas are measured in the 315-345 nm region using the cavity ring down spectroscopy (CRDS) technique. Additional measurements of the absorption spectra of the phenanthrene, phenanthridine, and 1,10-phenanthroline (C 12 H 8 N 2 ) molecules isolated in 10-K solid argon matrices are also presented. The results obtained confirm that laboratory spectra of cold, isolated molecules obtained under astrophysically relevant conditions are required for a direct, unambiguous comparison with astronomical observations as well as for the understanding of the physical evolution of the interstellar medium.
Presents the design of a fast-tuning system based on nickel-zinc ferrite for a 24.6 MHz accelerating cavity, developed to compensate for frequency shifts during transition crossing in a hadron storage ring. Covers ferrite material selection, tuner mechanical design, and expected RF performance.
Here, in this work, the design and execution of an experiment with the goal of demonstrating control over the evolution of a copper jet is described. Simulations show that when using simple multi-material buffers placed between a copper target with a conical cavity and a cylinder of high-explosive, a variety of jetting behaviors occur based on material placement, including both jet velocity augmentation and mitigation. A parameter sweep was performed to determine optimal buffer designs in two configurations. Experiments using the optimal buffer designs verified the effectiveness of the buffers at altering jet velocities. Similar trends were shown between the experimental results and the modeling.
Concentrated solar power (CSP) is one of the most effective ways of harnessing solar power to create efficient, durable, and resilient energy systems. This study entails thermal modeling and analysis of a novel central tower receiver configuration. This receiver uses solid particles as the heat transfer fluid (HTF), a promising option for third-generation CSP systems. The configuration considered here is the light-trapping planar cavity receiver (LTPCR) introduced by the National Renewable Energy Laboratory. While heat transfer studies of various LTPCR subsystems have been done, system-level thermal analysis of the LTPCR receiver has not been attempted. This study also presents important sensitivity analyses of the operating parameters of the CSP system, which can help guide the design of future central tower receivers. This study employs Ansys Fluent as a computational fluid dynamics (CFD) tool to model fluid dynamics and heat transfer in the receiver, intending to quantify its thermal performance. The model seamlessly integrates Monte Carlo ray tracing data, which generates absorbed solar flux profiles from the heliostat field design, with the heat transfer characteristics of the fluidized particle bed. This unified model is designed to accurately predict the thermal behavior of the LTPCR. Analysis of preliminary results reveals that the primary loss mechanisms are radiative and natural convective losses, in that order. Based on observations from a baseline case, several strategies are suggested and numerically tested. These solutions include selective cooling of high-temperature regions and manipulation of particle bed parameters. Selective cooling of high-temperature regions reduced the peak temperature by 151 degrees C and decreased thermal losses by 0.9%. Improving the particle-wall heat transfer coefficient (P-W HTC) of the particle bed decreased the thermal losses by 1.7% and decreased the peak temperatures by 57 degrees C. Decreasing the particle inlet temperature (PIT) also reduced thermal losses by 3.5% and decreased peak temperatures by 29 degrees C. Compounding these strategies improved the thermal losses of the receiver from 13.5% in the baseline case to 7.5%. Additionally, the study explores the variation in thermal performance across different locations of the receiver, where a variation of thermal losses from 12.9% to 17.3% is found. This allows a comprehensive evaluation of potential improvements in efficiency and temperature management.
The purpose of this critical review is to summarize the literature specific to single-fraction stereotactic radiosurgery (SRS) and multiple-fraction stereotactic radiation therapy (SRT) for postoperative brain metastases resection cavities and to present practice recommendations on behalf of the ISRS.
Microstructural evolutions in two variants of the F82H 8 wt%Cr tempered martensitic steel under dual (He + plus Fe 3+ ) ion irradiations at 500 °C have been characterized by transmission electron microscopy. Emphasis is on understanding the combined effects of displacements per atom (dpa) and the helium/dpa ratio (He/dpa) on cavity evolution and void swelling (f v ). The dual ion database includes 231 alloy-dpa-He/dpa conditions for irradiations up to ~ 82 dpa and 3700 appm helium. Here, we hypothesize that the large “scatter” observed in the f v data is primarily due to local microstructural variations, especially those that shield regions at shallower depths from the effects of injected interstitial atoms, which would otherwise reduce f v . More generally, our hypothesis is that the highest f v data, at a specified dpa and He/dpa, provides the most appropriate estimate of swelling for fusion neutron irradiation conditions. The dose dependence of f v can be described by an incubation dpa i , marking the onset of significant void growth, and a post-incubation swelling rate, f v ’ = Δf v /Δdpa. Both dpa i and f v ’ decrease with increasing He/dpa. The f v ’ data are quantitatively consistent with a simple model for defect partitioning between evolving bubble, void, and dislocation sinks strengths and biases. Most notably, the model correctly predicts both the incubation dpa i , and the subsequent f v ’, in spite of the fact that they reflect somewhat different physics. Our analysis also suggests that defect recombination is modest at 500 °C. Along with other considerations, this supports the hypothesis that, even at high dpa rates, dual ion irradiations can be used to reasonably emulate void nucleation and growth for a range of fusion-relevant neutron irradiation service conditions. A companion paper incorporates the results of this study in a reduced-order, data-driven void swelling model.