Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “calibrated”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

Upgrade of the Lyman-alpha diagnostic system on DIII-D for main chamber edge neutral studies

The LLAMA (Lyman Alpha Measurement Apparatus) pinhole camera diagnostic had previously been deployed on DIII-D to measure radial profiles of the Lyman-α (Ly-α) deuterium neutral line brightness across the plasma boundary in the lower chamber to infer neutral deuterium density and ionization rate profiles. This system has recently been upgraded with a new diagnostic head, named ALPACA, that also encloses two pinhole cameras and duplicates the LLAMA views in the upper chamber. Similar to LLAMA, ALPACA provides two times 20 lines of sight, viewing the plasma edge on the inboard and outboard sides with a radial resolution of ~2.5 cm (FWHM) and an effective time resolution of ~1 ms that allows for the investigation of inter-ELM dynamics. The extended Ly-α system provides better coverage to study neutrals in experiments with various plasma shapes utilizing both the upper and lower divertors. Furthermore, post-campaign calibration of the LLAMA diagnostic has successfully been demonstrated for the first time. This was facilitated by various upgrades to the calibration set-up and detailed measurements of the emissivity distribution of the Ly-α calibration source using a pinhole collimator. It was found that the sensitivity of the inboard LLAMA pinhole camera was reduced by a factor of 2.0 ± 0.2 over the course of six months of plasma operation in 2021. In conclusion, the upgraded Ly-α system, equipped with improved absolute calibration, will provide key input for neutral fueling and pedestal particle transport studies and for 2D edge transport code validation on the DIII-D tokamak.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Sensitivity of an integrated experiment to uncertainty in the high explosive equations of state

Traditionally, hydrodynamics simulations are performed with a single equation-of-state (EOS) to describe each material. These EOSs typically have a physics-informed functional form with adjustable parameters that are calibrated in order to replicate small-scale data. However, because the calibration data have uncertainty and there are typically inherent degeneracies in fitting the EOS, there are actually multiple EOSs that might be consistent with calibration data. In this work, we perform uncertainty quantification (UQ) for the reactant and product equations of state for the high explosive PBX 9501 to yield an ensemble of EOSs that match the uncertain small-scale calibration data. We then simulate an experiment of an explosively formed penetrator repeatedly with different EOSs to both validate the UQ analysis and determine the effects of EOS uncertainty on the prediction of quantities of interest in the experiment. In general, we find good agreement between the simulation predictions and the experimental measurements, and we identify an EOS variable that contributes most directly to the spread in the predictions as the EOSs are varied.

36 MATERIALS SCIENCE↗

Variational inference of effective range parameters for 3 He− 4 He scattering

We use two different methods, Monte Carlo sampling and variational inference (VI), to perform a Bayesian calibration of the effective-range parameters in 3 He– 4 He elastic scattering. The parameters are calibrated to data from a recent set of 3 He– 4 He elastic scattering differential cross section measurements. Analysis of these data for E lab ≤ 4.3 MeV yields a unimodal posterior for which both methods obtain the same structure. However, the effective-range expansion amplitude does not account for the 7/2 − state of 7 Be so, even after calibration, the description of data at the upper end of this energy range is poor. The data up to E lab = 2.6 MeV can be well described, but calibration to this lower-energy subset of the data yields a bimodal posterior. After adapting VI to treat such a multi-modal posterior we find good agreement between the VI results and those obtained with parallel-tempered Monte Carlo sampling.

effective field theory↗

Characterization of uncertainties in electron-argon collision cross sections

Abstract The predictive capability of a plasma discharge model depends on accurate representations of electron-impact collision cross sections, which determine the corresponding reaction rates and electron transport properties. The values of cross sections can be known only approximately either through experiments or simulations and are thus subject to uncertainties. Quantifying the uncertainties in plasma simulations allows us to assess the reliability of simulations and to provide a basis for interpreting discrepancies between simulations and experiments. For such uncertainty quantification of plasma simulations, it is essential to quantify the uncertainties of the underlying cross sections. Although much effort has been committed to calibrate the cross section values, their uncertainties are not well investigated. We characterize uncertainties in electron-argon atom collision cross sections using a Bayesian framework. Six collision processes—elastic momentum transfer, ionization, and four excitations—are characterized with semi-empirical models, which effectively capture the features important to the macroscopic properties of the plasma. A probability model for the uncertain parameters of these semi-empirical models is developed. Specifically, a Gaussian-process likelihood model is proposed to capture discrepancies among data sets, as well as the model-form inadequacies of the semi-empirical models. Two other likelihood models are compared with the proposed Gaussian-process model, to illustrate the importance of the choice of the likelihood model. The cross section models are calibrated using the electron-beam experiments and ab-inito quantum simulations. The resulting calibrated uncertainties capture well the scattering among the data sets. The calibrated cross section models are further validated against swarm-parameter experiments and zero-dimensional Boltzmann equation simulations of widely used cross section datasets.

Chung, Seung Whan (ORCID:0000000302501549)↗

Combining cosmic shear data with correlated photo-z uncertainties: constraints from DESY1 and HSC-DR1

An accurate calibration of the source redshift distribution p(z) is a key aspect in the analysis of cosmic shear data. This, one way or another, requires the use of spectroscopic or high-quality photometric samples. However, the difficulty to obtain colour-complete spectroscopic samples matching the depth of weak lensing catalogs means that the analyses of different cosmic shear datasets often use the same samples for redshift calibration. This introduces a source of statistical and systematic uncertainty that is highly correlated across different weak lensing datasets, and which must be accurately characterised and propagated in order to obtain robust cosmological constraints from their combination. In this paper we introduce a method to quantify and propagate the uncertainties on the source redshift distribution in two different surveys sharing the same calibrating sample. The method is based on an approximate analytical marginalisation of the p(z) statistical uncertainties and the correlated marginalisation of residual systematics. We apply this method to the combined analysis of cosmic shear data from the DESY1 data release and the HSC-DR1 data, using the COSMOS 30-band catalog as a common redshift calibration sample. We find that, although there is significant correlation in the uncertainties on the redshift distributions of both samples, this does not change the final constraints on cosmological parameters significantly. The same is true also for the impact of residual systematic uncertainties from the errors in the COSMOS 30-band photometric redshifts. Additionally, we show that these effects will still be negligible in Stage-IV datasets. Finally, the combination of DESY1 and HSC-DR1 allows us to constrain the "clumpiness" parameter to S 8 = ${0.768}_{-0.017}^{+0.021}$. This corresponds to a ~√(2) improvement in uncertainties with respect to either DES or HSC alone.

79 ASTRONOMY AND ASTROPHYSICS↗

Deep inference of simulated strong lenses in ground-based surveys

The large number of strong lenses discoverable in future astronomical surveys will likely enhance the value of strong gravitational lensing as a cosmic probe of dark energy and dark matter. However, leveraging the increased statistical power of such large samples will require further development of automated lens modeling techniques. We show that deep learning and simulation-based inference (SBI) methods produce informative and reliable estimates of parameter posteriors for strong lensing systems in ground-based surveys. We present the examination and comparison of two approaches to lens parameter estimation for strong galaxy-galaxy lenses — Neural Posterior Estimation (NPE) and Bayesian Neural Networks (BNNs). We perform inference on 1-, 5-, and 12-parameter lens models for ground-based imaging data that mimics the Dark Energy Survey (DES). We find that NPE outperforms BNNs, producing posterior distributions that are more accurate, precise, and well-calibrated for most parameters. For the 12-parameter NPE model, the calibration is consistently within <10% of optimal calibration for all parameters, while the BNN is rarely within 20% of optimal calibration for any of the parameters. Similarly, residuals for most of the parameters are smaller (by up to an order of magnitude) with the NPE model than the BNN model. This work takes important steps in the systematic comparison of methods for different levels of model complexity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Differentiable Simulation of a Liquid Argon Time Projection Chamber

Liquid argon time projection chambers (LArTPCs) are widely used in particle detection for their tracking and calorimetric capabilities. The particle physics community actively builds and improves high-quality simulators for such detectors in order to develop physics analyses in a realistic setting. The ability of these simulators to mimic real, measured data is limited by the modeling of the physical detectors used for data collection. This modeling can be improved by performing dedicated calibration measurements. Conventional approaches calibrate individual detector parameters or processes one at a time. However, the impact of detector processes is entangled, making this a poor description of the underlying physics. We introduce a differentiable simulator that enables a gradient-based optimization, allowing for the first time a simultaneous calibration of all detector parameters. We describe the procedure of making a differentiable simulator, highlighting the challenges of retaining the physics quality of the standard, non-differentiable version while providing meaningful gradient information. We further discuss the advantages and drawbacks of using our differentiable simulator for calibration. Finally, we provide a starting point for extensions to our approach, including applications of the differentiable simulator to physics analysis pipelines.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Evaluating probabilistic deep learning methods for uncertainty quantification of temperature downscaling

Deep learning (DL) has emerged as a promising tool for downscaling coarse-resolution climate data to high-resolution outputs, enabling improved regional climate predictions. A critical aspect of DL-based downscaling is the incorporation of uncertainty quantification (UQ), which enhances the interpretability and reliability of predictions—key factors for climate risk assessment and decision-making. This study develops a DL model to downscale 2 m temperature across the contiguous United States using reanalysis datasets. We systematically evaluate three epistemic UQ methods—deep ensembles (DEns), Monte Carlo dropout (MCD), and Flipout—based on their probabilistic accuracy, downscaling performance, sensitivity to geographical features, and computational efficiency. Results indicate that MCD generally outperforms Flipout and DEns in terms of calibration and downscaling accuracy. However, DEns demonstrate lower calibration errors in coastal regions, indicating its higher confidence within these areas. Flipout, in contrast, is more sensitive to elevation gradients and exhibits higher calibration errors in mountainous regions. Hence, the choice of UQ method for this task depends on the specific requirements of the application. For applications that prioritize overall calibration, downscaling accuracy, and computational efficiency, MCD is a strong candidate. These findings highlight the importance of selecting UQ methods based on application-specific requirements, such as geographical context and computational constraints. By addressing the trade-offs between UQ methods, this study provides actionable insights for improving the reliability, scalability, and utility of DL-based downscaling in climate science.

Environmental sciences↗

Dark Energy Survey Y3 results: blending shear and redshift biases in image simulations

ABSTRACT As the statistical power of galaxy weak lensing reaches per cent level precision, large, realistic, and robust simulations are required to calibrate observational systematics, especially given the increased importance of object blending as survey depths increase. To capture the coupled effects of blending in both shear and photometric redshift calibration, we define the effective redshift distribution for lensing, nγ(z), and describe how to estimate it using image simulations. We use an extensive suite of tailored image simulations to characterize the performance of the shear estimation pipeline applied to the Dark Energy Survey (DES) Year 3 data set. We describe the multiband, multi-epoch simulations, and demonstrate their high level of realism through comparisons to the real DES data. We isolate the effects that generate shear calibration biases by running variations on our fiducial simulation, and find that blending-related effects are the dominant contribution to the mean multiplicative bias of approximately $-2{{\ \rm per\ cent}}$. By generating simulations with input shear signals that vary with redshift, we calibrate biases in our estimation of the effective redshift distribution, and demonstrate the importance of this approach when blending is present. We provide corrected effective redshift distributions that incorporate statistical and systematic uncertainties, ready for use in DES Year 3 weak lensing analyses.

79 ASTRONOMY AND ASTROPHYSICS↗

A composite likelihood approach for inference under photometric redshift uncertainty

ABSTRACT Obtaining accurately calibrated redshift distributions of photometric samples is one of the great challenges in photometric surveys like LSST, Euclid, HSC, KiDS, and DES. We present an inference methodology that combines the redshift information from the galaxy photometry with constraints from two-point functions, utilizing cross-correlations with spatially overlapping spectroscopic samples, and illustrate the approach on CosmoDC2 simulations. Our likelihood framework is designed to integrate directly into a typical large-scale structure and weak lensing analysis based on two-point functions. We discuss efficient and accurate inference techniques that allow us to scale the method to the large samples of galaxies to be expected in LSST. We consider statistical challenges like the parametrization of redshift systematics, discuss and evaluate techniques to regularize the sample redshift distributions, and investigate techniques that can help to detect and calibrate sources of systematic error using posterior predictive checks. We evaluate and forecast photometric redshift performance using data from the CosmoDC2 simulations, within which we mimic a DESI-like spectroscopic calibration sample for cross-correlations. Using a combination of spatial cross-correlations and photometry, we show that we can provide calibration of the mean of the sample redshift distribution to an accuracy of at least 0.002(1 + z), consistent with the LSST-Y1 science requirements for weak lensing and large-scale structure probes.

(cosmology:) large-scale structure of Universe↗

In-orbit performance of the soft X-ray imaging telescope Xtend aboard XRISM

Here, we present a summary of the in-orbit performance of the soft X-ray imaging telescope Xtend onboard the X-Ray Imaging and Spectroscopy Mission (XRISM), based on in-flight observation data, including first-light celestial objects, calibration sources, and results from the cross-calibration campaign with other currently operating X-ray observatories. XRISM/Xtend has a large field of view of ${38{^{\prime }_{.}}5}$ $\times$ ${38{^{\prime }_{.}}5}$, covering an energy range of 0.4–13 keV, as demonstrated by the first-light observation of the galaxy cluster Abell 2319. It also features an energy resolution of 170–180 eV at 6 keV, which meets the mission requirement and enables us to resolve He-like and H-like Fe K$\alpha$ lines. Throughout the observation during the performance verification phase, we confirm that two issues identified in the Soft X-ray Imager (SXI) onboard the previous Hitomi mission—light leakage and crosstalk events—are addressed and suppressed in the case of Xtend. A joint cross-calibration observation of the bright quasar 3C 273 results in an effective area measured to be $\sim$420 cm$^{2}$ at1.5 keV and $\sim$310 cm$^{2}$ at 6.0 keV, which matches values obtained in ground tests. We also continuously monitor the health of Xtend by analyzing overclocking data, calibration source spectra, and day-Earth observations; the readout noise is stable and low, and contamination is negligible even one year after launch. A low background level compared with other major X-ray instruments onboard satellites, combined with the largest grasp ($\Omega _{\rm eff}\sim 60$ cm$^2$ deg$^2$) of Xtend, will not only support Resolve analysis, but also enable significant scientific results on its own. This includes near-future follow-up observations and transient searches in the context of time-domain and multi-messenger astrophysics.

instrumentation: detectors: Xtend↗

3 He +𝛼 resonances in 7 Be

Resonances in 7 Be which decay into the 3 He+α exit channel have been measured with improved precision using preexisting data sets. The energy and width of the J π =7/2 - state have been extracted from an invariant-mass study of projectile-breakup products originating from interactions of an E/A=10.7-MeV 10 C beam on Be and C targets. The excitation energy of this state (from the pole of the S-matrix) is determined to be E*=4.545(6)~MeV, a factor of 8 improvement in precision as compared to the ENSDF value. This improvement is enabled by fine tuning the detector calibrations using calibration resonances in 6 Li, 7 Li, 6 Be, 9 B, and 12 C whose decay energies are known to high precision. The J π =7/2- resonance in 7 Be can now itself be used as a calibration resonance in invariant-mass experiments. This utility is particularly helpful for 3 He energy calibrations of CsI(Tl) detectors which are often used in detector arrays employed for measurements with fast beams. This utility is demonstrated with a data set associated with E/A=70 MeV 7 Be beams which are inelastically excited to the 7/2 - and 5/2 - 1 resonances. Again using the pole of the S-matrix as the definition of the resonance parameters, the fitted excitation energy of the 5/2 - 1 resonance is 6.376(17) MeV, approximately 300 keV lower than the ENSDF value. Finally, its width of 565(4) keV is roughly half of the ENSDF value.

energy levels↗

Measurement of charge and light yields for 127 Xe L -shell electron captures in liquid xenon

Dark matter searches using dual-phase xenon time-projection chambers (LXe-TPCs) rely on their ability to reject background electron recoils (ERs) while searching for signal-like nuclear recoils (NRs). ER response is typically calibrated using β -decay sources, such as tritium, but these calibrations do not characterize events accompanied by an atomic vacancy, as in solar neutrino scatters off inner-shell electrons. Such events lead to emission of x rays and Auger electrons, resulting in higher electron-ion recombination and thus a more NR-like response than inferred from β -decay calibration. We present a cross-calibration of tritium β -decays and Xe 127 electron-capture decays (which produce inner-shell vacancies) in a small-scale LXe-TPC and give the most precise measurements to date of light and charge yields for the Xe 127 L -shell electron-capture in liquid xenon. We observe a 6.9 σ ( 9.2 σ ) discrepancy in the L -shell capture response relative to tritium β decays, measured at a drift field of 363 ± 14 V / cm ( 258 ± 13 V / cm ), when compared to simulations tuned to reproduce the correct β -decay response. In dark matter searches, use of a background model that neglects this effect leads to overcoverage (higher limits) for background-only multi-kiloton-year exposures, but at a level much less than the 1 - σ experiment-to-experiment variation of the 90% C.L. upper limit on the interaction rate of a 50 GeV / c 2 dark matter particle.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cross-correlation of Dark Energy Survey Year 3 lensing data with ACT and Planck thermal Sunyaev-Zel’dovich effect observations. I. Measurements, systematics tests, and feedback model constraints

Here we present a tomographic measurement of the cross-correlation between thermal Sunyaev-Zel’dovich (TSZ) maps from Planck and the Atacama Cosmology Telescope and weak galaxy lensing shears measured during the first three years of observations of the Dark Energy Survey. This correlation is sensitive to the thermal energy in baryons over a wide redshift range and is therefore a powerful probe of astrophysical feedback. We detect the correlation at a statistical significance of 21σ, the highest significance to date. We examine the TSZ maps for potential contaminants, including cosmic infrared background and radio sources, finding that cosmic infrared background has a substantial impact on our measurements and must be taken into account in our analysis. We use the cross-correlation measurements to test different feedback models. In particular, we model the TSZ using several different pressure profile models calibrated against hydrodynamical simulations. Our analysis marginalizes over redshift uncertainties, shear calibration biases, and intrinsic alignment effects. We also marginalize over Ω m and σ 8 using Planck or DES priors. We find that the data prefer the model with a low amplitude of the pressure profile at small scales, compatible with a scenario with strong active galactic nuclei feedback and ejection of gas from the inner part of the halos. When using a more flexible model for the shear profile, constraints are weaker, and the data cannot discriminate between different baryonic prescriptions.

79 ASTRONOMY AND ASTROPHYSICS↗

Joint analysis of Dark Energy Survey Year 3 data and CMB lensing from SPT and Planck . I. Construction of CMB lensing maps and modeling choices

Joint analyses of cross-correlations between measurements of galaxy positions, galaxy lensing, and lensing of the cosmic microwave background (CMB) offer powerful constraints on the large-scale structure of the Universe. In a forthcoming analysis, we will present cosmological constraints from the analysis of such cross-correlations measured using Year 3 data from the Dark Energy Survey (DES), and CMB data from the South Pole Telescope (SPT) and Planck. Here we present two key ingredients of this analysis: (1) an improved CMB lensing map in the SPT-SZ survey footprint and (2) the analysis methodology that will be used to extract cosmological information from the cross-correlation measurements. Relative to previous lensing maps made from the same CMB observations, we have implemented techniques to remove contamination from the thermal Sunyaev Zel’dovich effect, enabling the extraction of cosmological information from smaller angular scales of the cross-correlation measurements than in previous analyses with DES Year 1 data. We describe our model for the cross-correlations between these maps and DES data, and validate our modeling choices to demonstrate the robustness of our analysis. We then forecast the expected cosmological constraints from the galaxy survey-CMB lensing auto and cross-correlations. We find that the galaxy-CMB lensing and galaxy shear-CMB lensing correlations will on their own provide a constraint on S 8 =σ 8 $\sqrt{Ωm/0.3}$ at the few percent level, providing a powerful consistency check for the DES-only constraints. Finally, we explore scenarios where external priors on shear calibration are removed, finding that the joint analysis of CMB lensing cross-correlations can provide constraints on the shear calibration amplitude at the 5% to 10% level.

79 ASTRONOMY AND ASTROPHYSICS↗

Identification and reconstruction of low-energy electrons in the ProtoDUNE-SP detector

Measurements of electrons from 𝜈𝑒 interactions are crucial for the Deep Underground Neutrino Experiment (DUNE) neutrino oscillation program, as well as searches for physics beyond the standard model, supernova neutrino detection, and solar neutrino measurements. This article describes the selection and reconstruction of low-energy (Michel) electrons in the ProtoDUNE-SP detector. ProtoDUNE-SP is one of the prototypes for the DUNE far detector, built and operated at CERN as a charged particle test beam experiment. A sample of low-energy electrons produced by the decay of cosmic muons is selected with a purity of 95%. This sample is used to calibrate the low-energy electron energy scale with two techniques. An electron energy calibration based on a cosmic ray muon sample uses calibration constants derived from measured and simulated cosmic ray muon events. Another calibration technique makes use of the theoretically well-understood Michel electron energy spectrum to convert reconstructed charge to electron energy. In addition, the effects of detector response to low-energy electron energy scale and its resolution including readout electronics threshold effects are quantified. Finally, the relation between the theoretical and reconstructed low-energy electron energy spectra is derived, and the energy resolution is characterized. The low-energy electron selection presented here accounts for about 75% of the total electron deposited energy. After the addition of lost energy using a Monte Carlo simulation, the energy resolution improves from about 40% to 25% at 50 MeV. These results are used to validate the expected capabilities of the DUNE far detector to reconstruct low-energy electrons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

BICEP/ Keck XVIII: Measurement of BICEP3 polarization angles and consequences for constraining cosmic birefringence and inflation

We use a custom-made calibrator to measure individual detectors’ polarization angles of BICEP3, a small aperture telescope observing the cosmic microwave background (CMB) at 95 GHz from the South Pole. We describe our calibration strategy and the statistical and systematic uncertainties associated with the measurement. We reach an unprecedented precision for such measurement on a CMB experiment, with a repeatability for each detector pair of 0.02°. Here, we show that the relative angles measured using this method are in excellent agreement with those extracted from CMB data. Because the absolute measurement is currently limited by a systematic uncertainty, we do not derive cosmic birefringence constraints from BICEP3 data in this work. Rather, we forecast the sensitivity of BICEP3 sky maps for such analysis. We investigate the relative contributions of instrument noise, lensing, and dust, as well as astrophysical and instrumental systematics. We also explore the constraining power of different angle estimators, depending on analysis choices. We establish that the BICEP3 2-year dataset (2017–2018) has an on-sky sensitivity to the cosmic birefringence angle of 𝜎 𝛼 = 0.07⁢8°, which could be improved to 𝜎 𝛼 = 0.05⁢5° by adding all of the existing BICEP3 data (through 2023). Furthermore, we emphasize the possibility of using the BICEP3 sky patch as a polarization calibration source for CMB experiments, which with the present data could reach a precision of 0.035°. Finally, in the context of inflation searches, we investigate the impact of detector-to-detector variations in polarization angles as they may bias the tensor-to-scalar ratio 𝑟. We show that while the effect is expected to remain subdominant to other sources of systematic uncertainty, it can be reliably calibrated using polarization angle measurements such as the ones we present in this paper.

Cosmic microwave background↗

A new benchmark of soft X-ray transition energies of $$\mathrm {Ne}$$, $$\mathrm {CO}_2$$, and $$\mathrm {SF}_6$$: paving a pathway towards ppm accuracy

Abstract A key requirement for the correct interpretation of high-resolution X-ray spectra is that transition energies are known with high accuracy and precision. We investigate the K-shell features of $$\mathrm {Ne}$$ Ne , $$\mathrm {CO}_2$$ CO 2 , and $$\mathrm {SF}_6$$ SF 6 gases, by measuring their photo ion-yield spectra at the BESSY II synchrotron facility simultaneously with the 1s– n p fluorescence emission of He-like ions produced in the Polar-X EBIT. Accurate ab initio calculations of transitions in these ions provide the basis of the calibration. While the $$\mathrm {CO}_2$$ CO 2 result agrees well with previous measurements, the $$\mathrm {SF}_6$$ SF 6 spectrum appears shifted by $$\sim $$ ∼ 0.5 eV, about twice the uncertainty of the earlier results. Our result for $$\mathrm {Ne}$$ Ne shows a large departure from earlier results, but may suffer from larger systematic effects than our other measurements. The molecular spectra agree well with our results of time-dependent density functional theory. We find that the statistical uncertainty allows calibrations in the desired range of 1–10 meV, however, systematic contributions still limit the uncertainty to $${\sim }$$ ∼ 40–100 meV, mainly due to the temporal stability of the monochromator energy scale. Combining our absolute calibration technique with a relative energy calibration technique such as photoelectron energy spectroscopy will be necessary to realize its full potential of achieving uncertainties as low as 1–10 meV. Graphical abstract

74 ATOMIC AND MOLECULAR PHYSICS↗