Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “blindness”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

Experimental Limit on Nonlinear State-Dependent Terms in Quantum Theory

Linear time evolution is one of the fundamental postulates of quantum theory. Past theoretical attempts to introduce nonlinearity into quantum evolution have violated causality. However, a recent theory has introduced nonlinear state-dependent terms in quantum field theory, preserving causality [D. E. Kaplan and S. Rajendran, Phys. Rev. D 105, 055002 (2022)]. We report the results of an experiment that searches for such terms. Our approach, inspired by the Everett many-worlds interpretation of quantum theory, correlates a binary macroscopic classical voltage with the outcome of a projective measurement of a quantum bit, prepared in a coherent superposition state. Measurement results are recorded in a bit string, which is used to control a voltage switch. Presence of a nonzero voltage reading in cases of no applied voltage is the experimental signature of a nonlinear state-dependent shift of the electromagnetic field operator. We implement blinded measurement and data analysis with three control bit strings. Control of systematic effects is realized by producing one of the control bit strings with a classical random-bit generator. The other two bit strings are generated by measurements performed on a superconducting qubit in an IBM Quantum processor and on a N 15 nuclear spin in a nitrogen-vacancy center in diamond. Our measurements find no evidence for electromagnetic quantum state-dependent nonlinearity. We set a bound on the parameter that quantifies this nonlinearity | ε γ | < 4.7 × 10 - 11 , at 90% confidence level.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Rare K 40 Decay with Implications for Fundamental Physics and Geochronology

Potassium-40 is a widespread, naturally occurring isotope whose radioactivity impacts subatomic rare-event searches, nuclear structure theory, and estimated geological ages. A predicted electron-capture decay directly to the ground state of argon-40 has never been observed. Here, the KDK (potassium decay) collaboration reports strong evidence of this rare decay mode. A blinded analysis reveals a nonzero ratio of intensities of ground-state electron-captures (I EC 0 ) over excited-state ones (I EC $\star$ ) of I EC 0 /I EC $\star$ = 0.0095 $^{stat}_{±}$ 0.0022 $^{sys}_{±}$ 0.0010 (68% C.L.), with the null hypothesis rejected at 4σ. In terms of branching ratio, this signal yields I EC 0 = 0.098 % $^{stat}_{±}$ 0.023 % $^{sys}_{±}$ 0.010 % , roughly half of the commonly used prediction, with consequences for various fields [L. Hariasz et al., companion paper, Phys. Rev. C 108, 014327 (2023)].

39 ≤ A ≤ 58↗

Resolving local structural motifs across the phase evolution of zinc titanates with computational x-ray absorption spectroscopy

Resolving the local structure motifs that characterize phase evolution as a function of composition is a key challenge in structure characterization of complex materials. Here, in this study, we combine first-principles simulations and x-ray absorption near-edge structures (XANES) analysis to gain insights into the structure evolution revealed by measurements across a combinatorial zinc titanate thin film, which was grown with smoothly varying composition over a wide range of the Ti:Zn ratio. Specifically, we propose a cluster blind-signal-separation (cBSS) method for XANES spectral analysis based on a library of the structures and spectra of representative local motifs. In addition to motifs from zinc titanate crystals, two types of Ti-defect models constructed in this study are key to the understanding of the structure characteristics in the Zn-rich region. The cBSS method makes use of both spectral clustering of the simulated site-XANES spectra library and the BSS procedure to construct high-fidelity spectral basis functions from an experimental spectral sequence. The method provides a rigorous measure of the spectral sensitivity and basis completeness. The results of the XANES analysis are corroborated with other experimental modalities, including x-ray diffraction and spectroscopic ellipsometry, to validate the cBSS method. The calculated motif weights resulting from fitting the XANES spectra with the cBSS basis probe the atomic structure characteristics of both crystalline and amorphous phases as a function of the Ti/Zn composition. The insights of the local structure motif evolution are pivotal to the understanding of the nonmonotonic trend in the optical gap, which may lead to potential applications through tuning the optical properties of zinc titanate. The workflow of the XANES spectral analysis developed in this work can be generalized to construct the structure-property relationship in a broad material space.

36 MATERIALS SCIENCE↗

Upper limit on the chiral magnetic effect in isobar collisions at the Relativistic Heavy-Ion Collider

The chiral magnetic effect (CME) is a phenomenon that arises from the QCD anomaly in the presence of an external magnetic field. The experimental search for its evidence has been one of the key goals of the physics program of the Relativistic Heavy-Ion Collider. The STAR Collaboration has previously presented the results of a blind analysis of isobar collisions ( Ru 44 96 + Ru 44 96 , Zr 40 96 + Zr 40 96 ) in the search for the CME. The isobar ratio ( Y ) of CME-sensitive observable, charge separation scaled by elliptic anisotropy, is close to but systematically larger than the inverse multiplicity ratio, the naive background baseline. This indicates the potential existence of a CME signal and the presence of remaining nonflow background due to two- and three-particle correlations, which are different between the isobars. In this postblind analysis, we estimate the contributions from those nonflow correlations as a background baseline to Y , utilizing the isobar data as well as Heavy Ion Jet Interaction Generator simulations. This baseline is found consistent with the isobar ratio measurement, and an upper limit of 10% at 95% confidence level is extracted for the CME fraction in the charge separation measurement in isobar collisions at s NN = 200 GeV. Published by the American Physical Society 2024

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Experimental search for the chiral magnetic effect in relativistic heavy-ion collisions: A perspective

The chiral magnetic effect (CME) refers to generation of the electric current along a magnetic field in a chirally imbalanced system of quarks. The latter is predicted by quantum chromodynamics to arise from quark interaction with nontrivial topological fluctuations of the vacuum gluonic field. The CME has been actively searched for in relativistic heavy-ion collisions, where such gluonic field fluctuations and a strong magnetic field are believed to be present. The CME-sensitive observables are unfortunately subject to a possibly large non-CME background, and firm conclusions on a CME observation have not yet been reached. In this perspective, we review the experimental status and progress in the CME search, from the initial measurements more than a decade ago to the dedicated program of isobar collisions in 2018 and the release of the isobar blind analysis result in 2022 to intriguing hints of a possible CME signal in Au + Au collisions, and discuss future prospects of a potential CME discovery in the anticipated high-statistic Au + Au collision data at the Relativistic Heavy-Ion Collider by 2025. We hope such a perspective will help sharpening our focus on the fundamental physics of the CME and steer its experimental search.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Model-independent measurement of the matter-radiation equality scale in DESI 2024

The peak of the matter power spectrum, known as the turnover (TO) scale, is determined by the horizon size at the time of matter-radiation equality. This scale can serve as a standard ruler, independent of other features in the matter power spectrum, such as baryon acoustic oscillations (BAO). Here, in this work, we present the first detection of the turnover in the galaxy autopower spectrum, utilizing the distribution of quasars and luminous red galaxies (LRG) measured by the Dark Energy Spectroscopic Instrument (DESI) during its first year of survey operations in a model-independent manner. To avoid confirmation bias, we first analyze the data using data blinding methods designed for the DESI baryon acoustic oscillation, redshift space distortion and scale-dependent bias signals. We measure the angle-averaged dilation distance 𝐷 V ⁡(𝑧 = 1.651) = (38.1 ± 2.5)⁢𝑟 H from the quasars and 𝐷 V ⁡(𝑧 = 0.733) = (21.8 ± 1.0)⁢𝑟 H from the LRG sample in units of the horizon 𝑟 H at the matter-radiation-equality epoch. Combining these two constraints and assuming a flat Λ⁢CDM model with three standard neutrino species, we can translate this into a constraint of Ω m ⁢ℎ 2 = 0.13⁢9$^{+0.036}_{−0.046}$. We can break the Ω m −𝐻 0 degeneracy with low-redshift distance measurements from type-Ia supernova (SN) data from Pantheon+, we obtain a sound-horizon free estimate of the Hubble-Lemaître parameter of 𝐻 0 = 65.2$^{+4.9}_{−6.2}$ km/s/Mpc, consistent with sound-horizon dependent DESI measurements. On the other hand, combining the DESI BAO and TO, we find a truly DESI-only measurement of 𝐻 0 = 74.0$^{+7.2}_{−3.5}$ km/s/Mpc, in line with DESI-only full-shape results where the sound-horizon scale is marginalized out. This discrepancy in 𝐻 0 can be reconciled in a 𝑤 0 ⁢𝑤 𝑎 ⁢ CDM cosmology, where the combination of DESI BAO and TO data yields 𝐻 0 = 66.5 ± 7.2 km/s/Mpc.

cosmological parameters↗

Iterative X-ray spectroscopic ptychography

Spectroscopic ptychography is a powerful technique to determine the chemical composition of a sample with high spatial resolution. In spectro-ptychography, a sample is rastered through a focused X-ray beam with varying photon energy so that a series of phaseless diffraction data are recorded. Each chemical component in the material under investigation has a characteristic absorption and phase contrast as a function of photon energy. Using a dictionary formed by the set of contrast functions of each energy for each chemical component, it is possible to obtain the chemical composition of the material from high-resolution multi-spectral images. This paper presents SPA (spectroscopic ptychography with alternating direction method of multipliers), a novel algorithm to iteratively solve the spectroscopic blind ptychography problem. First, a nonlinear spectro-ptychography model based on Poisson maximum likelihood is designed, and then the proposed method is constructed on the basis of fast iterative splitting operators. SPA can be used to retrieve spectral contrast when considering either a known or an incomplete (partially known) dictionary of reference spectra. By coupling the redundancy across different spectral measurements, the proposed algorithm can achieve higher reconstruction quality when compared with standard state-of-the-art two-step methods. It is demonstrated how SPA can recover accurate chemical maps from Poisson-noised measurements, and its enhanced robustness when reconstructing reduced-redundancy ptychography data using large scanning step sizes is shown.

47 OTHER INSTRUMENTATION↗

Crystal structure of N-terminally hexahistidine-tagged Onchocerca volvulus macrophage migration inhibitory factor-1

Onchocerca volvulus causes blindness, onchocerciasis, skin infections and devastating neurological diseases such as nodding syndrome. New treatments are needed because the currently used drug, ivermectin, is contraindicated in pregnant women and those co-infected with Loa loa . The Seattle Structural Genomics Center for Infectious Disease (SSGCID) produced, crystallized and determined the apo structure of N-terminally hexahistidine-tagged O. volvulus macrophage migration inhibitory factor-1 (His- Ov MIF-1). Ov MIF-1 is a possible drug target. His- Ov MIF-1 has a unique jellyfish-like structure with a prototypical macrophage migration inhibitory factor (MIF) trimer as the `head' and a unique C-terminal `tail'. Deleting the N-terminal tag reveals an Ov MIF-1 structure with a larger cavity than that observed in human MIF that can be targeted for drug repurposing and discovery. Removal of the tag will be necessary to determine the actual biological oligomer of Ov MIF-1 because size-exclusion chomatographic analysis of His- Ov MIF-1 suggests a monomer, while PISA analysis suggests a hexamer stabilized by the unique C-terminal tails.

Kimble, Amber D. (ORCID:0000000167851596)↗

The advancement of a technique using principal component analysis for the non-intrusive depth profiling of radioactive contamination

A non-intrusive technique using principal component analysis, to infer the depth of the fission fragment caesium-137, when it is buried under silica sand has been described. Using energy variances within different {gamma}-ray spectra, a complete depth model was produced for a single caesium-137 source buried under 1 mm depths ranging between 5-50 mm. This was achieved using a cadmium telluride detector and a bespoke phantom. In this paper we describe the advancement of the technique by further validating it using blind tests for applications outside of the laboratory, where not only the depth (z) but also the surface (x, y) location of {gamma}-ray emitting contamination is often poorly characterised. At present the technique has been tested at the point of maximum activity above the entrained {gamma}-ray emitting source (where the optimal x, y location is known). This is not usually practical in poorly characterized environments where the detector cannot be conveniently placed at such an optimal location to begin with and scanning at multiple points around the region of interest is often required. Using a uniform scanning time, the point of maximum intensity can be located by sampling in terms of total count rate, and converging on this optimal point of maximum intensity. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Passive neutron coincidence counting with plastic scintillators for the characterization of radioactive waste drums

The quantification of radioactive material is essential in the fields of safeguards, criticality control of nuclear processes, dismantling of nuclear facilities and components, or radioactive waste characterization. The Nuclear Measurement Laboratory (LMN) of CEA is involved in the development of time-correlated neutron detection techniques using plastic scintillators. Usually, 3He proportional counters are used for passive neutron coincidence counting owing to their high thermal neutron capture efficiency and gamma insensitivity. However, the global {sup 3}He shortage in the past few years has made these detectors extremely expensive. In addition, contrary to {sup 3}He counters for which a few tens of microseconds are needed to thermalize fast neutrons, in view to maximize the {sup 3}He(n,p){sup 3}H capture cross section, plastic scintillators are based on elastic scattering and therefore the light signal is formed within a few nanoseconds, correlated pulses being detected within a few dozen- or hundred nanoseconds. This time span reflects fission particles time of flight, which allows reducing accordingly the duration of the coincidence gate and thus the rate of random coincidences, which may totally blind fission coincidences when using {sup 3}He counters in case of a high (α,n) reaction rate. However, plastic scintillators are very sensitive to gamma rays, requiring the use of a thick metallic shield to reduce the corresponding background. Cross talk between detectors is also a major issue, which consists on the detection of one particle by several detectors due to elastic or inelastic scattering, leading to true but undesired coincidences. Data analysis algorithms are tested to minimize cross-talk in simultaneously activated detectors. The distinction between useful fission coincidences and the correlated background due to cross-talk, (α,n) and induced (n,2n) or (n,n'γ) reactions, is achieved by measuring 3-fold coincidences. The performances of a passive neutron coincidence counting system for radioactive waste drums using plastic scintillators have been studied using the Monte Carlo radiation transport code MCNPX-PoliMi v2.0 coupled to data processing algorithms developed with ROOT data analysis software. In addition to the correlated background, accidental coincidences are taken into account in the simulation by randomly merging pulses from different calculations with fission and (α,n) sources. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Physics-Aligned Multi-Domain Machine Learning Framework for Time-Localised Diagnosis of Power Electronics Faults

This paper presents a physics-aligned framework for fault diagnosis in multi-phase power-electronic systems using cycle-synchronous windowing and multi-domain features derived from Fourier, wavelet, and Hilbert–Huang representations. While both logistic regression and multilayer perceptron (MLP) models achieve perfect performance under standard evaluation, blind unseen testing reveals a critical failure in a baseline MLP. This is shown to arise from model selection based on validation accuracy. Using validation-loss-based selection restores correct unseen performance and improves confidence. Feature ablation shows that Fourier and wavelet features dominate, while computational analysis indicates that feature extraction, particularly HHT, governs runtime.

Kumar, Praveen [ORNL] (ORCID:0000000291877857)↗

Design and Implementation of an Underlay Control Channel for Cognitive Radios

Implementation of any cognitive radio network requires an effective control channel that can operate under various modes of activity from the primary users. This paper reports the design and implementation of a filter bank multicarrier spread spectrum (FBMC-SS) system for use as the control channel in cognitive radio networks. The proposed design is based on a filtered multitone (FMT) implementation. Carrier and timing acquisition and tracking methods as well as a blind channel estimation method are developed for the proposed control channel. We also report an implementation of the proposed FBMC-SS system on a hardware platform; a FlexRIO FPGA module from National Instruments.

99 GENERAL AND MISCELLANEOUS↗

A Dimensionally Aligned Signal Projection for Classification of Unintended Radiated Emissions

Characterization of unintended radiated emissions (URE) from electronic devices plays an important role in many research areas from electromagnetic interference to nonintrusive load monitoring to information system security. URE can provide insights for applications ranging from load disaggregation and energy efficiency to condition-based maintenance of equipment-based upon detected fault conditions. URE characterization often requires subject matter expertise to tailor transforms and feature extractors for the specific electrical devices of interest. We present a novel approach, named dimensionally aligned signal projection (DASP), for projecting aligned signal characteristics that are inherent to the physical implementation of many commercial electronic devices. These projections minimize the need for an intimate understanding of the underlying physical circuitry and significantly reduce the number of features required for signal classification. We present three possible DASP algorithms that leverage frequency harmonics, modulation alignments, and frequency peak spacings, along with a two-dimensional image manipulation method for statistical feature extraction. To demonstrate the ability of DASP to generate relevant features from URE, we measured the conducted URE from 14 residential electronic devices using a 2 MS/s collection system. Furthermore, a linear discriminant analysis classifier was trained using DASP generated features and was blind tested resulting in a greater than 90% classification accuracy for each of the DASP algorithms and an accuracy of 99.1% when DASP features are used in combination. Furthermore, we show that a rank reduced feature set of the combined DASP algorithms provides a 98.9% classification accuracy with only three features and outperforms a set of spectral features in terms of general classification as well as applicability across a broad number of devices.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Connect the Dots: In Situ 4-D Seismic Monitoring of CO 2 Storage With Spatio-Temporal CNNs

4-D seismic imaging has been widely used in CO 2 sequestration projects to monitor the fluid flow in the volumetric subsurface region that is not sampled by wells. Ideally, real-time monitoring and near-future forecasting would provide site operators with great insights to understand the dynamics of the subsurface reservoir and assess any potential risks. However, due to obstacles such as high deployment cost, availability of acquisition equipment, exclusion zones around surface structures, only very sparse seismic imaging data can be obtained during monitoring. That leads to an unavoidable and growing knowledge gap over time. The operator needs to understand the fluid flow throughout the project lifetime and the seismic data are only available at a limited number of times. This is insufficient for understanding reservoir behavior. To overcome those challenges, we have developed spatio-temporal neural-network-based models that can produce high-fidelity interpolated or extrapolated images effectively and efficiently. Specifically, our models are built on an autoencoder, and incorporate the long short-term memory (LSTM) structure with a new loss function regularized by optical flow. We validate the performance of our models using real 4-D post-stack seismic imaging data acquired at the Sleipner CO 2 sequestration field. We employ two different strategies in evaluating our models. Numerically, we compare our models with different baseline approaches using classic pixel-based metrics. We also conduct a blind survey and collect a total of 20 responses from domain experts to evaluate the quality of data generated by our models. Finally, via both numerical and expert evaluation, we conclude that our models can produce high-quality 2-D/3-D seismic imaging data at a reasonable cost, offering the possibility of real-time monitoring or even near-future forecasting of the CO 2 storage reservoir.

4-D seismic imaging↗

Non-Intrusive Appliance Identification with Appliance-Specific Networks

The problem of noninstrusive load monitoring (NILM) is usually formulated as a single-channel blind source separation task, whose successful solution enable fast and convenient load identification and energy disaggregation. When applied at test time, NILM algorithms aim to identify the operating characteristics of individual appliances from an aggregate power measurement of the entire house. Recent advances in deep learning gave rise to many methods that mostly focus on learning a direct mapping from aggregate measurement to individual appliance power. However, these methods are not only computationally expensive, but they often suffer from overfitting and do not generalize very well. In this article, we propose a novel NILM method that leverages advances in statistical learning that have not been properly applied in this domain before. The proposed method consists of three stages: first, a Bayesian nonparametric learning-based approach for appliance state extraction; second, synthetic minority oversampling technique for data augmentation and mitigating the heavy imbalance in switching events; and third, appliance-specific lightweight long short-term memory networks for status classification for each appliance. Here, we adopt a “differential” input (the difference before and after the switching event) to reduce the complexity of network training and make the proposed method robust to multiappliance switching events. Experiments are conducted to demonstrate the effectiveness of the proposed method, achieving superior performance when compared to recent methods. An ablation study is conducted to demonstrate the effectiveness of each module of our method. Finally, we investigate the quality of generated synthetic samples.

42 ENGINEERING↗

A Measurement of the Scintillation Light Yield in CD4 Using a Photosensitive GEM Detector

The absolute photon yield of scintillation light produced by highly ionizing particles in pure CF{sub 4} has been measured using a photosensitive Gas Electron Multiplier (GEM) detector. The detector consists of two standard GEMs and a CsI coated GEM which acts as a photocathode that is sensitive to the 160 nm scintillation light produced in CF{sub 4}. The light yield was determined in terms of the number of scintillation photons emitted into a 4{pi} solid angle produced per MeV of energy deposited in the gas by a 5.5 MeV alpha particle and found to be 314 {+-} 15 photons per MeV. The quantum yield was determined using a fitting method to determine the number of photoelectrons from the measured pulse height distribution, and by an independent method using the measured gain of the GEM detector. The effect of scintillation light in CF{sub 4} on the performance of Cherenkov detectors, such as the PHENIX Hadron Blind Detector (HBD) at RHIC, is also discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Performance of a Quintuple-GEM Based RICHDetector Prototype

Cerenkov technology is often the optimal choice for particle identification in high energy particle collision applications. Typically, the most challenging regime is at high pseudorapidity (forward) where particle identification must perform well at high laboratory momenta. For the upcoming electron ion collider (EIC), the physics goals require hadron (π, K, p) identification up to ~50 GeV/c. In this region Cerenkov ring-imaging (RICH) is the most viable solution. The speed of light in a radiator medium is inversely proportional to the refractive index. Hence, for particle identification (PID) reaching out to high momenta a small index of refraction is required. Unfortunately, the lowest indices of refraction also result in the lowest light yield ([(dNγ)/dx] ∝ sin2(θC)) driving up the radiator length and thereby the overall detector cost. In this paper we report on a successful test of a compact RICH detector (1 meter radiator) capable of delivering in excess of 10 photoelectrons per ring with a low index radiator gas (CF4). The detector concept is a natural extension of the PHENIX hadron-blind detector (HBD) achieved by adding focusing capability at low wavelength and adequate gain for high efficiency detection of single-electron induced avalanches. Our results indicate that this technology is indeed a viable choice in the forward direction of the EIC. The setup and results are described within.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Diagnosis of Performance Faults in LargeScale MPI Applications via Probabilistic Progress-Dependence Inference

Debugging large-scale parallel applications is challenging. Most existing techniques provide little information about failure root causes. Further, most debuggers significantly slow down program execution, and run sluggishly with massively parallel applications. This paper presents a novel technique that scalably infers the tasks in a parallel program on which a failure occurred, as well as the code in which it originated. Our technique combines scalable runtime analysis with static analysis to determine the least-progressed task(s) and to identify the code lines at which the failure arose. We present a novel algorithm that infers probabilistically progress dependence among MPI tasks using a globally constructed Markov model that represents tasks' control-flow behavior. In comparison to previous work, our algorithm infers more precisely the least-progressed task. Further, we combine this technique with static backward slicing analysis, further isolating the code responsible for the current state. A blind study demonstrates that our technique isolates the root cause of a concurrency bug in a molecular dynamics simulation, which only manifests itself at 7,996 tasks or more. We extensively evaluate fault coverage of our technique via fault injections in 10 HPC benchmarks and show that our analysis takes less than a few seconds on thousands of parallel tasks.

97 MATHEMATICS AND COMPUTING↗