Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “WHEELS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

Coarse spectral characterization of warm x-rays at the Z facility using a filtered thermoluminescent dosimeter array

A new collimated filtered thermoluminescent dosimeter (TLD) array has been developed at the Z facility to characterize warm x-rays (hν > 10 keV) produced by Z pinch radiation sources. This array includes a Kapton debris shield assembly to protect the TLDs from the source debris, a collimator array to limit the field of view of the TLDs to the source region, a filter wheel containing filters of aluminum, copper and tungsten up to 3 mm thick to independently filter each TLD, and a hermetically sealed cassette containing the TLDs as well as tungsten shielding on the sides and back of the array to minimize scattered radiation reaching the TLDs. Here experimental results from a krypton gas puff and silver wire array shot are analyzed using two different functional forms of the energy spectrum to demonstrate the ability of this diagnostic to consistently extend the upper end of the x-ray spectrum characterization from ~50 keV to >1 MeV.

47 OTHER INSTRUMENTATION↗

Preparation of highly pure α-MnBi phase via melt-spinning

High concentration of the magnetically hard α phase in the Mn-Bi alloys is important for the development of these alloys as rare-earth-free permanent magnets. Among several explored manufacturing methods, melt-spinning followed by annealing is known to be suitable of producing the most pure α structure. In this work, a series of melt-spun Mn 100-x Bi x alloys was prepared with x = 43 – 51 at a wheel speed of 67 m/s by ejecting the alloys through orifices 0.17 mm and 0.27 mm in diameter. The smaller orifice diameter favored formation of an amorphous phase in the as-spun alloys as well as a higher saturation magnetization M s in the alloys subsequently annealed at 300 °C. Although the most pure, 98 vol.%, α phase was obtained for the off-stoichiometric Mn 55 Bi 45 composition, the M s of this material was lowered, possibly because the excess Mn atoms induced antiferromagnetic coupling in the α phase. The highest M s of 78 emu/g was obtained for a composition closer to the Mn 50 Bi 50 stoichiometry, despite the slightly lower purity of α phase. Furthermore, evolution of the room-temperature coercivity with the formation of the α phase in the melt-spun alloys was studied for the Mn 55 Bi 45 ribbons compacted at 275 °C; the coercivity values of around 1 kOe obtained through this simple procedure are not sufficient for permanent magnet applications.

36 MATERIALS SCIENCE↗

Further Investigation of Surface Velocity Measurements for Material Characterization in Laser Shockwave Experiments

Further investigation of surface velocity measurements for material characterization in laser shockwave experiments James A. Smith, Jeffrey M. Lacy, Clark L. Scott, Bradley C. Benefiel Idaho National Laboratory, Idaho Falls ID Daniel Levesque, Jean-Pierre Monchalin and Martin Lord, National Research Council Canada, Boucherville, QC, Canada ---As part of the US High Performance Research Reactor program, a laser shockwave system is being developed by the Idaho National Laboratory (INL) to characterize interface strength in innovative plate fuel for research reactors around the world. The INL has been working with National Research Council Canada (NRC) on this project for the last five years. One of the concerns is the difficulty of calibrating and standardizing the laser shock technique. The generation of a stress wave by the laser impinging on the plate surface is dependent on the surface preparation, temporal and spatial power distribution of the laser spot, and material properties of the plate. Thus the resulting back surface velocity used to measure the time-varying stress field within the plate is difficult to reproduce across different measurement systems. ---A recent analytical study and testing support the use of the Hugoniot Elastic Limit (HEL) in materials as a robust and simple benchmark to compare stresses generated by different laser shock systems [1]. Using a non-contact laser velocimeter based on a solid Fabry-Perot etalon, the systems at NRC and INL showed that the velocity reached at the HEL is consistent, independent of the laser power used. In this work, the laser velocimeter of the NRC system is tested against a fast rotating wheel to verify accuracy and determine best operating conditions. A round robin test between the two laser shock systems on plates of different Al alloys is presented that shows the correct classification of the Al alloys based on the HEL as well as determining the bias between the systems. Also the effects of some setup parameters on other characteristics of the surface velocity and corresponding stress wave are discussed. 1. J.A. Smith, J.M. Lacy, D. Levesque, J.-P. Monchalin and M. Lord, "Use of the Hugoniot elastic limit in laser shockwave experiments to relate velocity measurements, 42nd Annual Review of Progress in Quantitative Nondestructive Evaluation, AIP Conf. Proc. 1706, pp. 080005-1-080005-10, 2016.

36 MATERIALS SCIENCE↗

Initial results and designs of dual-filter and plenoptic imaging for high-temperature plasmas

Mass injection has found new applications in magnetic fusion including edge-localized-mode control. Better understanding of injected-mass-plasma interactions requires spatially and temporally resolved diagnostics that can characterize the dynamics of the mass interactions with plasmas. Fast imaging can be used to characterize the ionization dynamics such as the propagation of the ionization front, which moves at the thermal sound or higher speed, and mixing of the neutral atoms with the ambient plasma. Multi-wavelength spectral imaging is promising since different parts of the plasma give different spectral signatures. Here in this paper we describe a dual-spectral imaging technique based on a monochromatic camera sensor and filters with two passing optical wavelengths. The method is shown to improve image contrast, and it compares favorably with alternatives such as color cameras and methods using a filter wheel. Further improvements through relative filter area ratios and plenoptic imaging are possible. Finally, the initial results from EAST and plenoptic imaging are also included.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-ray analysis methods for sources from self-modulated laser wakefield acceleration driven by picosecond lasers

A versatile set of methods for analyzing x-ray energy spectra and photon flux has been developed for laser plasma accelerator experiments driven by picosecond lasers. Forward fit provides extrapolated broad energy spectrum measurements, while Ross pair and differential average transmission analysis provide directly measured data points using a particular diagnostic. Combining these methods allows the measurement of x-ray energy spectra with improved confidence. We apply here the methods to three diagnostics (filter wheel, stacked image plate spectrometer, and step wedge), each sensitive to a different region of x-ray energies (<40 keV, 35–100 keV, and 60–1000 keV, respectively), to characterize the analysis methods using laser-driven bremsstrahlung x-rays. We then apply the methods to measure three x-ray mechanisms, betatron, inverse Compton scattering, and bremsstrahlung, driven by a laser plasma accelerator. The analysis results in the measurement of x-ray energy spectra ranging from 10 keV to 1 MeV with peak flux greater than 10 10 photons/keV/Sr. The combined analysis methods provide a robust tool to accurately measure broadband x-ray sources (keV to MeV) driven by laser plasma acceleration with picosecond, kilojoule-class lasers.

47 OTHER INSTRUMENTATION↗

The fast camera (Fastcam) imaging diagnostic systems on the DIII-D tokamak

Two camera systems are installed on the DIII-D tokamak at the toroidal positions of 90° (90° system) and 225° (225° system), respectively. The cameras have two types of relay optics, namely, a coherent optical fiber bundle and a periscope system. The periscope system provides absolute intensity calibration stability while sacrificing resolution (10 lp/mm), while the fiber system provides high resolution (16 lp/mm) while sacrificing calibration stability. The periscope is available only for the 90° system. The optics of the 225° system were designed for view stability, repeatability, and easy maintenance. The cameras are located inside optimized neutron, x ray and magnetic shielding in order to reduce electronics damage, reboots, and magnetic and neutron interference, increasing the overall system reliability. An automated filter wheel, providing remote filter change, allows for remote wavelength selection. A software suite automates camera acquisition and data storage, allowing for remote operation and reduced operator involvement. System metadata is used to streamline the data analysis workflow, particularly for intensity calibration. Here, the spatial calibration uses multiple observable wall features, resulting in a reconstruction accuracy ≤2 cm.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Tangential extreme ultraviolet and soft x-ray diagnostic system for time-resolved temperature measurement on the High Beta Tokamak-Extended Pulse

The High Beta Tokamak-Extended Pulse has recently incorporated a tangential multi-energy extreme ultraviolet and soft x-ray diagnostic system. This system enables measurements of the electron temperature and the examination of mode dynamics within the tokamak. While other systems have been built for poloidal views over similar temperature ranges, this is the first multi-energy tangential-view system designed to work in a temperature range below 200 eV in a tokamak. To facilitate these measurements, a filter wheel comprising five distinct groups of dual-filters has been developed and implemented. By employing a combination of 0.1 μm aluminum and 0.2 μm titanium filters, the system allows estimation of electron temperature profiles through reconstruction of the emission profile using the standard “double-foil” technique. The influence of impurities and filter oxide layers on measurement outcomes is examined. Results reveal that, while the absolute electron temperature values may exhibit some deviations, key characteristics like the electron temperature profile shape and inversion radius during sawtooth events remain consistent. This consistency confirms the system’s suitability for core plasma studies. This system has proven effective in detecting and analyzing internal magnetohydrodynamic phenomena, such as sawteeth.

Instruments & Instrumentation↗

Adjustable collimation for dark-field proton radiography contrast enhancement

A dark-field imaging condition established through pre- and post-object beam collimation has been tested for a variety of different settings at the proton radiography facility (pRad) at Los Alamos National Laboratory. This technique facilitates imaging of thin samples and materials with small areal density changes with 800 MeV protons that would otherwise appear nearly transparent for high energy protons. In the configuration that was examined, the pre-object (upstream) collimator is utilized to remove protons with large scattering angles prior to the target object. The post-object collimation entails a combination of a conventional collimator, which eliminates protons with large scattering angles after target interaction, and an inverse collimator. The inverse collimator removes unscattered protons traveling on the beam axis and those with smaller scattering angles up to a desired angle. This establishes a dark-field condition by permitting solely protons that exhibit scattering angles from target interaction within a designated range to contribute to the image. This study explores the potential of combining different sized collimators for pre- and post-object collimation. The objective is to optimize contrast for a range of samples with minimal areal density variations. A series of dark-field conditions are explored employing a remote-controlled collimator wheel and the contrast-to-noise ratio, spatial resolution, and proton transmission are compared for those combinations. It is found that the contrast-to-noise ratio can be substantially enhanced for thin samples and low areal density objects, thereby facilitating capturing high-contrast images of objects that were previously invisible to high energy protons.

43 PARTICLE ACCELERATORS↗

Untangling the sequence of events during the S 2 → S 3 transition in photosystem II and implications for the water oxidation mechanism

In oxygenic photosynthesis, light-driven oxidation of water to molecular oxygen is carried out by the oxygen-evolving complex (OEC) in photosystem II (PS II). Recently, we reported the room-temperature structures of PS II in the four (semi)stable S-states, S 1 , S 2 , S 3 , and S 0 , showing that a water molecule is inserted during the S 2 → S 3 transition, as a new bridging O(H)-ligand between Mn1 and Ca. To understand the sequence of events leading to the formation of this last stable intermediate state before O 2 formation, we recorded diffraction and Mn X-ray emission spectroscopy (XES) data at several time points during the S 2 → S 3 transition. At the electron acceptor site, changes due to the two-electron redox chemistry at the quinones, Q A and Q B , are observed. At the donor site, tyrosine Y Z and His190 H-bonded to it move by 50 µs after the second flash, and Glu189 moves away from Ca. This is followed by Mn1 and Mn4 moving apart, and the insertion of O X (H) at the open coordination site of Mn1. This water, possibly a ligand of Ca, could be supplied via a “water wheel”-like arrangement of five waters next to the OEC that is connected by a large channel to the bulk solvent. XES spectra show that Mn oxidation (τ of ∼350 µs) during the S 2 → S 3 transition mirrors the appearance of O X electron density. This indicates that the oxidation state change and the insertion of water as a bridging atom between Mn1 and Ca are highly correlated.

59 BASIC BIOLOGICAL SCIENCES↗

Outsourced hearing in an orb-weaving spider that uses its web as an auditory sensor

Hearing is a fundamental sense of many animals, including all mammals, birds, some reptiles, amphibians, fish, and arthropods. The auditory organs of these animals are extremely diverse in anatomy after hundreds of millions of years of evolution, yet all are made up of cellular tissue and are morphologically part of the bodies of animals. Here, we show that hearing in the orb-weaving spider Larinioides sclopetarius is not constrained by the organism’s body but is extended through outsourcing hearing to its extended phenotype, the proteinaceous, self-manufactured orb web. We find that the wispy, wheel-shaped orb web acts as a hyperacute acoustic antenna to capture the sound-induced air particle movements that approach the maximum physical efficiency better than the acoustic responsivity of all previously known eardrums. By sensing the motion of web threads, the spider remotely detects and localizes the source of an incoming airborne acoustic wave, such as those emitted by approaching prey or predators. By outsourcing its acoustic sensors to its web, the spider is released from body size constraints and permits the araneid spider to increase its sound-sensitive surface area enormously, up to 10,000 times greater than the spider itself. The spider also enables the flexibility to functionally adjust and regularly regenerate its external "eardrum" according to its needs. The outsourcing and supersizing of auditory function in spiders provides unique features for studying extended and regenerative sensing and designing novel acoustic flow detectors for precise fluid dynamic measurement and manipulation.

60 APPLIED LIFE SCIENCES↗

Structural insights into plasmalemma vesicle-associated protein (PLVAP): Implications for vascular endothelial diaphragms and fenestrae

In many organs, small openings across capillary endothelial cells (ECs) allow the diffusion of low–molecular weight compounds and small proteins between the blood and tissue spaces. These openings contain a diaphragm composed of radially arranged fibers, and current evidence suggests that a single-span type II transmembrane protein, plasmalemma vesicle-associated protein-1 (PLVAP), constitutes these fibers. Here, we present the three-dimensional crystal structure of an 89-amino acid segment of the PLVAP extracellular domain (ECD) and show that it adopts a parallel dimeric alpha-helical coiled-coil configuration with five interchain disulfide bonds. The structure was solved using single-wavelength anomalous diffraction from sulfur-containing residues (sulfur SAD) to generate phase information. Biochemical and circular dichroism (CD) experiments show that a second PLVAP ECD segment also has a parallel dimeric alpha-helical configuration—presumably a coiled coil—held together with interchain disulfide bonds. Overall, ~2/3 of the ~390 amino acids within the PLVAP ECD adopt a helical configuration, as determined by CD. We also determined the sequence and epitope of MECA-32, an anti-PLVAP antibody. Taken together, these data lend strong support to the model of capillary diaphragms formulated by Tse and Stan in which approximately ten PLVAP dimers are arranged within each 60- to 80-nm-diameter opening like the spokes of a bicycle wheel. Passage of molecules through the wedge-shaped pores is presumably determined both by the length of PLVAP—i.e., the long dimension of the pore—and by the chemical properties of amino acid side chains and N-linked glycans on the solvent-accessible faces of PLVAP.

59 BASIC BIOLOGICAL SCIENCES↗

Wear evaluation of high interstitial stainless steel

A new series of high nitrogen-carbon manganese stainless steel alloys are studied for their wear resistance. High nitrogen and carbon concentrations were obtained by melting elemental iron-chromium-manganese (several with minor alloy additions of nickel, silicon, and molybdenum) in a nitrogen atmosphere and adding elemental graphite. The improvement in material properties (hardness and strength) with increasing nitrogen and carbon interstitial concentration was consistent with previously reported improvements in similar material properties alloyed with nitrogen only. Wear tests included: scratch, pin-on-disk, sand-rubber-wheel, impeller, and jet erosion. Additions of interstitial nitrogen and carbon as well as interstitial nitrogen and carbide precipitates were found to greatly improve material properties. In general, with increasing nitrogen and carbon concentrations, strength, hardness, and wear resistance increased.

36 MATERIALS SCIENCE↗

CCD Photometry of bright stars using objective wire mesh

Obtaining accurate photometry of bright stars from the ground remains problematic due to the danger of overexposing the target and/or the lack of suitable nearby comparison stars. The century-old method of using objective wire mesh to produce multiple stellar images seems promising for the precise CCD photometry of such stars. Furthermore, our tests on β Cep and its comparison star, differing by 5 mag, are very encouraging. Using a CCD camera and a 20 cm telescope with the objective covered by a plastic wire mesh, in poor weather conditions, we obtained differential photometry with a precision of 4.5 mmag per two minute exposure. Our technique is flexible and may be tuned to cover a range as big as 6-8 mag. We discuss the possibility of installing a wire mesh directly in the filter wheel.

79 ASTRONOMY AND ASTROPHYSICS↗

BROADBAND TRANSMISSION SPECTROSCOPY OF THE SUPER-EARTH GJ 1214b SUGGESTS A LOW MEAN MOLECULAR WEIGHT ATMOSPHERE

We use the Wide-field Infrared Camera (WIRCam) on the Canada-France-Hawaii Telescope to observe four transits of the super-Earth planet GJ 1214b in the near-infrared. For each transit, we observe GJ 1214 in two bands nearly simultaneously by rapidly switching the WIRCam filter wheel back and forth for the duration of the observations. By combining all our J-band ({approx}1.25 {mu}m) observations we find a transit depth, analogous to the planet-to-star radius ratio squared, in this band of (R{sub PJ} /R{sub *}){sup 2} = (1.338 {+-} 0.013)%-a value consistent with the optical transit depth reported by Charbonneau and collaborators. However, our best-fit combined K{sub s}-band ({approx}2.15 {mu}m) transit depth is deeper: (R{sub PKs} /R{sub *}){sup 2} = (1.438 {+-} 0.019)%. Formally, our K{sub s}-band transits are deeper than the J-band transits observed simultaneously by a factor of (R{sub PKs} /R{sub PJ}){sup 2} = 1.072 {+-} 0.018-a 4{sigma} discrepancy. The most straightforward explanation for our deeper K{sub s}-band transit depth is a spectral absorption feature from the limb of the atmosphere of the planet; for the spectral absorption feature to be this prominent, the atmosphere of GJ 1214b must have a large-scale height and a low mean molecular weight. That is, its atmosphere would have to be hydrogen/helium dominated and this planet would be better described as a mini-Neptune. However, recently published observations from 0.78 to 1.0 {mu}m, by Bean and collaborators, show a lack of spectral features and transit depths consistent with those obtained by Charbonneau and collaborators. The most likely atmospheric composition for GJ 1214b that arises from combining all these observations is less clear; if the atmosphere of GJ 1214b is hydrogen/helium dominated, then it must have either a haze layer that is obscuring transit-depth differences at shorter wavelengths or significantly different spectral features from what current models predict. Our observations disfavor a water-world composition, but such a composition will remain a possibility for GJ 1214b until observations reconfirm our deeper K{sub s}-band transit depth or detect features at other wavelengths.

79 ASTRONOMY AND ASTROPHYSICS↗

K2P{sup 2}—A photometry pipeline for the K2 mission

With the loss of a second reaction wheel, resulting in the inability to point continuously and stably at the same field of view, the NASA Kepler satellite recently entered a new mode of observation known as the K2 mission. The data from this redesigned mission present a specific challenge; the targets systematically drift in position on an ∼6 hr timescale, inducing a significant instrumental signal in the photometric time series—this greatly impacts the ability to detect planetary signals and perform asteroseismic analysis. Here we detail our version of a reduction pipeline for K2 target pixel data, which automatically defines masks for all targets in a given frame; extracts the target’s flux and position time series; corrects the time series based on the apparent movement on the CCD (either in 1D or 2D), combined with the correction of instrumental and/or planetary signals via the Kepler Asteroseismic Science Operations Center (KASOC) filter, thus rendering the time series ready for asteroseismic analysis; computes power spectra for all targets; and identifies potential contaminations between targets. From a test of our pipeline on a sample of targets from the K2 campaign 0, the recovery of data for multiple targets increases the amount of potential light curves by a factor of ⩾10. Our pipeline could be applied to the upcoming TESS and PLATO 2.0 missions.

79 ASTRONOMY AND ASTROPHYSICS↗

Neutron-Diffraction Evidence for the Ferrimagnetic Ground State of a Molecule-Based Magnet with Weakly Coupled Sublattices

The diruthenium compound [Ru2(O2CMe)4]3[Cr(CN)6] contains two weakly coupled, ferrimag- netically ordered sublattices occupying the same volume. The magnetic field Hc 800 Oe required to align the two sublattice moments is proportional to the antiferromagnetic dipolar interaction Kc B Hc 5 10 3 meV between sublattices. Powder neutron-diffraction measurements on a deuterated sample reveal that the sublattice moments are restricted by the anisotropy of the diruthenium paddle-wheel complexes to the cubic diagonals. Those measurements also suggest that the quantum corrections to the ground state are significant.

Fishman, Randy Scott↗

iSHELL: a 1–5 micron R = 80,000 Immersion Grating Spectrograph for the NASA Infrared Telescope Facility

iSHELL is a 1.06–5.3 μm high spectral resolution spectrograph built for the 3.2 m NASA Infrared Telescope Facility (IRTF) on Maunakea, Hawaii. Dispersion is accomplished with a silicon immersion grating in order to keep the instrument small enough to be mounted at the Cassegrain focus of the telescope. The white pupil spectrograph produces resolving powers of up to about R ≡ λ/δλ = 80,000 (0."375 slit). Cross-dispersing gratings mounted in a tiltable mechanism allow observers to select different wavelength ranges and, in combination with a slit wheel and Dekker mechanism, slit widths ranging from 0."375 to 4."0 and slit lengths ranging from 5" to 25". One Teledyne 2048 × 2048 HAWAII-2RG array is used in the spectrograph, and one Raytheon 512 × 512 Aladdin 2 array is used in a 1–5 μm slit viewer for object acquisition, guiding, and scientific imaging. iSHELL has been in productive regular use on IRTF since first light in 2016 September. In this paper we discuss details of the science case, design, construction and astronomical use of iSHELL.

79 ASTRONOMY AND ASTROPHYSICS↗

High rate studies of the ATLAS sTGC detector and optimization of the filter circuit on the input of the front-end amplifier

Abstract The Large Hadron Collider (LHC) at CERN is expected to be upgraded to the High-Luminosity LHC (HL-LHC) by 2029 and achieve instantaneous luminosity around 5–7.5 × 10 34 cm -2 s -1 . This represents a more than 3–4 fold increase in the instantaneous luminosity compared to what has been achieved in Run 2. The New Small Wheel (NSW) upgrade is designed to be able to operate efficiently in this high background rate environment. In this article, we summarize multiple performance studies of the small-strip Thin Gap Chamber (sTGC) at high rate using nearly final front-end electronics. We demonstrate that the efficiency versus rate distribution can be well described by an exponential decay with electronics dead-time being the primary cause of loss of efficiency at high rate. We then demonstrate several methods that can decrease the electronics dead-time and therefore minimize efficiency loss. One such method is to install either a pi-network input filter or pull-up resistor to minimize the charge input into the amplifier. We optimized the pi-network capacitance and pull-up resistor resistance using the results from our measurements. The results shown here were not only critical to finalizing the components on the front-end board, but also are critical for setting the optimal operating parameters of the sTGC detector and electronics in the ATLAS cavern.

Instruments & Instrumentation↗