Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TIME SIGNAL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

Suppressing interfering scattered signals in swept-frequency radar measurements by using frequency domain Wiener filtering

A novel approach to the reduction of scattered, interfering signals that corrupt measurements of the signal backscattered from radar targets of interest is being developed. It is being explored with sphere measurements in an indoor microwave radar range. This method is based on the concept of Wiener filtering (which minimizes the difference between the signal plus noise and the desired signal in the time domain). In contrast to the traditional Wiener filter, in which the time domain error between two sequences are minimized, the approach reported uses the frequency domain phasor amplitudes of a swept frequency signal. It minimizes the difference (least-mean-square-magnitude) between the signal-plus-noise and the signal complex phasors, across the entire spectrum.

Weissman, David E.↗

Functional Near Infrared Spectroscopy: Watching the Brain in Flight

Functional Near Infrared Spectroscopy (fNIRS) is an emerging neurological sensing technique applicable to optimizing human performance in transportation operations, such as commercial aviation. Cognitive state can be determined via pattern classification of functional activations measured with fNIRS. Operational application calls for further development of algorithms and filters for dynamic artifact removal. The concept of using the frequency domain phase shift signal to tune a Kalman filter is introduced to improve the quality of fNIRS signals in real-time. Hemoglobin concentration and phase shift traces were simulated for four different types of motion artifact to demonstrate the filter. Unwanted signal was reduced by at least 43%, and the contrast of the filtered oxygenated hemoglobin signal was increased by more than 100% overall. This filtering method is a good candidate for qualifying fNIRS signals in real time without auxiliary sensors.

Harrivel, Angela↗

Method for conducting nonlinear electrochemical impedance spectroscopy

A method for conducting nonlinear electrochemical impedance spectroscopy. The method includes quantifying the nonlinear response of an electrochemical system by measuring higher-order current or voltage harmonics generated by moderate-amplitude sinusoidal current or voltage perturbations. The method involves acquisition of the response signal followed by time apodization and fast Fourier transformation of the data into the frequency domain, where the magnitude and phase of each harmonic signal can be readily quantified. The method can be implemented on a computer as a software program.

25 ENERGY STORAGE↗

A comprehensive guide to CAN IDS data and introduction of the ROAD dataset

Although ubiquitous in modern vehicles, Controller Area Networks (CANs) lack basic security properties and are easily exploitable. A rapidly growing field of CAN security research has emerged that seeks to detect intrusions or anomalies on CANs. Producing vehicular CAN data with a variety of intrusions is a difficult task for most researchers as it requires expensive assets and deep expertise. To illuminate this task, we introduce the first comprehensive guide to the existing open CAN intrusion detection system (IDS) datasets. We categorize attacks on CANs including fabrication (adding frames, e.g., flooding or targeting and ID), suspension (removing an ID’s frames), and masquerade attacks (spoofed frames sent in lieu of suspended ones). We provide a quality analysis of each dataset; an enumeration of each datasets’ attacks, benefits, and drawbacks; categorization as real vs. simulated CAN data and real vs. simulated attacks; whether the data is raw CAN data or signal-translated; number of vehicles/CANs; quantity in terms of time; and finally a suggested use case of each dataset. State-of-the-art public CAN IDS datasets are limited to real fabrication (simple message injection) attacks and simulated attacks often in synthetic data, lacking fidelity. In general, the physical effects of attacks on the vehicle are not verified in the available datasets. Only one dataset provides signal-translated data but is missing a corresponding “raw” binary version. This issue pigeon-holes CAN IDS research into testing on limited and often inappropriate data (usually with attacks that are too easily detectable to truly test the method). The scarcity of appropriate data has stymied comparability and reproducibility of results for researchers. As our primary contribution, we present the Real ORNL Automotive Dynamometer (ROAD) CAN IDS dataset, consisting of over 3.5 hours of one vehicle’s CAN data. ROAD contains ambient data recorded during a diverse set of activities, and attacks of increasing stealth with multiple variants and instances of real (i.e. non-simulated) fuzzing, fabrication, unique advanced attacks, and simulated masquerade attacks. To facilitate a benchmark for CAN IDS methods that require signal-translated inputs, we also provide the signal time series format for many of the CAN captures. Our contributions aim to facilitate appropriate benchmarking and needed comparability in the CAN IDS research field.

97 MATHEMATICS AND COMPUTING↗

Inverse Modelling to Obtain Head Movement Controller Signal

Experimentally obtained dynamics of time-optimal, horizontal head rotations have previously been simulated by a sixth order, nonlinear model driven by rectangular control signals. Electromyography (EMG) recordings have spects which differ in detail from the theoretical rectangular pulsed control signal. Control signals for time-optimal as well as sub-optimal horizontal head rotations were obtained by means of an inverse modelling procedures. With experimentally measured dynamical data serving as the input, this procedure inverts the model to produce the neurological control signals driving muscles and plant. The relationships between these controller signals, and EMG records should contribute to the understanding of the neurological control of movements.

Kim, W. S.↗

Overview of the front-end electronics of CMS HGCal - including readout and powering

The end-cap calorimeters of CMS will be upgraded to a single High Granularity Calorimeter (HG-Cal) for the HL-LHC, including both silicon sensors and scintillator tiles with on-tile SiPMs as active elements. The readout of the active elements is performed by an ASIC (HGCROC in 130 nm CMOS technology) that measures the amplitude and arrival time of the signals. The amplitude is measured over a large dynamic range to allow calibration with single particles and the measurement of TeV showers. The time of arrival of high-energy showers will be measured with a precision of around 30 ps. A second pair of “concentrator” ASICs - ECON-T and ECON-D - takes the data from the HGCROC channels and packages them for transmission via optical links to the off-detector electronics. The ECON-T transmits trigger data at 40 MHz, to form part of the level-1 trigger. The ECON-D transmits concentrated data packets at up to 1 MHz, upon reception of a level-1 trigger signal. In addition to these ASICs, HGCal will use modified versions of common HL-LHC electronics developments, for the power chain and the optical control and readout. The dense nature of the HGCal provides additional challenges for the electronic boards and cabling. In this proceedings the overall HGCal front electronics scheme, including the latest performance of the HGCROC and ECON ASICs is presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Use of a controlled experiment and computational models to measure the impact of sequential peer exposures on decision making

It is widely believed that one’s peers influence product adoption behaviors. This relationship has been linked to the number of signals a decision-maker receives in a social network. But it is unclear if these same principles hold when the “pattern” by which it receives these signals vary and when peer influence is directed towards choices which are not optimal. To investigate that, we manipulate social signal exposure in an online controlled experiment using a game with human participants. Each participant in the game decides among choices with differing utilities. We observe the following: (1) even in the presence of monetary risks and previously acquired knowledge of the choices, decision-makers tend to deviate from the obvious optimal decision when their peers make a similar decision which we call the influence decision, (2) when the quantity of social signals vary over time, the forwarding probability of the influence decision and therefore being responsive to social influence does not necessarily correlate proportionally to the absolute quantity of signals. To better understand how these rules of peer influence could be used in modeling applications of real world diffusion and in networked environments, we use our behavioral findings to simulate spreading dynamics in real world case studies. We specifically try to see how cumulative influence plays out in the presence of user uncertainty and measure its outcome on rumor diffusion, which we model as an example of sub-optimal choice diffusion. Together, our simulation results indicate that sequential peer effects from the influence decision overcomes individual uncertainty to guide faster rumor diffusion over time. However, when the rate of diffusion is slow in the beginning, user uncertainty can have a substantial role compared to peer influence in deciding the adoption trajectory of a piece of questionable information.

97 MATHEMATICS AND COMPUTING↗

Semiquantitative and Quantitative Dynamic Contrast-Enhanced Magnetic Resonance Imaging Measurements Predict Radiation Response in Cervix Cancer

Purpose: To evaluate semiquantitative and quantitative dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) measurements in predicting the response to radiotherapy in cervix cancer. Methods and Materials: Patients with cervix cancer treated radically with chemoradiotherapy had DCE-MRI at three time points: before starting treatment, after 2 weeks of radiotherapy, and in the 5th week of radiotherapy. Semiquantitative measurements obtained from the signal intensity vs. time plots included arrival time of contrast, the slope and maximum slope of contrast uptake, time for peak enhancement, and the contrast enhancement ratio (CER). Pharmacokinetic modeling with a modeled vascular input function was used for the quantitative measurements volume transfer constant (K{sup trans}), rate constant (k{sub ep}), fraction plasma volume (fPV), and the initial area under gadolinium-time curve. The correlation of these measurements at each of the three time points with radiologic tumor response was investigated. Results: Thirteen patients had a total of 38 scans. There was no correlation between the DCE-MRI measurements and the corresponding tumor volumes. A statistically significant correlation with percentage tumor regression was shown with the pretreatment DCE-MRI semiquantitative parameters of peak time (p = 0.046), slope (p = 0.025), maximum slope (p = 0.046), and CER (p = 0.025) and the quantitative parameters K{sup trans} (p = 0.043) and k{sub ep} (p = 0.022). Second and third scan measurements did not show any correlation. Conclusions: This is the first study to show that pretreatment DCE-MRI quantitative parameters predict the radiation response in cervix cancer. These measurements may allow a more meaningful comparison of DCE-MRI studies from different centers.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

FeSi 4 P 4 and CoSi 3 P 3 : Hidden Gems of Ternary Tetrel Pnictides with Outstanding Nonlinear Optical Properties

Metal silicon phosphides have shown promise as nonlinear optical materials. To be practically useful and cheap, earth-abundant 3d transition metals are preferred over their scarcer and more expensive 4d and 5d counterparts. Here, we developed a synthetic method to produce polycrystalline bulk powders and millimeter-sized single crystals of ternary compounds FeSi 4 P 4 and CoSi 3 P 3 . Both studied compounds have noncentrosymmetric and chiral crystal structures with ordered Si/P arrangements as was confirmed by single-crystal X-ray diffraction and solid-state NMR. Despite the presence of the transition metal, FeSi 4 P 4 and CoSi 3 P 3 are semiconductors with direct band gaps of 1.3 and 1.6 eV, respectively, indicating low-spin d 6 electronic configuration for octahedral Fe 2+ and Co 3+ . Relative to reported sulfide materials, FeSi 4 P 4 and CoSi 3 P 3 small band gap semiconductors demonstrate an outstanding combination of second-harmonic generation (SHG) activity and laser damage threshold (LDT). Both studied materials are phase-matchable with a 2.09 μm laser and not only exhibit 2.5–3.0 times stronger SHG signal than that of the state-of-the-art AgGaS 2 standard but also demonstrate an LDT response of 2.3–2.5 times higher than that of AgGaS 2 (at 1.09 μm laser with a pulse width of 10 ns)-which is unprecedented for small band gap semiconductors.

36 MATERIALS SCIENCE↗

The Squeezed Bispectrum from CHIME H I Emission and Planck Cosmic Microwave Background Lensing: Current Sensitivity and Forecasts

Line intensity mapping using atomic hydrogen (H I) has the potential to efficiently map large volumes of the Universe if the signal can be successfully separated from overwhelmingly bright radio foreground emission. This motivates cross correlations, to ascertain the cosmological nature of measured H I fluctuations, and to study their connections with galaxies and the underlying matter density field. However, these same foregrounds render the cross correlation with projected fields such as the lensing of the cosmic microwave background (CMB) difficult. Indeed, the correlated Fourier modes vary slowly along the line of sight and are thus most contaminated by the smooth-spectrum radio continuum foregrounds. In this paper, we implement a method that avoids this issue by attempting to measure the nonlinear gravitational coupling of the small-scale 21 cm power from the Canadian Hydrogen Intensity Mapping Experiment (CHIME) with large-scale Planck CMB lensing. This measurement is a position-dependent power spectrum, i.e., a squeezed integrated bispectrum. Using 94 nights of CHIME data between 1.0 < z < 1.3 and aggressive foreground filtering, we find that the expected signal is 5 times smaller than the current noise. We forecast that incorporating the additional nights of CHIME data already collected would enable a signal-to-noise ratio of 3, without any further improvements in filtering for foreground cleaning.

21cm↗

Electro-Optical Modulator Bias Control Using Bipolar Pulses

An improved method has been devised for controlling the DC bias applied to an electro-optical crystal that is part of a Mach-Zehnder modulator that generates low-duty-cycle optical pulses for a pulse-position modulation (PPM) optical data-communication system. In such a system, it is desirable to minimize the transmission of light during the intervals between pulses, and for this purpose, it is necessary to maximize the extinction ratio of the modulator (the ratio between the power transmitted during an "on" period and the power transmitted during an "off" period). The present method is related to prior dither error feedback methods, but unlike in those methods, there is no need for an auxiliary modulation subsystem to generate a dithering signal. Instead, as described below, dither is effected through alternation of the polarity of the modulation signal. The upper part of Figure 1 schematically depicts a Mach-Zehnder modulator. The signal applied to the electro-optical crystal consists of a radio-frequency modulating pulse signal, VRF, superimposed on a DC bias Vbias. Maximum extinction occurs during the off (VRF = 0) period if Vbias is set at a value that makes the two optical paths differ by an odd integer multiple of a half wavelength so that the beams traveling along the two paths interfere destructively at the output beam splitter. Assuming that the modulating pulse signal VRF has a rectangular waveform, maximum transmission occurs during the "on" period if the amplitude of VRF is set to a value, V , that shifts the length of the affected optical path by a half wavelength so that now the two beams interfere constructively at the output beam splitter. The modulating pulse signal is AC-coupled from an amplifier to the electro-optical crystal. Sometimes, two successive pulses occur so close in time that the operating point of the amplifier drifts, one result being that there is not enough time for the signal level to return to ground between pulses. Also, the difference between the optical-path lengths can drift with changes in temperature and other spurious effects. The effects of both types of drift are suppressed in the present method, in which one takes advantage of the fact that when Vbias is set at the value for maximum extinction, equal-magnitude positive and negative pulses applied to the electro-optical crystal produce equal output light pulses.

Farr, William↗

Ultrafast Optical Spin Echo for Electron Spins in Semiconductors

Spin-based quantum computing and magnetic resonance techniques rely on the ability to measure the coherence time T{sub 2} of a spin system. We report on the experimental implementation of all-optical spin echo to determine the T{sub 2} time of a semiconductor electron-spin system. We use three ultrafast optical pulses to rotate spins an arbitrary angle and measure an echo signal as the time between pulses is lengthened. Unlike previous spin-echo techniques using microwaves, ultrafast optical pulses allow clean T{sub 2} measurements of systems with dephasing times (T{sub 2}*) fast in comparison to the time scale for microwave control. This demonstration provides a step toward ultrafast optical dynamic decoupling of spin-based qubits.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Transionospheric propagation predictions

The current status and future prospects of the capability to make transionospheric propagation predictions are addressed, highlighting the effects of the ionized media, which dominate for frequencies below 1 to 3 GHz, depending upon the state of the ionosphere and the elevation angle through the Earth-space path. The primary concerns are the predictions of time delay of signal modulation (group path delay) and of radio wave scintillation. Progress in these areas is strongly tied to knowledge of variable structures in the ionosphere ranging from the large scale (thousands of kilometers in horizontal extent) to the fine scale (kilometer size). Ionospheric variability and the relative importance of various mechanisms responsible for the time histories observed in total electron content (TEC), proportional to signal group delay, and in irregularity formation are discussed in terms of capability to make both short and long term predictions. The data base upon which predictions are made is examined for its adequacy, and the prospects for prediction improvements by more theoretical studies as well as by increasing the available statistical data base are examined.

Klobucher, J. A.↗

The Application and Potential Artifacts of Zeeman Cold Vapor Atomic Absorption Spectrometry in Mercury Stable Isotope Analysis

Zeeman cold vapor atomic absorption spectrometry (CVAAS) has been widely used for environmental mercury (Hg) detection and quantification for decades, but little is known about its utility and potential artifacts in analyzing Hg with varying isotope compositions. We show that each Hg isotope responds differently by CVAAS analysis, with 200 Hg and 202 Hg isotopes exhibiting signal intensities ~10 times greater than those of 198 Hg and 201 Hg isotopes. However, all Hg isotopes show a linear correlation between Hg concentration and signal intensity, validated by both measurements and theoretical simulations. Zeeman CVAAS could thus offer a convenient, inexpensive tool for determining Hg isotopes, particularly in using one or two enriched Hg isotopes for tracing Hg biogeochemical transformations, such as partitioning, ion exchange, sorption–desorption, and methylation–demethylation in environmental matrices. Additionally, we caution that care must be taken when CVAAS is used for quantifying Hg in samples with changing isotope compositions to avoid measurement errors.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Optical-pump–terahertz-probe spectroscopy in high magnetic fields with kHz single-shot detection

We demonstrate optical pump–THz probe (OPTP) spectroscopy with a variable external magnetic field (0–9 T), in which the time-dependent THz signal is measured by echelon-based single-shot detection at a repetition rate of 1 kHz. The method reduces data acquisition times by more than an order of magnitude compared to conventional electro-optic sampling using a scanning delay stage. The approach illustrates the wide applicability of the single-shot measurement approach to non-equilibrium systems that are studied through OPTP spectroscopy, especially in cases where parameters such as magnetic field strength (B) or other experimental parameters are varied. We demonstrate the capabilities of our measurement by performing cyclotron resonance experiments in bulk silicon, where we observe B-field-dependent carrier relaxation and distinct relaxation rates for different carrier types. We use a pair of economical linear array detectors to measure 500 time points on each shot, offering an equivalent performance to camera-based detection with possibilities for higher repetition rates.

Instruments & Instrumentation↗

Measurement of quantum fluctuations in geometry

A particular form for the quantum indeterminacy of relative spacetime position of events is derived from the context of a holographic geometry with a minimum length at the Planck scale. The indeterminacy predicts fluctuations from a classically defined geometry in the form of ''holographic noise'' whose spatial character, absolute normalization, and spectrum are predicted with no parameters. The noise has a distinctive transverse spatial shear signature and a flat power spectral density given by the Planck time. An interferometer signal displays noise due to the uncertainty of relative positions of reflection events. The noise corresponds to an accumulation of phase offset with time that mimics a random walk of those optical elements that change the orientation of a wavefront. It only appears in measurements that compare transverse positions and does not appear at all in purely radial position measurements. A lower bound on holographic noise follows from a covariant upper bound on gravitational entropy. The predicted holographic noise spectrum is estimated to be comparable to measured noise in the currently operating interferometric gravitational-wave detector GEO600. Because of its transverse character, holographic noise is reduced relative to gravitational wave effects in other interferometer designs, such as the LIGO observatories, where beam power is much less in the beam splitter than in the arms.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Observation of prolonged coherence time of the collective spin wave of an atomic ensemble in a paraffin-coated {sup 87}Rb vapor cell

We report a prolonged coherence time of the collective spin wave of a thermal {sup 87}Rb atomic ensemble in a paraffin-coated cell. The spin wave is prepared through a stimulated Raman process. The long coherence time is achieved by prolonging the lifetime of the spins with paraffin coating and minimize dephasing with optimal experimental configuration. The observation of the long-time-delayed-stimulated Stokes signal in the writing process suggests the prolonged lifetime of the prepared spins; a direct measurement of the decay of anti-Stokes signal in the reading process shows the coherence time is up to 300 mus after minimizing dephasing. This is 100 times longer than the reported coherence time in the similar experiments in thermal atomic ensembles based on the Duan-Lukin-Cirac-Zoller and its improved protocols. This prolonged coherence time sets the upper limit of the memory time in quantum repeaters based on such protocols, which is crucial for the realization of long-distance quantum communication. The previous reported fluorescence background in the writing process due to collision in a sample cell with buffer gas is also reduced in a cell without buffer gas.

74 ATOMIC AND MOLECULAR PHYSICS↗