Results for “TIME RESOLUTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

TRACER-VOC: Speciated Volatile Organic Compounds at the Tracking Aerosol Convection Interactions Experiment Field Campaign Report

Formation of secondary organic aerosol (SOA) is responsible for the growth of particles into cloud condensation nuclei (CCN)-relevant sizes and accounts for a substantial fraction of aerosol mass in the troposphere. Despite its wide abundance and importance, capturing SOA in regional and climate models is still challenging due to complex chemical transformations involved in production of SOA. Oxidation products of biogenic hydrocarbons, such as isoprene, monoterpenes, and sesquiterpenes account for the largest fraction of SOA mass over the continents. As such, biogenic SOA is an important source of continental CCN, and has been recently shown to nucleate ice in the deposition mode. To better account for the processes involved in SOA formation in global and regional climate models, we need better measurements of sources and transformations of volatile organic compounds (VOCs), the precursors to SOA formation in the atmosphere. Understanding aerosol-deep convection interactions is an important science driver of the Tracking Aerosol Convection Interactions Experiment (TRACER), requiring a characterization of the critical controls on aerosol properties and processes, and how those properties and processes vary spatially and temporally in the Houston area. In that environment, the atmospheric photo-oxidative chemistry that drives the evolution and transformation of aerosol properties and processes is strongly impacted by the emission of VOCs, which have both anthropogenic (e.g., industrial, urban, transportation, biomass burning) and biogenic (e.g., marine) sources in the region. Understanding (and disentangling) the complex role of VOCs in such a heterogenous region requires high-time-resolution, speciated VOC measurements that are spatially resolved. To meet these measurement requirements, the U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility’s time-of-flight proton transfer reaction-mass spectrometer (ToF-PTR-MS) was deployed during the TRACER intensive operational period (IOP) from June to September, 2022 at the ancillary site (ANC), which was sited to provide a characterization of the rural atmospheric environment in contrast to the main site.

54 ENVIRONMENTAL SCIENCES↗

ADRIANO2 Calorimeter Performance from 2022 Test Beams

A novel high-granularity dual-readout calorimetric technique was developed as part of the T1604 collaboration. The ADRIANO2 Calorimeter Prototype consists of a pair of optically isolated, small sized tiles made of scintillating plastic and lead glass. Čerenkov light from the lead glass are exploited to for high resolution timing measurements, while high granularity from scintillating plastic can be used to probe the spatial component of the particle shower. This setup works for excellent energy resolution and particle detection for REDTOP as it is crucial for a calorimeter to detect the decay products of eta/eta-prime mesons. Measurements were collected on ADRIANO2 between February to December 2022 to evaluate the detector performance at Fermilab’s Test Beam Facility. The key metrics extracted from my analysis are the detector’s efficiency for various tile configuration and light-yield which will then be used as parameters for an upgraded REDTOP monte-carlo simulation campaign. An in-depth analysis of ADRIANO2 performance are detailed in this presentation.

43 PARTICLE ACCELERATORS↗

Nucleocosmochronology

Nucleocosmochronology is analyzed on the basis of elemental isotopic abundances of radionuclides. The production and depletion mechanisms for the cosmological chronometers are investigated and model-independent theories are reviewed. Emphasis is given to the significance of the mean age of the elements and the time resolution of the last nucleosynthetic events contributing to the solar system, and it is shown how the intermediate-lived chronometers may give information on the time dependence shape of the production function. Anomalous nucleocosmochronology is investigated and galactic and cosmological constraints are described in terms of time scales for the mean age of elements and galaxies and the age of the universe. Data resulting from both model-independent and dependent analyses are compared. Results based on the mean age for the r-process elements suggest a lower limit to the age of the galaxy and the universe. It is concluded that nucleocosmochronology, when coupled with other independent determinations for the age of the universe, defines a concordant universe age of 13.5-15.5 billion years. The shape of the production function is not well determined because of the uncertainties in the xenon data.

Symbalisty, E. M. D.↗

Energetic particle microsignatures of Saturn's satellites

During Voyager's 1980 and 1981 encounters with Saturn, the low energy charged particle experiment observed satellite microsignatures in ions and electrons. Each of the five major satellites within Titan's orbit were associated with at least one absorption feature in the high time resolution data. Microsignatures are usually observed in the corotational wake region within about 25 deg in azimuth of a satellite, and do not generally occur at times predicted by a centered, aligned dipole. A better predictive model seems to be that of an aligned, axisymmetric field with significant quadrupole and octupole terms.

Carbary, J. F.↗

First interferometric observations of solar microwave millisecond spike bursts

Observations, with one-dimensional spatial resolution, of solar microwave millisecond spikes at 2.8 GHz are reported. The observations were made with the Owens Valley frequency-agile interferometer with 20 ms time resolution. It is found that the spikes occur at a position different from that of the underlying gyrosynchrotron radio burst source. All of the spikes during the rising part of the burst come from the same one-dimensional location to within + or - 1 arcsec, despite the fact that rapid evolution in the sense and degree of circular polarization was observed. The one-dimensional position of the spikes is consistent with a location over a large sunspot, suggesting that the emission occurs in a region of strong, converging magnetic field. The observations support the suggestion that the spikes are due to the electron-cyclotron maser mechanism.

Gary, Dale E.↗

Soft Real-Time PID Control on a VME Computer

microPID (uPID) is a computer program for real-time proportional + integral + derivative (PID) control of a translation stage in a Fourier-transform ultraviolet spectrometer. microPID implements a PID control loop over a position profile at sampling rate of 8 kHz (sampling period 125microseconds). The software runs in a strippeddown Linux operating system on a VersaModule Eurocard (VME) computer operating in real-time priority queue using an embedded controller, a 16-bit digital-to-analog converter (D/A) board, and a laser-positioning board (LPB). microPID consists of three main parts: (1) VME device-driver routines, (2) software that administers a custom protocol for serial communication with a control computer, and (3) a loop section that obtains the current position from an LPB-driver routine, calculates the ideal position from the profile, and calculates a new voltage command by use of an embedded PID routine all within each sampling period. The voltage command is sent to the D/A board to control the stage. microPID uses special kernel headers to obtain microsecond timing resolution. Inasmuch as microPID implements a single-threaded process and all other processes are disabled, the Linux operating system acts as a soft real-time system.

Karayan, Vahag↗

Ultrasound Thermal Field Imaging of Opaque Fluids

We have initiated an experimental program to develop an ultrasound system for non-intrusively imaging the thermal field in opaque fluids under an externally imposed temperature gradient. Many industrial processes involve opaque fluids, such as molten metals, semiconductors, and polymers, often in situations in which thermal gradients are important. For example, one may wish to understand semiconductor crystal growth dynamics in a Bridgman apparatus. Destructive testing of the crystal after the process is completed gives only indirect information about the fluid dynamics of the formation process. Knowledge of the coupled thermal and velocity fields during the growth process is then essential. Most techniques for non-intrusive velocity and temperature measurement in fluids are optical in nature, and hence the fluids studied must be transparent. In some cases (for example, LDV (laser Doppler velocimetry) and PIV (particle imaging velocimetry)) the velocities of small neutrally buoyant seed particles suspended in the fluid, are measured. Without particle seeding one can use the variation of the index of refraction of the fluid with temperature to visualize, through interferometric, Schlieren or shadowgraph techniques, the thermal field. The thermal field in turn gives a picture of the pattern existing in the fluid. If the object of study is opaque, non-optical techniques must be used. In this project we focus on the use of ultrasound, which propagates easily through opaque liquids and solids. To date ultrasound measurements have almost exclusively relied on the detection of sound scattered from density discontinuities inside the opaque material of interest. In most cases it has been used to visualize structural properties, but more recently the ultrasound Doppler velocimeter has become available. As in the optical case, it relies on seed particles that scatter Doppler shifted sound back to the detector. Doppler ultrasound techniques are, however, not useful for studying convective fluid flow in crystal growth, because particle seeding is unacceptable and flow velocities are typically too low to be resolved, and may be even lower in microgravity conditions where buoyancy forces are negligible. We will investigate a different use of ultrasound to probe the flows of opaque fluids non-intrusively and without the use of seed particles: our goal is to ultrasonically visualize the thermal field of opaque fluids with relatively high spatial resolution. The proposed technique relies upon the variation of sound speed with temperature of the fluid. A high frequency ultra-sound pulse passing through a fluid-filled chamber will traverse the chamber in a time determined by the relevant chamber dimension and the temperature of the fluid through which the pulse passes. With high time-resolution instrumentation that compares the excitation signal with the received pulse we can detect the influence of the fluid temperature on the pulse travel time. This is effectively an interferometric system, which in its optical form is an extremely sensitive approach to measuring thermal fields in fluids. Moreover, the temperature dependence of sound velocity in liquid metals is comparable to the temperature dependence of the speed of light required for accurate interferometric thermal images in transparent fluids. With an array of transducers scanned electronically a map of the thermal field over the chamber could be produced. An alternative approach would be to use the ultrasound analog of the shadowgraph technique. In the optical version, collimated light passes through the fluid, where it is focused or defocused locally by temperature field induced variations of the index of refraction. The resulting image reveals the thermal field through the spatial pattern of light intensity variations. By analogy, an ultrasound plane wave traversing an opaque fluid sample would be also locally focused or defocused depending on the speed of sound variations, giving rise to spatial variations in sound intensity that will reveal the thermal field pattern. These approaches could be applied to any situation in which temperature differences are expected to occur, and will rapidly provide information about the flow that simply cannot be obtained by any current intrusive or non-intrusive diagnostic technique. As materials processing in microgravity matures it will become increasingly important to have available simple and versatile diagnostic tools, such as we will develop, for studying the flows of opaque fluids under thermal forcing.

Andereck, C. David↗

High-resolution imaging of solar system objects

A very extensive Io sodium imaging program beginning with the first images of the cloud and culminating in comprehensive characterization of the cloud's appearance and behavior as a function of both time and Io's orbital position now forms the basis for a collaborative modeling analysis and a continued observational study with emphasis on understanding how the cloud's behavior is diagnostic of spatial and temporal variations in the physical conditions of the inner Jovian magnetosphere. The sodium cloud was found to have a variety of systematic variations, a pronounced east-west orbital asymmetry, and temporal changes which could be diagnostic of time changes in both Io and its plasma environment. New comet imaging programs initiated at the 3.6-meter Canada-France-Hawaii Telescope draw upon both ultra high time resolution and high spatial resolution imaging capabilities. Seven observing runs between Dec. 1984 and May 1986 were devoted to observing Halley, Giacobini-Zinner, and several other comets. Among these observations were the first images of Halley through IHW filters, and images of Giacobini-Zinner during the ICE encounter which have been directly correlated with ICE magnetic field measurements.

Goldberg, B. A.↗

Calibration of the sub-aperture backscatter system on OMEGA EP

The sub-aperture backscatter (SABS) diagnostic on the OMEGA EP Laser System is a diagnostic that is used to measure the backscattered and sidescattered light during laser–plasma interaction experiments that are relevant to high-energy-density physics and inertial confinement fusion. The diagnostic collects stimulated Brillouin scattering (SBS) UV light at around 351 nm and stimulated Raman scattering (SRS) in the visible-light regime in the 420–720-nm-wavelength range and provides spectrally and temporally resolved information. Five 1-in. light collectors, composed of a lens, ground glass diffuser, and coupling into a 300-μm fiber, are positioned behind the last steering mirror on one of the four beamlines to catch a portion of the beam cross section (~1.5%) of the emission that is scattered into the beamline. The SRS light is collected in two light collectors, combined, and transported via graded index fibers to a streaked spectrometer. The SABS-SRS streak spectrometer has a temporal and spectral resolution of 100 ps and 1 nm, respectively. Three other light collectors collect, combine, and transport the SBS signal to a Hamamatsu high-voltage photodiode, where an oscilloscope digitizes the data, providing a time resolution of better than 1 ns. To obtain an absolute energy calibration of SRS measurements, light signals of known energy and wavelength were injected into the light collectors one at a time. The resulting counts on the streak camera charge-coupled device for SRS are then correlated with the incident fluence of scattered light at the light collector in order to allow a quantitative assessment of streak camera sensitivity to determine the energy of the scattered light during experiments. The measurements were performed in situ from the light collectors to the detectors. Other offline measurements provided the transmission of the optics between the target chamber center and the light collectors.

47 OTHER INSTRUMENTATION↗

Optimization and application of cooled avalanche photodiodes for spectroscopic fluctuation measurements with ultra-fast charge exchange recombination spectroscopy

The Ultra Fast Charge Exchange Recombination Spectroscopy (UF-CHERS) diagnostic is a highly specialized spectroscopic instrument with 2 spatial channels consisting of 8 spectral channels each and a resolution of ~0.25 nm deployed at DIII-D to measure turbulent ion temperature fluctuations. Charge exchange emissions are obtained between 528-530 nm with 1 μs time resolution to study plasma instabilities. A primary challenge of extracting fluctuation measurements from raw UF-CHERS signals is photon and electronic noise. In order to reduce dark current, the Avalanche Photodiode (APD) detectors are thermoelectrically cooled. State-of-the-art components are used for the signal amplifiers and conditioners to minimize electronic noise. Due to the low incident photon power (≤ 1 nW), APDs with a gain of up to 300 are used to optimize the signal to noise ratio. Maximizing the APDs’ gain while minimizing the excess noise factor (ENF) is essential since the total noise of the diagnostic sets a floor for the minimum level of detectable broadband fluctuations. The APDs’ gain should be high enough that photon noise dominates electronic noise, but not excessive so that the ENF overwhelms plasma fluctuations. A new generation of cooled APDs and optimized preamplifiers exhibits significantly enhanced signal-to-noise compared to a previous generation. Experiments at DIII-D have allowed for characterization and optimization of the ENF vs. gain. Here, a gain of ~100 at 1700 V is found to be near optimal for most plasma conditions. Ion temperature and toroidal velocity fluctuations due to the Edge Harmonic Oscillation (EHO) in Quiescent H-mode (QH) plasmas are presented to demonstrate UF-CHERS’ capabilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Photon counting phosphorescence lifetime imaging with TimepixCam

TimepixCam is a novel fast optical imager based on an optimized silicon pixel sensor with a thin entrance window, and read out by a Timepix ASIC. The 256 x 256 pixel sensor has a time resolution of 15 ns at a sustained frame rate of 10 Hz. We used this sensor in combination with an image intensifier for wide-field time-correlated single photon counting (TCSPC) imaging. We have characterised the photon detection capabilities of this detector system, and employed it on a wide-field epifluorescence microscope to map phosphorescence decays of various iridium complexes with lifetimes of about 1 μs in 200 μm diameter polystyrene beads.

47 OTHER INSTRUMENTATION↗

Development of a high-speed H-alpha camera system for the observation of rapid fluctuations in solar flares

A solid-state digital camera was developed for obtaining H alpha images of solar flares with 0.1 s time resolution. Beginning in the summer of 1988, this system will be operated in conjunction with SMM's hard X-ray burst spectrometer (HXRBS). Important electron time-of-flight effects that are crucial for determining the flare energy release processes should be detectable with these combined H alpha and hard X-ray observations. Charge-injection device (CID) cameras provide 128 x 128 pixel images simultaneously in the H alpha blue wing, line center, and red wing, or other wavelength of interest. The data recording system employs a microprocessor-controlled, electronic interface between each camera and a digital processor board that encodes the data into a serial bitstream for continuous recording by a standard video cassette recorder. Only a small fraction of the data will be permanently archived through utilization of a direct memory access interface onto a VAX-750 computer. In addition to correlations with hard X-ray data, observations from the high speed H alpha camera will also be correlated and optical and microwave data and data from future MAX 1991 campaigns. Whether the recorded optical flashes are simultaneous with X-ray peaks to within 0.1 s, are delayed by tenths of seconds or are even undetectable, the results will have implications on the validity of both thermal and nonthermal models of hard X-ray production.

Kiplinger, Alan L.↗

Spectrally filtered ps–ns emission dynamics of atmospheric-pressure nanosecond pulsed plasmas

The temporal dynamics of atmospheric-pressure nanosecond pulsed plasma discharges in a pin-to-pin electrode configuration are studied using streak-camera line imaging of the interelectrode gap with a time resolution as short as ~25 ps. Discharge emission initiates homogeneously throughout the interelectrode gap with no detectable streamer propagation and then temporally decays in two distinct phases. Plasma emission bands attributed to various electronic transitions are tracked for single discharges in air and N 2 . Spectral filtering of the excited molecular states reveals that the N 2 (C–B) and N 2 (B–A) emission bands evolve in distinct early and late phases, respectively, with a time separation of ~15–20 ns. Furthermore, significant differences in the temporal dynamics of plasma discharges in air and N2 are observed. High levels of excited-state atomic oxygen and NO appear after the initial decay of the N 2 (C) state and coincide primarily with the latter phases of plasma evolution in air environments. From temporal traces of discharge emission, the formation and relaxation timescales of the electronically excited states of N 2 are quantified in pure N2 and air environments with sub-nanosecond resolution. The streak-OES (optical emission spectroscopy) technique enables quantitative time-resolved studies of key chemical species for model validation in ultra-short-pulsed plasmas.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Response of fs-Laser-Irradiated Diamond by Ultrafast Electron Diffraction

Structural details of the proposed solid–liquid phase transition of carbon have remained elusive, despite years of study. While it is theorized that novel carbon materials form from a liquid precursor, experimental studies have lacked the temporal and spatial resolution necessary to fully characterize the purported liquid state. Here, in this work, we utilize megaelectronvolt-ultrafast electron diffraction (MeV-UED) to study laser irradiated submicron diamond thin films in a pump–probe scheme with picosecond time resolution to visualize potential structural changes of excited diamond. We probe the structure of diamond using a combination of fluences (13, 40 J/cm 2 ) and time delays (10, 25, 100 ps), but observe negligible changes in the static diffraction pattern of diamond and an overall decrease in diffraction intensity up to 100 ps after the excitation pulse. We thus conclude that no appreciable amount of liquid or graphitized carbon is present and highlight the structural resilience of bulk diamond to intense 800 nm ultrafast laser pulses.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Digital pulse deconvolution with adaptive shaping for real-time high-resolution high-throughput gamma spectroscopy

A high-resolution high-throughput real-time adaptive digital pulse processing system is developed for high count rate gamma-ray spectroscopy applications. The adaptive digital pulse processing algorithms are implemented on a reconfigurable FPGA and include a pulse deconvolver, adaptive shaping filter, timing filter, baseline restorer, and pile-up rejecter. Digital pulse deconvolution is implemented to reconstruct the original detector signal from the preamplifier signal, which reduces the resolution deterioration due to pulse pile-up. The deconvoluted signal is shaped with a trapezoid filter and the shaping parameter is selected adaptively based on the time separation between successive input pulses. Experimental measurements are performed with a 137Cs source under varying count-rate conditions and using germanium detectors equipped with resistive feedback and transistor reset preamplifiers (TRP). The results herein demonstrate that when using a TRP, adaptive digital signal processing allows handling 106 counts/s. In addition, the implementation of a deconvolution approach limits resolution deterioration for throughput rates that are 4 to 10 times better than achievable in typical digital and analog gamma-ray spectroscopy systems.

47 OTHER INSTRUMENTATION↗

How lasing happens in CsPbBr 3 perovskite nanowires

Lead halide perovskites are emerging as an excellent material platform for optoelectronic processes. There have been extensive discussions on lasing, polariton formation, and nonlinear processes in this material system, but the underlying mechanism remains unknown. Here we probe lasing from CsPbBr 3 perovskite nanowires with picosecond (ps) time resolution and show that lasing originates from stimulated emission of an electron-hole plasma. We observe an anomalous blue-shifting of the lasing gain profile with time up to 25 ps, and assign this as a signature for lasing involving plasmon emission. The time domain view provides an ultra-sensitive probe of many-body physics which was obscured in previous time-integrated measurements of lasing from lead halide perovskite nanowires.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Following the dynamics of matter with femtosecond precision using the X-ray streaking method

X-ray Free Electron Lasers (FELs) can produce extremely intense and very short pulses, down to below 10 femtoseconds (fs). Among the key applications are ultrafast time-resolved studies of dynamics of matter by observing responses to fast excitation pulses in a pump-probe manner. Detectors with sufficient time resolution for observing these processes are not available. Therefore, such experiments typically measure a sample's full dynamics by repeating multiple pump-probe cycles at different delay times. This conventional method assumes that the sample returns to an identical or very similar state after each cycle. Here we describe a novel approach that can provide a time trace of responses following a single excitation pulse, jitter-free, with fs timing precision. We demonstrate, in an X-ray diffraction experiment, how it can be applied to the investigation of ultrafast irreversible processes.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Toward implementing autonomous adaptive data acquisition for scanning hyperspectral imaging of biological systems

Autonomous experimentation is an emerging area of research, primarily related to autonomous vehicles, scientific combinatorial discovery approaches in materials science and drug discovery, and iterative research loops of planning, experimentation, and analysis. However, autonomous approaches developed in these contexts are difficult to apply to high-dimensional mapping technologies, such as scanning hyperspectral imaging of biological systems, due to sample complexity and heterogeneity. We briefly cover the history of adaptive sampling algorithms and surrogate modeling in order to define autonomous adaptive data acquisition as an objective-based, flexible building block for future biological imaging experimentation driven by intelligent infrastructure. We subsequently summarize the recent implementations of autonomous adaptive data acquisition (AADA) for scanning hyperspectral imaging, assess how these address the difficulties of autonomous approaches in hyperspectral imaging, and highlight the AADA design variation from a goal-oriented perspective. Finally, we present a modular AADA architecture that embeds AADA-driven flexible building blocks to address the challenge of time resolution for high-dimensional scanning hyperspectral imaging of nonequilibrium dynamical systems. In our example research-driven experimental design case, we propose an AADA infrastructure for time-resolved, noninvasive, and label-free scanning hyperspectral imaging of living biological systems. This AADA infrastructure can accurately target the correct state of the system for experimental workflows that utilize subsequent expensive, high-information-content analytical techniques.

59 BASIC BIOLOGICAL SCIENCES↗