Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TECHNICAL DETAILS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

Technical Potential for Hydropower Capacity at Non-powered Dams

In the last decade, retrofits of existing nonpowered dams (NPDs) have made up the largest share of capacity increases for US hydropower. Accurate estimates of potential capacity and generation at NPDs help identify sites that may be worth investing in detailed feasibility analyses and design exploration. This dataset consists of NPDs in the conterminous US with at least 100kW of theoretical potential based on earlier resource assessments. Historical daily streamflow (modeled or from USGS gauge records), hydraulic head (based on historical observations or primary purpose and dam height) are the main inputs for HydroGenerate which determines design flow and turbine efficiencies and then calculates nominal capacity, daily generation, and capacity factor. These outputs are summarized on a monthly basis (i.e., generation (MWh) and capacity factor averaged for each month from January to December) and overall (i.e., nominal capacity, average annual generation (MWh), and average annual capacity factor). A total of 4.1 GW capacity is estimated across all 2,564 NPDs included in the dataset.

13 HYDRO ENERGY↗

Automating the Coupling of ORIGEN with GADRAS via the Fallout Analysis Tool for National Technical Nuclear Forensics

Nuclear forensic teams will be deployed to collect and evaluate fallout samples on the ground in the scenario of a low-yield nuclear detonation in a heavily populated area. Quick non-destructive methods of predicting the quality of the sample before it is analyzed in detail are essential for efficient post-event collections. In this work, the process of exporting Defense Land Fallout Interpretive Code (DELFIC) results into Gamma Detector Response and Analysis Software (GADRAS) has been automated within the Fallout Analysis Tool. This coupling allows for the simulation of detector responses to fallout samples with varying degrees of fractionation. The degree to which the samples are fractionated depends on the location of the samples in the fallout field. In the following study, this phenomenon is examined, as its understanding is important to the investigation of debris distribution. The simulated detector spectra from GADRAS can be used to compare peak ratios of volatile-refractory isotope pairs in order to determine the degree of fractionation. Simulated fractionated fallout samples from DELFIC for a 10 kt, pure 235U fission surface burst were modeled for distances ranging to 256 km out from ground zero, and for times up to 1 week from detonation. The fractionation ratios, also known as r values, from isotope concentrations, photon lines and peak areas of four volatile-refractory pairs were calculated and compared. Fractionation prediction via the peak areas method was evaluated for each pair by comparing the results with the simulated radionuclide inventory.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Spent nuclear fuel reprocessing modeling

The long-term wide development of nuclear power requires new approaches towards the realization of nuclear fuel cycle, namely, closed nuclear fuel cycle (CNFC) with respect to fission materials. Plant nuclear fuel cycle (PNFC), which is in fact the reprocessing of spent nuclear fuel unloaded from the reactor and the production of new nuclear fuel (NF) at the same place together with reactor plant, can be one variant of CNFC. Developing and projecting of PNFC is a complicated high-technology innovative process that requires modern information support. One of the components of this information support is developed by the authors. This component is the programme conducting calculations for various variants of process flow sheets for reprocessing SNF and production of NF. Central in this programme is the blocks library, where the blocks contain mathematical description of separate processes and operations. The calculating programme itself has such a structure that one can configure the complex of blocks and correlations between blocks, appropriate for any given flow sheet. For the ready sequence of operations balance calculations are made of all flows, i.e. expenses, element and substance makeup, heat emission and radiation rate are determined. The programme is open and the block library can be updated. This means that more complicated and detailed models of technological processes will be added to the library basing on the results of testing processes using real equipment, in test operating mode. The development of the model for the realization of technical-economic analysis of various variants of technologic PNFC schemes and the organization of 'operator's advisor' is expected. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Lessons Learned in the Development of Industry Guidance - 20279

The availability of industry guidance on different aspects of waste management forms a valuable reference for waste practitioners. The guidance typically details the principles, processes and practices that should be consulted during each stage of the relevant activities. It also includes relevant regulatory and international requirements, appropriate case studies and examples of best practices to illustrate technical concepts and make the information available to the reader in an accessible manner. Over recent years Wood have developed (or are developing) a number of industry guidance documents on a range of topics including Solid Waste Characterization, Routine Water Quality Monitoring on Nuclear Sites: Pipeline Characterization: Determining Background Radioactivity for Land Quality Assessment: Interim Storage and Aqueous Waste Management. This talk provides an overview of lessons learned along the way including: - the importance of stakeholder engagement through the process: - how to identify 'good practice'; - the importance of iterative development; and - the selection of illustrative and informative case studies. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Technical Report - Final report

This project was a collaborative effort between Dr Teresa Burns and Dr John Larese to study the physisorption of polar molecules on ionic substrates. The work will be completed at both Coastal Carolina University and Brookhaven National Laboratory. The goals of the research are: 1) to provide detailed thermodynamic information about dipolar molecules adsorbed on ionic substrates, critical to accurately modeling the systems of interest using a spin-1 Ising model; 2) to study the structure of the adsorbed layer from the gas phase, experimentally verifying the application of the model to these systems; 3) to extend the modeling studies and structural measurements to systems adsorbed from the liquid phase. The systems will be studied using thermodynamic techniques, e.g., adsorption isotherm both from the gas and liquid phase, and x-ray structural measurements. This project will strengthen the physical science research efforts at CCU, and hence in South Carolina.

36 MATERIALS SCIENCE↗

Electron Tomography of Cryo-Immobilized Plant Tissue: A Novel Approach to Studying 3D Macromolecular Architecture of Mature Plant Cell Walls In Situ

Cost-effective production of lignocellulosic biofuel requires efficient breakdown of cell walls present in plant biomass to retrieve the wall polysaccharides for fermentation. In-depth knowledge of plant cell wall composition is therefore essential for improving the fuel production process. The precise spatial three-dimensional (3D) organization of cellulose, hemicellulose, pectin and lignin within plant cell walls remains unclear to date since the microscopy techniques used so far have been limited to two-dimensional, topographic or low-resolution imaging, or required isolation or chemical extraction of the cell walls. In this paper we demonstrate that by cryo-immobilizing fresh tissue, then either cryo-sectioning or freeze-substituting and resin embedding, followed by cryo- or room temperature (RT) electron tomography, respectively, we can visualize previously unseen details of plant cell wall architecture in 3D, at macromolecular resolution (~2 nm), and in near-native state. Qualitative and quantitative analyses showed that wall organization of cryo-immobilized samples were preserved remarkably better than conventionally prepared samples that suffer substantial extraction. Lignin-less primary cell walls were well preserved in both self-pressurized rapidly frozen (SPRF), cryo-sectioned samples as well as high-pressure frozen, freeze-substituted and resin embedded (HPF-FS-resin) samples. Lignin-rich secondary cell walls appeared featureless in HPF-FS-resin sections presumably due to poor stain penetration, but their macromolecular features could be visualized in unprecedented details in our cryo-sections. While cryo-tomography of vitreous tissue sections is currently proving to be instrumental in developing 3D models of lignin-rich secondary cell walls, here we confirm that the technically easier method of RT-tomography of HPF-FS-resin sections could be used immediately for routine study of low-lignin cell walls. As a proof of principle, we characterized the primary cell walls of a mutant (cob-6) and wild type Arabidopsis hypocotyl parenchyma cells by RT-tomography of HPF-FS-resin sections, and detected a small but significant difference in spatial organization of cellulose microfibrils in the mutant walls.

59 BASIC BIOLOGICAL SCIENCES↗

Goff55 Well

CT and core logger data from the Nathan Goff #55 well, Brown Lumberport Field, and is comprised primarily of the Marcellus Formation from depths of 7,043 to 7,235.75 ft. For full details please see Brown, S.; Crandall, D.; Moore, J.; Mackey, P.; Martin, K.; Carr, T. CT Scanning and Geophysical Measurements of the Marcellus Formation from the Nathan Goff #55 Well; NETL-TRS-10-2018; NETL Technical Report Series; U.S. Department of Energy, National Energy Technology Laboratory: Morgantown, WV, 2018; p 48. DOI: 10.18141/1436857.

Computed Tomography↗

Retrofitting Air Conditioning and Duct Systems in Hot, Dry Climates

This technical report describes CARB's work with Clark County Community Resources Division in Las Vegas, Nevada, to optimize procedures for upgrading cooling systems on existing homes in the area to implement health, safety, and energy improvements. Detailed monitoring of five AC systems showed that three of the five systems met or exceeded air flow rate goals.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Documentation of the LLNL, TAFB and TSL Micro-Computed-Tomography Systems

This document details the microCT data collection systems in use at the Transportation Security Laboratory, Lawrence Livermore National Laboratory, and Tyndall Air Force Base for homemade explosive characterization. X-ray source, detector, and motional control hardware are specified as well as specimen platforms, containers, and reference material types. Most of the details on the LLNL and Tyndall systems are derived from References 2 and 3. The steps that constitute the raw data processing and CT reconstruction are also recorded. Sources for further information on the processing, and technical subsystems, are given in the Section 3 References.

47 OTHER INSTRUMENTATION↗

Retrofitting Air Conditioning and Duct Systems in Hot, Dry Climates

This technical report describes CARB's work with Clark County Community Resources Division in Las Vegas, Nevada, to optimize procedures for upgrading cooling systems on existing homes in the area to implement health, safety, and energy improvements. Detailed monitoring of five AC systems showed that three of the five systems met or exceeded air flow rate goals.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

SkyMine Beneficial CO 2 Use Project

This Final Report addresses accomplishments achieved during Phase 1 and Phase 2 of the SkyMine® Carbon Mineralization Commercial Scale Pilot Project. The primary objectives of this project were to design, construct, and operate a system to capture CO₂ from a slipstream of flue gas from a commercial coal-fired cement kiln, convert that CO₂ into products having commercial value as an example of Carbon Capture and Beneficial Re-Use, show the economic viability of the CO₂ capture and conversion process, and thereby advance the technology to a level of commercial scale completion with the ability for further proliferation. The project also substantiates market opportunities for the technology by sales of chemicals into existing markets, and has identified opportunities to improve technology performance and reduce costs during the normal course of operations. The primary objectives of Phase 1 of the project were to elaborate proven SkyMine® process chemistry to commercial pilot-scale operation and complete the preliminary design for the pilot plant to be built and operated in Phase 2. During Phase 2, Pilot System Engineering Design, Construction and Testing, supporting research and development was conducted at a field test unit to collect data that aided in detailed designs of the commercial scale pilot unit; final detailed designs were completed; the commercial scale pilot plant is in its final stages of construction; and a test program has been designed and will be implemented to collect data from the facility to evaluate the technical viability of the process for resulting in an overall net reduction in CO 2 emitted into the atmosphere through a process that is run and conducted in a carbon negative manner. The objective of Phase 2b was to build the commercial scale pilot plant to be operated and tested in Phase 2c. By June 30, 2015, the plant was +99% constructed and completed.

54 ENVIRONMENTAL SCIENCES↗

IEA Wind TCP Task 37: Definition of the IEA 15-Megawatt Offshore Reference Wind Turbine

This report describes a 15-megawatt offshore wind turbine with a fixed-bottom monopile support structure. This reference wind turbine is a Class IB direct-drive machine, with a rotor diameter of 240 meters and a hub height of 150 meters. An overview of the design is presented in Figure ES-1 and Table ES-1. The design reflects a joint effort between the National Renewable Energy Laboratory, sponsored by the U.S. Department of Energy, and the Technical University of Denmark, sponsored by the European Union's H2020 Program, through the second work package of International Energy Agency Wind Task 37 on Wind Energy Systems Engineering: Integrated RD&D. A forthcoming report will detail a semisubmersible floating support structure developed by the University of Maine.

15 MW↗

The material challenges of the next generation of concentrated solar power

This is an introductory seminar about the cleantech-to-market pathway with a focus on material innovation in Concentrated Solar Power. This seminar will first lay out the business model of cleantech companies to identify the players in technical innovation. With a summary of the desires of the major player, this seminar will dive into the possibility, potential, and challenges of next-generation Concentrated Solar Power to answer these desires, followed by a detailed discussion on the material challenges. The scope of our project “Scalable, Infiltration-Free Ceramic Matrix Composite for the molten salt receiver” will be presented as one potential way to solve these challenges. In the end, this seminar will present some job opportunities to inspire the audience to participate in cleantech innovation.

42 ENGINEERING↗

IM3 Projected US Data Center Locations

IM3 Projected US Data Center Locations This dataset contains model projections of new data center facilities in the contiguous United States (CONUS) through 2035 using the CERF – Data Centers model. Data center locations are modeled across four data center electricity demand growth scenarios (low, moderate, high, higher) and five market gravity scenarios (0%, 25%, 50%, 75%, 100%). Projected locations are intended to be regional representations of feasible siting locations in the future to assess potential grid and water stress impacts. The data center load growth scenarios correspond with the rates outlined in EPRI (2024) and include 3.71%, 5%, 10%, and 15% annual growth of electricity demand for data centers from 2023 values in 37 states across the CONUS. Market gravity scenarios correspond to the relative importance of proximity to data center markets or high population areas compared to locational cost in the siting algorithm. 0% market gravity means that siting decisions were entirely determined by the locational cost in each feasible location. 100% market gravity means that only market proximity was considered when siting. Other scenarios have weight placed on both components where total weight always equals 100%. Locational cost is dependent on facility cooling type and corresponding electricity cost, taxes, and other factors. Facility cooling type is spatially determined where high water stress and/or areas with high summer wet bulb temperatures are assumed to operate with mechanical cooling for a higher fraction of the year rather than evaporative cooling. Feasible data center siting areas are based on geospatial suitability raster data developed with open-source information. The following areas are excluded from siting: Areas within 300 m of a federal airport runway Waterbodies Areas with slope >16% Areas susceptible to sinkholes High coastal or inland flood risk areas Local, state, and federal parks, leisure areas, and cemeteries Areas >2 km away from electric substations Areas >5 km away from a municipal water supplier service area Areas >2 km away from high-speed fiber provider service territory Protected Areas Database of the United States (PAD-US) areas Railroads, major roadways, and minor roadways Military areas and training grounds NLCD developed lands Areas >0.8 km (0.5 miles) from NLCD developed lands Because we use open-source information, proprietary information that can influence siting decisions such as individual tax agreements with cities, detailed fiber line connectivity, electric grid power capacity agreements, and others, are not currently accounted for in the modeling process. Using specific building locations and footprints in the dataset for local planning purposes is not advised. Technical Information Geospatial data is provided in geojson format using the Albers Equal Area Conic (ESRI:102003) coordinate reference system. The datasets contain the following parameters: id - unique identification number within given scenario file growth_scenario – data center demand growth scenario market_gravity_weight – market gravity weight scenario (%) region – name of region (i.e., US State) total_cost_million_usd – locational siting cost ($million) campus_size_square_ft – total land acquired for data center facility (square ft) data_center_it_power_mw – IT power of data center facility (MW) mechanical_cooling_frac – fraction of year when data center uses mechanical cooling system water_cooling_frac– fraction of year when data center uses evaporative cooling system cooling_energy_demand_mwh – total annual facility energy demand for cooling (MWh) cooling_water_demand_mgy – total annual facility water demand for cooling (MG) cooling_water_consumption_mgy – total annual facility water consumed (MG) normalized_locational_cost – normalized total locational cost score for location normalized_gravity_score – normalized market gravity score for location weighted_siting_score – total weighted siting score of locational cost and gravity score geometry – polygon geometry of facility Acknowledgment IM3 is a multi-institutional effort led by Pacific Northwest National Laboratory and supported by the U.S. Department of Energy's Office of Science as part of research in MultiSector Dynamics, Earth and Environmental Systems Modeling Program. License This data is made available under a CCBY4.0 License Disclaimer This material was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor the United States Department of Energy, nor the Contractor, nor any or their employees, nor any jurisdiction or organization that has cooperated in the development of these materials, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness or any information, apparatus, product, software, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof, or Battelle Memorial Institute. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof. PACIFIC NORTHWEST NATIONAL LABORATORYoperated byBATTELLEfor theUNITED STATES DEPARTMENT OF ENERGYunder Contract DE-AC05-76RL01830

Mongird, Kendall (ORCID:0000000328077088)↗

IM3 Projected US Data Center Locations

IM3 Projected US Data Center Locations This dataset contains model projections of new data center facilities in the contiguous United States (CONUS) through 2035 using the CERF – Data Centers model. Data center locations are modeled across four data center electricity demand growth scenarios (low, moderate, high, higher) and five market gravity scenarios (0%, 25%, 50%, 75%, 100%). Projected locations are intended to be regional representations of feasible siting locations in the future to assess potential grid and water stress impacts. The data center load growth scenarios correspond with the rates outlined in EPRI (2024) and include 3.71%, 5%, 10%, and 15% annual growth of electricity demand for data centers from 2023 values in 37 states across the CONUS. Market gravity scenarios correspond to the relative importance of proximity to data center markets or high population areas compared to locational cost in the siting algorithm. 0% market gravity means that siting decisions were entirely determined by the locational cost in each feasible location. 100% market gravity means that only market proximity was considered when siting. Other scenarios have weight placed on both components where total weight always equals 100%. Locational cost is dependent on facility cooling type and corresponding electricity cost, taxes, and other factors. Facility cooling type is spatially determined where high water stress and/or areas with high summer wet bulb temperatures are assumed to operate with mechanical cooling for a higher fraction of the year rather than evaporative cooling. Feasible data center siting areas are based on geospatial suitability raster data developed with open-source information. The following areas are excluded from siting: Areas within 300 m of a federal airport runway or within an airport area boundary Waterbodies Areas with slope >16% Areas susceptible to sinkholes High coastal or inland flood risk areas Local, state, and federal parks, leisure areas, and cemeteries Areas >2 km away from electric substations Areas >5 km away from a municipal water supplier service area Areas >2 km away from high-speed fiber provider service territory USGS Protected Areas Database of the United States (PAD-US) GAP status 1, 2, or 3 areas US National Parks Wetlands USFWS critical habitats BIA land areas Railroads, major roadways, and minor roadways Military areas and training grounds NLCD developed lands Areas >0.8 km (0.5 miles) from NLCD developed lands Because we use open-source information, proprietary information that can influence siting decisions such as individual tax agreements with cities, detailed fiber line connectivity, electric grid power capacity agreements, and others, are not currently accounted for in the modeling process. Using specific building locations and footprints in the dataset for local planning purposes is not advised. Technical Information Geospatial data is provided in geojson format using the Albers Equal Area Conic (ESRI:102003) coordinate reference system. The datasets contain the following parameters: id - unique identification number within given scenario file growth_scenario – data center demand growth scenario market_gravity_weight – market gravity weight scenario (%) region – name of region (i.e., US State) total_cost_million_usd – locational siting cost ($million) campus_size_square_ft – total land acquired for data center facility (square ft) data_center_it_power_mw – IT power of data center facility (MW) mechanical_cooling_frac – fraction of year when data center uses mechanical cooling system water_cooling_frac– fraction of year when data center uses evaporative cooling system cooling_energy_demand_mwh – total annual facility energy demand for cooling (MWh) cooling_water_demand_mgy – total annual facility water demand for cooling (MG) cooling_water_consumption_mgy – total annual facility water consumed (MG) normalized_locational_cost – normalized total locational cost score for location normalized_gravity_score – normalized market gravity score for location weighted_siting_score – total weighted siting score of locational cost and gravity score geometry – polygon geometry of facility Acknowledgment IM3 is a multi-institutional effort led by Pacific Northwest National Laboratory and supported by the U.S. Department of Energy's Office of Science as part of research in MultiSector Dynamics, Earth and Environmental Systems Modeling Program. License This data is made available under a CCBY4.0 License Disclaimer This material was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor the United States Department of Energy, nor the Contractor, nor any or their employees, nor any jurisdiction or organization that has cooperated in the development of these materials, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness or any information, apparatus, product, software, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof, or Battelle Memorial Institute. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof. PACIFIC NORTHWEST NATIONAL LABORATORYoperated byBATTELLEfor theUNITED STATES DEPARTMENT OF ENERGYunder Contract DE-AC05-76RL01830

Mongird, Kendall (ORCID:0000000328077088)↗

LID and LeTID Impacts to PV Module Performance and System Economics: Draft Analysis

This webinar is a technical review of the measurements and causes of BO LID, UV LID and LeTID, as well as modeling their impacts to PV project financial metrics. We will first review how Boron-Oxygen complexes form and detail the range of impacts to PV module power ratings over time and across climates. Similarly, we will also discuss the measurements and extent of UV LID over time and across climates. Then, we will demonstrate a methodology for translating these effects to pro forma cash flow models and their impacts to PV project financial returns and levelized cost of electricity (LCOE). We will conclude with estimates of the value of solutions to these degradation mechanisms.

41 EE - Solar Energy Technologies Office (EE-4S)↗

The root causes of siting failures in nuclear waste management - 15652

For many decades, the global nuclear industry and associated governments have attempted to establish new facilities for the storage and disposal of nuclear wastes. Success has been rare (France, Sweden and Finland being the examples) and remains elusive for many programs despite attempts to change the selection process in some cases. Success has been aided by local and national consent in the few cases that are proceeding. A small study of several countries lack of success is examined to determine the dominant reasons for such failures. The goal of the study is to inform the planning process for efforts to site new facilities by feeding back some lessons learned from past failed efforts. This limited review of international experience indicates that there is no simple approach available for siting deep geologic disposal or even centralized storage facilities. A number of countries have tried multiple times to find an acceptable site. Two studies [1, 2] clearly indicate that there must be adequate assurance of social as well as technical acceptability for successfully siting such facilities. It is evident that even though the technology and science may be proven, it is the politics and public engagement in siting processes that dominate the failures. However, the detailed reasons within each effort present a richer set of lessons. This paper will summarize the findings and present them such that they can be used to inform future siting efforts by a nation. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Economics of Current and Future Biofuels

This work presents detailed comparative analysis on the production economics of both current and future biofuels, including ethanol, biodiesel, and butanol. Our objectives include demonstrating the impact of key parameters on the overall process economics (e.g., plant capacity, raw material pricing, and yield) and comparing how next-generation technologies and fuels will differ from today's technologies. The commercialized processes and corresponding economics presented here include corn-based ethanol, sugarcane-based ethanol, and soy-based biodiesel. While actual full-scale economic data are available for these processes, they have also been modeled using detailed process simulation. For future biofuel technologies, detailed techno-economic data exist for cellulosic ethanol from both biochemical and thermochemical conversion. In addition, similar techno-economic models have been created for n-butanol production based on publicly available literature data. Key technical and economic challenges facing all of these biofuels are discussed.

09 BIOMASS FUELS↗