Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “System Identification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

One Electron Multiple Proton Transfer in Model Organic Donor–Acceptor Systems: Implications for High-Frequency EPR

EPR spectroscopy is an important spectroscopic method for identification and characterization of radical species involved in many biological reactions. The tyrosyl radical is one of the most studied amino acid radical intermediates in biology. Often in conjunction with histidine residues, it is involved in many fundamental biological electron and proton transfer processes, such as in the water oxidation in photosystem II. As biological processes are typically extremely complicated and hard to control, molecular bio-mimetic model complexes are often used to clarify the mechanisms of the biological reactions. In this work, we present theoretical calculations to investigate the sensitivity of magnetic resonance parameters to proton-coupled electron transfer events, as well as conformational substates of the molecular constructs which mimic the tyrosine-histidine (Tyr-His) pairs found in a large variety of proteins. Upon oxidation of the phenol, the Tyr analog, these complexes can perform not only one-electron one-proton transfer (EPT), but also one-electron two-proton transfers (E2PT). It is shown that in aprotic environment the g X -components of the electronicg-tensor are extremely sensitive to the first proton transfer from the phenoxyl oxygen to the imidazole nitrogen (EPT product), leading to a significant increase of the g X -value of up to 0.003, but are not sensitive to the second proton transfer (E2PT). In the latter case, the change of the g X -value is much smaller (ca. 0.0001), which is too small to be distinguished even by high-frequency EPR. The 14 N hyperfine values are also too similar to allow differentiation between the different protonation states in EPT and E2PT. The magnetic resonance parameters were also calculated as a function of the rotation angles around single bonds. It was demonstrated that rotation of the phenoxyl group results in large positive changes (> 0.001) in the g X -values. Analysis of the data reveals that the main source of these changes is related to the strength of the H-bond between phenoxyl oxygen and the proton(s) on N 1 and N 2 positions of the imidazole.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Residential retrofits at scale: opportunity identification, saving estimation, and personalized messaging based on communicating thermostat data

Basic insulation and heating system retrofits of existing homes could achieve annual energy savings of up to $4–5 billion in the USA. However, current US utility energy efficiency (EE) programs are costly and challenging to scale. Customer acquisition occurs primarily through energy bill mailers, mass media, and on-line advertising that lack specificity about particular home retrofit opportunities, expected energy savings, and cost-effectiveness. Specific retrofit opportunities are identified via on-site home energy assessments that can be inconvenient to homeowners, expensive, and of variable accuracy. Our paper discusses using communicating thermostat data to significantly increase the customer uptake of energy conservation measures (ECMs) by identifying homes with the most significant retrofit opportunities, estimating post-retrofit energy savings, and formulating home-specific outreach. We extended our previously developed gray-box building model to identify physical building parameters corresponding to the target retrofit opportunities, i.e., whole-home R value, air leakage characteristics, and heating system efficiency. Here, the estimated R values and air leakage characteristics compare favorably with the ground truth. The validated algorithms can calculate home-specific energy savings estimate for each ECM, and the algorithm outputs can be used by utility EE programs to formulate home-specific retrofit offers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Reconstructing the membrane detection of a 1D electrostatic-driven MEMS device by the shooting method: convergence analysis and ghost solutions identification

In this paper, in the domain of 1D-membrane micro-electro-mechanical systems in which the electrostatic field is expressed in terms of geometric curvature of the membrane, we present a numerical approach based on shooting techniques to reconstruct the membrane profile in the device in steady-state case. In particular, starting from known results in literature about existence achieved by Schauder–Tychonoff’s fixed point approach and uniqueness, and focusing on two physical–mathematical parameters appropriately indicative of the applied voltage and electromechanical properties of the membrane, respectively, we will discuss what operation parameters (applied voltage, amplitude of electrostatic field) and for which electromechanical membrane characteristic of the device is permitted or not a convergence of the method with respect to analytical results. Finally, we will discuss in detail the detected ghost solutions.

97 MATHEMATICS AND COMPUTING↗

Application of Failure Mode and Effects Analysis to Intraoperative Radiation Therapy Using Mobile Electron Linear Accelerators

Purpose: Failure mode and effects analysis (FMEA) represents a prospective approach for risk assessment. A multidisciplinary working group of the Italian Association for Medical Physics applied FMEA to electron beam intraoperative radiation therapy (IORT) delivered using mobile linear accelerators, aiming at preventing accidental exposures to the patient. Methods and Materials: FMEA was applied to the IORT process, for the stages of the treatment delivery and verification, and consisted of three steps: 1) identification of the involved subprocesses; 2) identification and ranking of the potential failure modes, together with their causes and effects, using the risk probability number (RPN) scoring system, based on the product of three parameters (severity, frequency of occurrence and detectability, each ranging from 1 to 10); 3) identification of additional safety measures to be proposed for process quality and safety improvement. RPN upper threshold for little concern of risk was set at 125. Results: Twenty-four subprocesses were identified. Ten potential failure modes were found and scored, in terms of RPN, in the range of 42-216. The most critical failure modes consisted of internal shield misalignment, wrong Monitor Unit calculation and incorrect data entry at treatment console. Potential causes of failure included shield displacement, human errors, such as underestimation of CTV extension, mainly because of lack of adequate training and time pressures, failure in the communication between operators, and machine malfunctioning. The main effects of failure were represented by CTV underdose, wrong dose distribution and/or delivery, unintended normal tissue irradiation. As additional safety measures, the utilization of a dedicated staff for IORT, double-checking of MU calculation and data entry and finally implementation of in vivo dosimetry were suggested. Conclusions: FMEA appeared as a useful tool for prospective evaluation of patient safety in radiotherapy. The application of this method to IORT lead to identify three safety measures for risk mitigation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Synchro-Waveform-Based Event Identification Using Multi-Task Time-Frequency Transform Networks

Influenced by the transient dynamics and reduced inertia characteristics of high-penetration renewable energy systems, power system events frequently exhibit distinct characteristics such as high-frequency components including wide-band oscillations and hyper-harmonics. This makes standard systems face challenges including significant latency and reduced accuracy due to limited data resolution. However, current methods face significant limitations, including insufficient pattern capture ability, low noise immunity, limited feature learning, and restricted localization capabilities, thereby hindering real-time performance. To tackle this issue, this paper proposed a novel synchro-waveform-based event identification approach via a Multi-task Time-frequency Transform Network (MTTNet). Initially, a Time-frequency Transform Block (TTB) is developed to extract both local and global information. The TTB leverages both Fourier and S-transforms to derive comprehensive time-frequency information from synchro-waveforms. Subsequently, a multi-task learning strategy is employed to identify the type and distinguish localization of events. Integrating the TTB and multi-task learning, the MTTNet is designed for synchro-waveform-based event identification, incorporating an adaptive weighting strategy and simplified computation for the S-transform. Two different datasets, comprising simulated and actual synchro-waveforms, are collected from the IEEE 123 bus system and a real-world high-penetration renewable energy system using a universal grid analyzer. Extensive experiments on various conditions are carried out. In conclusion, results demonstrated that the MTTNet consistently surpasses both basic and advanced baselines, with maximum improvements of 13.24% and 9.86%, respectively, while reducing the calculation burden by 15-19 times to achieve real-time event identification.

Event identification↗

Unsupervised Process Anomaly Detection and Identification Using the Leave-One-Variable-Out Approach

Automated anomaly detection and identification can signal equipment issues and pinpoint causes in large-scale industrial systems. For systems with limited failure history, unsupervised machine learning methods can be utilized as they do not require past failures. This study introduces the leave-one-variable-out (LOVO) model, which masks one variable at a time to predict the others, learning underlying process correlations. Detection performance was assessed with synthetic and experimental data, while identification performance used only synthetic data due to its ability to generate labeled anomaly types. For detection using synthetic data, the LOVO model generally outperformed comparative models; while using experimental data, the comparative methods outperformed the LOVO model. However, the comparative methods required selecting a latent size, and these conclusions pertain to using the optimal size. In practice, it would not be feasible to always select the optimal value, and incorrect selections impacted performance. In contrast, the LOVO model does not require a latent space. For identification using synthetic data, the LOVO model was slightly outperformed in interpretability and repeatability but still demonstrated impressive results. These outcomes suggest that the LOVO model is an effective model and may be more easily implemented without the challenging tuning process of selecting a latent size.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detection of False Data Injection Attacks in Battery Stacks Using Input Noise-Aware Nonlinear State Estimation and Cumulative Sum Algorithms

Grid-scale battery energy storage systems (BESSs) are vulnerable to false data injection attacks (FDIAs), which could be used to disrupt state of charge (SoC) estimation. Inaccurate SoC estimation has negative impacts on system availability, reliability, safety, and the cost of operation. In this article a combination of a Cumulative Sum (CUSUM) algorithm and an improved input noise-aware extended Kalman filter (INAEKF) is proposed for the detection and identification of FDIAs in the voltage and current sensors of a battery stack. The series-connected stack is represented by equivalent circuit models, the SoC is modeled with a charge reservoir model and the states are estimated using the INAEKF. Further, the root mean squared error of the states’ estimation by the modified INAEKF was found to be superior to the traditional EKF. By employing the INAEKF, this article addresses the research gap that many state estimators make asymmetrical assumptions about the noise corrupting the system. Additionally, the INAEKF estimates the input allowing for the identification of FDIA, which many alternative methods are unable to achieve. The proposed algorithm was able to detect attacks in the voltage and current sensors in 99.16% of test cases, with no false positives. Utilizing the INAEKF compared to the standard EKF allowed for the identification of FDIA in the input of the system in 98.43% of test cases.

25 ENERGY STORAGE↗

Advances in scientific literature mining for interpreting materials characterization

Abstract Using synchrotron light sources, such as the National Synchrotron Light Source II at Brookhaven National Laboratory, scientists in fields as diverse as physics, biology, and materials science, identify the atomic structure, chemical composition, or other important properties of varied specimens. x-ray spectroscopy from light sources is particularly valuable for materials research with vast information available about reference spectra in the scientific literature. However, as the technique is applicable to many science domains, searching for information about select x-ray spectroscopy spectra is impeded by the sheer number of publications. Moreover, useful information about the context of an experiment or figures presented in papers can be buried among the details, which takes time to assess. This work presents a scientific literature mining system that supports data acquisition, information extraction, and user interaction for referencing x-ray spectra identification and spectral interpretation. The goal is to provide efficient access to useful spectral data to researchers who may spend only a few days at a synchrotron light source. With this system, users browse a classification tree for papers arranged according to x-ray spectroscopic methods, chemical elements, and x-ray absorption spectroscopy edges. Relevant figures are extracted with sentences from the paper that explain them, known as ‘figure explanatory text.’ Notably, this system focuses on semantic aspects (logical analysis) to find figure explanatory text using deep contextualized word embeddings techniques and contains an interface to obtain labeled data from domain experts that is used to evaluate and improve the model.

Park, Gilchan (ORCID:0000000201536646)↗

Preliminary LOCA analysis of the westinghouse small modular reactor using the WCOBRA/TRAC-TF2 thermal-hydraulics code

The Westinghouse Small Modular Reactor (SMR) is an 800 MWt (> 225 MWe) integral pressurized water reactor (iPWR) with all primary components, including the steam generator and the pressurizer located inside the reactor vessel. The reactor core is based on a partial-height 17x17 fuel assembly design used in the AP1000{sup R} reactor core. The Westinghouse SMR utilizes passive safety systems and proven components from the AP1000 plant design with a compact containment that houses the integral reactor vessel and the passive safety systems. A preliminary loss of coolant accident (LOCA) analysis of the Westinghouse SMR has been performed using the WCOBRA/TRAC-TF2 code, simulating a transient caused by a double ended guillotine (DEG) break in the direct vessel injection (DVI) line. WCOBRA/TRAC-TF2 is a new generation Westinghouse LOCA thermal-hydraulics code evolving from the US NRC licensed WCOBRA/TRAC code. It is designed to simulate PWR LOCA events from the smallest break size to the largest break size (DEG cold leg). A significant number of fluid dynamics models and heat transfer models were developed or improved in WCOBRA/TRAC-TF2. A large number of separate effects and integral effects tests were performed for a rigorous code assessment and validation. WCOBRA/TRAC-TF2 was introduced into the Westinghouse SMR design phase to assist a quick and robust passive cooling system design and to identify thermal-hydraulic phenomena for the development of the SMR Phenomena Identification Ranking Table (PIRT). The LOCA analysis of the Westinghouse SMR demonstrates that the DEG DVI break LOCA is mitigated by the injection and venting from the Westinghouse SMR passive safety systems without core heat up, achieving long term core cooling. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Nuclear Interdiction Through Relocatable Detectors

The NNSA Office of Nuclear Smuggling Detection and Deterrence (NSDD) has investigated a set of minimal-infrastructure radiation detection systems as alternatives to fixed Radiation Portal Monitors (RPMs) for nuclear interdiction applications. These versatile and relocatable systems can improve nuclear security in missions or locations that do not warrant or support a standard fixed radiation detection system. Over 2019, a variety of relocatable detectors were characterized at the Interdiction Technologies Integration Laboratory at Pacific Northwest National Laboratory (PNNL). Evaluated detectors were diverse in their size and capabilities, ranging from backpack-sized systems to lane-spanning cargo scanning portals. Both spectroscopic and non-spectroscopic pedestrian and vehicle detection systems were characterized against uranium and plutonium sources. Signatures from the sources were modulated by both shielding and distance to quantify the performance of the relocatable systems as signal strength was decreased. Findings showed that relocatable spectroscopic detectors with isotope identification capabilities could reduce nuisance alarm rates compared to conventional fixed installation, gross-counting, radiation portal monitors. In vehicle scanning applications, detection ability generally trended with detection volume, regardless of spectral capability. In pedestrian scanning applications, several smaller backpack-sized detector systems were found to be more sensitive to detecting material than pedestrian portal monitors. The results of this characterization effort have helped inform the deployment of versatile equipment to improve nuclear security missions.

relocatable detectors, Nuclear Security↗

Measurement-based Power System Dynamic Model Reductions

Interconnected power systems have experienced a significant increase in its size and complexity, due to continuous topology and operating condition changes. It is computationally burdensome to represent entire system models in detail to conduct power system analysis. In the large-scale power system dynamic simulations, the models in the study area need to be retained in detail while the external area can be reduced without compromising accuracy, which can preserve the full system dynamic properties. This paper develops measurement-based continuous-time dynamic equivalents for power systems in order to both improve the model accuracy of the reduced system and increase the speed of dynamic simulation. Our method is based on a set of measurements at the boundary nodes between the study area and external area. Case studies demonstrate that the measurement-based model can capture the full system behavior sufficiently, and improve computational efficiency.Interconnected power systems experienced a significant increase in size and complexity. It is computationally burdensome to represent the entire system in detail to conduct power system analysis. Therefore, the model of the study system must be retained in detail while the external system can be reduced using system reduction techniques. This paper proposes a measurement-based dynamic equivalent in order to increase both model accuracy and simulation speed. The proposed method uses a set of measurements at the boundary nodes between the study area and external area for model parameter identification. Case studies demonstrate that the measurement-based technique can capture the main system behaviors accurately and improve computational efficiency.

Xue, Yaosuo↗

How systems engineering and human factors can assist SMR vendors with the licensing process - 345

There is growing interest in the development of small modular reactors (SMRs) as a cost-effective renewable source of energy. Most of the current conceptual designs propose advanced and automated control and monitoring technologies which would require complex human system interfaces. The proposals also include a reduction in the number of staff, and partial or full remote control of the facilities. The human factors challenges of such a design philosophy range from identification of information requirements of users to assessing workload to deciding on best information visualization techniques to ensure situation awareness is maintained in a remote control facility. Addressing these challenges will require a systems engineering approach where user requirements are identified through a systematic approach for various contexts, including normal, abnormal, and accident conditions. A systems engineering process will integrate human factors as well as other specialty disciplines such as reliability and design optimization in a coherent fashion that would lead to realization of a successful system that addresses user requirements. The licensing model in Canada is based upon a graded approach and is largely technology neutral. A key factor in ensuring effective licensing effort is identification of regulatory requirements. This paper discusses how adopting a systems engineering approach and early consideration of human factors principles and requirements will not only ensure an efficient design process, but will also help with developing a design that meets the regulatory requirements. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Reassessing the Origins and Contemporary Relevance of ck Acceptability Parameters: Evolving Perspectives on Similarity

“Sensitivity and Uncertainty Analyses Applied to Criticality Safety Validation,” introduces sensitivity and uncertainty methods to address challenges in defining and extending areas of applicability for criticality safety validation. These areas are traditionally defined by the bounds or limits on key parameters, but establishing valid ranges and managing complex parameter variations remain challenging. NUREG/CR-6655 introduces ck and other integral indices, as well as concepts such as the completeness of benchmark coverage, to better quantify system similarities. The work proposed herein seeks to evaluate these foundational concepts to ensure that the bounds remain effective in guiding the assessment of similarity and applicability in modern applications. The concept of completeness, along with other parameters envisioned within the framework, serves as an example of the foundational ideas that have been established, though their effectiveness in practice may not be fully understood. Advancements in scripting tools, coupled with the speed and efficiency of modern computing and statistical models, now allow for faster and more thorough assessments than previously possible. These advancements also enable the identification of trends within the data, which could provide additional insight into system behavior and further broaden the scope of previously performed benchmarks. By leveraging these capabilities, we will revisit and expand the scope of these foundational methods to determine whether the necessary elements for robust similarity evaluation are already embedded, partially realized, or remain untapped.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Analytical Identification Method of Generalized Short‐Circuit Ratio Using Phasor Measurement Units

This paper introduces a novel analytical approach for the identification of the admittance matrix and the generalized short-circuit ratio (gSCR) in power systems integrated with renewable energy sources. The proposed method leverages voltage and current measurements from phasor measurement units (PMUs) to construct a least squares objective function, which is then solved using matrix calculus and partial derivatives. Unlike conventional optimization algorithms, this approach provides an analytical solution that substantially reduces data requirements, enabling the efficient and accurate identification of the gSCR with smaller datasets. Additionally, its fixed computational complexity allows for real-time updates as new data are collected, ensuring continuous refinement of the system of equations and enabling rapid, precise gSCR calculations. The method also exhibits strong robustness against measurement noise, making it well-suited for practical applications in dynamic power systems. The combination of reduced data requirements, real-time adaptability, noise robustness and fixed computational load establishes this method as a highly efficient and reliable tool for real-time power system stability analysis. Case studies on an EPRI 36-bus system demonstrate the method's effectiveness, highlighting its accuracy in closely matching true gSCR values, even under diverse disturbances and noisy conditions.

Han, Zelei [Hohai University, Nanjing (China)] (OR↗

BINARY CENTRAL STARS OF PLANETARY NEBULAE DISCOVERED THROUGH PHOTOMETRIC VARIABILITY. IV. THE CENTRAL STARS OF HaTr 4 AND Hf 2-2

We explore the photometrically variable central stars of the planetary nebulae HaTr 4 and Hf 2-2. Both have been classified as close binary star systems previously based on their light curves alone. Here, we present additional arguments and data confirming the identification of both as close binaries with an irradiated cool companion to the hot central star. We include updated light curves, orbital periods, and preliminary binary modeling for both systems. We also identify for the first time the central star of HaTr 4 as an eclipsing binary. Neither system has been well studied in the past, but we utilize the small amount of existing data to limit possible binary parameters, including system inclination. These parameters are then compared to nebular parameters to further our knowledge of the relationship between binary central stars of planetary nebulae and nebular shaping and ejection.

79 ASTRONOMY AND ASTROPHYSICS↗

Performance of a Low Activity Beta-Sensitive SR{sup 90} Water Monitor for Fukushima

There are large volumes of contaminated water from the stabilization efforts at the damaged Fukushima Nuclear Power Plants. This water is being processed to remove radioactivity for eventual release to the environment. An on-line continuously operating system to confirm that the clean-up system is working properly, and to provide prompt feedback of the results is required by the system operator. While gamma emitting nuclides allow for the straight forward approach of gamma spectroscopy to identify and quantify radioactivity in water, pure beta emitting nuclides such as Sr{sup 90} pose a challenging problem. The relatively short range of beta radiation in water requires optimization of the measurement geometry in terms of the source-detector distance and source-detector interface while retaining a background sensitivity low enough to meet the Minimum Detectable Concentration (MDC) of 10 Bq/kg in 180 minutes. This issue is complicated by the continuum nature of the beta spectrum which does not allow for simple nuclide identification. The use of the Monte-Carlo code MCNP to estimate system performance before prototyping vastly increases the success of the end product. Various parameters such as detector size and thickness, water chamber size, water chamber construction materials were evaluated to help choose the optimum geometry. The final design was a system consisting of two large-area (16 x 35 cm) and thin (0.15 mm) plastic scintillators placed very close to a sealed a water chamber. The size of the chamber was optimized to obtain the maximum efficiency for the nuclide being measured (Sr/Y{sup 90}) but to minimize the efficiency for possible interferences (Ru/Rh{sup 106}, Cs{sup 137}). A thin carbon fiber window was selected with adequate material and thickness to contain the water under pressure, but also thin enough (0.5 mm) to allow enough beta radiation to pass through to the active detector volume. The entire measurement geometry is then housed in a thick lead shield to reduce contributions from external sources to an acceptable level. Data acquisition is accomplished through customized application-specific software that allows for long counting times to attain a low MDC, but also simultaneously provides alarms on short averaging times to achieve a fast response to sudden changes in activity concentration. Multiple monitors are then linked to supervisory software where real time data and alarms are available for analysis in remote locations. The system also allows for remote operation of the unit; check sources, background checks, systems settings and more may be accessed remotely. Testing of the production devices has shown that we can achieve the 10 Bk/kg MDC requirement for Sr{sup 90} in equilibrium with Y{sup 90} with a count time of approximately 20 minutes. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Calibration of Reduced Dynamic Models of Power Systems using Phasor Measurement Unit (PMU) Data

Accuracy of a power system dynamic model is essential to the secure and efficient operation of the system. Lower confidence on model accuracy usually leads to conservative operation and lowers asset usage. To improve model accuracy, identification algorithms have been developed to calibrate parameters of individual components using measurement data from staged tests. To facilitate online dynamic studies for large power system interconnections, this paper proposes a model reduction and calibration approach using phasor measurement unit (PMU) data. First, a model reduction method is used to reduce the number of dynamic components. Then, a calibration algorithm is developed to estimate parameters of the reduced model. This approach will help to maintain an accurate dynamic model suitable for online dynamic studies. The performance of the proposed method is verified through simulation studies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

THE TUCANA/HOROLOGIUM, COLUMBA, AB DORADUS, AND ARGUS ASSOCIATIONS: NEW MEMBERS AND DUSTY DEBRIS DISKS

We propose 35 star systems within {approx}70 pc of Earth as newly identified members of nearby young stellar kinematic groups; these identifications include the first A- and late-B-type members of the AB Doradus moving group and field Argus Association. All but one of the 35 systems contain a bright solar- or earlier-type star that should make an excellent target for the next generation of adaptive optics (AO) imaging systems on large telescopes. AO imaging has revealed four massive planets in orbit around the {lambda} Boo star HR 8799. Initially, the planets were of uncertain mass due in large part to the uncertain age of the star. We find that HR 8799 is a likely member of the {approx}30 Myr old Columba Association, implying planet masses {approx}6 times that of Jupiter. We consider Spitzer Space Telescope MIPS photometry of stars in the {approx}30 Myr old Tucana/Horologium and Columba Associations, the {approx}40 Myr old field Argus Association, and the {approx}70 Myr old AB Doradus moving group. The percentage of stars in these young stellar groups that display excess emission above the stellar photosphere at 24 and 70 {mu}m wavelengths-indicative of the presence of a dusty debris disk-is compared with corresponding percentages for members of 11 open clusters and stellar associations with ages between 8 and 750 Myr, thus elucidating the decay of debris disks with time.

79 ASTRONOMY AND ASTROPHYSICS↗