Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Synchrotrons”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

Use of continuous sample translation to reduce radiation damage for XPCS studies of protein diffusion

An experimental setup to measure X-ray photon correlation spectroscopy during continuous sample translation is presented and its effectiveness as a means to avoid sample damage in dynamics studies of protein diffusion is evaluated. X-ray damage from focused coherent synchrotron radiation remains below tolerable levels as long as the sample is translated through the beam sufficiently quickly. Here it is shown that it is possible to separate sample dynamics from the effects associated with the transit of the sample through the beam. By varying the sample translation rate, the damage threshold level, D thresh = 1.8 kGy, for when beam damage begins to modify the dynamics under the conditions used, is also determined. Signal-to-noise ratios, R sn ≥ 20, are obtained down to the shortest delay times of 20 µs. The applicability of this method of data collection to the next generation of multi-bend achromat synchrotron sources is discussed and it is shown that sub-microsecond dynamics should be obtainable on protein samples.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

PyPhase – a Python package for X-ray phase imaging

X-ray propagation-based imaging techniques are well established at synchrotron radiation and laboratory sources. However, most reconstruction algorithms for such image modalities, also known as phase-retrieval algorithms, have been developed specifically for one instrument by and for experts, making the development and diffusion of such techniques difficult. Here, PyPhase, a free and open-source package for propagation-based near-field phase reconstructions, which is distributed under the CeCILL license, is presented. PyPhase implements some of the most popular phase-retrieval algorithms in a highly modular framework supporting its deployment on large-scale computing facilities. This makes the integration, the development of new phase-retrieval algorithms, and the deployment on different computing infrastructures straightforward. Its capabilities and simplicity are presented by application to data acquired at the synchrotron source MAX IV (Lund, Sweden).

36 MATERIALS SCIENCE↗

A WISER way for simulating the performance of gratings

Soft X-ray monochromators for synchrotron radiation sources have been continuously developed over the years, improving energy resolution and stability. Great effort has been made in improving the surface quality of the optics involved, reaching values permitting diffraction-limited images. Still, one problem has not been solved, nor fully understood, yet: groove placing errors. Nowadays, these are one of the major factors responsible for resolving the power reduction of diffraction-gratings-based X-ray monochromators. Despite decades of use of gratings, there is not yet a universally established method for predicting and simulating the effect of groove placing errors on monochromator performance. This is especially important in the new scenario of high-coherent X-ray sources, i.e. diffraction-limited storage rings and free-electron lasers. To address this problem, in this article an approach based on WISER (Wavefront propagatIon Simulation codE libRary) is presented. WISER is a physical optics simulation package, also available in the user-friendly Orange Synchrotron Radiation Suite – OASYS. Even though it was originally conceived to assess the focusing performance of X-ray mirrors in the presence of height defects, it perfectly simulates the performance of a periodic (or quasi-periodic) structure like a diffraction grating. In this article, the way to use WISER and its application to a specific case, e.g. the design of a monochromator for the upgrade of a beamline at the Advanced Light Source, are shown. A simple rule for estimating how well the grooves are placed on a grating, based on calculation of the Strehl ratio, is also presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fixed-target serial femtosecond crystallography using in cellulo grown microcrystals

The crystallization of recombinant proteins in living cells is an exciting new approach in structural biology. Recent success has highlighted the need for fast and efficient diffraction data collection, optimally directly exposing intact crystal-containing cells to the X-ray beam, thus protecting the in cellulo crystals from environmental challenges. Serial femtosecond crystallography (SFX) at free-electron lasers (XFELs) allows the collection of detectable diffraction even from tiny protein crystals, but requires very fast sample exchange to utilize each XFEL pulse. Here, an efficient approach is presented for high-resolution structure elucidation using serial femtosecond in cellulo diffraction of micometre-sized crystals of the protein HEX-1 from the fungus Neurospora crassa on a fixed target. Employing the fast and highly accurate Roadrunner II translation-stage system allowed efficient raster scanning of the pores of micro-patterned, single-crystalline silicon chips loaded with living, crystal-containing insect cells. Compared with liquid-jet and LCP injection systems, the increased hit rates of up to 30% and reduced background scattering enabled elucidation of the HEX-1 structure. Using diffraction data from only a single chip collected within 12 min at the Linac Coherent Light Source, a 1.8 Å resolution structure was obtained with significantly reduced sample consumption compared with previous SFX experiments using liquid-jet injection. This HEX-1 structure is almost superimposable with that previously determined using synchrotron radiation from single HEX-1 crystals grown by sitting-drop vapour diffusion, validating the approach. This study demonstrates that fixed-target SFX using micro-patterned silicon chips is ideally suited for efficient in cellulo diffraction data collection using living, crystal-containing cells, and offers huge potential for the straightforward structure elucidation of proteins that form intracellular crystals at both XFELs and synchrotron sources.

Lahey-Rudolph, J. Mia (ORCID:0000000152797267)↗

Structure of ice VII with Hirshfeld atom refinement

In the refinement of the crystal structures of ice, the best results obtained so far have been with neutron diffraction because the most troublemaking aspects are the hydrogen atoms. In nine out of twenty ice structures, the hydrogen atoms are disordered, which makes proper refinement more difficult. In our previous paper describing the structure of ice VI we proved that, using Hirshfeld atom refinement (HAR) based on synchrotron X-ray data, it is possible to obtain results comparable with those from neutron experiments. In this work, we investigate another structure of high-pressure disordered ice, cubo-ice (ice VII). Single crystals of cubo-ice were grown under pressure in diamond anvil cells. X-ray diffraction measurements were conducted at a synchrotron source facility (APS, University of Chicago, USA) as well as on our regular in-house laboratory diffractometer with Ag radiation. The data collected were further refined with HAR. Comparison of the structural parameters obtained with those derived from neutron diffraction showed very good agreement in terms of bond lengths and fairly good agreement in terms of hydrogen atom ADPs. We were also able to perform unconstrained refinements with various split-atom models.

Chemistry↗

A Broadband Mechanically Tuned Superconducting Cavity Design Suitable for the Fermilab Main Injector

Radio Frequency superconductivity has been a mainstay of accelerator science for decades. However, its benefits have yet to be applied to proton synchrotrons with demanding tuning requirements. For example, the Main Injector (MI), Fermilab's high-energy proton synchrotron, currently utilizes 20+ ferrite-loaded cavities for a targeted 1.2 s acceleration cycle. Harnessing the extremely high gradients associated with superconductivity, the required number of cavities could be reduced by an order of magnitude, dramatically lowering operational power requirements even with cryogenic considerations. Additionally, the current plans for the Fermilab accelerator complex evolution initiative involve almost doubling the number of cavities in MI if the same designs are to be used, further highlighting the potential benefits of superconductivity. These advantages are attractive, but to date, no tunable superconducting cavity suitable for MI has been proposed due to the incompatibility of conventional broadband tuning methods with superconductivity. Here, we present a tunable superconducting cavity concept capable of record-breaking performance. Tuning will be accomplished by using high-speed linear actuators to vary the insertion depth of metallic plungers into the cavity volume. This tuning concept is theoretically viable with currently available technology and will be fully compatible with a superconducting cavity.

43 PARTICLE ACCELERATORS↗

Advances in High Resolution Ultrafast Scintillators for Fast timing Applications

Scintillation detectors exhibiting high spatial resolution and fast timing capabilities are of vital importance for synchrotron sources. These detectors may be exposed to a variety of X-ray energies (up to 140 keV) and used in high frame rate applications. Here, we describe the advances in the development of thin-film LuI3:Ce scintillators for higher energy X-ray imaging, with fast timing and high spatial resolution. When grown in a single crystalline form, these scintillators are bright, producing 115 000 photons/MeV. However, to achieve high spatial resolution, these scintillators are grown in thin-film form with a microcolumnar structure, controllable to column diameters of <1-30 mu m. Thus, a much thicker scintillator layer (10 mu m-3 mm or higher) may be grown, providing superior X-ray absorption while achieving high resolutions of 50 mu m or better, at the cost of reduced light yield. To study the timing characteristics of the scintillator, time-resolved X-ray excited optical luminescence (TR-XEOL) was performed on two different sets of three samples of LuI3 at the 1-BM beamline of the Advanced Photon Source at Argonne National Laboratory. Besides, we report timing measurements obtained using a photomultiplier tube (PMT) and oscilloscope at Radiation Monitoring Devices (RMD) Inc. Using the TR-XEOL, we determined the decay constants of LuI3 as a function of Ce doping, recording a fast decay component as low as 3.6 ns (39%), one of the fastest values recorded in inorganic scintillators. This fast decay opens up numerous novel applications, where ultrahigh frame rates are important using synchrotron X-rays. This article will discuss fabrication, characterization, and potential applications for this novel scintillator.

fast timing↗

Focused‐beam X‐ray fluorescence and diffraction microtomographies for mineralogical and chemical characterization of unsectioned extraterrestrial samples

Abstract This study describes the application of new synchrotron X‐ray fluorescence (XRF) and diffraction (XRD) microtomographies for the 3‐D visualization of chemical and mineralogical variations in unsectioned extraterrestrial samples. These improved methods have been applied to three compositionally diverse chondritic meteorite samples that were between 300 and 400 μm in diameter, including samples prepared from fragments of the CR2 chondrite LaPaz Icefield (LAP) 02342, H5 chondrite MacAlpine Hills (MAC) 88203, and the CM2 chondrite Murchison. The synchrotron‐based XRF and XRD tomographies used are focused‐beam techniques that measure the intensities of fluorescent and diffracted X‐rays in a sample simultaneously during irradiation by a high‐energy microfocused incident X‐ray beam. Measured sinograms of the emitted and diffracted intensities were then tomographically reconstructed to generate 2‐D slices of XRF and XRD intensity through the sample, with reconstructed pixel resolution of 1–2 μm, defined by the resolution of the focused incident X‐ray beam. For sample LAP 02342, primary mineral phases that were visualized in reconstructed slices using these techniques included isolated grains of α‐Fe, orthopyroxene, and olivine. For our sample of MAC 88203, XRF/XRD tomography allowed visualization of forsteritic olivine as a primary mineral phase, a vitrified fusion crust at the sample surface, identification of localized Cr‐rich spinels at spatial resolutions of several micrometers, and imaging of a plagioclase‐rich glassy matrix. In the sample of Murchison, major identifiable phases include clinoenstatite‐ and olivine‐rich chondrules, variable serpentine matrix minerals and small Cr‐rich spinels. Most notable in the tomographic analysis of Murchison is the ability to quantitatively distinguish and visualize the complex mixture of serpentine‐group minerals and associated tochilinite–cronstedtite intergrowths. These methods provide new opportunities for spatially resolved characterization of sample texture, mineralogy, crystal structure, and chemical state in unsectioned samples. This provides researchers an ability to characterize such samples internally with minimal disruption of sample micro‐structures and chemistry, possibly without the need for sample extraction from some types of sampling and capture media.

Geochemistry & Geophysics↗

X-Ray Induced Chemical Reaction Revealed by In Situ X-Ray Diffraction and Scanning X-Ray Microscopy in 15 nm Resolution

The detection sensitivity of synchrotron-based X-ray techniques has been largely improved due to the ever-increasing source brightness, which has significantly advanced ex situ and in situ research for energy materials such as lithium-ion batteries. However, the strong beam–material interaction arising from the high beam flux can substantially modify the material structure. The beam-induced parasitic effect inevitably interferes with the intrinsic material property, making the interpretation of the experimental results difficult and requiring comprehensive assessments. Here, we present a quantitative study of the beam effect on an electrode material Ag 2 VO 2 PO 4 using four different X-ray characterization methods with different radiation dose rates. The material system exhibits interesting and reversible radiation-induced thermal and chemical reactions, further evaluated under electron microscopy to illustrate the underlying mechanism. Further, the work will provide a guideline for using synchrotron X-rays to distinguish the intrinsic behavior from extrinsic structure change of materials induced by X-rays.

36 MATERIALS SCIENCE↗

CPU and memory efficient coherent mode decomposition for the partially coherent x-ray simulations

In this work, the method of the Coherent Mode Decomposition (CMD) is applied to numerical wave propagation calculations for partially-coherent X-rays, using the Fourier optics and compatible methods. Its CPU and memory efficiency is discussed in various cases of the wavefront at the source and the beam waist. With the absence of the quadratic phase terms, the required sampling density of the electric fields is effectively reduced. The problem size is thus moderate and the method is feasible to be implemented on a single-node CPU server. In other cases, the same argument holds with proper treatments of the quadratic phase terms. Tests on CMD and the modes propagation are done for the case of the Coherent Hard X-ray beamline of the National Synchrotron Light Source II, using the Synchrotron Radiation Workshop software. We observe a few hundred or less dominant decomposed modes that resemble the electric fields converge to the wavefront intensity at a high accuracy of over 99%.

36 MATERIALS SCIENCE↗

Towards a new generation long trace profiler LTP-2020: optical design of pencil beam interferometry sensor

Improvements in the quality of synchrotron beamline x-ray optics required for next-generation light sources (e.g. the ALS Upgrade project) drive the need to improve the performance of the metrology instrumentation used to measure these components. The Long Trace Profiler (LTP) that is in use at many synchrotron metrology laboratories around the world has some known issues that affect the accuracy of its measurements. The main error source is optical path difference (OPD) phase error introduced into the probe beam by inhomogeneities in the glass components used in the optical head. We have developed a new optical head design, LTP-2020, that replaces the cube polarizing beamsplitter (PBS) with a thin wedge plate polarizing beamsplitter (WPBS) and replaces the cemented doublet lens with an aspheric singlet. Both of these components significantly reduce the glass volume traversed by the laser probe beam. Careful attention to ghost ray interference produced by back reflection from optical surfaces is necessary to minimize distortion in the primary image that translates into systematic error in the slope angle measurement. We make extensive use of a commercial raytracing program to model the back reflections and adjust component parameters as necessary to minimize distortion. Deliberate misalignment of components is necessary to make the system perform correctly. Stringent requirements are placed on the 45◦ incidence coatings on the WPBS and on the normal incidence coatings on the lens and camera window elements. We encourage our colleagues who wish to upgrade their current LTP systems to join us in the procurement of these custom optical components.

Takacs, Peter Z.↗

Thermal equation of state for zoisite: Implications for the transportation of water into the upper mantle and the high-velocity anomaly in the Farallon plate

Seismic tomography studies have revealed a high-velocity anomaly at depths between 100 km and 300 km in the Farallon plate. However, the reasons for the high-velocity anomaly continue to be debated. An analysis of the mineral proportions of eclogites exhumed from the Farallon plate shows that the average amount of zoisite in eclogite is ∼16.0 vol%. Therefore, the presence of zoisite eclogite needs to be considered to explain the high-velocity anomaly of the Farallon plate. However, the thermal equation of state and stability of zoisite have not been fully investigated under high pressure−temperature (P-T) conditions. We investigated the high-pressure and high-temperature behavior of natural zoisite utilizing synchrotron single crystal-X-ray diffraction (XRD). The results indicate that zoisite is metastable up to 24.8 GPa and 700 K. We obtained the ambient unit-cell volume V0 = 901.26(3) Å3 by synchrotron single crystal-XRD measurement. We also fitted the pressure-volume-temperature data to a high-temperature Birch-Murnaghan equation of state and obtained the zero-pressure bulk modulus K0 = 134.7(8) GPa, the temperature derivative of the bulk modulus (∂K/∂T)P = −0.011(4) GPa/K, and the thermal expansion coefficients α0V = 1.9(7) × 10−5 K−1 and α1V = 3(2) × 10−8 K−2 when the pressure derivative of bulk modulus (K′0) is fixed at 4. By incorporating the results from previous studies, we calculated the density and bulk sound velocity profiles of zoisite eclogite along the Farallon plate geotherm. Finally, we infer that zoisite could carry water to depths of ∼300 km within cold subducting slabs and that the bulk sound velocity of typical zoisite eclogite with ∼61.0 vol% omphacite, ∼23.0 vol% garnet, and ∼16.0 vol% zoisite could cause the high-velocity anomalies at depths of 100−300 km in the Farallon plate.

Geology↗

Lightfall v0.0.1

Lightfall is a desktop application for synchrotron beamline instrument control, data acquisition, and live analysis at the Advanced Light Source (ALS). Built on Python and Qt, it provides a native graphical interface for operating beamline hardware, configuring and executing experimental scans, and visualizing results in real time. Key features include direct integration with EPICS control systems, a built-in electronic logbook, remote beamline access over secure tunnels, and an interprocess communication (IPC) architecture that coordinates with external analysis applications via ZMQ and EPICS process variables. This IPC approach allows Lightfall to orchestrate specialized analysis tools—including GPU-accelerated streaming correlators—without embedding them, avoiding the dependency conflicts common in monolithic scientific software platforms. Compared to prior approaches such as Xi-CAM's plugin-based architecture, Lightfall's design cleanly separates instrument control from domain-specific analysis, enabling feedback-driven acquisition where live analysis results can adjust scan parameters during an experiment. Its native Qt interface provides responsive performance for real-time data visualization that web-based alternatives struggle to match. Lightfall is designed for use by beamline scientists and staff operating synchrotron instruments at national user facilities.

Pandolfi, Ronald [Lawrence Berkeley National Labor↗

Multiscale X-ray phase contrast imaging of human cartilage for investigating osteoarthritis formation

The evolution of cartilage degeneration is still not fully understood, partly due to its thinness, low radio-opacity and therefore lack of adequately resolving imaging techniques. X-ray phase-contrast imaging (X-PCI) offers increased sensitivity with respect to standard radiography and CT allowing an enhanced visibility of adjoining, low density structures with an almost histological image resolution. This study examined the feasibility of X-PCI for high-resolution (sub-) micrometer analysis of different stages in tissue degeneration of human cartilage samples and compare it to histology and transmission electron microscopy. Ten 10%-formalin preserved healthy and moderately degenerated osteochondral samples, post-mortem extracted from human knee joints, were examined using four different X-PCI tomographic set-ups using synchrotron radiation the European Synchrotron Radiation Facility (France) and the Swiss Light Source (Switzerland). Volumetric datasets were acquired with voxel sizes between 0.7 × 0.7 × 0.7 and 0.1 × 0.1 × 0.1 µm 3 . Data were reconstructed by a filtered back-projection algorithm, post-processed by ImageJ, the WEKA machine learning pixel classification tool and VGStudio max. For correlation, osteochondral samples were processed for histology and transmission electron microscopy. X-PCI provides a three-dimensional visualization of healthy and moderately degenerated cartilage samples down to a (sub-)cellular level with good correlation to histologic and transmission electron microscopy images. X-PCI is able to resolve the three layers and the architectural organization of cartilage including changes in chondrocyte cell morphology, chondrocyte subgroup distribution and (re-)organization as well as its subtle matrix structures. X-PCI captures comprehensive cartilage tissue transformation in its environment and might serve as a tissue-preserving, staining-free and volumetric virtual histology tool for examining and chronicling cartilage behavior in basic research/laboratory experiments of cartilage disease evolution.

3D analysis↗

Data processing methods and data acquisition for samples larger than the field of view in parallel-beam tomography

Parallel-beam tomography systems at synchrotron facilities have limited field of view (FOV) determined by the available beam size and detector system coverage. Scanning the full size of samples bigger than the FOV requires various data acquisition schemes such as grid scan, 360-degree scan with offset center-of-rotation (COR), helical scan, or combinations of these schemes. Though straightforward to implement, these scanning techniques have not often been used due to the lack of software and methods to process such types of data in an easy and automated fashion. The ease of use and automation is critical at synchrotron facilities where using visual inspection in data processing steps such as image stitching, COR determination, or helical data conversion is impractical due to the large size of datasets. Here, we provide methods and their implementations in a Python package, named Algotom, for not only processing such data types but also with the highest quality possible. The efficiency and ease of use of these tools can help to extend applications of parallel-beam tomography systems.

36 MATERIALS SCIENCE↗

Refractive axicon for X-ray microscopy applications: design, optimization, and experiment

In a full-field transmission X-ray microscopy (TXM) setup, a condenser X-ray optical element is used to illuminate the sample by condensing the X-ray beam delivered by the synchrotron storage ring. On-going and future upgrades of synchrotron facilities to diffraction-limited storage rings will pose new challenges to these TXM setups, such as much smaller X-ray beams on the condenser. Here, we demonstrate that a refractive axicon can be used as an X-ray beam shaper to match the ring-shaped aperture of the condenser. Aiming at more efficient use of the incoming X-ray intensity, we explore several axicon designs both analytically and with numerical simulations. The axicons were produced by two-photon polymerization 3D printing on thin silicon nitride membrane substrates. The first characterization of the axicon was carried out at the TOMCAT beamline of the Swiss Light Source (Switzerland).

47 OTHER INSTRUMENTATION↗

AutoFocus: AI/ML-driven real-time wavefront diagnostics to autonomously align and optimize X-ray optics

We present an integrated system that combines advanced wavefront diagnostics with artificial intelligence (AI) to automate and optimize X-ray optics at synchrotron beamlines. This system couples real-time wavefront sensing with AI-driven control algorithms to achieve precise beam alignment, stabilization, and performance optimization. A key feature is the use of multi-fidelity transfer learning, which enables knowledge gained from both real-world beamline optimizations and ultra-realistic digital twin simulations to be effectively applied to in situ optimization. By leveraging multi-objective bayesian optimization, the system continuously refines its performance, reducing optimization time and minimizing the need for manual adjustments. Designed for seamless deployment, it operates with existing beamline hardware and provides an intuitive graphical interface. Initial deployments at the advanced photon source beamlines have demonstrated its ability to enhance beam stability, improve reproducibility, and significantly streamline alignment procedures. This AI-enhanced control framework represents a significant step toward fully autonomous beamline operation in next-generation synchrotron facilities.

Rebuffi, Luca [Argonne National Laboratory (ANL), ↗

Incident excitation effects on ZnO-based photoluminescence

Zinc oxide (ZnO) is an attractive semiconductor material owing to a wide band gap, large exciton binding energy, and strong luminescent properties. Two distinct spectral regions are present in the room temperature emission of this material: a narrow line in the UV/near-UV region that is excitonic in nature and a lower energy broad emission band centered in the green/yellow region. Commercially available ZnO particles containing excess Zn and oxygen vacancy defect sites (referred to as ZnO:Zn) were excited using three light sources to study different radiative recombination regimes of the as-received powders. First, a UV LED at a center wavelength of 365 nm provided low irradiance (0.02–0.08 W/cm 2 ) with varying pulse widths (continuous operation to 16 ns). Second, the third harmonic of a pulsed Nd:YAG laser provided high irradiances (∼10 4 –10 6 W/cm 2 ) at a fixed nominal pulse width of 5 ns. Finally, a continuous polychromatic synchrotron X-ray source was also used to excite the ZnO:Zn powders. During UV LED excitation, a low number of carriers are created in the material, leading to an anticipated linear relationship between luminescence and irradiance. This held true for defect luminescence; however, there was an observed enhancement of exciton emission relative to the UV LED intensity as the pulse width was decreased, independent of irradiance. During UV laser excitation, the number of carriers was significantly increased, raising the material into a bimolecular recombination regime, which produced exciton emission much stronger than visible band emission. Finally, spectra obtained during synchrotron X-ray excitation, whose continuous illumination and higher penetration depth yielded higher emission from defect sites relative to exciton emission. A redshift in the exciton emission was also observed as excitation pulse width and sample temperature were varied, and is discussed.

Westphal, Eric Robert [Sandia National Lab. (SNL-N↗