Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Spring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

Fluence thresholds for grazing incidence hard x-ray mirrors

X-ray Free Electron Lasers (XFELs) have the potential to contribute to many fields of science and to enable many new avenues of research, in large part due to their orders of magnitude higher peak brilliance than existing and future synchrotrons. To best exploit this peak brilliance, these XFEL beams need to be focused to appropriate spot sizes. However, the survivability of X-ray optical components in these intense, femtosecond radiation conditions is not guaranteed. As mirror optics are routinely used at XFEL facilities, a physical understanding of the interaction between intense X-ray pulses and grazing incidence X-ray optics is desirable. We conducted single shot damage threshold fluence measurements on grazing incidence X-ray optics, with coatings of ruthenium and boron carbide, at the SPring-8 Angstrom compact free electron laser facility using 7 and 12 keV photon energies. The damage threshold dose limits were found to be orders of magnitude higher than would naively be expected. The incorporation of energy transport and dissipation via keV level energetic photoelectrons accounts for the observed damage threshold.

43 PARTICLE ACCELERATORS↗

Analysis system of submicron particle tracks in the fine-grained nuclear emulsion by a combination of hard x-ray and optical microscopy

Analyses of nuclear emulsion detectors that can detect and identify charged particles or radiation as tracks have typically utilized optical microscope systems because the targets have lengths from several μm to more than 1000 μm. For recent new nuclear emulsion detectors that can detect tracks of submicron length or less, the current readout systems are insufficient due to their poor resolution. In this study, we developed a new system and method using an optical microscope system for rough candidate selection and the hard X-ray microscope system at SPring-8 for high-precision analysis with a resolution of better than 70 nm resolution. Furthermore, we demonstrated the analysis of submicron-length tracks with a matching efficiency of more than 99% and position accuracy of better than 5 μm. This system is now running semi-automatically.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-ray Compton scattering experiments for fluid alkali metals at high temperatures and pressures

We have developed a high-pressure vessel and a cell for x-ray Compton scattering measurements of fluid alkali metals. Measurements have been successfully carried out for alkali metal rubidium at elevated temperatures and pressures using synchrotron radiation at SPring-8. The width of Compton profiles (CPs) of fluid rubidium becomes narrow with decreasing fluid density, which indicates that the CPs sensitively detect the effect of reduction in the valence electron density. At the request of all authors of the paper, and with the agreement of the Proceedings Editor, an updated version of this article was published on 10 September 2015. The original article supplied to AIP Publishing was not the final version and contained PDF conversion errors in Formulas (1) and (2). The errors have been corrected in the updated and re-published article.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Three-dimensional structure of brain tissue at submicrometer resolution

Biological objects are composed of submicrometer structures such as cells and organelles that are essential for their functions. Here, we report on three-dimensional X-ray visualization of cells and organelles at resolutions up to 100 nm by imaging microtomography (micro-CT) equipped with Fresnel zone plate optics. Human cerebral tissue, fruit fly cephalic ganglia, and Escherichia coli bacteria labeled with high atomic-number elements were embedded in epoxy resin and subjected to X-ray microtomography at the BL37XU and BL47XU beamlines of the SPring-8 synchrotron radiation facility. The obtained results indicated that soft tissue structures can be visualized with the imaging microtomography.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Development of high-resolution x-ray CT system using parallel beam geometry

For fine three-dimensional observations of large biomedical and organic material samples, we developed a high-resolution X-ray CT system. The system consists of a sample positioner, a 5-μm scintillator, microscopy lenses, and a water-cooled sCMOS detector. Parallel beam geometry was adopted to attain a field of view of a few mm square. A fine three-dimensional image of birch branch was obtained using a 9-keV X-ray at BL16XU of SPring-8 in Japan. The spatial resolution estimated from the line profile of a sectional image was about 3 μm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Non-invasive airway health measurement using synchrotron x-ray microscopy of high refractive index glass microbeads

Cystic fibrosis (CF) is caused by a gene defect that compromises the ability of the mucociliary transit (MCT) system to clear the airways of debris and pathogens. To directly characterise airway health and the effects of treatments we have developed a synchrotron X-ray microscopy method that non-invasively measures the local rate and patterns of MCT behaviour. Although the nasal airways of CF mice exhibit the CF pathophysiology, there is evidence that nasal MCT is not altered in CF mice1. The aim of this experiment was to determine if our non-invasive local airway health assessment method could identify differences in nasal MCT rate between normal and CF mice, information that is potentially lost in bulk MCT measurements. Experiments were performed on the BL20XU beamline at the SPring-8 Synchrotron in Japan. Mice were anaesthetized, a small quantity of micron-sized marker particles were delivered to the nose, and images of the nasal airways were acquired for 15 minutes. The nasal airways were treated with hypertonic saline or mannitol to increase surface hydration and MCT. Custom software was used to locate and track particles and calculate individual and bulk MCT rates. No statistically significant differences in MCT rate were found between normal and CF mouse nasal airways or between treatments. However, we hope that the improved sensitivity provided by this technique will accelerate the ability to identify useful CF lung disease-modifying interventions in small animal models, and enhance the development and efficacy of proposed new therapies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Imaging properties and its improvements of scanning/imaging x-ray microscope

A scanning / imaging X-ray microscope (SIXM) system has been developed at SPring-8. The SIXM consists of a scanning X-ray microscope with a one-dimensional (1D) X-ray focusing device and an imaging (full-field) X-ray microscope with a 1D X-ray objective. The motivation of the SIXM system is to realize a quantitative and highly-sensitive multimodal 3D X-ray tomography by taking advantages of both the scanning X-ray microscope using multi-pixel detector and the imaging X-ray microscope. Data acquisition process of a 2D image is completely different between in the horizontal direction and in the vertical direction; a 1D signal is obtained with the linear-scanning while the other dimensional signal is obtained with the imaging optics. Such condition have caused a serious problem on the imaging properties that the imaging quality in the vertical direction has been much worse than that in the horizontal direction. In this paper, two approaches to solve this problem will be presented. One is introducing a Fourier transform method for phase retrieval from one phase derivative image, and the other to develop and employ a 1D diffuser to produce an asymmetrical coherent illumination.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Upgrading multilayer zone plate technology for hard x-ray focusing

Multilayer zone plate (MZP) technology for hard X-ray focusing was upgraded and its focusing performance was evaluated using 20-keV X-rays at the synchrotron beamline (BL24XU) of SPring-8. The MZP consists of MoSi{sub 2} and Si layers alternately deposited on a glass fiber by magnetron sputtering so that all zone boundaries satisfy the Fresnel zone configuration. The focused beam was evaluated using knife-edge scanning in which the measured intensity distribution is identical to the line spread function (LSF) in the focal plane. The focused beamsize of about 30 nm was estimated by oscillation peaks observed in the measured LSF according to Rayleigh’s criterion.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of sealed sample containers and high resolution micro-tomography

A sample container and a high resolution micro-tomography system have been developed at BL47XU at SPring-8. The container is made of a SiN membrane in a shape of truncated pyramid, which makes it possible to exclude oxygen and moisture in the air. The sample rotation stage for tomography is set downward to keep the sample in the container without any glue. The spatial resolution and field of view are 300 nm and 110 μm using a Fresnel zone plate objective with an outermost zone width of 100 nm at 8 keV, respectively. The scan time is about 20 minutes for 1800 projections. A 3-D image of an asteroid particle was successfully obtained without adhesive and contamination.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Rare earth element content of cryptocrystalline magnesites of Konya, Turkey

We examined the rare earth element content of several cryptocrystalline magnesites as well as hydromagnesite, host rock serpentinites, lake water and hot spring water from Turkey. Southwestern Turkey hosts cryptocrystalline magnesites, sedimentary magnesites with presently forming, biologically mediated hydromagnesites and travertines. Our results show the REE content of the minerals, rocks and waters are well below detection limits. One hydromagnesite sample from Lake Salda has slightly high La (2.38ppb), Ce (3.91 ppb) and Nd (1.68 ppb) when compared to other samples, but these are also still below detection limits of the method we followed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

TAKASAGO-6 apparatus for cryogenic coherent X-ray diffraction imaging of biological non-crystalline particles using X-ray free electron laser at SACLA

Coherent X-ray diffraction imaging (CXDI) is a technique for structure analyses of non-crystalline particles with dimensions ranging from micrometer to sub-micrometer. We have developed a diffraction apparatus named TAKASAGO-6 for use in single-shot CXDI experiments of frozen-hydrated non-crystalline biological particles at cryogenic temperature with X-ray free electron laser pulses provided at a repetition rate of 30 Hz from the SPring-8 Angstrom Compact free-electron LAser. Specimen particles are flash-cooled after being dispersed on thin membranes supported by specially designed disks. The apparatus is equipped with a high-speed translation stage with a cryogenic pot for raster-scanning of the disks at a speed higher than 25 μm/33 ms. In addition, we use devices assisting the easy transfer of cooled specimens from liquid-nitrogen storages to the cryogenic pot. In the current experimental procedure, more than 20 000 diffraction patterns can be collected within 1 h. Here we report the key components and performance of the diffraction apparatus. Based on the efficiency of the diffraction data collection and the structure analyses of metal particles, biological cells, and cellular organelles, we discuss the future application of this diffraction apparatus for structure analyses of biological specimens.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Damage threshold of coating materials on x-ray mirror for x-ray free electron laser

We evaluated the damage threshold of coating materials such as Mo, Ru, Rh, W, and Pt on Si substrates, and that of uncoated Si substrate, for mirror optics of X-ray free electron lasers (XFELs). Focused 1 μm (full width at half maximum) XFEL pulses with the energies of 5.5 and 10 keV, generated by the SPring-8 angstrom compact free electron laser (SACLA), were irradiated under the grazing incidence condition. The damage thresholds were evaluated by in situ measurements of X-ray reflectivity degradation during irradiation by multiple pulses. The measured damage fluences below the critical angles were sufficiently high compared with the unfocused SACLA beam fluence. Rh coating was adopted for two mirror systems of SACLA. One system was a beamline transport mirror system that was partially coated with Rh for optional utilization of a pink beam in the photon energy range of more than 20 keV. The other was an improved version of the 1 μm focusing mirror system, and no damage was observed after one year of operation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Stitching methods at the European Synchrotron Radiation Facility (ESRF)

X-ray mirror quality has continuously improved over the past 20 years and manufacturers are now able to provide long mirrors with slope errors below 0.2 μrad. Nevertheless, these mirrors are mounted on holders or even mechanical benders to adjust their curvature and their intrinsic quality must be preserved from any parasitic deformation such as twist. The most direct method of detecting these deformations is to measure the 3D topography of the optical surface. At the ESRF metrology laboratory, three different stitching systems are under development based on Fizeau sub-aperture measurements. The first one consists of measuring long flat mirrors, the second based on the relative angle determinable stitching interferometry (RADSI) method developed at SPring-8 is aimed primarily at the measurement of short mirrors with strong curvature down to a few meters, and the last, also based on the RADSI method, is dedicated to characterize longer mirrors with intermediate curvature. For each method we will describe the measurement setup and discuss first results obtained. Micro-stitching interferometry is also currently used at the ESRF metrology laboratory. The technique is suitable for measuring deeply curved aspherical profiles and will be illustrated with results from a Kirkpatrick-Baez mirror system for nano-focusing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-ray microfocusing with off-axis ellipsoidal mirror

High-precision ellipsoidal mirrors for two-dimensionally focusing X-rays to nanometer sizes have not been realized because of technical problems in their fabrication processes. The objective of the present study is to develop fabrication techniques for ellipsoidal focusing mirrors in the hard-X-ray region. We design an off-axis ellipsoidal mirror for use under total reflection conditions up to the X-ray energy of 8 keV. We fabricate an ellipsoidal mirror with a surface roughness of 0.3 nm RMS (root-mean-square) and a surface figure error height of 3.0 nm RMS by utilizing a surface profiler and surface finishing method developed by us. The focusing properties of the mirror are evaluated at the BL29XUL beamline in SPring-8. A focusing beam size of 270 nm × 360 nm FWHM (full width at half maximum) at an X-ray energy of 7 keV is observed with the use of the knife-edge scanning method. We expect to apply the developed fabrication techniques to construct ellipsoidal nanofocusing mirrors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-ray beam transfer between hollow fibers for long-distance transport

Fiber optics for controlling the x-ray beam trajectory has been examined at the synchrotron facility of SPring-8. Up to now, we have achieved beam deflection by several tens of milli-radian and axis shift of around 75 mm with a 1.5 m-long flexible hollow glass capillary. The achievable beam deflecting angle, axis shift, and timing delay are, in principle, proportional to the length, the square of length and the cube of length, respectively. Thus, for further applications, requiring larger beam shift and pulse delay, longer fibers are indispensable. In order to achieve long-distance transport using the fiber, we thus examined the connection transferring x-rays between fibers in an experimental hutch. The acceptance angle at the input end and the throughput efficiency of the second fiber is consistent with the consideration of the output beam divergence of the first fiber. The enhancement of the transfer efficiency is also discussed for the cases of a closer joint and the use of a refractive lens as a coupler.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Characterization of domain structure in one-dimensional SrRuO{sub 3} nanostructure using synchrotron x-ray microdiffraction

SrRuO{sub 3} (SRO) thin films with a geometric shape of one-dimensional stripes can be epitaxially grown on a SrTiO{sub 3} (STO) substrate. Conventional X-ray reciprocal space map (RSM) measurements revealed that the stripes consist of multiple crystallographic domains. We performed synchrotron X-ray microdiffraction measurements to determine whether the single stripe of the SRO has a single crystallographic domain or not. Spacing between stripes is ~200 nm that is comparable to a beam size available for the microdiffraction. The synchrotron X-ray microdiffraction experiment was performed at BL13XU, SPring-8. RSMs of asymmetric diffractions around STO 204 reflection were measured by a broad-beam (200 × 200 µm{sup 2}) and the sub-micro-beam (250(h) × 190(v) nm{sup 2}). Both SRO 260 and 620 are seen in the RSM measured by the broad-beam due to the crystallographic twinning. On the other hand, only SRO 620 is observed in the RSM measured by the sub-micro-beam. The result shows the domain length of the single stripe SRO thin film is longer than the vertical beam size of 190 nm.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Scanning three-dimensional x-ray diffraction microscopy using a high-energy microbeam

A scanning three-dimensional X-ray diffraction (3DXRD) microscope apparatus with a high-energy microbeam was installed at the BL33XU Toyota beamline at SPring-8. The size of the 50 keV beam focused using Kirkpatrick-Baez mirrors was 1.3 μm wide and 1.6 μm high in full width at half maximum. The scanning 3DXRD method was tested for a cold-rolled carbon steel sheet sample. A three-dimensional orientation map with 37 {sup 3} voxels was obtained.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Soft mobile robots driven by foldable dielectric elastomer actuators

A cantilever beam with elastic hinge pulled antagonistically by two dielectric elastomer (DE) membranes in tension forms a foldable actuator if one DE membrane is subject to a voltage and releases part of tension. Simply placing parallel rigid bars on the prestressed DE membranes results in enhanced actuators working in a pure shear state. We report design, analysis, fabrication, and experiment of soft mobile robots that are moved by such foldable DE actuators. We describe systematic measurement of the foldable actuators and perform theoretical analysis of such actuators based on minimization of total energy, and a good agreement is achieved between model prediction and measurement. We develop two versions of prototypes of soft mobile robots driven either by two sets of DE membranes or one DE membrane and elastic springs. We demonstrate locomotion of these soft mobile robots and highlight several key design parameters that influence locomotion of the robots. A 45 g soft robot driven by a cyclic triangle voltage with amplitude 7.4 kV demonstrates maximal stroke 160 mm or maximal rolling velocity 42 mm/s. The underlying mechanics and physics of foldable DE actuators can be leveraged to develop other soft machines for various applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗