Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Spectrometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

Coupling of high-resolution mass spectrometer and photosynthesis system for comprehensive leaf volatile metabolite profiling

Background Leaf-level biogenic volatile organic compounds (BVOCs) emissions represent a major source of organic gases in the atmosphere, influencing both climate and air quality. These emissions are strongly driven by environmental perturbations, which affect individual plant- to ecosystem-level processes. Uncovering all the BVOCs and understanding how their emissions respond to altered environmental conditions provide critical insights into vegetation-driven changes in atmospheric chemistry. We developed a tandem instrumentation setup that integrates a proton transfer reaction time-of-flight mass spectrometer (PTR-ToF-MS) with parts-per-trillion detection limits and a photosynthetic infrared gas exchange system for the untargeted survey of all the BVOCs. This novel system enables simultaneous, real-time monitoring of BVOC emissions and photosynthetic parameters at the leaf level, offering new opportunities to disentangle the physiological and environmental drivers of VOC release. Furthermore, we established the VOC Analysis and Processing Optimization Resource (VAPOR), an open-access software tool designed for rapid data post-processing and the analysis of the variability of hundreds of BVOCs. We assessed the performance of the tandem system under varying background conditions, using standard gas mixtures and a range of environmental factors. Results Blank emissions were substantially lower for major BVOCs (e.g., isoprene) compared to those observed in plant emissions. Despite this, the observation of background-level VOCs highlights the importance of routinely acquiring and accounting for blank measurements in analyses using the coupled instrumentation. Introduction of known VOC concentrations to the system demonstrated a linear response across different compounds with varying molecular compositions, indicating minimal gas loss regardless of chemical moieties within the coupled instrumentation. We applied the optimized system to investigate the physiological mechanisms driving BVOC emissions across different genotypes of poplar and pennycress. The high mass resolution capabilities of the PTR-ToF-MS, coupled with comprehensive VAPOR-driven data analysis, enabled the identification of several important BVOCs, including methanol and methanethiol; these BVOCs displayed substantial variation across pennycress genotypes and showed concentrations ~ 100–350% higher than the blank. Moreover, isoprene emissions varied significantly among poplar genotypes grown in different potting media. Conclusions Tandem instrumentation offers a powerful tool for profiling volatile molecular markers and elucidating their genetic and environmental underpinnings. This approach enhances our ability to predict BVOC emissions in response to genotype by environmental interactions and contributes to a deeper understanding of vegetation responses to environmental changes.

Biogenic volatile organic compounds↗

Dataset for First Full Dalitz Plot Measurement in Neutron β-Decay using the Nab Spectrometer and Implications for New Physics

The Nab apparatus at the Fundamental Neutron Physics Beamline at the Spallation Neutron Source was designed to measure key observations in neutron beta decay, test the Standard Model's description of the weak interaction, and search for new physics. This data was collected using the Nab apparatus and are presented in the article "First Full Dalitz Plot Measurement in Neutron β-Decay using the Nab Spectrometer and Implications for New Physics." This data publication includes CSV (comma-separated values) files which are used to generate Figures 3 - 11 in the linked journal article.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

OrganiCam: a lightweight time-resolved laser-induced luminescence imager and Raman spectrometer for planetary organic material characterization

OrganiCam is a laser-induced luminescence imager and spectrometer designed for standoff organic and biosignature detection on planetary bodies. OrganiCam uses a diffused laser beam (12° cone) to cover a large area at several meters distance and records luminescence on half of its intensified detector. The diffuser can be removed to record Raman and fluorescence spectra from a small spot from 2 m standoff distance. OrganiCam’s small size and light weight makes it ideal for surveying organics on planetary surfaces. Here, we have designed and built a brassboard version of the OrganiCam instrument and performed initial tests of the system.

47 OTHER INSTRUMENTATION↗

Optical calibration of the SuperCam instrument body unit spectrometers

The SuperCam remote sensing instrument on NASA’s Perseverance rover is capable of four spectroscopic techniques, remote micro-imaging, and audio recording. These analytical techniques provide details of the chemistry and mineralogy of the rocks and soils probed in the Jezero Crater on Mars. Here we present the methods used for optical calibration of the three spectrometers covering the 243–853 nm range used by three of the four spectroscopic techniques. We derive the instrument optical response, which characterizes the instrument sensitivity to incident radiation as a function of a wavelength. The instrument optical response function derived here is an essential step in the interpretation of the spectra returned by SuperCam as it converts the observed spectra, reported by the instrument as “digital counts” from an analog to digital converter, into physical values of spectral radiance.

Legett, Carey (ORCID:0000000247412841)↗

Compact mid-infrared dual-comb spectrometer for outdoor spectroscopy

This manuscript describes the design of a robust, mid-infrared dual-comb spectrometer operating in the 3.1-µm to 4-µm spectral window for future field applications. The design represents an improvement in system size, power consumption, and robustness relative to previous work while also providing a high spectral signal-to-noise ratio. We demonstrate a system quality factor of 2×10 6 and 30 hours of continuous operation over a 120-meter outdoor air path.

Ycas, Gabriel↗

Visible (400- to 700-nm) chirped-grating-coupled waveguide spectrometer

An integrable on-chip spectrometer, based on a transversely-chirped-grating waveguide-coupler for the 400- to 700-nm visible spectral range is demonstrated. For a fixed angle of incidence, the coupling wavelength is dependent on the local grating period and the waveguide structure. The transversely-chirped-input grating is fabricated on a SiO 2 -Si 3 N 4 -SiO 2 waveguide atop a Si substrate by interferometric lithography in two sections on a single silicon substrate. A uniform period grating, separated from the input coupler by a propagation region, is provided for out-coupling to a 2048 element CMOS detector array. The incident light with wavelength spanning 400- to 700-nm is coupled into waveguide at 33.5° through the chirped grating coupler. A resolution of ∼ 1.2 nm is demonstrated without any signal processing reconstruction.

Wang, Xuemei↗

Fast data-driven spectrometer with direct measurement of time and frequency for multiple single photons

We present a single-photon-sensitive spectrometer based on a linear array of 512 single-photon avalanche diode detectors with 0.04 nm spectral and 40 ps temporal resolutions. We employ a fast data-driven operation that allows direct measurement of time and frequency for simultaneous single photons, time- and frequency-stamping each single-photon detection. Our results combine excellent temporal and spectral resolution. This work opens numerous applications in quantum photonics, especially when both spectral and temporal properties of single photons can be exploited.

79 ASTRONOMY AND ASTROPHYSICS↗

Pump–probe spectrometer for measuring x-ray induced strain

A hard x-ray pump–probe spectrometer using a multi-crystal Bragg reflector is demonstrated at a third generation synchrotron source. This device derives both broadband pump and monochromatic probe pulses directly from a single intense, broadband x-ray pulse centered at 8.767 keV. In conclusion, we present a proof-of-concept experiment which directly measures x-ray induced crystalline lattice strain.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sensitivity Limitation of an Optical Heterodyne Spectrometer

We show an optical heterodyne spectrometer with picometer resolution and high sensitivity. Moreover, we report the quantum limit of detecting multi-mode light using heterodyne detection, and compare it to a typical down conversion source output.

Chapman, Joseph↗

High-energy inelastic neutron scattering data taken at the SEQUOIA spectrometer.

INS measurements were performed using the Fine Resolution Chopper Spectrometer SEQUOIA at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory. A powder sample of SrCoGe2O6 was loaded in an aluminum can for the measurements and a CCR was used to cool the sample down to 6 K. Data were collected using fixed incident neutron energies of 100 and 30 meV.

MATERIALS SCIENCE↗

Low energy inelastic neutron scattering (INS) data of SrCoGe2O6 taken at CNCS chopper spectrometer.

INS measurements were performed using the Cold Neutron Chopper Spectrometer CNCS at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory. A powder sample of SrCoGe2O6 was loaded in an aluminum can for the measurements and a standard orange cryostat was used to cover the temperature region from 1.7 K to 100 K. Data were collected using fixed incident neutron energy of 5.0 meV.

MATERIALS SCIENCE↗

INS spectra of NH3 and ND3 obtained at SEQUOIA spectrometer

These INS data were measured at SEQUOIA spectrometer. The samples used were NH3 and ND3, and empty container (background runs). The measurements were done with incident neutron energies Ei=30, 50, 85, 280 and 700 meV at T=5K, 50K, 100K, 180K, 200K for NH3 sample, and with Ei=30, 70, 200, 500 meV at T=5K, 50K, 100K, 180K, 200K and 230K for ND3.

excitations↗

Measurement of differential cross sections for single diffractive dissociation in s = 8 TeV p p collisions using the ATLAS ALFA spectrometer

A dedicated sample of Large Hadron Collider proton-proton collision data at centre-of-mass energy s√=8 TeV is used to study inclusive single diffractive dissociation, pp→Xp. The intact final-state proton is reconstructed in the ATLAS ALFA forward spectrometer, while charged particles from the dissociated system X are measured in the central detector components. Cross sections are measured differentially as functions of the proton fractional energy loss ξ, the squared four-momentum transfer t, and Δη, a variable that characterises the rapidity gap separating the proton and the system X. The data are consistent with an exponential t dependence, dσ/dt∝eBt with slope parameter B=7.65±0.34 GeV−2. Interpreted in the framework of Regge phenomenology, the ξ dependence leads to a pomeron intercept of α(0)=1.07±0.09.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

MPACT LSDS Progress Report: LANL and LANL-Funded Activities in Support of Spent Fuel Measurements Using a Lead Slowing Down Spectrometer in FY 2012

During FY 2012, Lead Slowing Down Spectrometer (LSDS) measurement campaigns took place at the Los Alamos Neutron Science Center, and the Rensselaer Polytechnic Institute. At Los Alamos, we measured the response of a thorium fission chamber to a 25 gram plutonium sample, and evaluated the performance of a 4 He-filled proportional counter. At RPI, the effort lead by Professor Danon, performed an assay of fuel pins, and used a fission chamber with plutonium to evaluate the impact of room return.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The Effectiveness of the Compton Radiography Snout Electron Deflection Yoke and its Application as an Electron Spectrometer

The Compton Radiography Snout (CRS) is a prototype of a diagnostic called the High Energy X Ray Imager (HEXRI) that will be used to record radiographs of imploding fuel cells on NIF. With these radiographs, it is possible to characterize the density and symmetry of the imploding fuel capsule. When the advanced radiography capability is used to generate the high energy x‐rays used to backlight the radiographs, hot electrons are also produced. In order to record a clear radiograph, these electrons are deflected away from the imaging plane of the CRS using a permanent magnetic yoke. In an effort to increase the number of parameters that can be used during the scaling of the CRS for NIF, an investigation is underway to add an electron spectrometer capability to the CRS to measure the electron spectrum produced during the ARC backlighting.

42 ENGINEERING↗

Associated Particle Tagging (APT) in Magnetic Spectrometers

Summary In Brief The Associated Particle Tagging (APT) project, a collaboration of Pacific Northwest National Laboratory (PNNL), Idaho National Laboratory (INL) and the Idaho State University (ISU)/Idaho Accelerator Center (IAC), has completed an exploratory study to assess the role of magnetic spectrometers as the linchpin technology in next-generation tagged-neutron and tagged-photon active interrogation (AI).

Jordan, David V.↗

Layout and results from the initial operation of the high-resolution x-ray imaging crystal spectrometer on the Large Helical Device

First results of ion and electron temperature profile measurements from the x-ray imaging crystal spectrometer (XICS) diagnostic on the Large Helical Device (LHD) are presented. This diagnostic system has been operational since the beginning of the 2011 LHD experimental campaign and is the first application of the XICS diagnostic technique to helical plasma geometry. The XICS diagnostic provides measurements of ion and electron temperature profiles in LHD with a spatial resolution of 2cm and a time resolution of ≥ 10ms. Ion temperature profiles from the XICS diagnostic are possible under conditions where charge exchange recombination spectroscopy (CXRS) is not possible (high density) or is perturbative to the plasma (low density or radio frequency heated plasmas). Measurements are made by using a spherically bent crystal to provide a spectrally resolved 1D image of the plasma from line integrated emission of helium-like Ar 16+ . The final hardware design and configuration are detailed along with the calibration procedures. Line-integrated ion and electron temperature measurements are presented, and the measurement accuracy is discussed. Finally central temperature measurements from the XICS system are compared to measurements from the Thomson scattering and CXRS systems, showing excellent agreement.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Mobile Ice Nucleus Spectrometer

This first year report presents results from a computational fluid dynamics (CFD) study to assess the flow and temperature profiles within the mobile ice nucleus spectrometer.

Kulkarni, Gourihar R.↗