Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Signal processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

Advanced readout methods for superheated emulsion detectors

Superheated emulsions develop visible vapor bubbles when exposed to ionizing radiation. They consist in droplets of a metastable liquid, emulsified in an inert matrix. The formation of a bubble cavity is accompanied by sound waves. Evaporated bubbles also exhibit a lower refractive index, compared to the inert gel matrix. These two physical phenomena have been exploited to count the number of evaporated bubbles and thus measure the interacting radiation flux. Systems based on piezoelectric transducers have been traditionally used to acquire the acoustic (pressure) signals generated by bubble evaporation. Such systems can operate at ambient noise levels exceeding 100 dB; however, they are affected by a significant dead time (>10 ms). An optical readout technique relying on the scattering of light by neutron-induced bubbles has been recently improved in order to minimize measurement dead time and ambient noise sensitivity. Beams of infra-red light from light-emitting diode (LED) sources cross the active area of the detector and are deflected by evaporated bubbles. The scattered light correlates with bubble density. Planar photodiodes are affixed along the detector length in optimized positions, allowing the detection of scattered light from the bubbles and minimizing the detection of direct light from the LEDs. A low-noise signal-conditioning stage has been designed and realized to amplify the current induced in the photodiodes by scattered light and to subtract the background signal due to intrinsic scattering within the detector matrix. The proposed amplification architecture maximizes the measurement signal-to-noise ratio, yielding a readout uncertainty of 6% (±1 SD), with 1000 evaporated bubbles in a detector active volume of 150 ml (6 cm detector diameter). In this work, we prove that the intensity of scattered light also relates to the bubble size, which can be controlled by applying an external pressure to the detector emulsion. This effect can be exploited during the readout procedure to minimize shadowing effects between bubbles, which become severe when the latter are several thousands. The detector we used in this work is based on superheated C-318 (octafluorocyclobutane), emulsified in 100 μm ± 10% (1 SD) diameter drops in an inert matrix of approximately 150 ml. The detector was operated at room temperature and ambient pressure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Estimating the performance of lithium beam measurements of current density and electron density in an H-mode pedestal

The lithium beam is an effective diagnostic tool for investigation of stability and particle transport in the pedestal. It was used successfully to measure edge current density on DIII-D, achieving qualitative agreement with neoclassical models. Electron density profiles were also measured. Proposed upgrades will continue these measurements with higher reliability as well as explore edge current measurements using spectroscopy. The optics will be redesigned to optimize throughput and aperture broadening and to replace the photomultiplier tubes with avalanche photodiodes. Here, the new system will yield detailed measurements of the pedestal, complementing existing diagnostics for investigating pedestal stability, edge localized mode cycle, and particle transport through the pedestal.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A combined phase contrast imaging and heterodyne interferometer system for multiscale fluctuation measurements (invited)

In this work, a novel combined diagnostic capable of measuring multiscale density fluctuations that extend from magnetohydrodynamic (MHD) to the lower range of electron temperature gradient turbulence has been designed, installed, and operated at DIII-D. The combined diagnostic was constructed by adding a heterodyne interferometer to the pre-existing phase contrast imaging (PCI) system, both of which measure line-integrated electron density fluctuations. The port-space footprint is minimized via use of a single 10.6 μm probe beam. With temporal bandwidths in excess of 1 MHz, the PCI measures high-k (1.5 cm -1 < |k R | ≤ 25 cm -1 ) fluctuations with sensitivity 3×10 13 m -2 /$\sqrt{kHz}$, while the interferometer simultaneously measures low-k (|k R | < 5 cm -1 ) fluctuations with sensitivity 3×10 14 m -2 /$\sqrt{kHz}$. The intentional mid-k overlap has been empirically verified with sound-wave calibrations and allows quantitative investigation of multiscale effects that are predicted to be significant in the reactor-relevant T e ~ T i regime. Lastly, via correlation with the primary DIII-D interferometer, the toroidal mode numbers of core-localized MHD can be measured.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Implementation of a Wollaston interferometry diagnostic on OMEGA EP

Here, a Wollaston interferometer is presented for use in measuring the electron density of plasma plumes created in experiments on the OMEGA EP laser system. The diagnostic is installed as an additional arm on the 4ω probe system, a suite of diagnostics that share a 10 ps pulse of 263 nm laser light captured by an imaging system at f /4. The interferometer utilizes a Wollaston prism to create two angularly separated beams from a single input probe beam, split at any angle between 0° and 90°. This configuration is implemented uniquely such that fringe spacing may be altered independently of field of view, magnification, and imaging resolution, from a range of 17 to 76 μm/fringe. The region of overlap between the two beams forms a total field of view of approximately 1.2 × 1.6 mm at the target chamber center with an imaging resolution of 5 μm. Using this configuration, here it is shown that plasma density may be accurately characterized over a range of 3 × 10 18 –1 × 10 20 cm -3 .

47 OTHER INSTRUMENTATION↗

Probing the predissociated levels of the S 1 state of acetylene via H-atom fluorescence and photofragment fluorescence action spectroscopy

Here, we report two new experimental schemes to obtain rotationally resolved high-resolution spectra of predissociated S 1 acetylene levels in the 47 000-47 300 cm -1 energy region (~1200 cm -1 above the predissociation threshold). The two new detection schemes are compared to several other detection schemes (employed at similar laser power, molecular beam temperature, and number of signal averages) that have been used in our laboratory to study predissociated S 1 acetylene levels, both in terms of the signal-to-noise ratio (S/N) of the resultant spectra and experimental simplicity. In the first method, H-atoms from the predissociated S 1 acetylene levels are probed by two-photon laser-induced fluorescence (LIF). The H-atoms are pumped to the 3d level by the two-photon resonance transition at 205.14 nm. The resulting 3d–2p fluorescence (654.5 nm) is collected by a photomultiplier. The S/N of the H-atom fluorescence action spectrum is consistently better by ~3× than that of the more widely used H-atom resonance-enhanced multiphoton ionization (REMPI) detection. Laser alignment is also considerably easier in H-atom fluorescence detection than H-atom REMPI detection due to the larger number-density of molecules that can be used in fluorescence vs. REMPI detection schemes. In the second method, fluorescence from electronically excited C 2 and C 2 H photofragments of S 1 acetylene is detected. In contrast to the H-atom detection schemes, the detected C 2 and C 2 H photofragments are produced by the same UV laser as is used for the ÖX acetylene excitation. As a result, laser alignment is greatly simplified for the photofragment fluorescence detection scheme, compared to both H-atom detection schemes. Using the photofragment fluorescence detection method, we are able to obtain action spectra of predissociated S 1 acetylene levels with S/N ~2× better than the HCCH REMPI detection and ~10× better than H-atom and HCCH LIF detection schemes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A broadband fiber-optic nonlinear interferometer

In this paper, we describe an all-fiber nonlinear interferometer based on four-wave mixing in highly nonlinear fiber. Our configuration realizes phase-sensitive interference with 97% peak visibility and >90% visibility over a broad 554 GHz optical band. By comparing the output noise power to the shot-noise level, we confirm noise cancellation at dark interference fringes, as required for quantum-enhanced sensitivity. Finally, our device extends nonlinear interferometry to the important platform of highly nonlinear optical fiber and could find applications in a variety of fiber-based sensors.

47 OTHER INSTRUMENTATION↗

miniTimeCube as a neutron scatter camera

We present Monte Carlo (MC) simulation results from a study of a compact plastic-scintillator detector suitable for imaging fast neutrons in the 1 – 10 MeV energy range: the miniTimeCube (mTC). Originally designed for antineutrino detection, the mTC consists of 24 MultiChannel Plate (MCP) photodetectors surrounding a 13 cm cube of boron-doped plastic scintillator. Our simulation results show that waveform digitization of 1536 optically sensitive channels surrounding the scintillator should allow for spatiotemporal determination of individual neutron-proton scatters in the detector volume to ~ 100 picoseconds and ~5 mm. A Bayesian estimation framework is presented for multiple-scatter reconstruction, and is used to estimate the incoming direction and energy of simulated individual neutrons. Finally, we show how populations of reconstructed neutrons can be used to estimate the direction and energy spectrum of nearby simulated neutron sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Lead geometry and transport statistics in molecular junctions

We present a numerically exact study of charge transport and its fluctuations through a molecular junction driven out of equilibrium by a bias voltage, using the inchworm quantum Monte Carlo method. After showing how the technique can be used to address any lead geometry, we concentrate on one dimensional chains as an example. The finite bandwidth of the leads is shown to affect transport properties in ways that cannot be fully captured by quantum master equations: in particular, we reveal an interaction-induced broadening of transport channels that is visible at all voltages and show how fluctuations of the current are a more sensitive probe of this effect than the mean current.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Propagating molecular rotational coherences through single-frequency pulses in the strong field regime

In the weak-field limit in which microwave spectroscopy is typically carried out, an application of a single-frequency pulse that is resonant with a molecular transition will create a coherence between the pair of states involved in the rotational transition, producing a free-induction decay (FID) that, after Fourier transform, produces a molecular signal at that same resonance frequency. With the advent of chirped-pulse Fourier transform microwave methods, the high-powered amplifiers needed to produce broadband microwave spectra also open up other experiments that probe the molecular response in the high-field regime. This paper describes a series of experiments involving resonant frequency pulses interrogating jet-cooled molecules under conditions of sufficient power to Rabi oscillate the two-state system through many Rabi cycles. The Fourier-transformed FID shows coherent signal not only at the applied resonant frequency but also at a series of transitions initially connected to the original one by sharing an upper or lower level with it. As the duration of the single-frequency excitation is increased from 250 to 1500 ns, the number of observed off-resonant, but dipole-allowed, molecular coherences grow. The phenomenon is quite general, having been demonstrated in Z-phenylvinylnitrile, E-phenylvinylnitrile (E-PVN), benzonitrile, guaiacol, and 4-pentynenitrile. In E-PVN, the highest power/longest pulse duration, coherent signal is also present at energetically nearby but not directly connected transitions. Even in molecular samples containing more than one independent species, only transitions due to the single species responsible for the original resonant transition are present. Here, we develop a time-dependent model of the molecular/photon system and use it in conjunction with the experiment to test possible sources of the phenomenon.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Super-resolution energy spectra from neutron direct-geometry spectrometers

Neutron direct-geometry time-of-flight chopper spectroscopy is instrumental in studying fundamental excitations of vibrational and/or magnetic origin. We report here that techniques in super-resolution optical imagery (which is in real-space) can be adapted to enhance resolution and reduce noise for a neutron spectroscopy (an instrument for mapping excitations in reciprocal space). The procedure to reconstruct super-resolution energy spectra of phonon density of states relies on a realization of multiframe registration, accurate determination of the energy-dependent point spread function, asymmetric nature of instrument resolution broadening, and iterative reconstructions. Applying these methods to phonon density of states data for a graphite sample demonstrates contrast enhancement, noise reduction, and ~5-fold improvement over nominal energy resolution. The data were collected at three different incident energies measured at the wide angular-range chopper spectrometer at the Spallation Neutron Source.

47 OTHER INSTRUMENTATION↗

Synchrotron characterization of high-Z, current-mode x-ray detectors

Fast x-ray detectors are critical tools in pulsed power and fusion applications, where detector impulse response of a nanosecond or better is often required. Semiconductor detectors can create fast, sensitive devices with extensive operational flexibility. There is typically a trade-off between detector sensitivity and speed, but higher atomic number absorbers can increase hard x-ray absorption without increasing the charge collection time, provided carriers achieve high velocity. This paper presents x-ray pulse characterization conducted at the Advanced Photon Source of x-ray absorption efficiency and temporal impulse response of current-mode semiconductor x-ray detectors composed of Si, GaAs, and CdTe.

47 OTHER INSTRUMENTATION↗

Photonic Doppler velocimetry of ohmically exploded aluminum surfaces

Photonic Doppler Velocimetry (PDV) was used to measure the exploding surface of coated metal driven by lineal current density increasing at 3 × 10 15 A/m/s. Here, aluminum-6061 rods were coated with three thicknesses (5, 17, and 41 μm) of Parylene-N and driven to 850 kA in approximately 100 ns, with the metal thicker than the skin depth. According to PDV, the metal surface melts at 85 ± 13 T and expands with a constant acceleration. Then, at surface magnetic field 140-180 T, the metal acceleration begins to increase in time. Later, plasma forms on, and is correlated with PDV signal loss from, uncoated aluminum rods, 5-μm-coated rods, and 17-μm-coated rods, while no evidence suggests plasma forms on 41-μm-coated metal.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Resolving ECRH deposition broadening due to edge turbulence in DIII-D

Microwave heat pulse propagation experiments have demonstrated a correlation between millimeter-scale turbulence and deposition profile broadening of electron cyclotron (EC) waves on the DIII-D tokamak. In a set of discharges in DIII-D, a variation in edge density fluctuations on the mm-scale is associated with 40%–150% broader deposition profiles, expressed in terms of normalized minor radius, as compared with equilibrium ray tracing. The 1D power profile is determined from transport analysis of the electron temperature response to EC power modulation using perturbative analysis with a square wave power modulation at 20–70 Hz, producing a series of Fourier harmonics that are fit collectively to resolve transport. Fitting an integrated heat flux expressed in the Fourier basis of the modulation to diffusive, convective, and coupled transport terms in a linear model can resolve the broadened EC deposition width from the power perturbation to resolve a broadening in each case. The best fit degree of beam broadening observed scales approximately linearly with the Doppler backscattering measured fluctuation level in the steep gradient region. Quantifying the effect of edge fluctuation broadening on EC current drive power needs of future devices will require 3D full-wave codes that can be validated on the current generation of machines. These DIII-D experiments provide a quantitative measure of fluctuation effects and a dataset to benchmark full-wave simulations that can model and eventually predict nonlinear effects neglected by 1D equilibrium beam and ray tracing.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Compact single-shot electro-optic detection system for THz pulses with femtosecond time resolution at MHz repetition rates

Electro-optical detection has proven to be a valuable technique to study temporal profiles of THz pulses with pulse durations down to femtoseconds. As the Coulomb field around a relativistic electron bunch resembles the current profile, electro-optical detection can be exploited for non-invasive bunch length measurements at accelerators. We have developed a very compact and robust electro-optical detection system based on spectral decoding for single-shot longitudinal bunch profile monitoring at the European X-ray Free Electron Laser (XFEL) for electron bunch lengths down to 200 fs (rms). Apart from the GaP crystal and the corresponding laser optics at the electron beamline, all components are housed in 19 in. chassis for rack mount and remote operation inside the accelerator tunnel. An advanced laser synchronization scheme based on radio-frequency down-conversion has been developed for locking a custom-made Yb-fiber laser to the radio-frequency of the European XFEL accelerator. In order to cope with the high bunch repetition rate of the superconducting accelerator, a novel linear array detector has been employed for spectral measurements of the Yb-fiber laser pulses at frame rates of up to 2.26 MHz. In this paper, we describe all sub-systems of the electro-optical detection system as well as the measurement procedure in detail and discuss the first measurement results of longitudinal bunch profiles of around 400 fs (rms) with an arrival-time jitter of 35 fs (rms).

47 OTHER INSTRUMENTATION↗

Low-pass spectral analysis of time-resolved serial femtosecond crystallography data

Low-pass spectral analysis (LPSA) is a recently developed dynamics retrieval algorithm showing excellent retrieval properties when applied to model data affected by extreme incompleteness and stochastic weighting. In this work, we apply LPSA to an experimental time-resolved serial femtosecond crystallography (TR-SFX) dataset from the membrane protein bacteriorhodopsin (bR) and analyze its parametric sensitivity. While most dynamical modes are contaminated by nonphysical high-frequency features, we identify two dominant modes, which are little affected by spurious frequencies. The dynamics retrieved using these modes shows an isomerization signal compatible with previous findings. We employ synthetic data with increasing timing uncertainty, increasing incompleteness level, pixel-dependent incompleteness, and photon counting errors to investigate the root cause of the high-frequency contamination of our TR-SFX modes. By testing a range of methods, we show that timing errors comparable to the dynamical periods to be retrieved produce a smearing of dynamical features, hampering dynamics retrieval, but with no introduction of spurious components in the solution, when convergence criteria are met. Using model data, we are able to attribute the high-frequency contamination of low-order dynamical modes to the high levels of noise present in the data. Finally, we propose a method to handle missing observations that produces a substantial dynamics retrieval improvement from synthetic data with a significant static component. Reprocessing of the bR TR-SFX data using the improved method yields dynamical movies with strong isomerization signals compatible with previous findings.

59 BASIC BIOLOGICAL SCIENCES↗

Extreme measurements with Photonic Doppler Velocimetry (PDV)

Photonic Doppler Velocimetry (PDV) is a fiber-based diagnostic for the extreme conditions created by high-speed impact, explosive detonation, electrical pulsed power, and intense laser ablation. PDV is a conceptually simple application of the optical Doppler effect, but measurements above 1 km/s only became practical at the beginning of the twenty-first century. In this work, I discuss the evolution of PDV, its operational details, practical analysis, and outstanding challenges.

47 OTHER INSTRUMENTATION↗

Phase-space dynamics of Alfvén mode chirping

In tokamak discharges, toroidal Alfvén eigenmodes often experience complex semi-periodic frequency modulation known as chirping. These events modify the local high energy particle distribution and are expected to occur in many future fusion devices, which include energetic beams or fusion products. In this paper, we present a study of simulations of mode chirping made in order to better understand its phase-space properties in a realistic tokamak configuration. We find a mechanism that permits rapid repeated chirping with strong amplitude variation in each chirp. Each chirp is then associated with an amplitude crash to low magnitude and local manipulation of the density gradients through a shift of mode phase through π. The chirping produces high density clumps, which propagate down the fast ion density gradient and low density holes that propagate up the density gradient away from the resonance. This flow of particles across the resonance provides an energy source and local gradients for repeated chirping.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Excited state dynamics of cis , cis -1,3-cyclooctadiene: UV pump VUV probe time-resolved photoelectron spectroscopy

We present UV pump, vacuum ultraviolet probe time-resolved photoelectron spectroscopy measurements of the excited state dynamics of cis,cis-1,3-cyclooctadiene. A 4.75 eV deep UV pump pulse launches a vibrational wave packet on the first electronically excited state, and the ensuing dynamics are probed via ionization using a 7.92 eV probe pulse. The experimental results indicate that the wave packet undergoes rapid internal conversion to the ground state in under 100 fs. Comparing the measurements with electronic structure and trajectory surface hopping calculations, we are able to interpret the features in the measured photoelectron spectra in terms of ionization to several states of the molecular cation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗