Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Sample”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

Calorimeters for Precision Power Dissipation Measurements on Controlled-Temperature Superconducting Radiofrequency Samples

Two calorimeters, with stainless steel and Cu as the thermal path material for high precision and high power versions, respectively, have been designed and commissioned for the surface impedance characterization (SIC) system at Jefferson Lab to provide low temperature control and measurement for CW power up to 22 W on a 5 cm dia. disk sample which is thermally isolated from the RF portion of the system. A power compensation method has been developed to measure the RF induced power on the sample. Simulation and experimental results show that with these two calorimeters, the whole thermal range of interest for superconducting radiofrequency (SRF) materials has been covered. The power measurement error in the interested power range is within 1.2% and 2.7% for the high precision and high power versions, respectively. Temperature distributions on the sample surface for both versions have been simulated and the accuracy of sample temperature measurements have been analysed. Both versions have the ability to accept bulk superconductors and thin film superconducting samples with a variety of substrate materials such as Al, Al{sub 2}O{sub 3}, Cu, MgO, Nb and Si.

43 PARTICLE ACCELERATORS↗

Automated laboratory based X-ray beamline with multi-capillary sample chamber

An automated laboratory based X-ray beamline with a multi-capillary sample chamber capable of undertaking small angle X-ray scattering measurements on a maximum of 104 samples at a time as a function of temperature between 5 and 85 °C has been developed. The modular format of the system enables the user to simultaneously equilibrate samples at eight different temperatures with an accuracy of ±0.005 °C. This system couples a rotating anode generator and 2D optoelectronic detector with Franks X-ray optics, leading to typical exposure times of less than 5 min for lyotropic liquid crystalline samples. Beamline control including sample exchange and data acquisition has been fully automated via a custom designed LabVIEW framework.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Compact ultrahigh vacuum sample environments for x-ray nanobeam diffraction and imaging

X-ray nanobeams present the opportunity to obtain structural insight in materials with small volumes or nanoscale heterogeneity. The effective spatial resolution of the information derived from nanobeam techniques depends on the stability and precision with which the relative position of the x-ray optics and sample can be controlled. Nanobeam techniques include diffraction, imaging, and coherent scattering, with applications throughout materials science and condensed matter physics. Sample positioning is a significant mechanical challenge for x-ray instrumentation providing vacuum or controlled gas environments at elevated temperatures. Such environments often have masses that are too large for nanopositioners capable of the required positional accuracy of the order of a small fraction of the x-ray spot size. Similarly, the need to place x-ray optics as close as 1 cm to the sample places a constraint on the overall size of the sample environment. We illustrate a solution to the mechanical challenge in which compact ion-pumped ultrahigh vacuum chambers with masses of 1–2 kg are integrated with nanopositioners. The overall size of the environment is sufficiently small to allow their use with zone-plate focusing optics. We describe the design of sample environments for elevated-temperature nanobeam diffraction experiments demonstrate in situ diffraction, reflectivity, and scanning nanobeam imaging of the ripening of Au crystallites on Si substrates.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: A fast pneumatic sample-shuttle with attenuated shocks

We describe a home-built pneumatic shuttle suitable for the fast displacement of samples in the vicinity of a highly sensitive atomic magnetometer. The samples are magnetized at 1 T using a Halbach assembly of magnets. The device enables the remote detection of free-induction-decay in ultra-low-field and zero-field nuclear magnetic resonance (NMR) experiments, in relaxometric measurements and in other applications involving the displacement of magnetized samples within time intervals as short as a few tens of milliseconds. Other possible applications of fast sample shuttling exist in radiological studies, where samples have to be irradiated and then analyzed in a cold environment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An experimental setup for the simultaneous measurement of thermoelectric power of two samples from 77 K to 500 K

We report on an experimental setup for the simultaneous measurement of the thermoelectric power (TEP) of two samples in the temperature range from 77 K to 500 K using optimum electronic instruments. The setup consists of two rectangular copper bars in a bridge arrangement for sample mounting, two surface mount (SM) chip resistors for creating alternate temperature gradient, and a type E thermocouple in differential geometry for gradient temperature (ΔT) measurement across the samples. In addition, a diode arrangement has been made for the alternate heating of SM resistors using only one DC current source. The measurement accuracy of ΔT increases with the differential thermocouple arrangement. For the calibration of the setup, measurements of TEP on a high purity (99.99%) platinum wire and type K thermocouple wires Chromel and Alumel have been performed from 77 K to 500 K with respect to copper lead wires. Additionally, this setup can be utilized to calibrate an unknown sample against a sample of known absolute TEP.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Reexamination of Basal Plane Thermal Conductivity of Suspended Graphene Samples Measured by Electro-Thermal Micro-Bridge Methods

Thermal transport in suspended graphene samples has been measured in prior works and this work with the use of a suspended electro-thermal micro-bridge method. These measurement results are analyzed here to evaluate and eliminate the errors caused by the extrinsic thermal contact resistance. It is noted that the thermal resistance measured in a recent work increases linearly with the suspended length of the single-layer graphene samples synthesized by chemical vapor deposition (CVD), and that such a feature does not reveal the failure of Fourier s law despite the increase in the apparent thermal conductivity with length. The re-analyzed thermal conductivity of a single-layer CVD graphene sample reaches about ( 1680 180 )Wm-1K-1 at room temperature, which is close to the highest value reported for highly oriented pyrolytic graphite. In comparison, the thermal conductivity values measured for two suspended exfoliated bi-layer graphene samples are about ( 880 60 ) and ( 730 60 ) Wm-1K-1 at room temperature, and approach that of the natural graphite source above room temperature. However, the low-temperature thermal conductivities of these suspended graphene samples are still considerably lower than the graphite values, with the peak thermal conductivities shifted to much higher temperatures. Analysis of the thermal conductivity data reveals that the low temperature behavior is dominated by phonon scattering by polymer residue instead of by the lateral boundary.

36 MATERIALS SCIENCE↗

Implementing an Accurate and Rapid Sparse Sampling Approach for Low-Dose Atomic Resolution STEM Imaging

Aberration correction for scanning transmission electron microscopes (STEM) has dramatically increased spatial image resolution for beam-stable materials, but it is the sample stability rather than the microscope that often limits the practical resolution of STEM images. To extract physical information from images of beam sensitive materials it is becoming clear that there is a critical dose/dose-rate below which the images can be interpreted as representative of the pristine material, while above it the observation is dominated by beam effects. Here we describe an experimental approach for sparse sampling in the STEM and in-painting image reconstruction in order to reduce the electron dose/dose-rate to the sample during imaging. By characterizing the induction limited rise-time and hysteresis in scan coils, we show that sparse line-hopping approach to scan randomization can be implemented that optimizes both the speed of the scan and the amount of the sample that needs to be illuminated by the beam. The dose and acquisition time for the sparse sampling is shown to be effectively decreased by factor of 5x relative to conventional acquisition, permitting imaging of beam sensitive materials to be obtained without changing the microscope operating parameters. As a result, the use of sparse line-hopping scan to acquire STEM images is demonstrated with atomic resolution aberration corrected Z-contrast images of CaCO 3 , a material that is traditionally difficult to image by TEM/STEM because of dose issues.

36 MATERIALS SCIENCE↗

Design of a containment apparatus for synchrotron XAS measurements of radioactive fluid samples under high temperatures and pressures

The simple working principles and versatility of the hydrothermal diamond-anvil cell (HDAC) make it signifcantly useful for synchrotron x-ray studies of aqueous and fluid samples at high pressure-temperature (P-T) conditions. Yet, safety concerns need to be overcome in order to use the HDAC for synchrotron studies of aqueous radioactive samples at high temperatures and pressures. For accomplishment of such hydrothermal experiments of radioactive materials at synchrotron beamlines, the samples are required to be enclosed in a containment system employing three independent layers of airtight sealing at some synchrotron facilities while enabling access to the sample using several experimental probes, including incoming and outgoing x-rays. In this article, we report the design and implementation of a complete radiological safety enclosure system for an HDAC specialized for high P-T x-ray absorption spectroscopy (XAS) measurements of aqueous solutions containing the actinides at synchrotron beamlines. The enclosure system was successfully tested for XAS experiments using the HDAC with aqueous samples containing depleted uranium at temperatures ranging from 25 to 500 °C and pressures ranging from vapor pressure to 350 MPa.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design improvements for a recirculating reactor: Enhanced temperature measurement and sample-isolated reactivity in steady-state kinetic studies

Building upon a previous recirculating reactor design [S.A. Tenney, K. Xie, J.R. Monnier, A. Rodriguez, R.P. Galhenage, S. Audrey, D.A. Chen, Rev. Sci. Instrum. 84, 104101 (2013)], we present significant improvements that address key limitations in steady-state kinetic measurements for heterogeneous catalysis. The enhanced reactor design features direct sample heating with a focused IR lamp and temperature measurement in direct contact with the sample, enabling more accurate temperature control and improved kinetic analysis. A critical advancement is the isolation of sample reactivity from reactor wall contributions, ensuring that only the sample contributes to measured reaction rates. This was a limitation in earlier designs where the entire reactor contributed to the observed reactivity. The system incorporates a bypass flow cell for direct comparison with powder catalysts under identical conditions using a standard plug-flow reactor configuration. We demonstrate these capabilities through CO oxidation experiments on Pt(111) single crystals and graphene-passivated Pt(111), highlighting the system's ability to differentiate catalytic activity in model systems and directly compare them with high surface area powder catalysts. This reactor is particularly suited for thin films and low surface area catalysts that are not effectively evaluated in traditional flow reactors, especially for samples with low numbers of active sites or slow reaction rates.

36 MATERIALS SCIENCE↗

Selection of Sampling and Surrogate Modeling Methods for State-Point Evaluations of an AGN-201M Reactor

Nuclear reactor digital twins (DTs) have been proposed for use as a safeguards technology to efficiently monitor new and novel reactors as they come online. A safeguards DT needs to be capable of detecting misuse and diversion as they occur, requiring physics models to be accurate and efficient. Mathematical surrogate models are capable of achieving the necessary efficiency and can largely maintain the accuracy of higher-order models given a quality training sample. The Multiphysics Object-Oriented Simulation Environment (MOOSE) code framework is specifically equipped to generate training samples and create surrogate models using full-order reactor physics models. Utilizing an operational AGN-201M reactor’s specifications, two surrogate types were trained on samples of variable size, and using Cartesian products, Latin hypercube sampling, and quadrature sampling, each was compared and evaluated on accuracy when compared to a full-order Monte Carlo model. Both surrogate types were able to capture reactivity changes within 0.05 $ of the Monte Carlo model while reducing the computation costs by eight orders of magnitude.

MOOSE↗

A MULTIWAVELENGTH STUDY OF A SAMPLE OF 70 mum SELECTED GALAXIES IN THE COSMOS FIELD. I. SPECTRAL ENERGY DISTRIBUTIONS AND LUMINOSITIES

We present a large robust sample of 1503 reliable and unconfused 70 mum selected sources from the multiwavelength data set of the Cosmic Evolution Survey. Using the Spitzer IRAC and MIPS photometry, we estimate the total infrared (IR) luminosity, L{sub IR} (8-1000 mum), by finding the best-fit template from several different template libraries. The long-wavelength 70 and 160 mum data allow us to obtain a reliable estimate of L{sub IR}, accurate to within 0.2 and 0.05 dex, respectively. The 70 mum data point enables a significant improvement over the luminosity estimates possible with only a 24 mum detection. The full sample spans a wide range in IR luminosity, L{sub IR} approx 10{sup 8}-10{sup 14} L{sub sun}, with a median luminosity of 10{sup 11.4} L{sub sun}. We identify a total of 687 luminous, 303 ultraluminous, and 31 hyperluminous infrared galaxies (LIRGs, ULIRGs, and HyLIRGs) over the redshift range 0.01 < z < 3.5 with a median redshift of 0.5. Presented here are the full spectral energy distributions (SEDs) for each of the sources compiled from the extensive multiwavelength data set from the ultraviolet (UV) to the far-infrared. A catalog of the general properties of the sample (including the photometry, redshifts, and L{sub IR}) is included with this paper. We find that the overall shape of the SED and trends with L{sub IR} (e.g., IR color temperatures and optical-IR ratios) are similar to what has been seen in studies of local objects; however, our large sample allows us to see the extreme spread in UV to near-infrared colors spanning nearly 3 orders of magnitude. In addition, using SED fits we find possible evidence for a subset of cooler ultraluminous objects than observed locally. However, until direct observations at longer wavelengths are obtained, the peak of emission and the dust temperature cannot be well constrained. We use these SEDs, along with the deep radio and X-ray coverage of the field, to identify a large sample of candidate active galactic nuclei (AGNs). We find that the fraction of AGNs increases strongly with L{sub IR}, as it does in the local universe, and that nearly 70% of ULIRGs and all HyLIRGs likely host a powerful AGN.

79 ASTRONOMY AND ASTROPHYSICS↗

LITHIUM ABUNDANCES IN A SAMPLE OF PLANET-HOSTING DWARFS

This work presents a homogeneous determination of lithium abundances in a large sample of giant-planet-hosting stars (N = 117) and a control sample of disk stars without detected planets (N = 145). The lithium abundances were derived using a detailed profile fitting of the Li I doublet at 6708 A in LTE. The planet-hosting and comparison stars were chosen to have significant overlap in their respective physical properties, including effective temperatures, luminosities, masses, metallicities, and ages. The combination of uniform data and homogeneous analysis with well-selected samples makes this study well suited to probe for possible differences in the lithium abundances found in planet-hosting stars. An overall comparison between the two samples reveals no obvious differences between stars with and without planets. A closer examination of the behavior of the Li abundances over a narrow range of effective temperature (5700 K {<=} T{sub eff} {<=} 5850 K) indicates subtle differences between the two stellar samples; this temperature range is particularly sensitive to various physical processes that can deplete lithium. In this T{sub eff} range, planet-hosting stars have lower Li abundances (by {approx}0.26 dex on average) than the comparison stars, although this segregation may be influenced by combining stars from a range of ages, metallicities, and masses. When stars with very restricted ranges in metallicity ([Fe/H] = 0.00 to +0.20 dex) and mass (M {approx} 1.05-1.15 M{sub sun}) are compared, however, both stars with and without planets exhibit similar behaviors in the lithium abundance with stellar age, suggesting that there are no differences in the lithium abundances between stars with planets and stars not known to have planets.

79 ASTRONOMY AND ASTROPHYSICS↗

THE PROPERTIES OF X-RAY COLD FRONTS IN A STATISTICAL SAMPLE OF SIMULATED GALAXY CLUSTERS

We examine the incidence of cold fronts in a large sample of galaxy clusters extracted from a (512 h {sup -1} Mpc) hydrodynamic/N-body cosmological simulation with adiabatic gas physics computed with the Enzo adaptive mesh refinement code. This simulation contains a sample of roughly 4000 galaxy clusters with M {>=}10{sup 14} M{sub sun} at z = 0. For each simulated galaxy cluster, we have created mock 0.3-8.0 keV X-ray observations and spectroscopic-like temperature maps. We have searched these maps with a new automated algorithm to identify the presence of cold fronts in projection. Using a threshold of a minimum of 10 cold front pixels in our images, corresponding to a total comoving length L{sub cf}>156 h {sup -1} kpc, we find that roughly 10%-12% of all projections in a mass-limited sample would be classified as cold front clusters. Interestingly, the fraction of clusters with extended cold front features in our synthetic maps of a mass-limited sample trends only weakly with redshift out to z = 1.0. However, when using different selection functions, including a simulated flux limit, the trending with redshift changes significantly. The likelihood of finding cold fronts in the simulated clusters in our sample is a strong function of cluster mass. In clusters with M>7.5 x 10{sup 14} M{sub sun} the cold front fraction is 40%-50%. We also show that the presence of cold fronts is strongly correlated with disturbed morphology as measured by quantitative structure measures. Finally, we find that the incidence of cold fronts in the simulated cluster images is strongly dependent on baryonic physics.

79 ASTRONOMY AND ASTROPHYSICS↗

H I CONTENT AND OPTICAL PROPERTIES OF FIELD GALAXIES FROM THE ALFALFA SURVEY. I. SELECTION OF A CONTROL SAMPLE

We report results from a study of the H I content and stellar properties of nearby galaxies detected by the Arecibo Legacy Fast ALFA blind 21 cm line survey and the Sloan Digital Sky Survey. We consider two declination strips covering a total area of 9 hr x 16 deg in the general direction of the Virgo Cluster. The present analysis focuses on gas-rich galaxies expected to show little or no evidence of interaction with their surroundings. We seek to assemble a control sample suitable for providing absolute measures of the H I content of gaseous objects, as well as to study the relationship between H I emission and widely used optical measures of morphology. From a database which includes more than 15,000 H I detections, we have assembled three samples that could provide adequate H I standards. The most reliable results are obtained with a sample of 5647 sources found in low-density environments, as defined by a nearest neighbor approach. The other two samples contain several hundred relatively isolated galaxies each, as determined from standard isolation algorithms based either on a combination of spectroscopic and photometric information or solely on photometric data. We find that isolated objects are not particularly gas-rich compared to their low-density-environment counterparts, while they suffer from selection bias and span a smaller dynamic range. All this makes them less suitable for defining a reference for H I content. We have explored the optical morphology of gaseous galaxies in quiet environments, finding that, within the volume surveyed, the vast majority of them display unequivocal late-type galaxy features. In contrast, bona fide gas-rich early-type systems account only for a negligible fraction of the 21 cm detections. We argue that H I emission provides the most reliable way to determine the morphological population to which a galaxy belongs. We have also observed that the color distribution of flux-limited samples of optically selected field H I emitters does not vary significantly with increasing distance, while that of non-detections becomes notably redder. This result suggests that the colors and H I masses of gas-rich galaxies cannot be very closely related.

79 ASTRONOMY AND ASTROPHYSICS↗

RHAPSODY. II. SUBHALO PROPERTIES AND THE IMPACT OF TIDAL STRIPPING FROM A STATISTICAL SAMPLE OF CLUSTER-SIZE HALOS

We discuss the properties of subhalos in cluster-size halos, using a high-resolution statistical sample: the RHAPSODY simulations introduced in Wu et al. We demonstrate that the criteria applied to select subhalos have significant impact on the inferred properties of the sample, including the scatter in the number of subhalos, the correlation between the subhalo number and formation time, and the shape of subhalos' spatial distribution and velocity structure. We find that the number of subhalos, when selected using the peak maximum circular velocity in their histories (a property expected to be closely related to the galaxy luminosity), is uncorrelated with the formation time of the main halo. This is in contrast to the previously reported correlation from studies where subhalos are selected by the current maximum circular velocity; we show that this difference is a result of the tidal stripping of the subhalos. We also find that the dominance of the main halo and the subhalo mass fraction are strongly correlated with halo concentration and formation history. These correlations are important to take into account when interpreting results from cluster samples selected with different criteria. Our sample also includes a fossil cluster, which is presented separately and placed in the context of the rest of the sample.

79 ASTRONOMY AND ASTROPHYSICS↗

Black hole mass estimates and emission-line properties of a sample of redshift z > 6.5 quasars

We present the analysis of optical and near-infrared spectra of the only four z > 6.5 quasars known to date, discovered in the UKIDSS-LAS and VISTA-VIKING surveys. Our data set consists of new Very Large Telescope/X-Shooter and Magellan/FIRE observations. These are the best optical/NIR spectroscopic data that are likely to be obtained for the z > 6.5 sample using current 6-10 m facilities. We estimate the black hole (BH) mass, the Eddington ratio, and the Si IV/C IV, C III]/C IV, and Fe II/Mg II emission-line flux ratios. We perform spectral modeling using a procedure that allows us to derive a probability distribution for the continuum components and to obtain the quasar properties weighted upon the underlying distribution of continuum models. The z > 6.5 quasars show the same emission properties as their counterparts at lower redshifts. The z > 6.5 quasars host BHs with masses of ∼10{sup 9} M{sub ☉} that are accreting close to the Eddington luminosity ((log(L{sub Bol}/L{sub Edd})) = –0.4 ± 0.2), in agreement with what has been observed for a sample of 4.0 < z < 6.5 quasars. By comparing the Si IV/C IV and C III]/C IV flux ratios with the results obtained from luminosity-matched samples at z ∼ 6 and 2 ≤ z ≤ 4.5, we find no evidence of evolution of the line ratios with cosmic time. We compare the measured Fe II/Mg II flux ratios with those obtained for a sample of 4.0 < z < 6.4 sources. The two samples are analyzed using a consistent procedure. There is no evidence that the Fe II/Mg II flux ratio evolves between z = 7 and z = 4. Under the assumption that the Fe II/Mg II traces the Fe/Mg abundance ratio, this implies the presence of major episodes of chemical enrichment in the quasar hosts in the first ∼0.8 Gyr after the Big Bang.

79 ASTRONOMY AND ASTROPHYSICS↗

Systematic uncertainties associated with the cosmological analysis of the first Pan-STARRS1 type Ia supernova sample

We probe the systematic uncertainties from the 113 Type Ia supernovae (SN Ia) in the Pan-STARRS1 (PS1) sample along with 197 SN Ia from a combination of low-redshift surveys. The companion paper by Rest et al. describes the photometric measurements and cosmological inferences from the PS1 sample. The largest systematic uncertainty stems from the photometric calibration of the PS1 and low-z samples. We increase the sample of observed Calspec standards from 7 to 10 used to define the PS1 calibration system. The PS1 and SDSS-II calibration systems are compared and discrepancies up to ∼0.02 mag are recovered. We find uncertainties in the proper way to treat intrinsic colors and reddening produce differences in the recovered value of w up to 3%. We estimate masses of host galaxies of PS1 supernovae and detect an insignificant difference in distance residuals of the full sample of 0.037 ± 0.031 mag for host galaxies with high and low masses. Assuming flatness and including systematic uncertainties in our analysis of only SNe measurements, we find w =−1.120{sub −0.206}{sup +0.360}(Stat){sub −0.291}{sup +0.269}(Sys). With additional constraints from Baryon acoustic oscillation, cosmic microwave background (CMB) (Planck) and H {sub 0} measurements, we find w=−1.166{sub −0.069}{sup +0.072} and Ω{sub m}=0.280{sub −0.012}{sup +0.013} (statistical and systematic errors added in quadrature). The significance of the inconsistency with w = –1 depends on whether we use Planck or Wilkinson Microwave Anisotropy Probe measurements of the CMB: w{sub BAO+H0+SN+WMAP}=−1.124{sub −0.065}{sup +0.083}.

79 ASTRONOMY AND ASTROPHYSICS↗

An X-ray-selected sample of candidate black holes in dwarf galaxies

We present a sample of hard X-ray-selected candidate black holes (BHs) in 19 dwarf galaxies. BH candidates are identified by cross-matching a parent sample of ∼44,000 local dwarf galaxies (M{sub ⋆}⩽3×10{sup 9} M{sub ⊙}, z<0.055) with the Chandra Source Catalog and subsequently analyzing the original X-ray data products for matched sources. Of the 19 dwarf galaxies in our sample, eight have X-ray detections reported here for the first time. We find a total of 43 point-like hard X-ray sources with individual luminosities L{sub 2−10 keV}∼10{sup 37}10{sup 40} erg s{sup −1}. Hard X-ray luminosities in this range can be attained by stellar-mass X-ray binaries (XRBs) and by massive BHs accreting at low Eddington ratio. We place an upper limit of 53% (10/19) on the fraction of galaxies in our sample hosting a detectable hard X-ray source consistent with the optical nucleus, although the galaxy center is poorly defined in many of our objects. We also find that 42% (8/19) of the galaxies in our sample exhibit statistically significant enhanced hard X-ray emission relative to the expected galaxy-wide contribution from low-mass and high-mass XRBs, based on the L{sub 2−10 keV}{sup XRB}−M{sub ⋆}−star formation rate relation defined by more massive and luminous systems. For the majority of these X-ray-enhanced dwarf galaxies, the excess emission is consistent with (but not necessarily due to) a nuclear X-ray source. Follow-up observations are necessary to distinguish between stellar-mass XRBs and active galactic nuclei powered by more massive BHs. In any case, our results support the notion that X-ray-emitting BHs in low-mass dwarf galaxies may have had an appreciable impact on reionization in the early universe.

79 ASTRONOMY AND ASTROPHYSICS↗