Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SEPARATION PROCESSES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

USE OF CEMENTITIOUS MATERIALS FOR SRS REACTOR FACILITY IN-SITU DECOMMISSIONING - 11620

The United States Department of Energy (US DOE) concept for facility in-situ decommissioning (ISD) is to physically stabilize and isolate in tact, structurally sound facilities that are no longer needed for their original purpose of, i.e., producing (reactor facilities), processing (isotope separation facilities) or storing radioactive materials. The Savannah River Site 105-P and 105-R Reactor Facility ISD requires about 250,000 cubic yards of grout to fill the below grade structure. The fills are designed to prevent subsidence, reduce water infiltration, and isolate contaminated materials. This work is being performed as a Comprehensive Environmental Response, Compensations and Liability Act (CERCLA) action and is part of the overall soil and groundwater completion projects for P- and R-Areas. Cementitious materials were designed for the following applications: (1) Below grade massive voids/rooms: Portland cement-based structural flowable fills for - Bulk filling, Restricted placement and Underwater placement. (2) Special below grade applications for reduced load bearing capacity needs: Cellular portland cement lightweight fill (3) Reactor vessel fills that are compatible with reactive metal (aluminum metal) components in the reactor vessels: Calcium sulfoaluminate flowable fill, and Magnesium potassium phosphate flowable fill. (4) Caps to prevent water infiltration and intrusion into areas with the highest levels of radionuclides: Portland cement based shrinkage compensating concrete. A system engineering approach was used to identify functions and requirements of the fill and capping materials. Laboratory testing was performed to identify candidate formulations and develop final design mixes. Scale-up testing was performed to verify material production and placement as well as fresh and cured properties. The 105-P and 105-R ISD projects are currently in progress and are expected to be complete in 2012. The focus of this paper is to describe the (1) grout mixes for filling the reactor vessels, and (2) a specialty grout mix to fill a selected portion of the P-Reactor Disassembly Basin. Details of the grout mixes designed for ISD of he SRS Reactor Disassembly Basins and below grade portions of the 105-Buildings was described elsewhere. Material property test results, placement strategies, full-scale production and delivery systems will also be described.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

TRENDS IN {sup 44}Ti AND {sup 56}Ni FROM CORE-COLLAPSE SUPERNOVAE

We compare the yields of {sup 44}Ti and {sup 56}Ni produced from post-processing the thermodynamic trajectories from three different core-collapse models-a Cassiopeia A progenitor, a double shock hypernova progenitor, and a rotating two-dimensional explosion-with the yields from exponential and power-law trajectories. The peak temperatures and densities achieved in these core-collapse models span several of the distinct nucleosynthesis regions we identify, resulting in different trends in the {sup 44}Ti and {sup 56}Ni yields for different mass elements. The {sup 44}Ti and {sup 56}Ni mass fraction profiles from the exponential and power-law profiles generally explain the tendencies of the post-processed yields, depending on which regions are traversed by the model. We find that integrated yields of {sup 44}Ti and {sup 56}Ni from the exponential and power-law trajectories are generally within a factor two or less of the post-process yields. We also analyze the influence of specific nuclear reactions on the {sup 44}Ti and {sup 56}Ni abundance evolution. Reactions that affect all yields globally are the 3{alpha}, p(e{sup -}, {nu}{sub e})n and n(e{sup +},{nu}-bar{sub e})p. The rest of the reactions are ranked according to their degree of impact on the synthesis of {sup 44}Ti. The primary ones include {sup 44}Ti({alpha}, p){sup 47}V, {sup 40}Ca({alpha}, {gamma}){sup 44}Ti, {sup 45}V(p, {gamma}){sup 46}Cr, {sup 40}Ca({alpha}, p){sup 43}Sc, {sup 17}F({alpha}, p){sup 20}Ne, {sup 21}Na({alpha}, p){sup 24}Mg, {sup 41}Sc(p, {gamma}){sup 42}Ti, {sup 43}Sc(p, {gamma}){sup 44}Ti, {sup 44}Ti(p, {gamma}){sup 45}V, and {sup 57}Ni(p, {gamma}){sup 58}Cu, along with numerous weak reactions. Our analysis suggests that not all {sup 44}Ti need to be produced in an {alpha}-rich freeze-out in core-collapse events, and that reaction rate equilibria in combination with timescale effects for the expansion profile may account for the paucity of {sup 44}Ti observed in supernova remnants.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Positive effect of Sc and Zr on globular microstructure formation in AA7075 thixoforming feedstock

One of methods of obtaining a fine globular microstructure in a semi-solid range, necessary for thixoforming process, is modifiers additions. For this purpose 0.5 weight percent of modifying elements-scandium and zirconium-was added to 7075 alloy. The microstructure of such alloy consisted of homogeneously distributed globular grains of solid solution with the following chemical composition: Mg - 1.9%, Al - 91.6%, Cu - 1.0%, Zn - 5.5%(all in wt.%). Quantitative metallographic analysis showed that the average grain size was 23.5 {mu}m, much smaller than in the alloy without additions and 3.08% volume fraction of precipitates in the form of a layer between spherical {alpha}(Al) grains. X-ray phase analysis of the 7075 alloy with Sc and Zr additions confirmed the dominant presence of aluminum solid solution and the intermetallic hexagonal phase MgZn{sub 2}. Electron diffraction pattern confirmed location of {eta}MgZn{sub 2} phase at the grain boundaries. EDS chemical analysis of the {eta}MgZn{sub 2} phase showed following content of elements: Mg - 17.2%, Al - 20.4%, Cu - 27.8%, Zn - 34.6%. The larger amount of Cu and Al indicated non-stoichiometry of the {eta} phase, which can be presented with a formula [Mg(Zn,Al,Cu){sub 2}]. Additionally, inside the aluminum solution, small, square-shaped precipitations enriched with Sc and Zr were observed. Electron diffraction pattern allowed identification of the precipitates as cubic Al{sub 3}(Sc,Zr) phase. The average hardness of feedstock was 105 HV5. DSC analysis during heating of the alloy enabled the estimation of a solidus line, at temperature of 548 deg. C and a liquidus line at temperature: 656 deg. C. For cooling, the temperatures for solidus and liquidus were 545 deg. C and 636 deg. C respectively. Additionally, the relation of liquid phase as a function of temperature was determined. Measurements of rheological properties in the semi-solid range, using the Searl system indicated that an increase of a particle size leads to an observable decrease of viscosity during isothermal shearing.

36 MATERIALS SCIENCE↗

Toxicity mitigation and solidification of municipal solid waste incinerator fly ash using alkaline activated coal ash

Highlights: Black-Right-Pointing-Pointer Incinerator fly ash (IFA) is added to an alkali activated coal fly ash (CFA) matrix. Black-Right-Pointing-Pointer Means of stabilizing the incinerator ash for use in construction applications. Black-Right-Pointing-Pointer Concrete made from IFA, CFA and IFA-CFA mixes was chemically characterized. Black-Right-Pointing-Pointer Environmentally friendly solution to IFA disposal by reducing its toxicity levels. - Abstract: Municipal solid waste (MSW) incineration is a common and effective practice to reduce the volume of solid waste in urban areas. However, the byproduct of this process is a fly ash (IFA), which contains large quantities of toxic contaminants. The purpose of this research study was to analyze the chemical, physical and mechanical behaviors resulting from the gradual introduction of IFA to an alkaline activated coal fly ash (CFA) matrix, as a mean of stabilizing the incinerator ash for use in industrial construction applications, where human exposure potential is limited. IFA and CFA were analyzed via X-ray fluorescence (XRF), X-ray diffraction (XRD) and Inductive coupled plasma (ICP) to obtain a full chemical analysis of the samples, its crystallographic characteristics and a detailed count of the eight heavy metals contemplated in US Title 40 of the Code of Federal Regulations (40 CFR). The particle size distribution of IFA and CFA was also recorded. EPA's Toxicity Characteristic Leaching Procedure (TCLP) was followed to monitor the leachability of the contaminants before and after the activation. Also images obtained via Scanning Electron Microscopy (SEM), before and after the activation, are presented. Concrete made from IFA, CFA and IFA-CFA mixes was subjected to a full mechanical characterization; tests include compressive strength, flexural strength, elastic modulus, Poisson's ratio and setting time. The leachable heavy metal contents (except for Se) were below the maximum allowable limits and in many cases even below the reporting limit. The leachable Chromium was reduced from 0.153 down to 0.0045 mg/L, Arsenic from 0.256 down to 0.132 mg/L, Selenium from 1.05 down to 0.29 mg/L, Silver from 0.011 down to .001 mg/L, Barium from 2.06 down to 0.314 mg/L and Mercury from 0.007 down to 0.001 mg/L. Although the leachable Cd exhibited an increase from 0.49 up to 0.805 mg/L and Pd from 0.002 up to 0.029 mg/L, these were well below the maximum limits of 1.00 and 5.00 mg/L, respectively.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Kick processes in the merger of two colliding black holes

We examine numerically the process of momentum extraction by gravitational waves in the merger of two colliding black holes, in the realm of Robinson-Trautman spacetimes. The initial data have already a common horizon so that the evolution covers the post-merger phase up to the final configuration of the remnant black hole. The analysis of the momentum flux carried out by gravitational waves indicates that two distinct regimes are present in the post-merger phase: (i) an initial accelerated regime, followed by (ii) a deceleration regime in which the deceleration increases rapidly towards a maximum and then decreases to zero, when the gravitational wave emission ceases. The analysis is based on the Bondi-Sachs conservation law for the total momentum of the system. We obtain the total kick velocity V{sub k} imparted on the merged black hole during the accelerated regime (i) and the total antikick velocity V{sub ak} during the decelerated regime (ii), by evaluating the impulse of the gravitational wave flux during both regimes. The distributions of both V{sub k} and V{sub ak} as a function of the symmetric mass ratio {eta} satisfy a simple {eta}-scaling law motivated by post-Newtonian analytical estimates. In the {eta}-scaling formula the Newtonian factor is dominant in the decelerated regime, that generates V{sub ak}, contrary to the behavior in the initial accelerated regime. For an initial infalling velocity v/c{approx_equal}0.462 of each individual black hole we obtain a maximum kick V{sub k{approx_equal}}6.4 km/s at {eta}{approx_equal}0.209, and a maximum antikick V{sub ak{approx_equal}}109 km/s at {eta}{approx_equal}0.205. The net antikick velocity (V{sub ak}-V{sub k}) also satisfies a similar {eta}-scaling law with a maximum approximately 102 km/s also at {eta}{approx_equal}0.205, qualitatively consistent with results from numerical relativity simulations, and post-Newtonian evaluations of binary black hole inspirals. For larger values of the initial data parameter v/c substantial larger values of the net antikick velocity are obtained. Based on the several velocity variables obtained, we discuss a possible definition of the center-of-mass motion of the merged system.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High rate mesophilic, thermophilic, and temperature phased anaerobic digestion of waste activated sludge: A pilot scale study

Highlights: Black-Right-Pointing-Pointer High temperatures were tested in single and two-stage anaerobic digestion of waste activated sludge. Black-Right-Pointing-Pointer The increased temperature demonstrated the possibility of improving typical yields of the conventional mesophilic process. Black-Right-Pointing-Pointer The temperature phased anaerobic digestion process (65 + 55 Degree-Sign C) showed the best performances with yields of 0.49 m{sup 3}/kgVS{sub fed}. Black-Right-Pointing-Pointer Ammonia and phosphate released from solids destruction determined the precipitation of struvite in the reactor. - Abstract: The paper reports the findings of a two-year pilot scale experimental trial for the mesophilic (35 Degree-Sign C), thermophilic (55 Degree-Sign C) and temperature phased (65 + 55 Degree-Sign C) anaerobic digestion of waste activated sludge. During the mesophilic and thermophilic runs, the reactor operated at an organic loading rate of 2.2 kgVS/m{sup 3}d and a hydraulic retention time of 20 days. In the temperature phased run, the first reactor operated at an organic loading rate of 15 kgVS/m{sup 3}d and a hydraulic retention time of 2 days while the second reactor operated at an organic loading rate of 2.2 kgVS/m{sup 3}d and a hydraulic retention time of 18 days (20 days for the whole temperature phased system). The performance of the reactor improved with increases in temperature. The COD removal increased from 35% in mesophilic conditions, to 45% in thermophilic conditions, and 55% in the two stage temperature phased system. As a consequence, the specific biogas production increased from 0.33 to 0.45 and to 0.49 m{sup 3}/kgVS{sub fed} at 35, 55, and 65 + 55 Degree-Sign C, respectively. The extreme thermophilic reactor working at 65 Degree-Sign C showed a high hydrolytic capability and a specific yield of 0.33 gCOD (soluble) per gVS{sub fed}. The effluent of the extreme thermophilic reactor showed an average concentration of soluble COD and volatile fatty acids of 20 and 9 g/l, respectively. Acetic and propionic acids were the main compounds found in the acids mixture. Because of the improved digestion efficiency, organic nitrogen and phosphorus were solubilised in the bulk. Their concentration, however, did not increase as expected because of the formation of salts of hydroxyapatite and struvite inside the reactor.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

MECHANISTIC UNDERSTANDING OF CAUSTIC CRACKING OF CARBON STEELS

Liquid waste generated by the PUREX process for separation of nuclear materials is concentrated and stored in Type IV single-shell carbon steel tanks at the Savannah River Site (SRS). The Type IV tanks for this waste do not have cooling coils and have not undergone heat treatment to stress-relieve the tanks. After the waste is concentrated by evaporation, it becomes very alkaline and can cause stress corrosion cracking (SCC) and pitting corrosion of the tank materials. SRS has experienced leakage from non-stress-relieved waste tanks constructed of A285 carbon steel and pitting of A212 carbon steel tanks in the vapor space. An investigation of tank materials has been undertaken at SRS to develop a basic understanding of caustic SCC of A285 and A212 grade carbon steels exposed to aqueous solutions, primarily containing sodium hydroxide (NaOH), sodium nitrate (NaNO{sub 3}), and sodium nitrite (NaNO{sub 2}) at temperatures relevant to the operating conditions of both the F and H area plants. This report presents the results of this corrosion testing program. Electrochemical tests were designed using unstressed coupons in a simulated tank environment. The purpose of this testing was to determine the corrosion susceptibility of the tank materials as a function of chemical concentration, pH, and temperature. A285 and A516 (simulates A212 carbon steel) coupons were used to investigate differences in the corrosion of these carbon steels. Electrochemical testing included measurement of the corrosion potential and polarization resistance as well as cyclic potentiodynamic polarization (CPP) testing of coupons. From the CPP experiments, corrosion characteristics were determined including: corrosion potential (E{sub corr}), pitting or breakdown potential (E{sub pit}), and repassivation potential (E{sub prot}). CPP results showed no indications of localized corrosion, such as pitting, and all samples showed the formation of a stable passive layer as evidenced by the positive hysteresis during the scan. Analysis of the CPP data was performed to compare the corrosion susceptibility of the samples under different environmental conditions. Test results indicated that the most important factors affecting corrosion of the steel are the solution temperature, hydroxide concentration, and the material used in constructing the tanks. Variables that did not significantly affect the corrosion susceptibility of the steel were the nitrate or nitrite concentration and the atmosphere in the tank. The passivation current of the coupons increased exponentially with temperature. Longer-term studies of the passivation current are suggested based on results from the literature for iron in highly caustic environments. Polarization resistance studies showed a significant increase in corrosion rate at 125 C and 12 M hydroxide concentration when compared with tests at lower temperatures and lower hydroxide concentrations. Within the temperature and pH range of these tests, iron oxide, Fe{sub 3}O{sub 4}, becomes unstable and could account for the increased corrosion susceptibility. The applicability of these conditions should be confirmed and detailed surface studies should be conducted to determine the corrosion resistance of A285 and A516 carbon steels under these conditions. Surface science studies should also be conducted to determine the role of the carbon steel composition in preventing corrosion under these conditions.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Open quantum system approach to inclusive jet production in heavy-ion collisions

We derive a factorization formula for inclusive jet production in heavy-ion collisions using the tools of Effective Field Theory (EFT). We show how physics at widely separated scales in this process can be systematically separated by matching to EFTs at successively lower virtualities. Owing to a strong scale separation, we recover a vacuum-like DGLAP evolution above the jet scale, while the additional low-energy scales induced by the medium effectively probe the internal structure of the jet. As a result, the cross section can be written as a series with an increasing number of subjets characterized by perturbative matching coefficients each of which is convolved with a distinct function. These functions encode broadening, medium-induced radiations as well as quantum interference such as the Landau-Pomeranchuk-Migdal effect and color coherence dynamics to all orders in perturbation theory. As a first application of this EFT framework, we investigate the case of an unresolved jet and show how the cross section can be factorized and fully separate the jet dynamics from the universal physics of the medium. To compare to the existing literature, we explicitly compute the medium jet function at next-to-leading order in the coupling and leading order in medium opacity.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Application of the AMPLATZER Vascular Plug in Endovascular Occlusion of Dialysis Accesses

The purpose of this study was to share our initial experience with the AMPLATZER Vascular Plug (AVP) in occluding dialysis accesses. Between January 2007 and October 2008, five patients with autogenous and one patient with prosthetic accesses were referred for endovascular occlusion owing to central venous obstruction (n = 4) and dialysis-associated steal syndrome (n = 2) leading to disabling complications. We used a single AVP in two patients, double AVPs in two patients, and double AVPs and n-butyl 2-cyanoacrylate in one patient with an autogenous access. Two coils were deployed between two AVPs to occlude the prosthetic graft. Immediate success was achieved in all patients, with no complications. Mean follow-up time was 13 months (range, 1-21 months) and none of the patients had experienced symptom recurrence as of the time of writing. The AVP allows simple, precise, and reliable dialysis access occlusion without significant complications when surgical ligation is not preferred. It can be used with other embolizing agents to provide occlusion in the case of failure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Peripheral Stent Placement in Hemodialysis Grafts

The purpose of the present study was to evaluate the clinical outcome of peripheral stent placement after failed balloon angioplasty in patients with grafts who are on hemodialysis. We examined 30 Wallstents that were placed in 26 patients because balloon angioplasty failed or early restenosis (<3 months) occurred within 3 months. We retrospectively reviewed 267 consecutive balloon angioplasties performed in 71 patients with graft access between August 2000 and March 2007. Stent placements accounted for 30 (11.2%) of the 267 balloon angioplasties. The clinical success rate of stent placement was 93.3% (28 of 30 stent placements). The 3-, 6-, and 12-month primary patency rates were 73.3%, 39.3%, and 17.7%, respectively. The 1-, 2-, and 3-year secondary patency rates were 90.2%, 83.8%, and 83.8%, respectively. Primary patency was significantly prolonged by stent placement after early restenosis compared with previous balloon angioplasty alone (P = 0.0059). Primary patency after stent placement was significantly lower than after successful balloon angioplasty without indications for stent placement (P = 0.0279). Secondary patency rates did not significantly differ between stent placement and balloon angioplasty alone. The mean number of reinterventions required to maintain secondary patency after stent placement was significantly larger than that after balloon angioplasty alone (Mann-Whitney U test, P = 0.0419). We concluded that peripheral stent placement for graft access is effective for salvaging vascular access after failed balloon angioplasty and for prolonging patency in early restenosis after balloon angioplasty. However, reinterventions are required to maintain secondary patency after stent placement. Furthermore, peripheral stent placement for graft access cannot achieve the same primary patency as balloon angioplasty alone.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Treatment of Autogenous Radiocephalic Fistulas with the 'Eighth Note' Deformity for Hemodialysis

The purpose of this paper is to describe a unique 'eighth note' deformity of the autogenous radiocephalic fistula for hemodialysis and to retrospectively evaluate the efficacy and safety of its endovascular treatment. Over 3 years, a total of 808 patients and 558 autogenous radiocephalic fistulas were treated for vascular access dysfunction or thrombosis. These included 14 fistulas in 14 patients (9 men, 5 women; mean age, 58.2 {+-} 2.8 years; range 27-79 years) whose fistulograms before treatment resembled a musical note, the eighth note. Endovascular treatment sought to remodel the deformed vascular access to a classic radiocephalic fistula and increase the number of cannulation sites available for hemodialysis. The technical and clinical success rates were each 92.8% (13/14). Fistula remodeling was successful in 13 patients. The postintervention primary patency was 100% at 90 days, 91.7 {+-} 0.8% at 120 days, 78.6 {+-} 13.9% at 180 days, 62.9 {+-} 17.9% at 360 days, 31.4 {+-} 24.0% at 540 days, and 0% at 720 days. The postintervention secondary patency was 100% at 90 days, 100% at 120 days, 100% at 180 days, 85.7 {+-} 13.2% at 360 days, and 85.7 {+-} 13.2% at 720 days. No major complications were noted. Minor complications were found in 71.4% of patients, all of which resolved spontaneously. In conclusion, endovascular treatment of fistulas with the eighth note deformity can effectively increase the number of available cannulation sites, facilitate fistula maturation, and facilitate thromboaspiration after fistula thrombosis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transhepatic Guidance of Translumbar Hemodialysis Catheter Placement in the Setting of Chronic Infrarenal IVC Occlusion

When patients with end-stage renal disease have exhausted both conventional and unconventional venous access options, creative solutions must be sought for hemodialysis catheter placement in order to ensure survival. This case describes a patient in urgent need of a dialysis catheter despite total occlusion of the jugular, subclavian, and femoral veins. Occlusion of the inferior vena cava (IVC) and right renal vein resulted in failed attempts at translumbar catheter placement. A gooseneck snare was temporarily advanced through the liver to the IVC for use as a fluoroscopic target to facilitate successful single-puncture, translumbar catheterization.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Retrospective Comparative Study of Tunneled Haemodialysis Catheters Inserted Through Occluded or Collateral Veins Versus Conventional Methods

Tunneled hemodialysis catheters become essential in dialysis access when there is no possibility of using a functioning arteriovenous fistula. Collateral or occluded veins visible on ultrasound are used for puncture and passage of catheters into the central venous system. Chronically occluded veins are crossed with guidewires to allow dilatation and subsequent passage of hemodialysis catheters. We performed a retrospective analysis of patient demographics, comorbidities, procedural complications, functional survival, performance, and history of previous vascular access. The study group was compared with two control groups in which dialysis catheters were inserted either by radiologists in the interventional suite or by clinicians on the wards. Nineteen patients from the study group were compared with same number of patients in both control groups. The mean age of the study group was higher compared with the control groups. There was no significant difference in mean functional survival, infection rates, dialysis pump speeds in the first 2 weeks, and procedural complications between the study group and the controls. The study group had a significantly higher number of previous vascular access interventions, longer dialysis careers, and more comorbidities. Tunneled dialysis catheter placement by way of collateral or occluded veins appears safe and effective. These techniques give the operator further options when faced with patients possessing challenging vascular access. Indeed, there may be a case for preferential use of these veins to keep patent central veins in reserve.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of Intravascular Iodinated Contrast Media on Natural Course of End-Stage Renal Disease Progression in Hemodialysis Patients: A Prospective Study

We evaluated the impact of intravascular iodinated contrast medium on residual diuresis in hemodialyzed patients. Two groups of clinically stable hemodialyzed patients with residual diuresis minimally 500 ml of urine per day were studied. The patients from the first group were given iso-osmolal contrast agent iodixanol (Visipaque, GE Healthcare, United Kingdom) in concentration of iodine 320 mg/ml with osmolality 290 mOsm/kg of water during the endovascular procedure. The second control group was followed without contrast medium administered. Residual diuresis and residual renal excretory capacity expressed as 24-h calculated creatinine clearance were evaluated in the both groups after 6 months. The evaluated group included 42 patients who were given 99.3 ml of iodixanol in average (range, 60-180 ml). The control group included 45 patients. There was no statistically significant difference found between both groups in daily volume of urine (P = 0.855) and calculated clearance of creatinine (P = 0.573). We can conclude that residual diuresis is not significantly influenced by intravascular administration of iso-osmolal iodinated contrast agent (iodixanol) in range of volume from 60 to 180 ml in comparison to natural course of urinary output and residual renal function during end-stage renal disease. This result can help the nephrologist to decide which imaging method/contrast medium to use in dialyzed patients in current practice.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Early Experience with the Amplatzer Vascular Plug II for Occlusive Purposes in Arteriovenous Hemodialysis Access

The Amplatzer Vascular Plug Type II (AVP II) has proven effective in the therapeutic embolization of various vascular lesions. It benefits from very rapid occlusion of the target lesion and can be deployed, retrieved, and redeployed if required. There is no literature available on use of the AVP II in the maintenance, closure, and management of complicated arteriovenous access in hemodialysis patients. In this series, we present our clinical experience with the use of the AVP II for embolization of problematic hemodialysis access. The AVP II is a self-expandable Nitinol wire-mesh device. Mounted on a delivery wire it has the capability to be deployed, recaptured, and redeployed. In total seven patients (four males: one diabetic, all nonsmokers), with ages ranging from 44 to 81 years (mean, 63 years), were treated between July 2008 and January 2009. One patient had not started dialysis. The remaining six patients had varied histories, with the time on hemodialysis ranging from 1 to 21 years. Retrospective review of clinical notes revealed patient demographics, type of access, device size, deployment site, and outcomes. Indications for embolization included steal syndrome (one patient), high-flow tributaries (two patients), and limb swelling (four patients). All patients had clinical and sonographical follow-up to 3 months. Surgical ligation had either failed, was considered a contraindication due to concerns regarding wound healing, or was considered difficult due to complex venous anatomy. Only one device was used in each patient, ranging from 6 to 16 mm in diameter. Immediate technical success was seen in 100%. All these patients were followed up clinically in the vascular access radiology clinic at 4 weeks and 3 months. Occlusion of the treated vessel and resolution of symptoms were reconfirmed in 100% of cases at 3 months. It was also noted whether patients were having successful dialysis, if required. There were no complications. Average procedural time was 19 min. We conclude that the AVP II is an efficient, safe, and technically simple occlusion device for use in arteriovenous access.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cutaneous Bronchobiliary Fistula Treated with Tissucol Sealant

Bronchobiliary fistula is a rare and is an uncommon but severe complication of hydatid disease of the liver. Treatment has traditionally been surgical resection, but embolization and stent placement have been described. The invasive method seems to be a key component of patient treatment. We describe a case of a 58-year-old woman who, 25 years before, had undergone surgery for a hydatid cyst. A total cystectomy without previous puncture or parasite extraction was carried out. The lower aspect of the cyst was found to be completely perforated over the biliary duct. During the postoperative course, the patient had subphrenic right-sided pleural effusion and biliary fistula that subsided with medical treatment. Afterward, the patient came to the outpatient area of our hospital complaining of leakage of purulent exudate through the cutaneous opening, pain located on the right hypochondrium radiating to the right hemithorax, malaise, fever, chronic cough, and occasional vomiting of bile. Fistulography revealed an anfractuous cavity communicating with a residual cystic cavity on the right hepatic lobe. We observed communication with the intrahepatic canaliculi. Computed tomographic scan revealed a fistulous tract on the anterior liver border through the abdominal wall. There were no posttreatment complications. The patient is asymptomatic.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

PTA of Infrapopliteal Arteries: Long-term Clinical Follow-up and Analysis of Factors Influencing Clinical Outcome

This study was a retrospective analysis of patients with CLI who underwent infrapopliteal percutaneous transluminal angioplasty (PTA). The main goal was to evaluate clinical and morphological factors that influence the clinical outcome of PTA in long-term follow-up. A total of 1,445 PTA procedures were performed in 1,268 patients. Main indications for PTA included gangrene, nonhealing ulcers, or rest pain. The mean number of treated arteries was 1.77 artery/limb, and the majority of lesions were type TASC D. The technical success rate of PTA was 89% of intended-to-treat arteries. The main criterion of clinical success was functional limb salvage (LS). One-year follow-up involved 1,069 limbs. Primary and secondary 1-year LS rates were 76.1 and 84.4%, respectively. The effect of clinical and morphological parameters on the 1-year LS was that the only associated disease with an adverse effect on LS rate was DM combined with dialysis. Regarding limb preprocedural status, gangrene was clearly a negative predictor. The most important factor affecting LS was the number of patent arteries post-PTA: patients with 0, 1, 2, and 3 patent arteries had 1-year primary LS rates of 56.4, 73.1, 80.4, and 83%, respectively. Long-term follow-up of LS rates demonstrated secondary LS rates of 84.4, 78.8, and 73.3% at 1, 5, and 10 years. Every effort should be made to perform PTA for as many arteries as possible, even if TASC D type, to improve clinical outcome. Our study shows that repeat PTA is capable of keeping the long-term LS rate close to 75%.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Minimally Invasive Catheter Procedures to Assist Complicated Pacemaker Lead Extraction and Implantation in the Operating Room

We report on percutaneous catheter procedures in the operating room (OR) to assist complicated manual extraction or insertion of pacemaker (PM) and implantable cardioverter defibrillator leads. We retrospectively reviewed complicated PM revisions and implantations performed between 2004 and 2009 that required percutaneous catheter procedures performed in the OR. The type of interventional procedure, catheter and retrieval system used, venous access, success rates, and procedural complications were analyzed. In 41 (12 female and 29 male [mean age 62 {+-} 17 years]) of 3021 (1.4%) patients, standard manual retrieval of old leads or insertion of new leads was not achievable and thus required percutaneous catheter intervention for retrieval of misplaced leads and/or recanalisation of occluded central veins. Thirteen of 18 (72.2%) catheter-guided retrieval procedures for misplaced (right atrium [RA] or ventricle [RV; n = 3], superior vena cava [n = 2], brachiocephalic vein [n = 5], and subclavian vein [n = 3]) lead fragments in 16 patients were successful. Percutaneous catheter retrieval failed in five patients because there were extremely fixed or adhered lead fragments. Percutaneous transluminal angiography (PTA) of central veins for occlusion or high-grade stenosis was performed in 25 patients. In 22 of 25 patients (88%), recanalization of central veins was successful, thus enabling subsequent lead replacement. Major periprocedural complications were not observed. In the case of complicated manual PM lead implantation or revision, percutaneous catheter-guided extraction of misplaced lead fragments or recanalisation of central veins can be performed safely in the OR, thus enabling subsequent implantation or revision of PM systems in the majority of patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗