Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SEALS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

Electrical connectors including glass seals and methods of fabrication

An electrical connector comprises an outer shell, at least one pin, and an insulating seal. The outer shell includes at least one side wall defining a cavity and having an inner surface. The outer shell is formed from electrically conductive material. The pin is positioned within the cavity and is also formed from electrically conductive material. The insulating seal is configured to provide electrical isolation of the pin and fills the cavity between the inner surface of the side wall and the pin. The insulating seal is formed from glass doped with a transition metal oxide.

Eichorst, Dennis J.↗

Investigation of coherence of niobium-based resonators enabled by a fast-sealing microwave cavity

Resonators and qubits with a niobium (Nb) base metal layer achieve some of the highest coherence times in superconducting quantum devices. The performance of such devices is often limited by loss associated with two-level systems, which are found primarily at material surfaces and interfaces. The metal-air (MA) interface is a major contributor to device loss. In this work, we develop a fast-sealing microwave cavity that enables devices to be placed under vacuum within five minutes of oxide removal, thereby significantly reducing the MA interface loss compared to common device processing and packaging approaches. Using coplanar stripline resonators, we demonstrate that devices sealed in such a cavity exhibit internal quality factors exceeding one million at single-photon power. After re-exposure to air, the devices show downward resonance frequency shifts and quality factor degradations, quantitatively consistent with a model of Nb oxide regrowth. The fast-sealing microwave cavity provides a practical and consistent method to mitigate MA interface loss and sustain high coherence in Nb devices, and establishes a controlled platform for studying metal oxide regrowth kinetics and dielectric properties, the understanding of which is critical to achieving high coherence in superconducting quantum devices.

Zhang, C. [Waterloo U., IQC; Waterloo U.]↗

Blade and Rim Seal Design of a First Stage High Pressure Turbine for a 300 MWe Supercritical CO2 Power Cycle

A first stage high-pressure turbine (HPT) blade is optimized for a 300 MWe supercritical CO2 (sCO2) power cycle using the surrogate-assisted genetic algorithm optimizer in Numeca FINE/Design 3D with objectives of increasing efficiency and decreasing heat load to the blade. The National Institute of Standards and Technology Reference Fluid Thermodynamic and Transport Properties Database (NIST REFPROP) [1] data for supercritical CO2 is formatted into tables of bicubic polynomial coefficients for use in condensable gas simulations in FINE/Turbo. Nearly 3000 unique shapes are evaluated via three-dimensional Reynolds Averaged Navier Stokes simulations, yielding increases in efficiency of up to 0.85 percentage points and decreases in heat load of 14%. A final blade, deemed the advanced blade, is chosen for future experimental analysis. Following this, a squealer tip optimization is performed on both the baseline and advanced blade designs. This optimization resulted in a performance gain of 1.25 points in efficiency and 15% reduction in tip heat load compared to the baseline flat tip design at the same clearance. In tandem, an optimization of the rotor-stator platform rim seal is performed using a parametrized geometry allowing for straight, meandering, and knife seal cavities. This multi-objective optimization focuses on decreasing the cooling mass flow and increasing the heat flux from the rotor and stator disk. The optimization resulted in cooling mass flow decreases of up to 26% while maintaining the average heat flux on the rim seal.

Tuite, Logan↗

Measure Guideline: Air Sealing Attics in Multifamily Buildings

This Building America Measure Guideline is intended for owners, builders, contractors, homeowners, and other stakeholders in the multifamily building industry, and focuses on challenges found in existing buildings for a variety of housing types. It explains why air sealing is desirable, explores related health and safety issues, and identifies common air leakage points in multifamily buildingattics. In addition, it also gives an overview of materials and techniques typically used to perform air sealing work.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Geophysical and Mineralogical Controls on the Rheology of Fracture Slip and Seal Breaching (Final Report)

This work explores the geophysical and mineralogical controls on the rheology of fractures and faults to define the modes of permeability evolution and the potential for the breaching of seals for subsurface reservoirs. In particular, the work is arranged to determine the dynamic response of faults to shear reactivation (Parts I-III), their post slip and inter-seismic healing (Parts IV-V), their response to chemically reactive alteration (Parts VI-VII) and then upscaling via digital rock physics models (Parts IIX-XI). The work first defines the principal controls on frictional strength and stability in caprocks and unconventional reservoirs and their consequences for permeability evolution in shales (Part I). This linkage is extended to explore the impact of both mineralogy (Part II) and fracture roughness (Part III) on permeability evolution and to link this to the frictional and stability behavior of faults. The important impacts of post-slip healing during interseismic periods is then delineated (Part IV) and constrained using tightly controlled observations of reactivation displacements and permeability measurement (Part V). The role of corrosive fluids in both dissolving (Part VI) and transforming (Part VII) minerals within the fracture walls and cements is then explored, together with impacts on friction, stability and permeability. Finally, process-based models are applied to upscale the friction-stability-permeability response of both gouge-filled faults (Parts VIII and IX) and rough fractures (Part X) together with chemically-driven compaction impacting long-term interseismic sealing (Part XI).

58 GEOSCIENCES↗

Predicting the Performance of Edge Seal Materials for PV (Presentation)

Edge seal materials were evaluated using a 100-nm film of Ca deposited on glass and laminated to another glass substrate. As moisture penetrates the package it converts the Ca metal to transparent CaOH2 giving a clear indication of the depth to which moisture has entered. Using this method, we have exposed test samples to a variety of temperature and humidity conditions ranging from 45C and 10%RH up to 85C and 85% RH, to ultraviolet radiation and to mechanical stress. We are able to show that edge seal materials are capable of keeping moisture away from sensitive cell materials for the life of a module.

14 SOLAR ENERGY↗

Compliant alkali silicate sealing glass for solid oxide fuel cell applications: the effect of protective alumina coating on electrical stability in dual environment

An alkali-containing silicate glass was recently proposed as a potential sealant for solid oxide fuel cells (SOFC). The glass contains appreciable amount of alkalis and retains its glassy microstructure at elevated temperatures over time. It is more compliant as compared to conventional glass-ceramics sealants and could potentially heal cracks during thermal cycling. In previous papers the thermal cycle stability, thermal stability and chemical compatibility were reported with yttria-stabilized zirconia (YSZ) electrolyte and YSZ-coated ferritic stainless steel interconnect. In this paper, we report the electrical stability of the compliant glass with aluminized AISI441 interconnect material under DC load in dual environment at 700-800oC. Apparent electrical resistivity was measured with a 4-point method for the glass sealed between two aluminized AISI441 metal coupons as well as plain AISI441 substrates. The results showed good electrical stability with the aluminized AISI441 substrate, while unstable behavior was observed for un-coated substrates. In addition, interfacial microstructure was examined with scanning electron microscopy and correlated with the measured resistivity results. Overall, the alumina coating demonstrated good chemical stability with the alkali-containing silicate sealing glass under DC loading.

aluminization↗

Challenges of Achieving 2012 IECC Air Sealing Requirements in Multifamily Dwellings

​While previous versions of the International Energy Conservation Code (IECC) have included provisions to improve the air tightness of dwellings, for the first time, the 2012 IECC mandates compliance verification through blower door testing. Simply completing the Air Barrier and Insulation Installation checklist through visual inspection is no longer sufficient by itself. In addition, the 2012 IECC mandates a significantly stricter air sealing requirement. In Climate Zones 3 through 8, air leakage may not exceed 3 ACH50, which is a significant reduction from the 2009 IECC requirement of 7 ACH50. This requirement is for all residential buildings, which includes low-rise multifamily dwellings. While this air leakage rate requirement is an important component to achieving an efficient building thermal envelope, currently, the code language doesn't explicitly address differences between single family and multifamily applications. In addition, the 2012 IECC does not provide an option to sample dwellings for larger multifamily buildings, so compliance would have to be verified on every unit. With compliance with the 2012 IECC air leakage requirements on the horizon, several of CARB's multifamily builder partners are evaluating how best to comply with this requirement. Builders are not sure whether it is more practical or beneficial to simply pay for guarded testing or to revise their air sealing strategies to improve compartmentalization to comply with code requirements based on unguarded blower door testing. This report summarizes CARB's research that was conducted to assess the feasibility of meeting the 2012 IECC air leakage requirements in 3 multifamily buildings.

&#8203↗

Measure Guideline: Air Sealing Attics in Multifamily Buildings

This Building America Measure Guideline is intended for owners, builders, contractors, homeowners, and other stakeholders in the multifamily building industry, and focuses on challenges found in existing buildings for a variety of housing types. It explains why air sealing is desirable, explores related health and safety issues, and identifies common air leakage points in multifamily building attics. In addition, it also gives an overview of materials and techniques typically used to perform air sealing work.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Challenges of Achieving 2012 IECC Air Sealing Requirements in Multifamily Dwellings

While previous versions of the International Energy Conservation Code (IECC) have included provisions to improve the air tightness of dwellings, for the first time, the 2012 IECC mandates compliance verification through blower door testing. Simply completing the Air Barrier and Insulation Installation checklist through visual inspection is no longer sufficient by itself. In addition, the 2012 IECC mandates a significantly stricter air sealing requirement. In Climate Zones 3 through 8, air leakage may not exceed 3 ACH50, which is a significant reduction from the 2009 IECC requirement of 7 ACH50. This requirement is for all residential buildings, which includes low-rise multifamily dwellings. While this air leakage rate requirement is an important component to achieving an efficient building thermal envelope, currently, the code language doesn't explicitly address differences between single family and multifamily applications. In addition, the 2012 IECC does not provide an option to sample dwellings for larger multifamily buildings, so compliance would have to be verified on every unit. With compliance with the 2012 IECC air leakage requirements on the horizon, several of Consortium for Advanced Residential Building's (CARB’s) multifamily builder partners are evaluating how best to comply with this requirement. Builders are not sure whether it is more practical or beneficial to simply pay for guarded testing or to revise their air sealing strategies to improve compartmentalization to comply with code requirements based on unguarded blower door testing. This report summarizes CARB's research that was conducted to assess the feasibility of meeting the 2012 IECC air leakage requirements in 3 multifamily buildings.

2012 IECC↗

Tuscaloosa Marine Shale: Seal or Source? Petrophysical Comparative Study of Wells in SE Louisiana and SW Mississippi

The Tuscaloosa Marine Shale (TMS) is a versatile Late Cretaceous shale formation present in central and SE Louisiana and SW Mississippi, which drew attention because of the various roles played within the Tuscaloosa Group. In this paper, it is debated whether the Tuscaloosa Marine Shale can act as a source, reservoir, or seal all throughout the shale play or only in certain areas. Well log and core data from Adams County, Mississippi, are compared to data from East Feliciana Parish in Louisiana. Conclusions were drawn based on the results of well log analysis, X-ray Diffraction (XRD), porosity–permeability measurements, programmed pyrolysis, and fracture analysis. It was shown that the Tuscaloosa Marine Shale interval in SE Louisiana consists of important amounts of calcite, exhibits multiple natural fractures, has porosity values as high as 9.3%, and shows a TOC content of up to 2.8 wt%. On the other hand, samples from a well at the Cranfield field, MS, are characterized by considerably lower TOC values of around 0.88 wt%, porosities between 0.33% and 4%, and no serious fracturing. The formation demonstrates better reservoir and source potential in SE Louisiana and reliable CO2 sealing capacity in SW Mississippi. The analysis presented in this paper represents a holistic approach to the characterization of shale formations, is applicable to other plays around the world, and can be used as an integral part of CO2 sequestration or hydraulic fracturing programs.

04 OIL SHALES AND TAR SANDS↗

The impact of NRC guidance on concentration averaging on low level waste sealed source disposal - 11424

As part of its ongoing efforts to revise the Nuclear Regulatory Commission's (NRC) current position on blending to be risk-informed and performance based and its current review of the low-level waste classification codified in 10 CFR 61.55, the Nuclear Regulatory Commission (NRC) has stated that it may review the 1995 'Branch Technical Position on Concentration Averaging and Encapsulation' (BTP), which is still commonly used today. Such a review will have timely advantages, given the lack of commercial disposal availability within the United States for radioactive sealed sources that are in wide beneficial use across the country. The current application of the BTP guidance has resulted in an effective cap on commercial disposal for sources larger than 1.1 TBq (30 Ci). This paper will analyze how the BTP has been implemented with respect to sealed sources, what the implications have been for commercial disposal availability, and whether alternative packaging configurations could be considered for disposal.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Building America Case Study: Challenges of Achieving 2012 IECC Air Sealing Requirements in Multifamily Dwellings, Upstate New York (Fact Sheet)

While previous versions of the International Energy Conservation Code (IECC) have included provisions to improve the air tightness of dwellings, for the first time, the 2012 IECC mandates compliance verification through blower door testing. Simply completing the Air Barrier and Insulation Installation checklist through visual inspection is no longer sufficient by itself. In addition, the 2012 IECC mandates a significantly stricter air sealing requirement. In Climate Zones 3 through 8, air leakage may not exceed 3 ACH50, which is a significant reduction from the 2009 IECC requirement of 7 ACH50. This requirement is for all residential buildings, which includes low-rise multifamily dwellings. While this air leakage rate requirement is an important component to achieving an efficient building thermal envelope, currently, the code language doesn't explicitly address differences between single family and multifamily applications. In addition, the 2012 IECC does not provide an option to sample dwellings for larger multifamily buildings, so compliance would have to be verified on every unit. With compliance with the 2012 IECC air leakage requirements on the horizon, several of CARB's multifamily builder partners are evaluating how best to comply with this requirement. Builders are not sure whether it is more practical or beneficial to simply pay for guarded testing or to revise their air sealing strategies to improve compartmentalization to comply with code requirements based on unguarded blower door testing. This report summarizes CARB's research that was conducted to assess the feasibility of meeting the 2012 IECC air leakage requirements in 3 multifamily buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

New Whole-House Solutions Case Study: Challenges of Achieving 2012 IECC Air Sealing Requirements in Multifamily Dwellings, Upstate New York

While previous versions of the International Energy Conservation Code (IECC) have included provisions to improve the air tightness of dwellings, for the first time, the 2012 IECC mandates compliance verification through blower door testing. Simply completing the Air Barrier and Insulation Installation checklist through visual inspection is no longer sufficient; the 2012 IECC mandates a significantly stricter air sealing requirement. In Climate Zones 3 through 8, air leakage may not exceed 3 ACH50, which is a significant reduction from the 2009 IECC requirement of 7 ACH50. This requirement is for all residential buildings, which includes low-rise multifamily dwellings. While this air leakage rate requirement is an important component to achieving an efficient building thermal envelope, currently, the code language doesn't explicitly address differences between single family and multifamily applications. In addition, the 2012 IECC does not provide an option to sample dwellings for larger multifamily buildings, so compliance would have to be verified on every unit. With compliance with the 2012 IECC air leakage requirements on the horizon, several of Building America team Consortium for Advanced Residential Building's (CARB) multifamily builder partners are evaluating how best to comply with this requirement. Builders are not sure whether it is more practical or beneficial to simply pay for guarded testing or to revise their air sealing strategies to improve compartmentalization to comply with code requirements based on unguarded blower door testing. This report summarizes CARB's research that was conducted to assess the feasibility of meeting the 2012 IECC air leakage requirements in three multifamily buildings.

air leakage↗

Building America Top Innovations 2012: Attic Air Sealing Guidelines

This Building America Top Innovations profile describes the DOE-sponsored Guide to Attic Air Sealing by Building America research partner Building Science Corporation, which provides best practices for attic air sealing. The guide has had 21,000 views and 13,000 downloads since it was posted.

air sealing↗

Spent Sealed Sources Management in Switzerland - 12011

Information is provided about the international recommendations for the safe management of disused and spent sealed radioactive sources wherein the return to the supplier or manufacturer is encouraged for large radioactive sources. The legal situation in Switzerland is described mentioning the demand of minimization of radioactive waste as well as the situation with respect to the interim storage facility at the Paul Scherrer Institute (PSI). Based on this information and on the market situation with a shortage of some medical radionuclides the management of spent sealed sources is provided. The sources are sorted according to their activity in relation to the nuclide-specific A2-value and either recycled as in the case of high active sources or conditioned as in the case for sources with lower activity. The results are presented as comparison between recycled and conditioned activity for three selected nuclides, i.e. Cs-137, Co-60 and Am-241. (author)

07 ISOTOPE AND RADIATION SOURCES↗