Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SCaN”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

Resolution of Virtual Depth Sectioning from Four-Dimensional Scanning Transmission Electron Microscopy

Abstract One approach to three-dimensional structure determination using the wealth of scattering data in four-dimensional (4D) scanning transmission electron microscopy (STEM) is the parallax method proposed by Ophus et al. (2019. Advanced phase reconstruction methods enabled by 4D scanning transmission electron microscopy, Microsc Microanal25, 10–11), which determines the scattering matrix and uses it to synthesize a virtual depth-sectioning reconstruction of the sample structure. Drawing on an equivalence with a hypothetical confocal imaging mode, we derive contrast transfer and point spread functions for this parallax method applied to weakly scattering objects, showing them identical to earlier depth-sectioning STEM modes when only bright field signal is used, but that improved depth resolution is possible if dark field signal can be used. Through a simulation-based study of doped Si, we show that this depth resolution is preserved for thicker samples, explore the impact of shot noise on the parallax reconstructions, discuss challenges to making use of dark field signal, and identify cases where the interpretation of the parallax reconstruction breaks down.

3D imaging↗

Gold-gold luminosity increase in RHIC for a beam energy scan with colliding beam energies extending below the nominal injection energy

The Beam Energy Scan phase II (BES-II), performed in the Relativistic Heavy Ion Collider (RHIC) from 2019 to 2021, explored the phase transition between quark-gluon plasma and hadronic gas. BES-II exceeded the goal of a fourfold increase in the average luminosity over that achieved during Beam Energy Scan phase I (BES-I), at five gold beam energies: 9.8, 7.3, 5.75, 4.59, and 3.85 GeV / nucleon. This was accomplished by addressing several beam dynamics effects, including intrabeam scattering, beam-beam, space charge, beam instability, and field errors induced by superconducting magnet persistent currents. Some of these effects are especially detrimental at low energies. BES-II achievements are presented, and the measures taken to improve RHIC performance are described. These measures span the whole RHIC complex, including ion beam sources, injectors, beam lifetime improvements in RHIC, and operation with the world’s first bunched beam Low Energy RHIC electron Cooler (LEReC).

43 PARTICLE ACCELERATORS↗

Interpretable and Efficient Interferometric Contrast in Scanning Transmission Electron Microscopy with a Diffraction-Grating Beam Splitter

Efficient imaging of biomolecules, 2D materials and electromagnetic fields depends on retrieval of the phase of transmitted electrons. We demonstrate a method to measure phase in a scanning transmission electron microscope using a nanofabricated diffraction grating to produce multiple probe beams. The measured phase is more interpretable than phase-contrast scanning transmission electron microscopy techniques without an off-axis reference wave, and the resolution could surpass that of off-axis electron holography. Here, we apply the technique to image nanoparticles, carbon sub- strates and electric fields. The contrast observed in experiments agrees well with contrast predicted in simulations.

36 MATERIALS SCIENCE↗

Isotope effects in molecular structures and electronic properties of liquid water via deep potential molecular dynamics based on the SCAN functional

Here, Feynman path-integral deep potential molecular dynamics (PI-DPMD) calculations have been employed to study both light (H 2 O) and heavy water (D 2 O) within the isothermalisobaric ensemble. In particular, the deep neural network is trained based on ab initio data obtained from the strongly constrained and appropriately normed (SCAN) exchange-correlation functional. Because of the lighter mass of hydrogen than deuteron, the properties of light water are more influenced by nuclear quantum effect than those of heavy water. Clear isotope effects are observed and analyzed in terms of hydrogen-bond structure and electronic properties of water that are closely associated with experimental observables. The molecular structures of both liquid H 2 O and D 2 O agree well with the data extracted from scattering experiments. The delicate isotope effects on radial distribution functions and angular distribution functions are well reproduced as well. Our approach demonstrates that deep neural network combined with SCAN functional based ab initio molecular dynamics provides an accurate theoretical tool for modeling water and its isotope effects.

36 MATERIALS SCIENCE↗

Vortex dynamics induced by scanning SQUID susceptometry

In this work, we measured the local magnetic response of a niobium thin film by applying a millitesla-scale AC magnetic field using a micron-scale field coil and detecting the response with a micron-scale pickup loop in a scanning superconducting quantum interference device (SQUID) susceptometry measurement. Near the film's critical temperature, we observed a steplike nonlinear and dissipative magnetic response due to the dynamics of a small number of vortex-antivortex pairs induced in the film by the local applied AC field. We modeled the dynamics of the measurement using a combined two-dimensional London-Maxwell and time-dependent Ginzburg-Landau approach, allowing us to construct a detailed real-space picture of the vortex motion causing the observed dissipative response. This work pushes scanning SQUID susceptometry of two-dimensional superconductors beyond the regime of linear response and lays the foundation for microscopic studies of vortex dynamics and pinning in superconducting devices and more exotic materials systems.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Disentangling contributions to small-system collectivity via scans of light nucleus-nucleus collisions

The observation of multiparticle azimuthal correlations in high-energy small-system collisions has led to intense debate on its origin and the possible coexistence from two competing theoretical scenarios: one based on initial-state intrinsic momentum anisotropy, and the other based on final-state interaction model (FSM) collective response to the collision geometry. To complement the previous scan of asymmetric collision systems ( p +Au, d +Au, and He+Au), we propose a scan of small symmetric collision systems at the Brookhaven National Laboratory Relativistic Heavy Ion Collider, such as C+C, O+O, Al+Al, and Ar+Ar$\sqrt{s_\text{NN}}$ = 0.2 TeV , to provide further insights in disentangling contributions from these two scenarios. These symmetric small systems have the advantage of providing a better controlled initial geometry dominated by the average shape of the overlap region as opposed to fluctuation-driven geometries in asymmetric systems. In this work, a transport model is employed to investigate the expected geometry response in the FSM scenario. Different trends of elliptic flow with increasing charge particle multiplicity are observed between symmetric and asymmetric systems, whereas triangular flow appears to show a similar behavior. Furthermore, a comparison of O+O collisions at $\sqrt{s_\text{NN}}$ = 0.2 TeV and at $\sqrt{s_\text{NN}}$ = 2.76 ₋ 7 TeV as proposed at the CERN Large Hadron Collider, provides a unique opportunity to disentangle the collision geometry effects at the nucleon level from those arising from subnucleon fluctuations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A new Kirkpatrick–Baez-based scanning microscope for the Submicron Resolution X-ray Spectroscopy (SRX) beamline at NSLS-II

The development, construction, and first commissioning results of a new scanning microscope installed at the 5-ID Submicron Resolution X-ray Spectroscopy (SRX) beamline at NSLS-II are reported. The developed system utilizes Kirkpatrick–Baez mirrors for X-ray focusing. The instrument is designed to enable spectromicroscopy measurements in 2D and 3D with sub-200 nm spatial resolution. The present paper focuses on the design aspects, optical considerations, and specifics of the sample scanning stage, summarizing some of the initial commissioning results.

36 MATERIALS SCIENCE↗

Data-driven approach for synchrotron X-ray Laue microdiffraction scan analysis

A novel data-driven approach is proposed for analyzing synchrotron Laue X-ray microdiffraction scans based on machine learning algorithms. The basic architecture and major components of the method are formulated mathematically. It is demonstrated through typical examples including polycrystalline BaTiO 3 , multiphase transforming alloys and finely twinned martensite. The computational pipeline is implemented for beamline 12.3.2 at the Advanced Light Source, Lawrence Berkeley National Laboratory. The conventional analytical pathway for X-ray diffraction scans is based on a slow pattern-by-pattern crystal indexing process. Here, this work provides a new way for analyzing X-ray diffraction 2D patterns, independent of the indexing process, and motivates further studies of X-ray diffraction patterns from the machine learning perspective for the development of suitable feature extraction, clustering and labeling algorithms.

42 ENGINEERING↗

Geant4 simulation of clinical proton and carbon ion beams for the treatment of ocular melanomas with the full 3-D pencil beam scanning system

This work investigates the possibility to use carbon ion beams delivered with active scanning modality, for the treatment of ocular melanomas at the Centro Nazionale di Adroterapia Oncologica (CNAO) in Pavia. The radiotherapy with carbon ions offers many advantages with respect to the radiotherapy with protons or photons, such as a higher relative radio-biological effectiveness (RBE) and a dose release better localized to the tumor. The Monte Carlo (MC) Geant4 10.00 patch-03 toolkit is used to reproduce the complete CNAO extraction beam line, including all the active and passive components characterizing it. The simulation of proton and carbon ion beams and radiation scanned field is validated against CNAO experimental data. For the irradiation study of the ocular melanoma an eye-detector, representing a model of a human eye, is implemented in the simulation. Each element of the eye is reproduced with its chemical and physical properties. Inside the eye-detector a realistic tumor volume is placed and used as the irradiation target. A comparison between protons and carbon ions eye irradiations allows to study possible treatment benefits if carbon ions are used instead of protons. (authors)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Differential Multiphoton Laser Scanning Microscopy

Multifocal multiphoton laser scanning microscopy (mfMPLSM) in the biological and medical sciences has the potential to become a ubiquitous tool for obtaining high-resolution images at video rates. While current implementations of mfMPLSM achieve very high frame rates, they are limited in their applicability to essentially those biological samples that exhibit little or no scattering. In this paper, we report on a method for mfMPLSM in which whole-field detection with a single detector, rather than detection with a matrix of detectors, such as a charge-coupled device (CCD) camera, is implemented. This advance makes mfMPLSM fully compatible for use in imaging through scattering media. Further, we demonstrate that this method makes it possible to simultaneously obtain multiple images and view differences in excitation parameters in a single scan of the specimen.

47 OTHER INSTRUMENTATION↗

Impedance Scan of Inverter-Based Resources and Diesel Generator for Stability Analysis

Impedance-based methods are widely used for power system stability analysis with inverter-based resources (IBRs), e.g., assessing dynamic interactions between the power grid and an IBR, control interactions between multiple IBRs, and the sub-synchronous oscillation and damping phenomenon. Since it is difficult to get a numerical model 100% matching with the hardware IBR, using the hardware inverter directly to obtain its output impedance has become a prominent approach nowadays. Therefore, this article presents the impedance scan using hardware IBRs, and also a hardware diesel generator as it still stays with the grid before the grid completely goes to renewable. The devices under test (DuTs) for the impedance scan includes two 3-..phi.., 480 V, 60 Hz commercial grid-forming IBRs (one of 250 kVA and another of 125 kVA rating) in series with ..delta..-Y transformers, one 3-..phi.., 480 V, 60 Hz commercial grid-following IBR (of 125 kVA rating), and a 3-..phi.., 480 V, 60 Hz commercial diesel generator (of 187.5 kVA rating). Using voltage signals perturbed with sub-, inter-, and higher harmonic components, and measuring the current response, the positive-sequence impedances are computed via an offline-based post-analysis. Moreover, best-fit transfer functions are estimated that closely resemble the measured data points of the positive-sequence impedances. Based on the observations from various outcomes of the hardware experiments, this article also provides some fundamental insights on the equivalent positive-sequence impedance of a combination of multiple hardware components by comparing the estimated and the empirically computed impedances. A comparative insight on the damping capability of the DuTs using the positive-sequence impedances of the hardware is also discussed.

current measurement↗

Simplex‐based model for nanoparticle grain identification in four‐dimensional scanning transmission electron microscopy data

Grain identification in polycrystalline nanoparticles, for example, determining which crystal phases are present at each spatial location, is fundamental to materials characterisation. This is particularly challenging when grains overlap extensively, as commonly occurs in four-dimensional scanning transmission electron microscopy (4D-STEM) datasets. We propose a simplex-based model (SBM) in which each simplex vertex represents the diffraction pattern (DP) of a pure grain, and the simplex edges and interior represent overlapping grains. Our SBM grain identification algorithm operates on the Bragg disk (BD) data matrix distilled from the 4D-STEM data to identify the grain membership at each scan position, together with a BD feature matrix whose columns represent the DPs for each constituent grain, which is important for identifying the crystal structure of each grain. We solve the model using a two-stage algorithm. In Stage 1, we adapt a linear mixing algorithm to estimate an initial BD feature matrix whose columns represent DPs of potentially overlapping grains. Our Stage 2 algorithm incorporates sparsity considerations to transform the initial BD feature matrix so that its columns represent DPs of pure grains. Using simulated datasets with various grain configurations, we demonstrate that SBM recovers both the BD feature matrix and membership maps more accurately than existing methods, even when a grain lacks any pure region and completely overlaps with other grains.

4D-STEM segmentation↗

REGULATORY TESTING AND 3D SCANNING METHODOLOGY OF THE DPP-1 TYPE SHIPPING CONTAINER FOR NCT AND HAC TESTS

The safe transportation of radioactive material using appropriately designed and certified transportation packages is important to protect the public and environment. In the United States of America all transportation of radioactive material is regulated by the Department of Transportation (DOT) along with input by the Nuclear Regulatory Commission (NRC). All packages that contain radioactive material requires that it be transported and regulated by the requirements set by the DOT Class 7 hazardous material transportation. Federal regulations place strict administrative controls on the transport of radioactive materials. The two main goals for transporting radioactive materials are 1. Safety should be the primarily focused on the package because it is the first line of defense. 2. Package integrity should be directly related to the degree of the hazard of the radioactive material contents. The two-part goal ensures that the right package is used. Type B packages are designed to transport radioactive materials with the highest level of radioactivity. Examples of material transported in Type B packagings include spent nuclear fuel, high-level radioactive waste, and high concentrations of other radioactive materials. The purpose of this test protocol is to determine the effects of drop and thermal testing on package performance in a Type B shipping package (DPP-1). Required physical tests for the DPP-1 package include free drop, crush, puncture, penetration, compression, vibration, water spray, water immersion, and thermal. The preparation, regulatory testing, and post-test evaluation of a Type B shipping package tested to the 10 CFR 71.71 and 10 CFR 71.73 requirements will be presented. Six packages were tested and the responses when subjected to the HAC sequence of free drop, puncture, and thermal tests according to 10 CFR 71.73(c)(1), (c)(2), (c)(3) and (c)(4) were measured. The Free Drop, Crush and Puncture tests were performed at the NTRC in Knoxville, TN, and the Thermal tests were performed Southwest Research Institute in San Antonio, TX. The test units were subjected to a pre-operational leak testing before the NCT and HAC tests and a post-operational leak test and a helium leak test once regulatory testing was complete. Finally, all test units were scanned with a handheld blue light scanner to capture a 3D CAD geometry of the test units in the deformed shape. The handheld scanner provided the most effective and reliable way to acquire accurate 3D measurements of the test unit. The scanned geometry was sectioned in areas with deformation and the cross-section profile was measured to determine accurate and repeatable results of the deformed shape of the test units.

Martinez, Oscar↗

Uniform deposition of size-selected clusters using Lissajous scanning

Size-selected clusters can be deposited on the surface using size-selected cluster ion beams. However, because of the cross-sectional intensity distribution of the ion beam, it is difficult to define the coverage of the deposited clusters. The aggregation probability of the cluster depends on coverage, whereas cluster size on the surface depends on the position, despite the size-selected clusters are deposited. It is crucial, therefore, to deposit clusters uniformly on the surface. In this study, size-selected clusters were deposited uniformly on surfaces by scanning the cluster ions in the form of Lissajous pattern. Two sets of deflector electrodes set in orthogonal directions were placed in front of the sample surface. Triangular waves were applied to the electrodes with an irrational frequency ratio to ensure that the ion trajectory filled the sample surface. The advantages of this method are simplicity and low cost of setup compared with raster scanning method. The authors further investigated CO adsorption on size-selected Pt{sub n} (n = 7, 15, 20) clusters uniformly deposited on the Al{sub 2}O{sub 3}/NiAl(110) surface and demonstrated the importance of uniform deposition.

42 ENGINEERING↗

Atomic precision imaging with an on-chip scanning tunneling microscope integrated into a commercial ultrahigh vacuum STM system

In this article, we replace the Z axis of the piezotube of a conventional Ultrahigh-Vacuum (UHV) Scanning Tunneling Microscope (STM) with a one-degree-of-freedom Microelectromechanical-System (MEMS) nanopositioner. As a result, a hybrid system is realized in which motions in the XY plane are carried out by the piezotube, while the MEMS device performs the Z-axis positioning with a smaller footprint and higher sensitivity. With the proposed system and a feedback loop, STM imaging is conducted on an H-passivated Si (100)-2×1 sample in a UHV condition, demonstrating that this on-chip STM is conducive to atomic precision scanning tunneling microscopy.

Engineering↗

Light-sheet microscopy by confocal line scanning of dual-Bessel beams

Here, we have developed a light-sheet microscope that uses confocal scanning of dual-Bessel beams for illumination. A digital micromirror device (DMD) is placed in the intermediate image plane of the objective used to collect fluorescence and is programmed with two lines of pixels in the “on” state such that the DMD functions as a spatial filter to reject the out-of-focus background generated by the side-lobes of the Bessel beams. The optical sectioning and out-of-focus background rejection capabilities of this microscope were demonstrated by imaging of fluorescently stained actin in human A431 cells. The dual-Bessel beam system enables twice as many photons to be detected per imaging scan, which is useful for low light applications (e.g., single-molecule localization) or imaging at high speed with a superior signal to noise. While demonstrated for two Bessel beams, this approach is scalable to a larger number of beams.

confocal microscopy↗

Infrared Scattering Scanning Near-Field Optical Microscopy Using An External Cavity Quantum Cascade Laser For Nanoscale Chemical Imaging And Spectroscopy of Explosive Residues

Infrared scattering scanning near-field optical microscopy (s-SNOM) is an apertureless superfocusing technique that uses the antenna properties of a conducting atomic force microscope (AFM) tip to achieve infrared spatial resolution below the diffraction limit. The instrument can be used either in imaging mode, where a fixed wavelength light source is tuned to a molecular resonance and the AFM raster scans an image, or in spectroscopy mode where the AFM is held stationary over a feature of interest and the light frequency is varied to obtain a spectrum. In either case, a strong, stable, coherent infrared source is required. Here we demonstrate the integration of a broadly tunable external cavity quantum cascade laser (ECQCL) into an s-SNOM and use it to obtain infrared spectra of microcrystals of chemicals adsorbed onto gold substrates. Residues of the explosive compound tetryl was deposited onto gold substrates. s-SNOM experiments were performed in the 1260-1400 cm-1 tuning range of the ECQCL, corresponding to the NO2 symmetric stretch vibrational fingerprint region. Vibrational infrared spectra were collected on individual chemical domains with a collection area of *500nm2 and compared to ensemble averaged far-field reflection-absorption infrared spectroscopy (RAIRS) results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Transfer of autocollimator calibration for use with scanning gantry profilometers for accurate determination of surface slope and curvature of state-of-the-art x-ray mirrors

X-ray optics, desired for beamlines at free-electron-laser and diffraction-limited-storage-ring x-ray light sources, must have almost perfect surfaces, capable of delivering light to experiments without significant degradation of brightness and coherence. To accurately characterize such optics at an optical metrology lab, two basic types of surface slope profilometers are used: The long trace profilers (LTPs) and nanometer optical measuring (NOM) like angular deflectometers, based on electronic autocollimator (AC) ELCOMAT-3000. The inherent systematic errors of the instrument's optical sensors set the principle limit to their measuring performance. Where autocollimator of a NOM-like profiler may be calibrated at a unique dedicated facility, this is for a particular configuration of distance, aperture size, and angular range that does not always match the exact use in a scanning measurement with the profiler. Here we discuss the developed methodology, experimental set-up, and numerical methods of transferring the calibration of one reference AC to the scanning AC of the Optical Surface Measuring System (OSMS), recently brought to operation at the ALS Xray Optics Laboratory. We show that precision calibration of the OSMS performed in three steps, allows us to provide high confidence and accuracy low-spatial-frequency metrology and not â€print into' measurements the inherent systematic error of tool in use. Here, with the examples of the OSMS measurements with a state-of-The-Art x-ray aspherical mirror, available from one of the most advanced vendors of X-ray optics, we demonstrate the high efficacy of the developed calibration procedure. The results of our work are important for obtaining high reliability data, needed for sophisticated numerical simulations of beamline performance and optimization of beamline usage of the optics. This work was supported by the U. S. Department of Energy under contract number DE-AC02-05CH11231.

47 OTHER INSTRUMENTATION↗