Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SAMPLE POSITIONING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

Response characteristics of laser diffraction particle size analyzers - Optical sample volume extent and lens effects

The response characteristics of laser diffraction particle sizing instruments were studied theoretically and experimentally. In particular, the extent of optical sample volume and the effects of receiving lens properties were investigated in detail. The experimental work was performed with a particle size analyzer using a calibration reticle containing a two-dimensional array of opaque circular disks on a glass substrate. The calibration slide simulated the forward-scattering characteristics of a Rosin-Rammler droplet size distribution. The reticle was analyzed with collection lenses of 63 mm, 100 mm, and 300 mm focal lengths using scattering inversion software that determined best-fit Rosin-Rammler size distribution parameters. The data differed from the predicted response for the reticle by about 10 percent. A set of calibration factor for the detector elements was determined that corrected for the nonideal response of the instrument. The response of the instrument was also measured as a function of reticle position, and the results confirmed a theoretical optical sample volume model presented here.

Hirleman, E. D.↗

The MOSDEF Survey: The Prevalence and Properties of Galaxy-wide AGN-driven Outflows at z ∼ 2

Using observations from the first 2 yr of the MOSFIRE Deep Evolution Field (MOSDEF) survey, we study 13 active galactic nucleus (AGN) driven outflows detected from a sample of 67 X-ray, IR, and/or optically selected AGNs at z∼2. The AGNs have bolometric luminosities of ∼10{sup 44}--10{sup 46} erg s{sup −1}, including both quasars and moderate-luminosity AGNs. We detect blueshifted, ionized gas outflows in the Hβ, [O iii], Hα, and/or [N ii] emission lines of 19% of the AGNs, while only 1.8% of the MOSDEF galaxies have similarly detected outflows. The outflow velocities span ∼300 to 1000 km s{sup −1}. Eight of the 13 outflows are spatially extended on similar scales to the host galaxies, with spatial extents of 2.5–11.0 kpc. Outflows are detected uniformly across the star-forming main sequence, showing little trend with the host galaxy star formation rate. Line ratio diagnostics indicate that the outflowing gas is photoionized by the AGNs. We do not find evidence for positive AGN feedback, in either our small MOSDEF sample or a much larger Sloan Digital Sky Survey sample, using the BPT diagram. Given that a galaxy with an AGN is 10 times more likely to have a detected outflow, the outflowing gas is photoionized by the AGNs, and estimates of the mass and energy outflow rates indicate that stellar feedback is insufficient to drive at least some of these outflows; they are very likely to be AGN driven. The outflows have mass-loading factors of the order of unity, suggesting that they help regulate star formation in their host galaxies, though they may be insufficient to fully quench it.

79 ASTRONOMY AND ASTROPHYSICS↗

HST FOS spectroscopy of M87: Evidence for a disk of ionized gas around a massive black hole

Using the Faint Object Spectrograph (FOS) on the Hubble Space Telescope (HST) to observe the central region of M87, we have obtained spectra covering approximately 4600-6800 A at a spectral dispersion approximately 4.4 A per resolution element through the .26 sec diameter entrance aperture. One spectrum was obtained centered on the nucleus of M87 and two centered 0.25 sec off the nucleus at position angles of 21 deg and 201 deg, thus sampling the anticipated major axis of the disklike structure (described in a companion Letter) expected to lie approximately perpendicular to the axis of the M87 jet. Pointing errors for these observations are estimated to be less than 0.02 sec. Radial velocities of the ionized gas in the two positions 0.25 sec on either side of the nucleus are measured to be approx. equals +/- 500 km/s relative to the M87 systemic velocity. These observations plus emission-line spectra obtained at two additional locations near the nucleus show the ionized gas to be in Keplerian rotation about a mass M = (2.4 +/- 0.7) x 10(exp 9) solar mass within the inner 0.25 sec of M87. Our results provide strong evidence for the presence of a supermassive nuclear black hole in M87.

Harms, Richard J.↗

The Interaction of Positively-charged Ions with Nucleic Acid Systems

The successful development of extremely low background sample cells for x-ray scattering studies has enabled experiments designed to elucidate some of the fundamental physical interactions involved in macromolecular folding. Microfabrication techniques were used to fabricate low volume (50 micro-liter) sample cells with silicon nitride membranes (sub micron in thickness) as x-ray windows. Scientifically, these studies focus on the interaction of negatively charged nucleic acid systems, RNA and DNA, with their surrounding (positively charged) ion atmospheres. Understanding the structure of the ion atmosphere and its influence on the shape/conformation of the macromolecule will help reveal the underlying physical forces employed by nature in the self-assembly of these important molecules.

Pollack, Lois↗

Differences in soil biological activity by terrain types at the sub-field scale in central Iowa US

Soil microbial communities are structured by biogeochemical processes that occur at many different spatial scales, which makes soil sampling difficult. Because soil microbial communities are important in nutrient cycling and soil fertility, it is important to understand how microbial communities function within the heterogeneous soil landscape. In this study, a self-organizing map was used to determine whether landscape data can be used to characterize the distribution of microbial biomass and activity in order to provide an improved understanding of soil microbial community function. Points within a row crop field in south-central Iowa were clustered via a self-organizing map using six landscape properties into three separate landscape clusters. Twelve sampling locations per cluster were chosen for a total of 36 locations. After the soil samples were collected, the samples were then analysed for various metabolic indicators, such as nitrogen and carbon mineralization, extractable organic carbon, microbial biomass, etc. It was found that sampling locations located in the potholes and toe slope positions had significantly greater microbial biomass nitrogen and carbon, total carbon, total nitrogen and extractable organic carbon than the other two landscape position clusters, while locations located on the upslope did not differ significantly from the other landscape clusters. However, factors such as nitrate, ammonia, and nitrogen and carbon mineralization did not differ significantly across the landscape. Altogether, this research demonstrates the effectiveness of a terrain-based clustering method for guiding soil sampling of microbial communities.

54 ENVIRONMENTAL SCIENCES↗

Potential, velocity, and density fields from sparse and noisy redshift-distance samples - Method

A method for recovering the three-dimensional potential, velocity, and density fields from large-scale redshift-distance samples is described. Galaxies are taken as tracers of the velocity field, not of the mass. The density field and the initial conditions are calculated using an iterative procedure that applies the no-vorticity assumption at an initial time and uses the Zel'dovich approximation to relate initial and final positions of particles on a grid. The method is tested using a cosmological N-body simulation 'observed' at the positions of real galaxies in a redshift-distance sample, taking into account their distance measurement errors. Malmquist bias and other systematic and statistical errors are extensively explored using both analytical techniques and Monte Carlo simulations.

Dekel, Avishai↗

THE MOLECULAR PROPERTIES OF GALACTIC H II REGIONS

We derive the molecular properties for a sample of 301 Galactic H II regions including 123 ultra compact (UC), 105 compact, and 73 diffuse nebulae. We analyze all sources within the BU-FCRAO Galactic Ring Survey (GRS) of {sup 13}CO emission known to be H II regions based upon the presence of radio continuum and cm-wavelength radio recombination line emission. Unlike all previous large area coverage {sup 13}CO surveys, the GRS is fully sampled in angle and yet covers {approx}75 deg{sup 2} of the Inner Galaxy. The angular resolution of the GRS (46'') allows us to associate molecular gas with H II regions without ambiguity and to investigate the physical properties of this molecular gas. We find clear CO/H II morphological associations in position and velocity for {approx}80% of the nebular sample. Compact H II region molecular gas clouds are on average larger than UC clouds: 2.'2 compared to 1.'7. Compact and UC H II regions have very similar molecular properties, with {approx}5 K line intensities and {approx}4 km s{sup -1} line widths. The diffuse H II region molecular gas has lower line intensities, {approx}3 K, and smaller line widths, {approx}3.5 km s{sup -1}. These latter characteristics are similar to those found for quiescent molecular clouds in the GRS. Our sample nebulae thus show evidence for an evolutionary sequence wherein small, dense molecular gas clumps associated with UC H II regions grow into older compact nebulae and finally fragment and dissipate into large, diffuse nebulae.

79 ASTRONOMY AND ASTROPHYSICS↗

Simple Regulator For Positive-Pressure Glove Box

Weighted, inflated bag regulates pressure in positive-pressure glove box such as those used to manipulate samples in atmosphere isolated from such contaminations in open air as moisture or oxygen. Weight atop the inflated bag rises and falls as gas flows into and out of bag from glove box. Positive pressure relative to surroundings pushes gloves outward when not being used. To manipulate items in box, technician forces gloves inside. Sensitive materials manipulated in dry or inert atmosphere without danger of overpressure when technician inserts hands in gloves, or of underpressure - and inward leakage of air - when technician draws hands out of gloves. Replaces elaborate system of pressure-activated valves. Quieter, cheaper, and more reliable.

Shlichta, Paul J.↗

Development of an electrostatic positioner for space material processing

This paper describes an electrostatic positioning instrument which was developed at the Jet Propulsion Laboratory to enable experimenters to conduct containerless material science experiments in space. Samples that are to be studied are electrically charged and controlled by the electrostatic force produced by a set of properly arranged electrodes. Three different types of positioners are described, i.e., the dish type, the ring type, and the tetrahedral type. In all these systems, the positioning and the damping of the sample is accomplished by a feedback control system. The advantage of this electrostatic positioning method, in comparison to the other methods, such as acoustic and electromagnetic, lies in the fact that it can operate in a high vacuum and does not require the material to be electrically conductive as long as the material can carry a certain amount of charge.

Rhim, W. K.↗

CLEAR: The Gas-phase Metallicity Gradients of Star-forming Galaxies at 0.6<z<2.6

We report on the gas-phase metallicity gradients of a sample of 238 star-forming galaxies at 0.6 < z < 2.6, measured through deep near-infrared Hubble Space Telescope slitless spectroscopy. The observations include 12 orbit depth Hubble/WFC3 G102 grism spectra taken as a part of the CANDELS Lyα Emission at Reionization (CLEAR) survey, and archival WFC3 G102+G141 grism spectra overlapping the CLEAR footprint. The majority of galaxies in this sample are consistent with having a zero or slightly positive metallicity gradient ( dZ/dR ≥ 0, i.e., increasing with radius) across the full mass range probed (8.5 < log M * / M ⊙ < 10.5). We measure the intrinsic population scatter of the metallicity gradients, and show that it increases with decreasing stellar mass—consistent with previous reports in the literature, but confirmed here with a much larger sample. To understand the physical mechanisms governing this scatter, we search for correlations between the observed gradient and various stellar population properties at fixed mass. However, we find no evidence for a correlation with the galaxy properties we consider—including star formation rates, sizes, star formation rate surface densities, and star formation rates per gravitational potential energy. We use the observed weakness of these correlations to provide material constraints for predicted intrinsic correlations from theoretical models.

Raymond C. Simons↗

Open Specy 1.0: Automated (Hyper)spectroscopy for Microplastics

Microplastic spectral analysis is one of the most time-consuming processes in studying microplastic pollution, often requiring days per sample. Researchers are transitioning to automated batch and hyperspectral image analysis techniques to enhance efficiency. Open Specy, initially aimed at manual single-spectrum analysis, has now integrated automated methods. This updated version, Open Specy 1.0, introduces several new features, including two algorithms for automated processing (smoothing and particle compression), an extensive library containing over 40,000 open-source Raman and FTIR spectra, and two machine learning classifiers (logistic regression and k medoids) developed from this library. Furthermore, it includes a revamped user interface, an R package, and a benchmark data set for testing future advancements in automated techniques. Researchers evaluated various configurations for hyperspectral smoothing, particle identification, compression, and splitting, to achieve combined recovery rates between 50 and 150% particle counts, identities, and sizes with a coefficient of variation (CV) of less than 40% (the accredited standard). Mean absorbance times the standard deviation provided a consistent particle identification. Hyperspectral smoothing led to a 96% combined recovery rate and reduced variability (CV = 38%) compared to the 86% recovery (CV = 83%) of nonsmoothed controls. Additionally, compressing spectra for particles was significantly faster (>3x) and showed similar accuracy but with reduced variability than processing each pixel individually. Key challenges persist in automating spectral analysis, particularly in refining particle splitting algorithms, and improving identification routines to minimize false positives and negatives. In conclusion, new methods in sample preparation for better stabilization and dispersion of particles could overcome some of these issues.

13 HYDRO ENERGY↗

Use of Electronic Hand-held Devices for Collection of Savannah River Site Environmental Data - 13329

Savannah River Nuclear Solutions has begun using Xplore Tablet PC's to collect data in the field for soil samples, groundwater samples, air samples and round sheets at the Savannah River Site (SRS). EPA guidelines for groundwater sampling are incorporated into the application to ensure the sample technician follows the proper protocol. The sample technician is guided through the process for sampling and round sheet data collection by a series of menus and input boxes. Field measurements and well stabilization information are entered into the tablet for uploading into Environmental Restoration Data Management System (ERDMS). The process helps to eliminate input errors and provides data integrity. A soil sample technician has the ability to collect information about location of sample, field parameter, describe the soil sample, print bottle labels, and print chain of custody for the sample that they have collected. An air sample technician has the ability to provide flow, pressure, hours of operation, print bottle labels and chain of custody for samples they collect. Round sheets are collected using the information provided in the various procedures. The data are collected and uploaded into ERDMS. The equipment used is weather proof and hardened for the field use. Global Positioning System (GPS) capabilities are integrated into the applications to provide the location where samples were collected and to help sample technicians locate wells that are not visited often. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

MECHANISTIC UNDERSTANDING OF CAUSTIC CRACKING OF CARBON STEELS

Liquid waste generated by the PUREX process for separation of nuclear materials is concentrated and stored in Type IV single-shell carbon steel tanks at the Savannah River Site (SRS). The Type IV tanks for this waste do not have cooling coils and have not undergone heat treatment to stress-relieve the tanks. After the waste is concentrated by evaporation, it becomes very alkaline and can cause stress corrosion cracking (SCC) and pitting corrosion of the tank materials. SRS has experienced leakage from non-stress-relieved waste tanks constructed of A285 carbon steel and pitting of A212 carbon steel tanks in the vapor space. An investigation of tank materials has been undertaken at SRS to develop a basic understanding of caustic SCC of A285 and A212 grade carbon steels exposed to aqueous solutions, primarily containing sodium hydroxide (NaOH), sodium nitrate (NaNO{sub 3}), and sodium nitrite (NaNO{sub 2}) at temperatures relevant to the operating conditions of both the F and H area plants. This report presents the results of this corrosion testing program. Electrochemical tests were designed using unstressed coupons in a simulated tank environment. The purpose of this testing was to determine the corrosion susceptibility of the tank materials as a function of chemical concentration, pH, and temperature. A285 and A516 (simulates A212 carbon steel) coupons were used to investigate differences in the corrosion of these carbon steels. Electrochemical testing included measurement of the corrosion potential and polarization resistance as well as cyclic potentiodynamic polarization (CPP) testing of coupons. From the CPP experiments, corrosion characteristics were determined including: corrosion potential (E{sub corr}), pitting or breakdown potential (E{sub pit}), and repassivation potential (E{sub prot}). CPP results showed no indications of localized corrosion, such as pitting, and all samples showed the formation of a stable passive layer as evidenced by the positive hysteresis during the scan. Analysis of the CPP data was performed to compare the corrosion susceptibility of the samples under different environmental conditions. Test results indicated that the most important factors affecting corrosion of the steel are the solution temperature, hydroxide concentration, and the material used in constructing the tanks. Variables that did not significantly affect the corrosion susceptibility of the steel were the nitrate or nitrite concentration and the atmosphere in the tank. The passivation current of the coupons increased exponentially with temperature. Longer-term studies of the passivation current are suggested based on results from the literature for iron in highly caustic environments. Polarization resistance studies showed a significant increase in corrosion rate at 125 C and 12 M hydroxide concentration when compared with tests at lower temperatures and lower hydroxide concentrations. Within the temperature and pH range of these tests, iron oxide, Fe{sub 3}O{sub 4}, becomes unstable and could account for the increased corrosion susceptibility. The applicability of these conditions should be confirmed and detailed surface studies should be conducted to determine the corrosion resistance of A285 and A516 carbon steels under these conditions. Surface science studies should also be conducted to determine the role of the carbon steel composition in preventing corrosion under these conditions.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Up-regulation of CHAF1A, a poor prognostic factor, facilitates cell proliferation of colon cancer

Highlights: • We identified that CHAF1A was up-regulated in colon tumor mucosa in TMA. • The expression pattern of CHAF1A was validated with qPCR and western-blot. • CHAF1A overexpression is an independent indicator for poor colon cancer survival. • CHAF1A facilitates cell proliferation of colon cancer both in vitro and in vivo. - Abstract: Deregulation of chromatin assembly factor 1, p150 subunit A (CHAF1A) has recently been reported to be involved in the development of some cancer types. In this study, we identified that the frequency of positive CHAF1A staining in primary tumor mucosa (45.8%, 93 of 203 samples) was significantly elevated compared to that in paired normal mucosa (18.7%, 38 of 203 samples). The increased expression was strongly associated with cancer stage, tumor invasion, and histological grade. The five-year survival rate of patients with CHAF1A-positive tumors was remarkably lower than that of patients with CHAF1A-negative tumors. Colon cancer cells with CHAF1A knockdown exhibited decreased cell growth index, reduction in colony formation ability, elevated cell apoptosis rate as well as impaired colon tumorigenicity in nude mice. Hence, CHAF1A upregulation functions as a poor prognostic indicator of colon cancer, potentially contributing to its progression by mediating cancer cell proliferation.

60 APPLIED LIFE SCIENCES↗

Cyclable Variable Path Length Multilevel Structures for Lossless Ion Manipulations (SLIM) Platform for Enhanced Ion Mobility Separations

Ion mobility-mass spectrometry (IMS-MS) is increasingly used to analyze complex samples and provide structural information of unknown compounds. As the complexity of samples increases, there is a need to improve the resolution of IMS-MS instruments to increase the rate of molecular identification. In this work, we evaluated a cyclable and variable-pathlength multilevel Structures for Lossless Ion Manipulations (SLIM) platform to achieve a higher resolving power than previously possible. This new multilevel SLIM platform has eight separation levels connected by ion escalators and a path length of ~88 meters (~11 meters per level). Our new multilevel SLIM can also be operated in an ‘ion cycling’ mode where a set of return ion escalators transport ions from the eighth back to the first level, allowing even longer path lengths (and higher IMS resolution). The platform has been improved to enhance the ion transmission and IMS separation quality by reducing the spacing between SLIM boards as well as board thickness, reducing the ions’ escalator residence time. Compared to the previous generation, the new multilevel SLIM demonstrated a better transmission for a set of phosphazene ions, especially for the low-mobility ions. The new multilevel SLIM achieved better resolving powers than our previous 4-level SLIM. The collision cross-section-based resolving power of the SLIM platform was tested using a pair of singly-charged reverse sequence peptides (SDGRG 1+ , GRGDS 1+ ). We achieved 1100 resolving power using 88 meters of path length (i.e., 8 levels) and 1400 following an additional pass through the eight levels (i.e., 16 levels or 173.5 m). The multilevel SLIM was further evaluated to demonstrate the enhanced separation for a positively and negatively charged brain total lipid extract sample. Finally, the new multilevel SLIM enables much higher resolving powers for a wide range of ion mobilities, improved transmission for low-mobility ions, and the ability to perform even higher resolving power for ions of interest.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Establishing a process of irradiating small animal brain using a CyberKnife and a microCT scanner

Purpose: Establish and validate a process of accurately irradiating small animals using the CyberKnife G4 System (version 8.5) with treatment plans designed to irradiate a hemisphere of a mouse brain based on microCT scanner images. Methods: These experiments consisted of four parts: (1) building a mouse phantom for intensity modulated radiotherapy (IMRT) quality assurance (QA), (2) proving usability of a microCT for treatment planning, (3) fabricating a small animal positioning system for use with the CyberKnife's image guided radiotherapy (IGRT) system, and (4)in vivo verification of targeting accuracy. A set of solid water mouse phantoms was designed and fabricated, with radiochromic films (RCF) positioned in selected planes to measure delivered doses. After down-sampling for treatment planning compatibility, a CT image set of a phantom was imported into the CyberKnife treatment planning system—MultiPlan (ver. 3.5.2). A 0.5 cm diameter sphere was contoured within the phantom to represent a hemispherical section of a mouse brain. A nude mouse was scanned in an alpha cradle using a microCT scanner (cone-beam, 157 × 149 pixels slices, 0.2 mm longitudinal slice thickness). Based on the results of our positional accuracy study, a planning treatment volume (PTV) was created. A stereotactic body mold of the mouse was “printed” using a 3D printer laying UV curable acrylic plastic. Printer instructions were based on exported contours of the mouse's skin. Positional reproducibility in the mold was checked by measuring ten CT scans. To verify accurate dose delivery in vivo, six mice were irradiated in the mold with a 4 mm target contour and a 2 mm PTV margin to 3 Gy and sacrificed within 20 min to avoid DNA repair. The brain was sliced and stained for analysis. Results: For the IMRT QA using a set of phantoms, the planned dose (6 Gy to the calculation point) was compared to the delivered dose measured via film and analyzed using Gamma analysis (3% and 3 mm). A passing rate of 99% was measured in areas of above 40% of the prescription dose. The final inverse treatment plan was comprised of 43 beams ranging from 5 to 12.5 mm in diameter (2.5 mm size increments are available up to 15 mm in diameter collimation). Using the Xsight Spine Tracking module, the CyberKnife system could not reliably identify and track the tiny mouse spine; however, the CyberKnife system could identify and track the fiducial markers on the 3D mold.In vivo positional accuracy analysis using the 3D mold generated a mean error of 1.41 mm ± 0.73 mm when fiducial markers were used for position tracking. Analysis of the dissected brain confirmed the ability to target the correct brain volume. Conclusions: With the use of a stereotactic body mold with fiducial markers, microCT imaging, and resolution down-sampling, the CyberKnife system can successfully perform small-animal radiotherapy studies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

REPORT OF THE ISS OSI INVITED MEETING, VIENNA, 24-27 MARCH, 2009

The International Scientific Studies project (ISS) was initiated in early 2008 with the objective of creating a series of activities aimed at application of modern scientific methods to improve the efficiency of analysis and the quality of verification of the Comprehensive Nuclear Test-Ban Treaty Organization (CTBTO). The ISS On-Site Inspection (OSI) Invited Meeting convened on March 24, 2009 with the objectives of gaining a better understanding of the phenomenology of underground nuclear explosions (UNE) for OSI purposes and to identify areas of interest to OSI that could benefit significantly from contributions by the general scientific community. Fifteen invited experts from four countries, along with fifteen members of the OSI Division of the Provisional Technical Secretariat (PTS) met for four days at the Vienna International Center in an informal setting to discuss the application of observational methods, geophysical techniques, radionuclide measurement methods, environmental sampling methods, drilling techniques, and information management in the context UNE phenomena and OSI implementation. The meeting began with the identification and description of two general OSI scenarios, a vertical borehole emplacement and a horizontal tunnel emplacement, that serve as general examples of past UNE testing activities that can be used as a reference to identify UNE phenomena relevant for OSI observations. A significant portion of the first day of the meeting was spent in the description of the details of these scenarios and their implications for OSI observables. This discussion then served as a foundation for the discussions of the following three days in which OSI methods and technologies were evaluated in the context of UNE phenomenology and signatures. The methods and technologies discussed included visual observation from air and ground, radiation detection from the air, ground, and subsurface, ground-based and airborne geophysical observations and analysis, collection strategies for air, water, and solid samples, drilling concepts, and aspects of data fusion, information management, and modeling and simulation. The informal setting of the meeting provided a 'brainstorming' atmosphere and participation was excellent. One important aspect of this particular group was the very wide breadth of experience and expertise represented, ranging from those sharing their knowledge of UNE testing practice, radiological measurements and sampling, and knowledge of the underground effects of UNEs, to those with extensive experience in scientific and commercial geophysical measurements and surveys, to others with rich experience gained from several OSI field exercises, including the recent OSI Integrated Field Exercise in held in Kazakhstan in September 2008. During the workshop a number of topic areas relevant to OSI, explained in the list below, were identified that will benefit from collaboration with the international scientific community. Most of the topics represent the potential for studies of long-term interest, but some topics were identified that could be addressed, either by workshop participants or others known to the participants, that could be included as abstracts for submission to the ISS meeting taking place in June 2009. Items with topics that could be covered in the June meeting are annotated in the list. The meeting ended with the general understanding that ISS will not be completed with the June 2009 Conference. Rather, the ISS is considered as a long term project sponsoring relevant ongoing international scientific initiatives to expand and improve the verification capabilities of the Comprehensive Nuclear Test-Ban Treaty.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Volatiles in High-K Lunar Basalts

Chlorine is an unusual isotopic system, being essentially unfractionated ((delta)Cl-37 approximately 0 per mille ) between bulk terrestrial samples and chondritic meteorites and yet showing large variations in lunar (approximately -4 to +81 per mille), martian, and vestan (HED) samples. Among lunar samples, the volatile-bearing mineral apatite (Ca5(PO4)3[F,Cl,OH]) has been studied for volatiles in K-, REE-, and P (KREEP), very high potassium (VHK), low-Ti and high-Ti basalts, as well as samples from the lunar highlands. These studies revealed a positive correlation between in-situ (delta)Cl-37 measurements and bulk incompatible trace elements (ITEs) and ratios. Such trends were interpreted to originate from Cl isotopic fractionation during the degassing of metal chlorides during or shortly after the differentiation of the Moon via a magma ocean. In this study, we investigate the volatile inventories of a group of samples for which new-era volatile data have yet to be reported - the high-K (greater than 2000 ppm bulk K2O), high-Ti, trace element-rich mare basalts. We used isotope imaging on the Cameca NanoSIMS 50L at JSC to obtain the Cl isotopic composition [((Cl-37/(35)Clsample/C-37l/(35)Clstandard)-1)×1000, to get a value in per thousand (per mille)] which ranges from approximately -2.7 +/- 2 per mille to +16.1 +/- 2 per mille (2sigma), as well as volatile abundances (F & Cl) of apatite in samples 10017, 10024 & 10049. Simply following prior models, as lunar rocks with high bulk-rock abundances of ITEs we might expect the high-K, high-Ti basalts to contain apatite characterized by heavily fractionated (delta)Cl-37 values, i.e., Cl obtained from mixing between unfractionated mantle Cl (approximately 0 per mille) and the urKREEP reservoir (possibly fractionated to greater than +25 per mille.). However, the data obtained for the studied samples do not conform to either the early degassing or mixing models. Existing petrogentic models for the origin of the high-K, high-Ti basalts do not include urKREEP assimilation into their LMO cumulate sources. Therefore, Cl in these basalts either originated from source region heterogeneity or through assimilation or metasomatism by volatile and incompatible trace element rich materials. The new data presented here could provide evidence for the existence of region(s) in the lunar interior that are ITE-enriched and contain Cl that does not share isotopic affinities with lunar urKREEP, possibly representing the composition of the purported 'neuKREEP'.

Barnes, Jessica J.↗