Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Process Sample Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

Test Bed: Treatability of Hanford Tank Waste - 18501

In an effort to advance the Low Activity Waste Pretreatment System technology readiness level at the Hanford Site, the effectiveness of a critical technology element, sRF ion-exchange resin, was demonstrated in the selective removal of Cs-137 from 11.5 L of composited Hanford supernate tank waste. Prior to ion-exchange, solids filtration was performed on the tank waste composite. Between the time of filtrate collection and filtrate processing on the ion-exchange columns, additional solids had formed. These secondary solids resulted from the combination of supernates high in fluoride content with supernates high in phosphate content and the relatively short blend time. Samples were collected before, during and after the ion-exchange process for characterization of a full suite of constituents (inorganic, organic, and radionuclides) to aid in the classification of the cesium-removed waste for shipping, receiving, treatment, and disposal determinations. Following chemical analysis, the remaining 10.8 L (2.9 gal) of cesium-depleted waste was shipped to an off-site vendor for grout-encapsulation and eventual disposal at the Waste Control Specialists Federal Waste Disposal Facility in Andrews, Texas as low-level waste. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A joint analysis of Planck and BICEP2 B modes including dust polarization uncertainty

We analyze BICEP2 and Planck data using a model that includes CMB lensing, gravity waves, and polarized dust. Recently published Planck dust polarization maps have highlighted the difficulty of estimating the amount of dust polarization in low intensity regions, suggesting that the polarization fractions have considerable uncertainties and may be significantly higher than previous predictions. In this paper, we start by assuming nothing about the dust polarization except for the power spectrum shape, which we take to be C{sub l}{sup BB,dust} ∝ l{sup -2.42}. The resulting joint BICEP2+Planck analysis favors solutions without gravity waves, and the upper limit on the tensor-to-scalar ratio is r<0.11, a slight improvement relative to the Planck analysis alone which gives r<0.13 (95% c.l.). The estimated amplitude of the dust polarization power spectrum agrees with expectations for this field based on both HI column density and Planck polarization measurements at 353 GHz in the BICEP2 field. Including the latter constraint on the dust spectrum amplitude in our analysis improves the limit further to r < 0.09, placing strong constraints on theories of inflation (e.g., models with r>0.14 are excluded with 99.5% confidence). We address the cross-correlation analysis of BICEP2 at 150 GHz with BICEP1 at 100 GHz as a test of foreground contamination. We find that the null hypothesis of dust and lensing with 0r= gives Δ χ{sup 2} < 2 relative to the hypothesis of no dust, so the frequency analysis does not strongly favor either model over the other. We also discuss how more accurate dust polarization maps may improve our constraints. If the dust polarization is measured perfectly, the limit can reach r < 0.05 (or the corresponding detection significance if the observed dust signal plus the expected lensing signal is below the BICEP2 observations), but this degrades quickly to almost no improvement if the dust calibration error is 20% or larger or if the dust maps are not processed through the BICEP2 pipeline, inducing sampling variance noise.

79 ASTRONOMY AND ASTROPHYSICS↗

DNA Ploidy Measured on Archived Pretreatment Biopsy Material May Correlate With Prostate-Specific Antigen Recurrence After Prostate Brachytherapy

Purpose: To explore whether DNA ploidy of prostate cancer cells determined from archived transrectal ultrasound-guided biopsy specimens correlates with disease-free survival. Methods and Materials: Forty-seven failures and 47 controls were selected from 1006 consecutive low- and intermediate-risk patients treated with prostate {sup 125}I brachytherapy (July 1998-October 2003). Median follow-up was 7.5 years. Ten-year actuarial disease-free survival was 94.1%. Controls were matched using age, initial prostate-specific antigen level, clinical stage, Gleason score, use of hormone therapy, and follow-up (all P nonsignificant). Seventy-eight specimens were successfully processed; 27 control and 20 failure specimens contained more than 100 tumor cells were used for the final analysis. The Feulgen-Thionin stained cytology samples from archived paraffin blocks were used to determine the DNA ploidy of each tumor by measuring integrated optical densities. Results: The samples were divided into diploid and aneuploid tumors. Aneuploid tumors were found in 16 of 20 of the failures (80%) and 8 of 27 controls (30%). Diploid DNA patients had a significantly lower rate of disease recurrence (P=.0086) (hazard ratio [HR] 0.256). On multivariable analysis, patients with aneuploid tumors had a higher prostate-specific antigen failure rate (HR 5.13). Additionally, those with “excellent” dosimetry (V100 >90%; D90 >144 Gy) had a significantly lower recurrence rate (HR 0.25). All patients with aneuploid tumors and dosimetry classified as “nonexcellent” (V100 <90%; D90 <144 Gy) (5 of 5) had disease recurrence, compared with 40% of patients with aneuploid tumors and “excellent” dosimetry (8 of 15). In contrast, dosimetry did not affect the outcome for diploid patients. Conclusions: Using core biopsy material from archived paraffin blocks, DNA ploidy correctly classified the majority of failures and nonfailures in this study. The results suggest that DNA ploidy can be used as a useful marker for aggressiveness of localized prostate cancer. A larger study will be necessary to further confirm our hypothesis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Blind identification of full-field vibration modes of output-only structures from uniformly-sampled, possibly temporally-aliased (sub-Nyquist), video measurements

Enhancing the spatial and temporal resolution of vibration measurements and modal analysis could significantly benefit dynamic modelling, analysis, and health monitoring of structures. For example, spatially high-density mode shapes are critical for accurate vibration-based damage localization. In experimental or operational modal analysis, higher (frequency) modes, which may be outside the frequency range of the measurement, contain local structural features that can improve damage localization as well as the construction and updating of the modal-based dynamic model of the structure. In general, the resolution of vibration measurements can be increased by enhanced hardware. Traditional vibration measurement sensors such as accelerometers have high-frequency sampling capacity; however, they are discrete point-wise sensors only providing sparse, low spatial sensing resolution measurements, while dense deployment to achieve high spatial resolution is expensive and results in the mass-loading effect and modification of structure's surface. Non-contact measurement methods such as scanning laser vibrometers provide high spatial and temporal resolution sensing capacity; however, they make measurements sequentially that requires considerable acquisition time. As an alternative non-contact method, digital video cameras are relatively low-cost, agile, and provide high spatial resolution, simultaneous, measurements. Combined with vision based algorithms (e.g., image correlation or template matching, optical flow, etc.), video camera based measurements have been successfully used for experimental and operational vibration measurement and subsequent modal analysis. However, the sampling frequency of most affordable digital cameras is limited to 30–60 Hz, while high-speed cameras for higher frequency vibration measurements are extremely costly. This work develops a computational algorithm capable of performing vibration measurement at a uniform sampling frequency lower than what is required by the Shannon-Nyquist sampling theorem for output-only modal analysis. In particular, the spatio-temporal uncoupling property of the modal expansion of structural vibration responses enables a direct modal decoupling of the temporally-aliased vibration measurements by existing output-only modal analysis methods, yielding (full-field) mode shapes estimation directly. Then the signal aliasing properties in modal analysis is exploited to estimate the modal frequencies and damping ratios. Furthermore, the proposed method is validated by laboratory experiments where output-only modal identification is conducted on temporally-aliased acceleration responses and particularly the temporally-aliased video measurements of bench-scale structures, including a three-story building structure and a cantilever beam.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Surface characterization of InP trenches embedded in oxide using scanning probe microscopy

Metrology for structural and electrical analyses at device level has been identified as one of the major challenges to be resolved for the sub-14 nm technology nodes. In these advanced nodes, new high mobility semiconductors, such as III–V compounds, are grown in narrow trenches on a Si substrate. Probing the nature of the defects, the defect density, and the role of processing steps on the surface of such structures are prime metrology requirements. In order to enable defect analysis on a (III–V) surface, a proper sample preparation for oxide removal is of primary importance. In this work, the effectiveness of different chemical cleanings and thermal annealing procedures is investigated on both blanket InP and oxide embedded InP trenches by means of scanning probe microscopy techniques. It is found that the most effective approach is a combination of an HCl-based chemical cleaning combined with a low-temperature thermal annealing leading to an oxide free surface with atomically flat areas. Scanning tunneling microscopy (STM) has been the preferred method for such investigations on blanket films due to its intrinsic sub-nm spatial resolution. However, its application on oxide embedded structures is non-trivial. To perform STM on the trenches of interest (generally <20 nm wide), we propose a combination of non-contact atomic force microscopy and STM using the same conductive atomic force microscopy tip Our results prove that with these procedures, it is possible to perform STM in narrow InP trenches showing stacking faults and surface reconstruction. Significant differences in terms of roughness and terrace formation are also observed between the blanket and the oxide embedded InP.

36 MATERIALS SCIENCE↗

Partial wave analysis of 𝑒 + ⁢𝑒 − → 𝜋 + ⁢𝜋 − ⁢𝐽/𝜓 and cross section measurement of 𝑒 + ⁢𝑒 − → 𝜋 ± ⁢𝑍 𝑐 ⁢(3900) ∓ from 4.1271 to 4.3583 GeV

Based on 12.0 fb −1 of 𝑒 + ⁢𝑒 − collision data samples collected by the BESIII detector at center-of-mass energies from 4.1271 to 4.3583 GeV, a partial wave analysis is performed for the process 𝑒 + ⁢𝑒 − → 𝜋 + ⁢𝜋 − ⁢𝐽/𝜓. The cross sections for the subprocesses 𝑒 + ⁢𝑒 − → 𝜋 + ⁢𝑍 𝑐 ⁢(3900) − + c.c. → 𝜋 + ⁢𝜋 − ⁢𝐽/𝜓, 𝑓 0 ⁡(980)⁢(→ 𝜋 + ⁢𝜋 − )⁢𝐽/𝜓, and (𝜋 + ⁢𝜋 − ) S−wave⁢ 𝐽/𝜓 are measured for the first time. The mass and width of the 𝑍 𝑐 ⁢(3900) ± are determined to be 3884.6 ± 0.7 ± 3.3 MeV/𝑐 2 and 37.2 ± 1.3 ± 6.6 MeV, respectively. The first errors are statistical and the second systematic. The final state (𝜋 + ⁢𝜋 − ) S−wave ⁢𝐽/𝜓 dominates the process 𝑒 + ⁢𝑒 − → 𝜋 + ⁢𝜋 − ⁢𝐽/𝜓. By analyzing the cross sections of 𝜋 ±⁢ 𝑍 𝑐 ⁢(3900) ∓ and 𝑓 0 ⁡(980)⁢𝐽/𝜓, 𝑌⁡(4220) has been observed. Its mass and width are determined to be 4225.7 ± 4.1 ± 3.4 MeV/𝑐 2 and 57.5 ± 9.4 ± 12.1 MeV, respectively.

lepton colliders↗

Practical Considerations of Moisture in Baled Biomass Feedstocks

Agricultural residues make up a large portion of the immediately available biomass feedstock for renewable energy markets. Current collection and storage methods rely on existing feed and forage practices designed to preserve nutrients and properties of digestibility. Low-cost collection and storage practices that preserve carbohydrates across a range of inbound moisture contents are needed to assure the economic and technical success of the emerging biomass industry. This study examines the movement of moisture in storage and identifies patterns of migration resulting from several on-farm storage systems and their impacts on moisture measurement and dry matter recovery. Baled corn stover and energy sorghum were stored outdoors in uncovered, tarp-covered, or wrapped stacks and sampled periodically to measure moisture and dry matter losses. Interpolation between discrete sampling locations in the stack improved bulk moisture content estimates and showed clear patterns of accumulation and re-deposition. Atmospheric exposure, orientation, and contact with barriers (i.e., soil, tarp, and wrap surfaces) were found to cause the greatest amount of moisture heterogeneity within stacks. Although the bulk moisture content of many stacks remained in the range suitable for aerobic stability, regions of high moisture were sufficient to support microbial activity, thus support dry matter loss. Stack configuration, orientation, and coverage methods are discussed relative to impact on moisture management and dry matter preservation. Additionally, sample collection and data analysis are discussed relative to assessment at the biorefinery as it pertains to stability in storage, queuing, and moisture carried into processing.

09 BIOMASS FUELS↗

Simulation of Thematic Mapper performance as a function of sensor scanning parameters

The investigation and results of the Thematic Mapper Instrument Performance Study are described. The Thematic Mapper is the advanced multispectral scanner initially planned for the Earth Observation Satellite and now planned for LANDSAT D. The use of existing digital airborne scanner data obtained with the Modular Multispectral Scanner (M2S) at Bendix provided an opportunity to simulate the effects of variation of design parameters of the Thematic Mapper. Analysis and processing of this data on the Bendix Multispectral Data Analysis System were used to empirically determine categorization performance on data generated with variations of the sampling period and scan overlap parameters of the Thematic Mapper. The Bendix M2S data, with a 2.5 milliradian instantaneous field of view and a spatial resolution (pixel size) of 10-m from 13,000 ft altitude, allowed a direct simulation of Thematic Mapper data with a 30-m resolution. The flight data chosen were obtained on 30 June 1973 over agricultural test sites in Indiana.

Johnson, R. H.↗

Automated chromosome analysis

Minicomputer-controlled system automatically prepares and analyses blood samples and displays karyotype in pictorial form as primary output. System accuracy is assured by operator interaction at key points during process. System can process up to 576 specimens per day.

Castleman, K. R.↗

A volatile organics concentrator for use in monitoring Space Station water quality

The process used to identify, select, and design an approach to the isolation and concentration of volatile organic compounds from a water sample prior to chemical analysis in a microgravity environment is discerned. The trade analysis leading to the recommended volatile organics concentrator (VOC) concept to be tested in a breadboard device is presented. The system covers the areas of gases, volatile separation from water, and water removal/gas chromatograph/mass spectrometer interface. Five options for potential use in the VOC and GC/MS system are identified and ranked, and also nine options are presented for separation of volatiles from the water phase. Seven options for use in the water removal/GC column and MS interface are also identified and included in the overall considerations. A final overall recommendation for breadboard VOC testing is given.

Ehntholt, Daniel J.↗

Compositional analysis of projectile residues on LDEF instrument AO187-1

Impact craters greater than 30 microns and associated projectile residues were analyzed by Scanning Electron Microscopy (SEM) and Energy Dispersive X-ray Analysis (EDXA). Objectives were to analyze a statistically significant number of projectiles to evaluate their chemical variability and possible clustering into discrete particle types. Bay A11 exposed six collector surfaces of anodized 1100-T4 (greater than 99 percent pure) aluminum sheets, 0.32 cm thick, yielding an exposed surface area of 1.1 sq. m. Four of the six panels have been retained at JSC, and were optically scanned, one (A11E00E) was prepared for SEM/EDX analysis. Bay A03 was occupied by high purity (99.99 percent) gold sheets, 0.5 mm thick, yielding an exposed surface area of 0.85 sq. m. Sample processing included the optical scanning (6X), labeling, and dislodging (by a punch-die device) of each individual impact greater than 75 microns for the aluminum and 30 microns for the gold. The 209 craters were dislodged form A11E00E, having crater diameters up to 3500 microns. Optical examination of the gold surfaces detected 238 craters, 198 of which were retained at JSC and analyzed via SEM/EDX. The analytical procedures included maximizing the geometric efficiency (take-off angles), using relatively long count times (500-1000 sec) and sufficiently high accelerating currents (25-30Kev). Despite diligent examination, a large number of craters did not exhibit measurable signals above background. Detectable resides were classified as either micrometeoritic or as man-made debris.

Bernhard, Ronald P.↗

Fixture For Sampling Volatile Materials In Containers

Fixture based on T-connector enables mass-spectrometric analysis of volatile contents of cylindrical containers without exposing contents to ambient conditions. Used to sample volatile contents of pressurized containers, contents of such enclosed processing systems as gas-phase reactors, gases in automotive emission systems, and gas in hostile environments.

Melton, Donald↗

BOREAS TE-5 Diurnal CO2 Canopy Profile Data

The BOREAS TE-5 team collected several data sets to investigate the vegetation-atmosphere CO2 and H2O exchange processes. These data were collected to provide detailed information within the canopy during times when TE-05 sampled canopy CO2 for carbon and oxygen isotope analysis. These measurements were made in both the NSA and SSA at the OJP, OBS, UBS, and OA sites from 25-May1994 to 08-Sep1994. CO2 profile data were not collected at SSA-OA during the first IFC. The data are available in tabular ASCII files. The data files are available on a CD-ROM (see document number 20010000884), or from the Oak Ridge National Laboratory (ORNL) Distributed Activity Archive Center (DAAC).

Hall, Forrest G.↗

Insight into Primordial Solar System Oxygen Reservoirs from Returned Cometary Samples

The recent successful rendezvous of the Stardust spacecraft with comet Wild-2 will be followed by its return of cometary dust to Earth in January 2006. Results from two separate dust impact detectors suggest that the spacecraft collected approximately the nominal fluence of at least 1,000 particles larger than 15 micrometers in size. While constituting only about one microgram total, these samples will be sufficient to answer many outstanding questions about the nature of cometary materials. More than two decades of laboratory studies of stratospherically collected interplanetary dust particles (IDPs) of similar size have established the necessary microparticle handling and analytical techniques necessary to study them. It is likely that some IDPs are in fact derived from comets, although complex orbital histories of individual particles have made these assignments difficult to prove. Analysis of bona fide cometary samples will be essential for answering some fundamental outstanding questions in cosmochemistry, such as (1) the proportion of interstellar and processed materials that comprise comets and (2) whether the Solar System had a O-16-rich reservoir. Abundant silicate stardust grains have recently been discovered in anhydrous IDPs, in far greater abundances (200 5,500 ppm) than those in meteorites (25 ppm). Insight into the more subtle O isotopic variations among chondrites and refractory phases will require significantly higher precision isotopic measurements on micrometer-sized samples than are currently available.

Brownlee, D. E.↗

Tracking of cells with a compact microscope imaging system with intelligent controls

A Microscope Imaging System (CMIS) with intelligent controls is disclosed that provides techniques for scanning, identifying, detecting and tracking microscopic changes in selected characteristics or features of various surfaces including, but not limited to, cells, spheres, and manufactured products subject to difficult-to-see imperfections. The practice of the present invention provides applications that include colloidal hard spheres experiments, biological cell detection for patch clamping, cell movement and tracking, as well as defect identification in products, such as semiconductor devices, where surface damage can be significant, but difficult to detect. The CMIS system is a machine vision system, which combines intelligent image processing with remote control capabilities and provides the ability to auto-focus on a microscope sample, automatically scan an image, and perform machine vision analysis on multiple samples simultaneously.

McDowell, Mark↗

Effect of the Presence of Chlorates and Perchlorates on the Pyrolysis of Organic Compounds: Implications for Measurements Done with the SAM Experiment Onboard the Curiosity Rover

The Mars Science Laboratory (MSL) Curiosity Rover carries a suite of instruments, one of which is the Sample Analysis at Mars (SAM) experiment. SAM is devoted to the in situ molecular analysis of gases evolving from solid samples collected by Curiosity on Mars surface/sub-surface. Among its three analytical devices, SAM has a gaschromatograph coupled to a quadrupole mass spectrometer (GC-QMS). The GC-QMS is devoted to the separation and identification of organic and inorganic material. Before proceeding to the GC-QMS analysis, the solid sample collected by Curiosity is subjected to a thermal treatment thanks to the pyrolysis oven to release the volatiles into the gas processing system. Depending on the sample, a derivatization method by wet chemistry: MTBSTFA of TMAH can also be applied to analyze the most refractory compounds. The GC is able to separate the organic molecules which are then detected and identified by the QMS (Figure 1). For the second time after the Viking landers in 1976, SAM detected chlorinated organic compounds with the pyrolysis GC-QMS experiment. The detection of perchlorates salts (ClO4-) in soil at the Phoenix Landing site suggests that the chlorohydrocarbons detected could come from the reaction of organics with oxychlorines. Indeed, laboratory pyrolysis experiments have demonstrated that oxychlorines decomposed into molecular oxygen and volatile chlorine (HCl and/or Cl2) when heated which then react with the organic matter in the solid samples by oxidation and/or chlorination processes.

Millan, M.↗

The Oxidation State of Sulfur in Apollo Samples 71035 and 71055

Lunar apatites contain 100s-1000s ppm sulfur [1-3]. This was initially puzzling because lunar basalts are thought to form, including at the time of apatite crystallization, in low oxygen fugacity (fO2) conditions where sulfur exists in its reduced form (S2-), a substitution not previously observed in natural apatite. It has been recently shown, using S-XANES measurements of the oxidation state of sulfur in apatites and proximal mesostasis in the lunar basalts 12039 and 10044, that sulfur is indeed present as S2- in both the mesostasis glass and apatite when measurements were performed far from cracks or pits in the thin section [4]. This observation is consistent with other mineralogical indications of the low fO2 during formation of these samples (~IW-1) such as the presence of Fe-metal, ulvöspinel, ilmenite, fayalite, and silica in the thin sections. In the same study, in addition to clear spectral evidence for the dominance of S2-, analyses of apatite grains in both samples that occurred near cracks or pits in the thin section sometimes revealed non-negligible spectral evidence (e.g., S6+/ΣS > 0.03; [4]) for the presence of S6+. Because S6+ was not observed in the mesostasis glass near the apatite grains measured, or in any phase far from cracks or pits in the studied thin sections, this S6+ was interpreted as either primary S2- in the sulfide altered to S6+ in the thin section, or S6+ of secondary origin, deposited in the fractures of the samples [4, 5]. Whether this is of lunar or terrestrial origin is unknown but has implications for lunar petrogenesis if lunar [e.g., 5], or sample handling and curation if terrestrial. To test between lunar and terrestrial origins for observed S6+ in Apollo-era thin sections, we will measure the oxidation state of sulfur in apatite and associated phases in a specially frozen sample from a boulder sampled at Station 1A during the Apollo 17 mission as part of the NASA Apollo Next Generation Sample Analysis (ANGSA) program. Here, we present “control” measurements of samples 71035 and 71055, using Apollo era thin sections of aliquots of these rocks that were processed upon return to Earth and since stored under N2 atmospheres at room temperature. These will be compared to measurements using newly made thin sections of aliquots of the same rocks (71035 and 71055). In addition, 71036, which has been in cold storage (-20℃) since the return of the Apollo 17 mission to Earth, has been recently made available through the ANGSA program. With 71036 we can test the effect of storage temperature on potential oxidation of S2- to S6+ in the relatively oxidizing and warm conditions of Earth’s surface.

apollo↗