Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Power grid”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

Biochemical Conversion of Herbaceous Biomass to Renewable Diesel: Net Greenhouse Gas and Air Pollutant Trade-offs

This study examines greenhouse gas (GHG) and criteria air pollutant (CAP) emissions trade-offs for renewable diesel across 12 scenarios, involving different biochemical conversion designs, biorefinery scales, and feedstocks. A conventional design uses lignin for on-site heat and power, which exports excess power to the grid. An alternative design exports lignin pellets, offsetting other pellet production methods but requiring grid electricity to meet biorefinery power demands. Net emissions were quantified in Iowa and Georgia, selected considering feedstock availability, coproduct displacement, and regional power grids, assuming grid-exported power avoids coal or low-carbon electricity. Results for the conventional design remained consistent across the electricity displacement scenarios. When comparing lignin utilization strategies, pelletizing lignin reduces sulfur dioxide, carbon monoxide, nitrogen oxides, and volatile organic compounds (net emissions –0.66 mg MJ –1 , 25 mg MJ –1 , 25 mg MJ –1 , 7.8 mg MJ –1 , respectively). However, lignin pelletization increases net particulate matter (fine and coarse) and ammonia (net emissions of 4.7 mg MJ –1 , 13 mg MJ –1 , and 0.26 mg MJ –1 , respectively), alongside indirect GHG emissions due to grid electricity dependence. Additionally, processing 2000 tonnes corn stover daily minimizes emissions for both designs. Only lignin pelletization with renewable electricity and additional particulate matter and ammonia controls reduces all CAP and GHG emissions simultaneously.

09 BIOMASS FUELS↗

Cyber-Power Co-Simulation for End-to-End Synchrophasor Network Analysis and Applications

The resiliency, reliability and security of the next generation cyber-power smart grid depend upon efficiently leveraging advanced communication and computing technologies. Also, developing real-time data-driven applications is critical to enable wide-area monitoring and control of the cyber-power grid given high-resolution data from Phasor Measurement Units (PMUs). North American Synchrophasor Initiative Network (NASPlnet) provides guidance for PMU data exchanges. With the advancement in networking and grid operation, it is necessary to evaluate the performance of different data flow architectures suggested by NASPInet and analyze the impact on applications. Therefore, we need a cyber-power co-simulation framework that supports very large-scale co-simulation capable of running in parallel, high-performance computing platforms and capturing real-life network behavior. This work presents an end-to-end automated and user-driven cyber-power co-simulation using NS3 to model communication networks, GridPACK to model the power grid, and HELICS as a co-simulation engine. Comparative analysis of latency in synchrophasor networks and a performance evaluation of a power system stabilizer application utilizing PMU data in an IEEE 39 bus test system is presented using this cosimulation testbed.

Mustafa, Hussain M.↗

Interactive Power to Frequency Dynamics Between Grid-Forming Inverters and Synchronous Generators in Power Electronics-Dominated Power Systems

With increased attention on grid-forming inverters as a power system stabilizing device during high shares of inverter-based resource operations, there is a present need for a transparent and methodical investigation of the inverted and direct power to frequency control capabilities and impacts of these devices on emerging power systems. Here, analysis of the frequency dynamics of the droop-controlled grid-forming inverter and the synchronous generator illuminates the inverted active power-frequency relationship and the frequency response order reduction, forming the basis for novel, nonlinear frequency control approaches. Device-level electromagnetic transient domain simulations corroborate the order-reduction findings, establish that a properly designed dc-side system has a negligible impact on power transfer and will not impede frequency regulation, and confirm the primary frequency response improvement with nonlinear control. Simulations of the 9- and 39-bus test systems validate the order reduction and associated decoupling of the nadir and rate of change of frequency in larger networks. Oscillatory mode analysis confirms the grid-forming benefit of increased damping; decreased damping is observed at shares above 80%, but not at 100%. Finally, simulations on a validated Maui power system model with a 96% of inverter-based resources model yield a trend toward a first-order response.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Power Electronics for Electrolyzer Applications to Enable Grid Services

The Power Electronics for Electrolyzer Applications to Enable Grid Services project aims to develop smart converter for dedicated electrolyzer applications to enable grid services via standardization of control interfaces between hydrogen electrolyzer system low-level controls and power converter controls. The project provides additional revenue source for electrolyzer through participation in grid services and reduces the cost of deployment and controls integration through standardization and risk due to supply-chain issues. It also enables the adoption of green hydrogen via standardizing the integration of energy storage, renewables, and distributed energy resources. Furthermore, the work provides a controlled validation environment to evaluate scalable integration solution for hydrogen production technologies, improves overall reliability and maintainability of the electrolyzer system for grid applications, and directly contributes to DOE HFTO's "Hydrogen Shot" goal.

energy transitions↗

Harmonics and Stability Evaluation of Converter-Interfaced Combined Heat and Power Units

Grid integration of medium-sized combined heat and power (CHP) units is challenging due to strict grid codes and conventional generators lack of control flexibility to meet these grid codes. Adding a two-stage ac-dc-ac power electronics interface between the generator and the utility grid will accelerate the interconnection process of CHP units. For the dc-ac stage, a voltage source converter (VSC) has been widely used as a grid-tied inverter because of its fast control and low total harmonics distortion (THD). In this paper, several topologies of generator-side rectifiers for ac-dc power conversion are explored and analyzed. The harmonics impact of various rectifiers on the CHP generator are evaluated. The overall cost of the electrical system, when using various types of rectifiers, is assessed and the VSC back-to-back converter interface configuration is found to be optimal. The overall system stability is also examined using small-signal impedance analysis to assess potential instability issues at the system level.

CHP, Harmonics, Generator Rectifier Unit, DC Imped↗

Multi-modular power plant with dedicated electrical grid

A multi-modular power plant includes a plurality of on-site nuclear power modules that generate a power plant output, and a number of power plant systems which operate using electricity associated with a house load of the power plant. A switchyard associated with the power plant may electrically connect the power plant to a distributed electrical grid. The distributed electrical grid may be configured to service a plurality of geographically distributed consumers. Additionally, the switchyard may electrically connect the power plant to a dedicated electrical grid. The dedicated electrical grid may provide electricity generated from the power plant output to a dedicated service load, and the power plant output may be equal to or greater than a combined load of the dedicated service load and the house load. At least a portion of the power plant output may be distributed to both the power plant systems and the dedicated electrical grid.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Vulnerability Assessments for Power-Electronics-Based Smart Grids

Here, in this paper, a novel method is proposed to evaluate the cyber security of the power-electronics-based smart grids (PESG). The proposed method considers the performance and stability of both the individual inverter and the grid. To our knowledge, this is a first attempt to evaluate the performance and stability of PESG due to cyber attacks. We first develop impedance-based modeling and cyber-attack modeling for PESG. Then we propose innovative two security criteria to evaluate the security of PESG, including stability-based and metrics-based. For metrics-based criteria, we propose to use both total harmonic distortion (THD) and space phasor model (SPM) to evaluate the inverter performance. The simulation results with a two-inverter-based power grid verify the validity and accuracy of the proposed security evaluation method. Results have shown that the performance and stability of PESG are significantly affected by cyber attacks, and thus there is indeed a need to further study cyber security issues of PESG.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Enhancing the Survivability of Power Systems With Grid-Edge DERs Against DoS Attacks

Power system survivability, defined as the ability of a system to maintain steady-state functionality under varying operational conditions, reflects its resilience against disturbances. While existing research primarily focuses on physical-layer disturbances, the increasing prevalence of grid-edge DERs, which are primarily used for integrating renewable energy, has significantly expanded the cyber attack surface. As a result, operational disruptions caused by cyber threats are posing significant challenges to system survivability and cannot be overlooked. To fill this gap, we redefine system survivability to incorporate the cyber layer’s status and propose a Distributionally Robust Optimization (DRO) approach to enhance power system survivability against potential cyber-physical threats. In this paper, we first analyze the operational guidelines of systems with a high penetration of DERs under various cyber network conditions and redefine survivability in this context. Next, we focus on the most common cyber threat, Denial-of-Service (DoS) attacks, and develop a corresponding attack model. This model allows for the creation of a kernel-based ambiguity set that captures attack uncertainties using historical data. Finally, we transform the proposed DRO model as a tractable optimization problem, with its solution providing an optimal cyber redundancy plan to enhance system survivability in DoS attack scenarios. Simulation results on the IEEE 13-node and 123-node test feeders demonstrate the effectiveness of our proposed model in improving system survivability. This model can also be expanded to include other types of common attacks and serve as a comprehensive planning tool to improve overall cyber physical survival of the system.

cybersecurity↗

Cross-Layered Cyber-Physical Power System State Estimation towards a Secure Grid Operation

In the Smart Grid paradigm, this critical infrastructure operation is increasingly exposed to cyber-threats due to the increased dependency on communication networks. An adversary can launch an attack on a power grid operation through False Data Injection into system measurements and/or through attacks on the communication network, such as flooding the communication channels with unnecessary data or intercepting messages. A cross-layered strategy that combines power grid data, communication grid monitoring and Machine Learning based processing is a promising solution for detecting cyberthreats. In this paper, an implementation of an integrated solution of a cross-layer framework is presented. The advantage of such a framework is the augmentation of valuable data that enhances the detection of anomalies in the operation of power grid. IEEE 118-bus system is built in Simulink to provide a power grid testing environment and communication network data is emulated using SimComponents. The performance of the framework is investigated under various FDI and communication attacks.

cyber security, network security, cyber-physical s↗

Medium-Duty Delivery Truck Integrated Bidirectional Wireless Power Transfer System With Grid and Stationary Energy Storage System Connectivity

Electric vehicles (EVs) can provide power to the grid or buildings similar to distributed energy resources (DER) for energy balancing applications or optimizing the operation of the microgrids in harmony with the other DER assets. This article presents the operating modes of a bidirectional wireless power transfer (WPT) system designed for a medium-duty package delivery vehicle. The WPT system designed for this study can transfer 20 kW of power across 11 in of air gap using custom-designed double-D (DD) couplers with LCC–LCC tuning networks. The proposed system utilizes a 480-V three-phase grid connection, a plug-in hybrid delivery truck with bidirectional WPT, and a stationary energy storage system (SESS) that can be connected to the primary-side dc link. Due to the differences in primary and secondary dc bus voltages, and considering the voltage of the SESS, asymmetric voltage gains were used in the system. Sensitivity analyses of this system with respect to these voltage levels are presented. Five different operating modes of the grid, SESS, and the EV battery are investigated with experimental results. Control algorithms are described for grid-to-vehicle (G2V) and vehicle-to-grid (V2G) operating modes. A bidirectional WPT system is operated with a power factor of 0.99 on the grid side in every operating mode. The EV battery was charged with 20.3 kW with an overall efficiency of 93.02% in the G2V operating mode. Finally, in the V2G operating mode, the WPT system provided 12.82 kW of power back to the grid with an overall efficiency of 89.08%.

25 ENERGY STORAGE↗

A Hybrid Fuel Cell and Battery Storage Power Management for Grid-Interactive EV Charging Station

With the increasing adoption of renewable energy sources in grid-interactive Electric Vehicle (EV) charging stations, the role of energy storage systems has become critical. While large energy storage systems have mitigated the intermittency of renewable energy, integrating multi-source energy management with prioritized charging can further enhance the reliability of charging stations (CS). This paper presents a decentralized energy management (DEM) approach combining battery energy storage (BES) and fuel cell (FC) systems using a rule-based line resistance correction droop (LRCD) control technique. The proposed droop control dynamically adjusts the gain to balance the state-of-charge (SoC) of the BES, enhancing power support longevity and improving battery life under varying capacity conditions by reducing current stress. Additionally, the paper addresses the challenges of using fuel cells in linear regions to optimize efficiency and manage various charging scenarios. The CS integrates unity power factor grid interaction, and power support for auxiliary loads, maintaining harmonic distortion within 5% during grid islanding. The approach evaluates DC bus voltage regulation under various scenarios of PV array power fluctuations and dynamic load variations, in both grid-connected and standalone operations. In conclusion, the proposed control strategy is validated on a laboratory prototype through various dynamic load variation and grid islanding scenarios.

Khalid, Mohd [Oak Ridge National Laboratory (ORNL)↗

Controllers for Distributed Grid Support for Power Systems using Hybrid DER plants with Electrolyzers [SWR-20-06]

This software presents the design and control for a hybrid DER site with integrated dispatchable electrolyzers. It is a comprehensive solution for regulating the dispatch of electrolyzer demand to support the grid using the respective control functions. Multiple control functions (ramp control, frequency support control, dispatch prioritization) are developed to integrate the proposed site for multiple services around load, voltage and frequency control. This allows the site owners to participate in both distribution and bulk system energy markets for grid ancillary services.

Jain, Rishabh↗

Control Design and EMT Simulation Toward the Restoration of Faulted Wind-Dominant Grids

Present power engineers have been challenged to employ electromagnetic transient (EMT) simulations to study the restoration of wind-dominant grids. This paper addresses this hurdle by developing strategies to: (i) reliably control the dc-link voltage of grid-forming wind turbines with dc-coupled batteries, (ii) tune controllers to stably interconnect wind power plants into a grid under recovery, and (iii) autonomously make restoration decisions if transmission faults occur during restoration. These contributions are assessed via EMT simulations of wind-dominant versions of the WSCC 9-bus grid and a 22-bus power system. Furthermore, this paper is significant to address recommendations by the North American Electric Reliability Corporation.

17 WIND ENERGY↗

Medium-Voltage Testbed for Comparing Advanced Power Line Sensors vs. Measurement Transformers with Electrical Grid Events

Electrical utilities have relied upon potential transformers (PTs) and current transformers (CTs) for very accurate metering and to provide reliable signals for protective relays. Less expensive alternative sensing technologies offer the possibility of wider deployment, particularly in grids that employ distributed energy resources. In this work, the performance of an advanced medi-um-voltage sensor is compared with a reference PT and CT and experimentally evaluated for different power grid scenarios on an advanced outdoor power line sensor testbed at the US De-partment of Energy’s Oak Ridge National Laboratory. The sensor is based on a capacitive divider for voltage monitoring and a Rogowski coil with integrator for current monitoring. The advanced outdoor power line sensor testbed has a real-time simulator that was used to generate transient scenarios (e.g., electrical faults, capacitor bank operation, service restoration), while the analog signals were recorded by the same high resolution power meter. The behavior of analog signals, harmonic components, total harmonic distortion, and crest factors were assessed for this power line sensor compared with the reference PT/CT, because of the absence for testing standards for advanced outdoor power line sensors.

Piesciorovsky, Emilio↗

NPP Simulators for Coupled Thermal and Electric Power Dispatch

The Light Water Reactor Sustainability (LWRS) program within the United States Department of Energy supports extending the operation of the U.S. commercial nuclear power plant (NPP) fleet. Within the LWRS program, the Flexible Plant Operation and Generation (FPOG) Pathway works to diversify the revenue streams of light water reactors (LWRs) by opening opportunities for the co-generation of non-electric products in addition to supplying electrical power to the grid. Recent events have added greater motivation to these efforts. For example, the recent Inflation Reduction Act (IRA) passed by the U.S. federal government offers substantial tax incentives for producing clean hydrogen, the technology readiness level of dispatchable and high-efficiency hydrogen production has dramatically increased in a short time, and societal response to world climate change is driving a transition away from fossil fuels. Producing hydrogen with maximum efficiency using nuclear power requires dispatching both electrical and thermal power from the nuclear plant to the hydrogen plant, so testing concepts of operations for combined electrical and thermal power dispatch (TPD) from an NNP to a hydrogen plant is of interest. This report documents achievement of the Light Water Reactor Sustainability (LWRS) program milestone “Install and demonstrate a vendor-developed simulator on the Human Systems Simulation Laboratory (HSS) for dispatch of LWR electrical power to a close-coupled electrolysis plant” with a due date of Dec. 22, 2022. Several factors provide motivation for this effort. Coupling the power generation deck of a nuclear power plant to a hydrogen production facility introduces new possibilities for operational transients that must be addressed. In particular, the performance of the integrated system during startup and shutdown of the hydrogen production facility, as well as offnormal conditions, need to be evaluated to ensure there are no adverse effects on the operation of the existing NPP. The concept of operations involving the NPP, the hydrogen plant, and the electric power grid must be tested using NPP simulators and operating procedures that have been modified for TPD operations. These tests must also include dynamic simulations of the coupled tertiary thermal and electric loads as well as coordinated activities with NPP operators, tertiary load operators and grid power coordinators. The report summarizes progress in developing and testing full-scope NPP simulators at the HSSL, including a generic BWR simulator from GSE Systems, Inc. and generic PWR simulator from Westinghouse. In the case of the TPD-GBWR Simulator from GSE Systems, Inc., a BWR is thermally coupled to a high temperature electrolysis (HTE) plant that produces hydrogen and oxygen from de-ionized water. The hydrogen plant is not explicitly simulated but only included as a transient heat sink. A thermal power dispatch (TPD) system transfers heat between the steam systems at the BWR and the hydrogen plant. Operational results from two versions of the modified simulator are presented. The first version uses synthetic oil as a heat transfer fluid in a closed delivery heat loop (DHL) that generates steam at the hydrogen plant. The second version uses steam as the heat transfer fluid in a delivery steam line (DSL) to provide steam to the hydrogen plant. For both versions, the estimated thermal power delivery distance is approximately one kilometer. The amount of thermal power dispatched in the simulators is 15% of the total reactor thermal power such that the simulators provide a tool to study the feasibility of coupling a BWR to industrial processes that benefit from a combination electrical and thermal power dispatch. Ongoing work within a CRADA is also developing a full-scope PWR simulator provided by Westinghouse for both thermal and electric power coupling. This simulator is based on a PWR plant with two three-loop Westinghouse reactors. Westinghouse PWRs are sufficiently similar that a simulator of a three-loop reactor is an appropriate representation for two-loop and four-loop PWR reactors. The three-loop simulator will initially be modified for close-coupling to a 100 MW HTE hydrogen production plant that will require approximately 25 MW of thermal power while operating at its maximum rated capacity. The simulator testing will include full coupling to dynamic simulations of a hydrogen production plant and a representative bulk electric grid. The simulator provided by Westinghouse is similar to the GPWR simulator that INL has already obtained from GSE Systems but has a few important added benefits. First, the Westinghouse simulator is based on digital controls and has additional screens that can be called up to show parameter trends to assist operators in decision-making. The Westinghouse simulator also has upgrades to the controls and hardware representations, such as valve actuators, that make it more realistic and flexible in terms of accurately sim

99 GENERAL AND MISCELLANEOUS↗

A multi-scale time-series dataset with benchmark for machine learning in decarbonized energy grids

The electric grid is a key enabling infrastructure for the ambitious transition towards carbon neutrality as we grapple with climate change. With deepening penetration of renewable resources, the reliable operation of the electric grid becomes increasingly challenging. In this paper, we present PSML, a first-of-its-kind open-access multi-scale time-series dataset, to aid in the development of data-driven machine learning (ML)-based approaches towards reliable operation of future electric grids. The dataset is synthesized from a joint transmission and distribution electric grid to capture the increasingly important interactions and uncertainties of the grid dynamics, containing power, voltage and current measurements over multiple spatio-temporal scales. Using PSML, we provide state-of-the-art ML benchmarks on three challenging use cases of critical importance to achieve: (i) early detection, accurate classification and localization of dynamic disturbances; (ii) robust hierarchical forecasting of load and renewable energy; and (iii) realistic synthetic generation of physical-law-constrained measurements. We envision that this dataset will provide use-inspired ML research in safety-critical systems, while simultaneously enabling ML researchers to contribute towards decarbonization of energy sectors.

54 ENVIRONMENTAL SCIENCES↗

Current Observer Based Predictive Decoupled Power Control Grid-Interactive Inverter

This paper presents a sensor-less current model predictive control (MPC) scheme via a full state observer based current estimator. The grid interactive inverters’ control schemes require current and voltage sensors. Elimination of current sensor enhances the inverter reliability. This paper leverages the inherent characteristics of MPC towards robust current sensor-less grid interactive inverter with LC filter. The observer for inductor current is developed based on the existing capacitor voltage measurement. The estimator dynamic state-space matrices are then obtained through reconstruction of the inverter model with the capacitor voltage and inductor current being the state variables. The controller objectives are to regulate active and reactive power in a decoupled manner. The theoretical expectation, controller performance, and accuracy of the current estimation are verified by conducting a real-time simulation via Typhoon HIL.

Zhang, Zhen↗

Guest Editorial: Advanced Data-Analytics for Power System Operation, Control, and Enhanced Situational Awareness

Along with the smart grid development, modern power systems are entering a ‘data-intensive’ era. A vast volume of data from power grids is being collected through advanced sensing and communication technologies, such as smart metering data, phasor measurement data, as well as meteorological data (e.g., wind speed and solar irradiance) related to renewable power generation. Such data contains comprehensive information about the power system covering equipment's health status, power grid's static and dynamic characteristics, renewable power generation, customers’ electricity usage pattern, etc. Therefore, advanced data-analytics techniques are needed to convert such data to knowledge for practical applications. In line with the trend of widespread data-driven applications in power systems, this Special Issue aims to present state-of-the-art research works on advanced data-analytics for power system's operation, control, and situational awareness. There are in total twenty-six papers accepted for publication in this Special Issue through careful peer reviews and revisions. Under the overarching theme of data-driven applications in power systems, the selected papers are broadly categorised into five topics. The summary of every topic is given below. You are, however, strongly encouraged to read the full paper if interested.

Xu, Yan↗