Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Power Measurements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

Internal electron transport barrier due to neoclassical ambipolarity in the Helically Symmetric Experiment

Electron cyclotron heated plasmas in the Helically Symmetric Experiment (HSX) feature strongly peaked electron temperature profiles; central temperatures are 2.5 keV with 100 kW injected power. These measurements, coupled with neoclassical predictions of large 'electron root' radial electric fields with strong radial shear, are evidence of a neoclassically driven thermal transport barrier. Neoclassical transport quantities are calculated using the PENTA code [D. A. Spong, Phys. Plasmas 12, 056114 (2005)], in which momentum is conserved and parallel flow is included. Unlike a conventional stellarator, which exhibits strong flow damping in all directions on a flux surface, quasisymmetric stellarators are free to rotate in the direction of symmetry, and the effect of momentum conservation in neoclassical calculations may therefore be significant. Momentum conservation is shown to modify the neoclassical ion flux and ambipolar ion root radial electric fields in the quasisymmetric configuration. The effect is much smaller in a HSX configuration where the symmetry is spoiled. In addition to neoclassical transport, a model of trapped electron mode turbulence is used to calculate the turbulent-driven electron thermal diffusivity. Turbulent transport quenching due to the neoclassically predicted radial electric field profile is needed in predictive transport simulations to reproduce the peaking of the measured electron temperature profile [Guttenfelder et al., Phys. Rev. Lett. 101, 215002 (2008)].

43 PARTICLE ACCELERATORS↗

Directional elliptically polarized terahertz emission from air plasma produced by circularly polarized intense femtosecond laser pulses

We have observed directional elliptically polarized terahertz (THz) waves emitted from air plasma produced by circularly polarized femtosecond laser pulses. The spatial distribution of the THz waves shows that the radiation is strongly directed forward with a peak around the laser propagation direction. Measured THz power shows a square dependence on laser energy. We consider the parametric decay of laser light to R-waves in plasma in the presence of a spontaneous magnetic field as a possible explanation for the polarization, power dependence, and direction of the THz beam.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optical emission spectroscopic diagnostics of a non-thermal atmospheric pressure helium-oxygen plasma jet for biomedical applications

In this work, we have applied optical emission spectroscopy diagnostics to investigate the characteristics of a non-thermal atmospheric pressure helium plasma jet. The discharge characteristics in the active and afterglow region of the plasma jet, that are critical for biomedical applications, have been investigated. The voltage-current characteristics of the plasma discharge were analyzed and the average plasma power was measured to be around 18 W. The effect of addition of small fractions of oxygen at 0.1%-0.5% on the plasma jet characteristics was studied. The addition of oxygen resulted in a decrease in plasma plume length due to the electronegativity property of oxygen. Atomic and molecular lines of selected reactive plasma species that are considered to be useful to induce biochemical reactions such as OH transitions A{sup 2}{Sigma}{sup +}({nu}=0,1){yields}X{sup 2}{Pi}({Delta}{nu}=0) at 308 nm and A{sup 2}{Sigma}{sup +}({nu}=0,1){yields}X{sup 2}{Pi}({Delta}{nu}=1) at 287 nm, O I transitions 3p{sup 5}P{yields}3s{sup 5}S{sup 0} at 777.41 nm, and 3p{sup 3}P{yields}3s{sup 3}S{sup 0} at 844.6 nm, N{sub 2}(C-B) second positive system with electronic transition C{sup 3}{Pi}{sub u}{sup {yields}}B{sup 3}{Pi}{sub g}'' in the range of 300-450 nm and N{sub 2}{sup +}(B-X) first negative system with electronic transition B{sup 2}{Sigma}{sub u}{sup +}{yields}X{sup 2}{Sigma}{sub g}{sup +}({Delta}{nu}=0) at 391.4 nm have been studied. The atomic emission lines of helium were identified, including the He I transitions 3p{sup 3}P{sup 0}{yields}2s{sup 3}S at 388.8 nm, 3p{sup 1}P{sup 0}{yields} 2s{sup 1}S at 501.6 nm, 3d{sup 3}D{yields}2p{sup 3}P{sup 0} at 587.6 nm, 3d{sup 1}D{yields}2p{sup 1}P{sup 0} at 667.8 nm, 3s{sup 3}S{sup 1}{yields}2p{sup 3}P{sup 0} at 706.5 nm, 3s{sup 1}S{sup 0}{yields}2p{sup 1}P{sup 0} at 728.1 nm, and H{sub {alpha}} transition 2p-3d at 656.3 nm. Using a spectral fitting method, the OH radicals at 306-312 nm, the rotational and vibrational temperatures equivalent to gas temperatures of the discharge was measured and the effective non-equilibrium nature of the plasma jet was demonstrated. Our results show that, in the entire active plasma region, the gas temperature remains at 310 {+-} 25 K and 340 {+-} 25 K and it increases to 320 {+-} 25 K and 360 {+-} 25 K in the afterglow region of the plasma jet for pure helium and helium/oxygen (0.1%) mixture, respectively. Additionally, the vibrational temperatures range from 2200 {+-} 100 K and 2500 {+-} 100 K for pure helium and helium/oxygen (0.1%) mixture, respectively. The plasma jet was tested on heat sensitive polymer films used in biomedical applications such as polyethylene terephthalate and poly-L-lactide samples continuously for several minutes without causing any physical or thermal damage to the films. The plasma jet produces significant reactive species of interest while the gas temperatures remain very low demonstrating its potential for a range of biomedical applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The MESA polarimetry chain and the status of its double scattering polarimeter

We plan to have two independent polarimetry systems at MESA based on totally different physical processes. A first one tries to minimize the systematic uncertainties in double polarized Mo/ller scattering, which is to be achieved by stored hydrogen atoms in an atomic trap (Hydro-Mo/ller-Polarimeter). The other one relies on the equality of polarizing and analyzing power which allows to measure the effective analyzing power of a polarimeter with very high accuracy. Since the status of Hydro-Mo/ller is presented in a separate paper we concentrate on the double scattering polarimeter in this article.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of aging effects in a Ti-6AL-4V alloy with Widmanstätten and equiaxed microstructures by non-destructive means

When the Ti-6Al-4V alloy is over-aged at 500-600°C, nanometer-sized α{sub 2} (Ti{sub 3}Al) phases can be homogeneously precipitated inside α phases, thereby leading to the additional improvement of mechanical properties. The present study was concerned with the effects of over-aging on thermoelectric power (TEP) measurements in a Ti-6Al-4V alloy. Widmanstätten and equiaxed microstructures containing fine and agr{sub 2} (Ti{sub 3}Al) particles were obtaining by over-aging a Ti-6Al-4V alloy. Over-aging heat treatments were conducted at 515°C, 545°C and 575°C for different aging times. In order to find out the factors affecting the variation in the TEP, the over-aging samples were examined by optical microscopy (OM) and (SEM) scanning electron microscopy. In particular, we studied the behavior of the physical material property hardness, an important parameter of the Ti-6Al-4V alloy mechanical properties, with respect to the variation in the aging time and temperature. It was found that the TEP measurements reveal an increase in the magnitude of the absolute TEP value of the over-aged Widmanstätten and equiaxed microstructures with regards to the unaged condition for different aging times, with a somewhat higher value at 515°C.

36 MATERIALS SCIENCE↗

Terahertz oscillations in an In{sub 0.53}Ga{sub 0.47}As submicron planar Gunn diode

The length of the transit region of a Gunn diode determines the natural frequency at which it operates in fundamental mode—the shorter the device, the higher the frequency of operation. The long-held view on Gunn diode design is that for a functioning device the minimum length of the transit region is about 1.5 μm, limiting the devices to fundamental mode operation at frequencies of roughly 60 GHz. Study of these devices by more advanced Monte Carlo techniques that simulate the ballistic transport and electron-phonon interactions that govern device behaviour, offers a new lower bound of 0.5 μm, which is already being approached by the experimental evidence that has shown planar and vertical devices exhibiting Gunn operation at 600 nm and 700 nm, respectively. The paper presents results of the first ever THz submicron planar Gunn diode fabricated in In{sub 0.53}Ga{sub 0.47}As on an InP substrate, operating at a fundamental frequency above 300 GHz. Experimentally measured rf power of 28 μW was obtained from a 600 nm long × 120 μm wide device. At this new length, operation in fundamental mode at much higher frequencies becomes possible—the Monte Carlo model used predicts power output at frequencies over 300 GHz.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Study of heat sources interacting in integrated circuits by laser mirage effect

This work exploits the mirage effect to analyze multiple heat sources thermally interacting in an integrated circuit (IC) by means of a probe IR laser beam, which strikes on the die lateral walls and passes through the die substrate. Under such conditions, the criteria for locating such hot spots, as well as their relative power dissipation, are discussed on the basis of a theoretical model inferred in this work. Finally, the technique feasibility is shown in a real application scenario, obtaining 5-μm spatial lateral resolution and an error in power dissipation measurements below 5%. This method may become a practical alternative to usual off-chip techniques for inspecting hot spots in ICs and to experimentally characterize heat flow in the semiconductor substrate.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A segmented multi-loop antenna for selective excitation of azimuthal mode number in a helicon plasma source

A flat type, segmented multi-loop antenna was developed in the Tokai Helicon Device, built for producing high-density helicon plasma, with a diameter of 20 cm and an axial length of 100 cm. This antenna, composed of azimuthally splitting segments located on four different radial positions, i.e., r = 2.8, 4.8, 6.8, and 8.8 cm, can excite the azimuthal mode number m of 0, ±1, and ±2 by a proper choice of antenna feeder parts just on the rear side of the antenna. Power dependencies of the electron density n{sub e} were investigated with a radio frequency (rf) power less than 3 kW (excitation frequency ranged from 8 to 20 MHz) by the use of various types of antenna segments, and n{sub e} up to ∼5 × 10{sup 12} cm{sup −3} was obtained after the density jump from inductively coupled plasma to helicon discharges. Radial density profiles of m = 0 and ±1 modes with low and high rf powers were measured. For the cases of these modes after the density jump, the excited mode structures derived from the magnetic probe measurements were consistent with those expected from theory on helicon waves excited in the plasma.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Perspective gyrotron with mode converter for co- and counter-rotation operating modes

A gyrotron oscillator operating efficiently at modes of both rotations was developed and tested. The gyrotron operation can be switched between two modes: co- and counter rotating ones with respect to electron rotation in a resonance magnetic field. A synthesized mode converter provides output of both waves in the form of two different paraxial wave beams corresponding to direction of the mode rotation. Measured gyrotron power (up to 2 MW), interaction efficiency (34%), and diffraction losses in the mode converter (≈2%) agree well with the design values. The proposed gyrotron scheme alloys principal enhancement in the device parameters—possibility of electronic switching of output wave beam direction and possibility to arrange an effective scheme to provide frequency/phase locking of a gyrotron-oscillator.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

An FPGA-based bolometer for the MAST-U Super-X divertor

A new resistive bolometer system has been developed for MAST-Upgrade. It will measure radiated power in the new Super-X divertor, with millisecond time resolution, along 16 vertical and 16 horizontal lines of sight. The system uses a Xilinx Zynq-7000 series Field-Programmable Gate Array (FPGA) in the D-TACQ ACQ2106 carrier to perform real time data acquisition and signal processing. The FPGA enables AC-synchronous detection using high performance digital filtering to achieve a high signal-to-noise ratio and will be able to output processed data in real time with millisecond latency. The system has been installed on 8 previously unused channels of the JET vertical bolometer system. Initial results suggest good agreement with data from existing vertical channels but with higher bandwidth and signal-to-noise ratio.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental demonstration of a 5th harmonic mm-wave frequency multiplying vacuum tube

Here, we report the experimental demonstration of a 5th harmonic mm-wave frequency multiplying vacuum electronic device, which uses an over-moded spherical sector output cavity. In this device, a pencil electron beam is helically deflected in a transverse deflecting cavity before entering the output cavity. No magnetic field is required to focus or guide the beam. We built and tested a proof-of-principle device with an output frequency of 57.12 GHz. The measured peak power was 52.67 W at the 5th harmonic of the drive frequency. Power at the 4th, 6th, and 7th harmonics was 33.28 dB lower than that at the 5th harmonic.

43 PARTICLE ACCELERATORS↗

A proton beam energy modulator for rapid proton therapy

We present the design for a rapid proton energy modulator with radiofrequency accelerator cavities, which can deliver the proton radiation dose to varied depth in human tissues much faster than traditional mechanical beam energy degraders. The proton energy modulator is designed as a multi-cell 1-m long accelerator working at 2.856 GHz. Each individual accelerator cavity is powered by a 400 kW compact klystron to provide an accelerating/decelerating gradient of 30 MV/m. The high gradient is enabled by the individual power coupling regime, which provides a high shunt impedance. Beam dynamics simulations were performed, showing that the energy modulator can provide ±30 MeV of beam energy change for a 150 MeV, 7 mm long (full length) proton bunch, and the total energy spread of 3 MeV is satisfactory to clinical needs. A prototype experiment of a single cell has been built and tested, and the low-power microwave measurement results agree very well with simulations. The energy modulator is optimized for the 150 MeV cyclotron proton beam, while this approach can work with different beam energies.

47 OTHER INSTRUMENTATION↗

Spectrally resolved fluorescence diffuse tomography of biological tissues

Spectrally resolved fluorescence diffuse tomography (SFDT) is demonstrated to be an effective approach to the reconstruction of the fluorescent agent distribution in biological tissues. Analysis of the measured optical power spectrum enables more accurate fluorophore localisation in solving the inverse tomography problem, because the dispersion of the optical parameters of the imaging subject leads to characteristic changes in the shape of its fluorescence spectrum. The SFDT system built by us includes a common optical fibre output of light sources and a single fibre input of the detector in an on-axis configuration, and an electromechanical scanner. The system enables studies of laboratory animals having tumours labelled with various fluorescent agents (fluorescent proteins, quantum dots and others). The first in vivo experiments have demonstrated the feasibility of tumour detection and localisation in laboratory animals by SFDT. (optical tomography)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MEAN-FLUX-REGULATED PRINCIPAL COMPONENT ANALYSIS CONTINUUM FITTING OF SLOAN DIGITAL SKY SURVEY Ly{alpha} FOREST SPECTRA

Continuum fitting is an important aspect of Ly{alpha} forest science, since errors in the derived optical depths scale with the fractional continuum error. However, traditional methods of estimating continua in noisy and moderate-resolution spectra (e.g., Sloan Digital Sky Survey, SDSS; S/N {approx}< 10 pixel{sup -1} and R {approx} 2000), such as power-law extrapolation or dividing by the mean spectrum, achieve no better than {approx}15% rms accuracy. To improve on this, we introduce mean-flux-regulated principal component analysis (MF-PCA) continuum fitting. In this technique, PCA fitting is carried out redward of the quasar Ly{alpha} line in order to provide a prediction for the shape of the Ly{alpha} forest continuum. The slope and amplitude of this continuum prediction is then corrected using external constraints for the Ly{alpha} forest mean flux. This requires prior knowledge of the mean flux, (F), but significantly improves the accuracy of the flux transmission, F {identical_to} exp (- {tau}), estimated from each pixel. From tests on mock spectra, we find that MF-PCA reduces the errors to 8% rms in S/N {approx} 2 spectra, and <5% rms in spectra with S/N {approx}> 5. The residual Fourier power in the continuum is decreased by a factor of a few in comparison with dividing by the mean continuum, enabling Ly{alpha} flux power spectrum measurements to be extended to {approx}2 Multiplication-Sign larger scales. Using this new technique, we make available continuum fits for 12,069 z > 2.3 Ly{alpha} forest spectra from SDSS Data Release 7 for use by the community. This technique is also applicable to future releases of the ongoing Baryon Oscillations Spectroscopic Survey, which obtains spectra for {approx}150, 000 Ly{alpha} forest spectra at low signal-to-noise (S/N {approx} 2).

79 ASTRONOMY AND ASTROPHYSICS↗

A PER-BASELINE, DELAY-SPECTRUM TECHNIQUE FOR ACCESSING THE 21 cm COSMIC REIONIZATION SIGNATURE

A critical challenge in measuring the power spectrum of 21 cm emission from cosmic reionization is compensating for the frequency dependence of an interferometer's sampling pattern, which can cause smooth-spectrum foregrounds to appear unsmooth and degrade the separation between foregrounds and the target signal. In this paper, we present an approach to foreground removal that explicitly accounts for this frequency dependence. We apply the delay transformation introduced in Parsons and Backer to each baseline of an interferometer to concentrate smooth-spectrum foregrounds within the bounds of the maximum geometric delays physically realizable on that baseline. By focusing on delay modes that correspond to image-domain regions beyond the horizon, we show that it is possible to avoid the bulk of smooth-spectrum foregrounds. We map the point-spread function of delay modes to k-space, showing that delay modes that are uncorrupted by foregrounds also represent samples of the three-dimensional power spectrum, and can be used to constrain cosmic reionization. Because it uses only spectral smoothness to differentiate foregrounds from the targeted 21 cm signature, this per-baseline analysis approach relies on spectrally and spatially smooth instrumental responses for foreground removal. For sufficient levels of instrumental smoothness relative to the brightness of interfering foregrounds, this technique substantially reduces the level of calibration previously thought necessary to detect 21 cm reionization. As a result, this approach places fewer constraints on antenna configuration within an array, and in particular, facilitates the adoption of configurations that are optimized for power-spectrum sensitivity. Under these assumptions, we demonstrate the potential for the Precision Array for Probing the Epoch of Reionization (PAPER) to detect 21 cm reionization at an amplitude of 10 mK{sup 2} near k {approx} 0.2 h Mpc{sup -1} with 132 dipoles in 7 months of observing.

79 ASTRONOMY AND ASTROPHYSICS↗

REIONIZATION ON LARGE SCALES. III. PREDICTIONS FOR LOW-l COSMIC MICROWAVE BACKGROUND POLARIZATION AND HIGH-l KINETIC SUNYAEV-ZEL'DOVICH OBSERVABLES

We present new predictions for cosmic microwave background (CMB) temperature (on small angular scales) and polarization (on large angular scales) anisotropies induced during the epoch of reionization (EoR). Using a novel method calibrated from radiation-hydrodynamic simulations, we model the EoR in large volumes (L ∼> 2 Gpc h {sup –1}). We find that the EoR contribution to the kinetic Sunyaev-Zel'dovich power spectrum (patchy kSZ) ranges between ∼0.6-2.8 μK{sup 2} at l = 3000 for the explored parameter space. For each model, the patchy kSZ power spectrum is calculated from three large 15° × 15° maps for better numerical convergence. Decreasing the size of these maps biases the overall patchy kSZ power to higher values. We find that the amplitude of the patchy kSZ power spectrum at l = 3000 follows simple scalings of D{sub l=3000}{sup kSZ}∝ z-bar and D{sub l=3000}{sup kSZ}∝Δ{sub z}{sup 0.51} for the mean redshift ( z-bar ) and duration (Δ{sub z}) of reionization. Using the constraints on z-bar from the Wilkinson Microwave Anisotropy Probe seven year results and the lower limit on Δ{sub z} from EDGES, we find a lower limit of ∼0.4 μK{sup 2} at l = 3000. Planck will infer the mean redshift from the Thomson optical depth imprinted in the low-l polarization power spectrum. Future measurements of the high-l CMB power spectrum from the Atacama Cosmology Telescope and South Pole Telescope should detect the patchy kSZ signal if the cross correlation between the thermal SZ effect and the cosmic infrared background is constrained. We show that the combination of temperature and polarization measurements constrains both z-bar and Δ{sub z}. The patchy kSZ maps, power spectra templates, and the polarization power spectra will be publicly available.

79 ASTRONOMY AND ASTROPHYSICS↗

Dark energy and Josephson junctions

It has been recently claimed that dark energy can be (and has been) observed in laboratory experiments by measuring the power spectrum S{sub I}(ω) of the noise current in a resistively shunted Josephson junction and that in new dedicated experiments, which will soon test a higher frequency range, S{sub I}(ω) should show a deviation from the linear rising observed in the lower frequency region because higher frequencies should not contribute to dark energy. Based on previous work on theoretical aspects of the fluctuation-dissipation theorem, we carefully investigate these issues and show that these claims are based on a misunderstanding of the physical origin of the spectral function S{sub I}(ω). According to our analysis, dark energy has never been (and will never be) observed in Josephson junctions experiments. We also predict that no deviation from the linear rising behavior of S{sub I}(ω) will be observed in forthcoming experiments. Our findings provide new (we believe definite) arguments which strongly support previous criticisms.

79 ASTRONOMY AND ASTROPHYSICS↗

Effects and detectability of quasi-single field inflation in the large-scale structure and cosmic microwave background

Quasi-single field inflation predicts a peculiar momentum dependence in the squeezed limit of the primordial bispectrum which smoothly interpolates between the local and equilateral models. This dependence is directly related to the mass of the isocurvatons in the theory which is determined by the supersymmetry. Therefore, in the event of detection of a non-zero primordial bispectrum, additional constraints on the parameter controlling the momentum-dependence in the squeezed limit becomes an important question. We explore the effects of these non-Gaussian initial conditions on large-scale structure and the cosmic microwave background, with particular attention to the galaxy power spectrum at large scales and scale-dependence corrections to galaxy bias. We determine the simultaneous constraints on the two parameters describing the QSF bispectrum that we can expect from upcoming large-scale structure and cosmic microwave background observations. We find that for relatively large values of the non-Gaussian amplitude parameters, but still well within current uncertainties, galaxy power spectrum measurements will be able to distinguish the QSF scenario from the predictions of the local model. A CMB likelihood analysis, as well as Fisher matrix analysis, shows that there is also a range of parameter values for which Planck data may be able distinguish between QSF models and the related local and equilateral shapes. Given the different observational weightings of the CMB and LSS results, degeneracies can be significantly reduced in a joint analysis.

79 ASTRONOMY AND ASTROPHYSICS↗