Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Positioning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

Optimizing iodine adsorption in functionalized metal-organic frameworks via an unprecedented positional isomerism strategy

Porous metal–organic frameworks (MOFs) have emerged as highly promising adsorbents for capturing radioiodine, a predominant fission product released during nuclear fuel reprocessing. However, systematic investigations into the correlation between MOF structure and iodine uptake capacity remain scarce. Here, we present a novel approach to enhance the iodine adsorption capacity of MOFs by optimizing linker functionalization. Using ligand-functionalized thorium-based MOFs as a structural platform, we demonstrate that ortho-amino-substitution near the node of the dicarboxylate linker significantly increases iodine adsorption capacity compared to meta-amino-substitution, where the amino groups are directed away from the node. Specifically, ortho-substituted Th-UiO-68-3,3”-(NH 2 ) 2 exhibits higher iodine uptake capacities than the meta-substituted Th-UiO-68-2,2”-(NH 2 ) 2 via both vapor diffusion-based (2.042 vs. 1.087 g/g) and solution-based (0.841 vs. 0.784 g/g) processes. Notably, the I 2 vapor adsorption capacity (2.042 g/g) of Th-UiO-68-3,3”-(NH 2 ) 2 represents the second highest among all reported Th-MOFs. Pair distribution function (PDF) studies reveal that the superior iodine uptake performance of ortho-functionalized MOFs can be attributed to the reduced steric hindrance of the amino groups compared with the meta-substituted variants. Finally, this research highlights how positional isomerism and its subtle alterations can significantly influence host–guest interactions, extending beyond simple structural considerations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Soret transport, unequal diffusivity, and dilution effects on laminar diffusion flame temperatures and positions

Since, according to ideal gas kinetic theory, Ludwig-Soret species transport (temperature-gradient-driven mass transport) must be simultaneously included along with nonunity Lewis numbers [D.E. Rosner, R.S. Israel, B. La Mantia, Combust. Flame 123 (2000) 547-560], we formally consider here the influence of both effects on laminar, counterflow gaseous diffusion flames in the thin flame limit. Our deliberately idealized theoretical analysis includes cases of steady/unsteady, strained/unstrained flames and formally permits the prediction of trends for the combustion of either light or heavy fuel vapors in O{sub 2}-containing streams. Our results suggest that, in cases of low- or high-molecular-weight gaseous fuels, Ludwig-Soret transport can itself introduce significant shifts in flame position and flame temperature, compared to results of the same mathematical model neglecting Soret fuel-vapor transport but including only nonunity fuel Lewis numbers. These systematic shifts (which in specific cases may have to be supplemented by additional corrections due to variable thermophysical properties) are expected to have important consequences for NO{sub x} production and/or infrared radiation emission. (author)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Stability, Visibility, and Histologic Analysis of a New Implanted Fiducial for Use as a Kilovoltage Radiographic or Radioactive Marker for Patient Positioning and Monitoring in Radiotherapy

Purpose: To analyze the stability, visibility, and histology of a novel implantable soft-tissue marker (nonradioactive and radioactive) implanted in dog prostate and rabbit liver. Methods and Materials: A total of 34 nonradioactive and 35 radioactive markers were implanted in 1 dog and 16 rabbits. Stability was assessed by measuring intermarker distance (IMD) variation relative to IMDs at implantation. The IMDs were measured weekly for 4 months in the dog and biweekly for 2-4 weeks in the rabbits. Ultrasound and X-ray imaging were performed on all subjects. Computed tomography and MRI were performed on the dog. Histologic analysis was performed on the rabbits after 2 or 4 months. Results: A total of 139 measurements had a mean ({+-} SD) absolute IMD variation of 1.1 {+-} 1.1 mm. These IMD variations are consistent with those reported in the literature as due to random organ deformation. The markers were visible, identifiable, and induced minimal or no image artifacts in all tested imaging modalities. Histologic analysis revealed that all pathologic changes were highly localized and not expected to be clinically significant. Conclusions: The markers were stable from the time of implantation. The markers were found to be compatible with all common medical imaging modalities. The markers caused no significant histologic effects. With respect to marker stability, visibility, and histologic analysis these implanted fiducials are appropriate for soft-tissue target positioning in radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Tracking Accuracy of a Real-Time Fiducial Tracking System for Patient Positioning and Monitoring in Radiation Therapy

Purpose: In radiation therapy there is a need to accurately know the location of the target in real time. A novel radioactive tracking technology has been developed to answer this need. The technology consists of a radioactive implanted fiducial marker designed to minimize migration and a linac mounted tracking device. This study measured the static and dynamic accuracy of the new tracking technology in a clinical radiation therapy environment. Methods and Materials: The tracking device was installed on the linac gantry. The radioactive marker was located in a tissue equivalent phantom. Marker location was measured simultaneously by the radioactive tracking system and by a Microscribe G2 coordinate measuring machine (certified spatial accuracy of 0.38 mm). Localization consistency throughout a volume and absolute accuracy in the Fixed coordinate system were measured at multiple gantry angles over volumes of at least 10 cm in diameter centered at isocenter. Dynamic accuracy was measured with the marker located inside a breathing phantom. Results: The mean consistency for the static source was 0.58 mm throughout the tested region at all measured gantry angles. The mean absolute position error in the Fixed coordinate system for all gantry angles was 0.97 mm. The mean real-time tracking error for the dynamic source within the breathing phantom was less than 1 mm. Conclusions: This novel radioactive tracking technology has the potential to be useful in accurate target localization and real-time monitoring for radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Inter- and Intrafraction Patient Positioning Uncertainties for Intracranial Radiotherapy: A Study of Four Frameless, Thermoplastic Mask-Based Immobilization Strategies Using Daily Cone-Beam CT

Purpose: To determine whether frameless thermoplastic mask-based immobilization is adequate for image-guided cranial radiosurgery. Methods and Materials: Cone-beam CT localization data from patients with intracranial tumors were studied using daily pre- and posttreatment scans. The systems studied were (1) Type-S IMRT (head only) mask (Civco) with head cushion; (2) Uni-Frame mask (Civco) with head cushion, coupled with a BlueBag body immobilizer (Medical Intelligence); (3) Type-S head and shoulder mask with head and shoulder cushion (Civco); (4) same as previous, coupled with a mouthpiece. The comparative metrics were translational shift magnitude and average rotation angle; systematic inter-, random inter-, and random intrafraction positioning error was computed. For strategies 1-4, respectively, the analysis for interfraction variability included data from 20, 9, 81, and 11 patients, whereas that for intrafraction variability included a subset of 7, 9, 16, and 8 patients. The results were compared for statistical significance using an analysis of variance test. Results: Immobilization system 4 provided the best overall accuracy and stability. The mean interfraction translational shifts ({+-} SD) were 2.3 ({+-} 1.4), 2.2 ({+-} 1.1), 2.7 ({+-} 1.5), and 2.1 ({+-} 1.0) mm whereas intrafraction motion was 1.1 ({+-} 1.2), 1.1 ({+-} 1.1), 0.7 ({+-} 0.9), and 0.7 ({+-} 0.8) mm for devices 1-4, respectively. No significant correlation between intrafraction motion and treatment time was evident, although intrafraction motion was not purely random. Conclusions: We find that all frameless thermoplastic mask systems studied are viable solutions for image-guided intracranial radiosurgery. With daily pretreatment corrections, symmetric PTV margins of 1 mm would likely be adequate if ideal radiation planning and targeting systems were available.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Interfractional Positional Variability of Fiducial Markers and Primary Tumors in Locally Advanced Non-Small-Cell Lung Cancer During Audiovisual Biofeedback Radiotherapy

Purpose: To evaluate implanted markers as a surrogate for tumor-based setup during image-guided lung cancer radiotherapy with audiovisual biofeedback. Methods and Materials: Seven patients with locally advanced non-small-cell lung cancer were implanted bronchoscopically with gold coils. Markers, tumor, and a reference bony structure (vertebra) were contoured for all 10 phases of the four-dimensional respiration-correlated fan-beam computed tomography and weekly four-dimensional cone-beam computed tomography. Results: The systematic/random interfractional marker-to-tumor centroid displacements were 2/3, 2/2, and 3/3 mm in the x (lateral), y (anterior-posterior), and z (superior-inferior) directions, respectively. The systematic/random interfractional marker-to-bone displacements were 2/3, 2/3, and 2/3 mm in the x, y, and z directions, respectively. The systematic/random tumor-to-bone displacements were 2/3, 2/4, and 4/4 mm in the x, y, and z directions, respectively. All displacements changed significantly over time (p < 0.0001). Conclusions: Although marker-based image guidance may decrease the risk for geometric miss compared with bony anatomy-based positioning, the observed displacements between markers and tumor centroids indicate the need for repeated soft tissue imaging, particularly in situations with large tumor volume change and large initial marker-to-tumor centroid distance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Computer-controlled finishing via dynamically constraint position-velocity-time scheduler

In a Computer Numerical Controlled (CNC) finishing process, the target material removal from an optical surface is guided by the convolution between the influence function of a machine tool and its dwell time at certain points over the surface. To reduce dynamics stressing and increase machining efficiency, the dwell time must be converted to varying velocities, which are the actual inputs to the machine tool controller. Conventionally, the conversion assumed constant acceleration and relied on linear motion interpolation, which caused discontinuities in velocities. This unsmooth motion affects the material removal distribution, and, thus, the accuracy of the finished surface shape. Many modern CNC machines support the smoother, cubic-polynomial interpolated Position-Velocity-Time (PVT) motion mode; however, the conventional scheduler may fail to provide suitable velocities for the PVT. Here in this study answers this challenge by proposing a novel PVT-based velocity scheduler that achieves smooth motion while considering CNC dynamic limits. Firstly, the principle of the PVT is explained, and the PVT-based velocity scheduler is formulated. Secondly, a quadratic programming is used to optimize the velocities by imposing the CNC dynamic constraints and the C 1 continuities (zeroth and first derivatives are continuous) simultaneously. Thirdly, the smoothness and accuracy of the scheduled velocities are studied on different kinds of tool paths via simulation. Finally, a sub-0.3 nm level surface finishing experiment using ion beam figuring is demonstrated to verify the feasibility of the proposed method. The PVT-based scheduler and simulator code is open-sourced.

36 MATERIALS SCIENCE↗

Rovibronic molecular line list for the $N_2(C^3Π_u–B^3Π_g)$ second positive system

Here, a line list for the N second positive system, $B^3Π_g—C^3Π_u$, has been compiled using the PGOPHER spectral simulation software. The line list extends the number of vibrational states of the $B^3Π_g$ up to v=29 and a maximum rotational state of J=150 for simulation temperatures up to 7000 K. New electronic–vibrational transition moments were calculated using refined potential energy curves and a transition dipole moment with the DUO software. Comparisons to experimental data and the SPECAIR software have been used to validate the new line list. The results are available in ASCII ExoMol .state and .trans files and as a PGOPHER input file for use in spectral analysis.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Method for Constructing Transverse Real-Space Beam Distributions Using Beam Position Monitors

At the Spallation Neutron Source (SNS) [1,2] in Oak Ridge, we sought to measure the transverse tilt and profile of the beam at several locations in our Ring to Target Beam Transport (RTBT) line where we did not have wire scanners. A new method was proposed and used to construct the transverse real space beam distributions from Beam Position Monitor (BPM) signals. In this paper, we outline this method and present experimental data taken using the technique, and we compare the results with profiles taken using wire scanners.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A novel conditional formulation of the Vlasov–Ampère equations: a conservative, positivity, asymptotic and Gauss law preserving scheme

We propose a novel reformulation of the Vlasov–Ampère equations for plasmas that reveals discrete symmetries that enables simultaneous conservation of mass, momentum and energy; preservation of Gauss’s law; positivity of the distribution function; and consistency with quasi-neutral asymptotics. The approach employs variable and coordinate transformations to yield a coupled system comprising a modified Vlasov equation and associated moment–field equations. The modified Vlasov equation advances a conditional distribution function that excludes mass, momentum and energy densities, which are instead evolved through moment equations enforcing the relevant symmetries, conservation laws and involution constraints. This reformulation aligns naturally with a recent slow-manifold reduction technique, which separates fast electron time scales and simplifies the treatment of the quasi-neutral limit within the reduced moment–field subsystem. Using this framework, we develop a numerical method for the reduced 1D1V subsystem that, for the first time in the literature, satisfies all key physical constraints while maintaining a quasi-neutral asymptotic behaviour. The advantages of the method are demonstrated on canonical electrostatic test problems, including the multiscale ion acoustic shock wave.

1D1V↗

Explaining an Unusually Fast Parasitic Enzyme: Folate Tail-Binding Residues Dictate Substrate Positioning and Catalysis in Cryptosporidium hominis Thymidylate Synthase

The essential enzyme TS-DHFR from Cryptosporidium hominis undergoes an unusually rapid rate of catalysis at the conserved TS domain, facilitated by two nonconserved residues, Ala287 and Ser290, in the folate tail-binding region. Mutation of these two residues to their conserved counterparts drastically affects multiple steps of the TS catalytic cycle. We have determined the crystal structures of all three mutants (A287F, S290G, and A287F/S290G) in complex with active site ligands dUMP and CB3717. The structural data show two effects of the mutations: an increased distance between the ligands in the active site and increased flexibility of the folate ligand in the partially open enzyme state that precedes conformational change to the active catalytic state. The latter effect is able to be rescued by the mutants containing the A287F mutation. In addition, the conserved water network of TS is altered in each of the mutants. The structural results point to a role of the folate tail-binding residues in closely positioning ChTS ligands and restricting ligand flexibility in the partially open state to allow for a rapid transition to the active closed state and enhanced rate of catalysis. These results provide an explanation on how folate tail-binding residues at one end of the active site affect long-range interactions throughout the TS active site and validate these residues as targets for species-specific drug design.

36 MATERIALS SCIENCE↗

An ion thruster internal discharge chamber electrostatic probe diagnostic technique using a high-speed probe positioning system

Extensive resources have been allocated to diagnose and minimize lifetime-limiting factors in gridded ion thrusters. While most of this effort has focused on grid erosion, results from wear tests indicate that discharge cathode erosion may also play an important role in limiting the lifetime of ring-cusp ion thrusters proposed for future large flagship missions. The detailed characterization of the near-cathode discharge plasma is essential for mitigating discharge cathode erosion. However, severe difficulty is encountered when attempting to measure internal discharge plasma parameters during thruster operation with conventional probing techniques. These difficulties stem from the high-voltage, high-density discharge cathode plume, which is a hostile environment for probes. A method for interrogating the discharge chamber plasma of a working ion thruster over a two-dimensional grid is demonstrated. The high-speed axial reciprocating probe positioning system is used to minimize thruster perturbation during probe insertion and to reduce heating of the probe. Electrostatic probe measurements from a symmetric double Langmuir probe are presented over a two-dimensional spatial array in the near-discharge cathode assembly region of a 30-cm-diameter ring-cusp ion thruster. Electron temperatures, 2-5 eV, and number density contours, with a maximum of 8x10{sup 12} cm{sup -3} on centerline, are measured. These data provide detailed electron temperature and number density contours which, when combined with plasma potential measurements, may shed light on discharge cathode erosion processes and the effect of thruster operating conditions on erosion rates.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Position-Sensitive Nuclear Spectroscopy with Pixel Detectors

State-of-the-art hybrid semiconductor pixel detectors such as Medipix2 are suitable for energy- and position-sensitive nuclear spectroscopy. In addition to excellent energy- and spatial-resolution, these devices can operate in spectroscopic, single-quantum counting and/or on-line tracking mode. A devoted compact USB-readout interface provides functionality and ease of operation. The compact and versatile Medipix2/USB radiation camera provides visualization, vacuum and room-temperature operation as a real-time portable active nuclear emulsion.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fine positioning of a poloidal probe array

Multipoint detection is an essential requirement for investigating plasma turbulence which is a highly nonlinear phenomenon in space and time. We have fabricated an array of 64-channel poloidal probes surrounding the linear cylindrical plasma named LMD-U in order to study turbulence properties, particularly the nonlinear mode couplings, in the domain of poloidal wave number and frequency. However, misalignments of probe tips produce spurious modes, which do not exist in the real plasma, to distort the precise wave number measurements. The paper presents the description of the 64-channel poloidal probe array with means to adjust the probe positions, with discussion on the effects of the misalignments on the wave number measurements.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Position-Sensitive Detector with GaAs photocathode and high time resolution

The Position-Sensitive Detector (PSD) on base of GaAs photocathode and microchannel plate set has been developed. PSD consists of thick semi-conductor photocathode with quantum efficiency about 48% in the range of 4000-7500 A, two micro-channel plates, and 16-electrode collector. The detector has spatial resolution of 20-40 microns for about 5{center_dot}10{sup 2} pixels, time resolution of 1 {mu}s and effective sensitivity up to 35%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of incident position of hypervelocity particles on piezoelectric lead zirconate titanate detector

A cosmic dust detector for use onboard a satellite is currently being developed by using piezoelectric lead zirconate titanate (PZT). The characteristics of the PZT detector have been studied by bombarding it with hypervelocity iron (Fe) particles supplied by a Van de Graaff accelerator. One central electrode and four peripheral electrodes were placed on the front surface of the PZT detector to measure the impact positions of the incident Fe particles. It was demonstrated that the point of impact on the PZT detector could be identified by using information on the time at which the first peak of the output signal obtained from each electrode appeared.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗