Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Porous flow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

Freeze-Tolerant Condensers

Two condensers designed for use in dissipating heat carried by working fluids feature two-phase, self-adjusting configurations such that their working lengths automatically vary to suit their input power levels and/or heat-sink temperatures. A key advantage of these condensers is that they can function even if the temperatures of their heat sinks fall below the freezing temperatures of their working fluids and the fluids freeze. The condensers can even be restarted from the frozen condition. The top part of the figure depicts the layout of the first condenser. A two-phase (liquid and vapor) condenser/vapor tube is thermally connected to a heat sink typically, a radiatively or convectively cooled metal panel. A single-phase (liquid) condensate-return tube (return artery) is also thermally connected to the heat sink. At intervals along their lengths, the condenser/vapor tube and the return artery are interconnected through porous plugs. This condenser configuration affords tolerance of freezing, variable effective thermal conductance (such that the return temperature remains nearly constant, independently of the ultimate sink temperature), and overall pressure drop smaller than it would be without the porous interconnections. An additional benefit of this configuration is that the condenser can be made to recover from the completely frozen condition either without using heaters, or else with the help of heaters much smaller than would otherwise be needed. The second condenser affords the same advantages and is based on a similar principle, but it has a different configuration that affords improved flow of working fluid, simplified construction, reduced weight, and faster recovery from a frozen condition.

Crowley, Christopher J.↗

Wash Penalty Factors: Insight into the Effects of Water Wash Down of Building Materials for Radionuclide/Nuclear (Rn) Decontamination - 20153

The release of radiological material to the urban environment can have a devastating socio-economic impact. In an urban release scenario, areas around the dispersal epicenter and any areas contaminated via atmospheric deposition may require extensive decontamination. Most recently, our group reported the decontamination efficacy of pressurized water washing of common porous building materials, and compared the penetration depth of the contaminations before and after exposure to pressurized tap water. Here, we continue evaluation of the decontamination efficacy of wash solutions based on potassium (K{sup +}) salt for cesium (Cs), strontium (Sr), and europium (Eu) contaminations on common building surfaces. The surfaces included: the cement used in concrete, the aggregate used in concrete, intact concrete, roadway asphalt, asphalt shingles, and latex paint. We deposited solutions of {sup 137}Cs, {sup 85}Sr, and {sup 152}Eu onto numerous common building materials and exposed these materials to a static bath or low-pressure flow of tap water, 0.1 M potassium chloride (KCl), and 0.5 M KCl. The decontamination efficacy and the depth profile for residual contamination were measured to determine the conditions under which applying a wash solution has benefit compared to physically removing the surface material. To aid in these analyses, we introduced a 'wash penalty factor' to quantify the degree to which contamination migrated into the bulk material by the action of the wash method. On asphalt, 70-80% of the radionuclides were found to be within 0.02 mm of the surface. Cs{sup +} bonded to negative charge sites on the surface of the mineral aggregate (used in concrete) so decontamination was improved by ion exchange with K{sup +}. Sr{sup 2+} is soluble and removed by water, while not bonding to aggregate or demonstrating solubility in the liquid asphalt. Eu{sup 3+} is precipitated and not removed in gentle wash but displays mobility within the pore space that suggests its presence as a colloid. Concrete is more porous than asphalt, and 80% of the radionuclides were within 0.2 mm of the surface for {sup 137}Cs and {sup 152}Eu and 50- 80% for {sup 85}Sr. On concrete, Cs{sup +} bonds similarly to asphalt. Sr{sup 2+} bonds to the cement or precipitates from the alkaline pore water. Eu{sup 3+} sorbs to the cement and then precipitates. In brick, the results for Cs{sup +} and Sr{sup 2+} suggested that diffusion of ions from deeper in the coupon was important. Eu{sup 3+} is removed poorly due to precipitation. We will explain and report example wash penalty factors that vary from 0 to > 1 for the various methods and the implications for deciding when to implement wash down methods. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Penetration of Fission Products Ions into Complex Solids and the Effect of Ionic Wash Methods

During washing of radiologically impacted building surfaces, penetration of radionuclide ions into complex solids associated with these surfaces may occur. This study investigates the penetration of Cs-137, Sr-85, and Eu-152 solutions into numerous common building materials and radionuclide behavior when these materials were exposed to a static bath or low-pressure flow of tap water, 0.1 M potassium chloride (KCl), and 0.5 M KCl. The decontamination efficacy and the depth profile for residual contamination were measured to determine the conditions under which applying a wash solution has benefit compared to physically removing the surface material. On asphalt, 70-80% of the radionuclides were found to be within 0.02 mm of the surface. Concrete is more porous than asphalt, and 80% of the radionuclides were within 0.2 mm of the surface for Cs-137 and Eu-152 and 50-80% for Sr-85. Water effectively removed all contaminants from hard nonporous surfaces. Finally, this paper illustrates that a wash penalty factor concept-defined as ratio of the depth at which 50% of the radioactivity is found in the washed sample divided by the depth at which 50% of radioactivity is found in the control-can serve as a way to quantify whether the wash method increases the depth at which contamination penetrates into the material and thus the material becomes more difficult to decontaminate.

building materials↗

Development and Validation of Resistance-Capacitance Model for Phase Change Material Embedded in Porous Media

A simple and effective way to enhance PCM thermal conductivity is by embedding porous materials with high thermal conductivities. In this work, CFD was used to evaluate the melting of PCM embedded in metal foam supplied with constant heat flux. Good agreement between experimental and numerical results has been found with a mean PCM local temperature deviation of 1.62K and 2.97K in two locations. The CFD simulation time was 56 hours for 6.5 hours of flow time. A computationally efficient resistance capacitance-based model (RCM) was developed to improve simulation speed. The proposed RCM exhibited mean local temperature deviations of 1.86K and 2.96K when compared against the experimental data for two thermocouple positions, however, it was approximately 2.5x10 5 times faster than CFD. The charging time deviation was less than 1% compared to CFD, and no significant change in thermal energy stored was observed since the temperature differences were small enough to result in insignificant sensible heat deviation. A simulation cost-effectiveness index (CEI) considering accuracy and computational affordability was introduced; the CEI of the RCM solver is 10 3 times better compared to CFD for the prediction of local PCM temperature.

25 ENERGY STORAGE↗

Topography, surface properties, and tectonic evolution

Differences in atmospheric composition, atmospheric and lithospheric temperature, and perhaps mantle composition, suggest that the rock cycle on Venus is not similar to the earth's. While radar data are not consistent with a thick, widespread and porous regolith like that of the moon, wind-transported regolith could be cemented into sedimentary rock that would be indistinguishable from other rocks in radar returns. The elevation spectrum of Venus is strongly unimodal, in contrast to the earth. Most topographic features of Venus remain enigmatic. Two types of tectonic model are proposed: a lithosphere too thick or buoyant to participate in convective flow, and a lithosphere which, in participating in convective flow, implies the existence of plate tectonics. Features consistent with earth-like plate tectonics have not been recognized.

Mcgill, G. E.↗

Water production for coffee brewing by electrodeionization

A resin-wafer electrodeionization (RW-EDI) apparatus for purifying water for coffee brewing comprises a cathode; an anode; and multiple porous solid resin wafer exchange units arranged in a stack between the cathode and the anode, and an air distributor adapted and arranged to aerate the water to be purified. Each unit comprises a monovalent cation exchange membrane (CEM), an anion exchange membrane (AEM), and an ion exchange resin wafer between the CEM and the AEM, which is in contact with, and in fluid flow connection with the CEM and AEM. Each resin wafer comprises a cation exchange resin and an anion exchange resin. The units are oriented with the CEM facing the cathode and the AEM facing the anode, with space between the units defining ion concentrate chambers. Bipolar ion exchange membranes separate the anode and cathode from their nearest resin wafer exchange units.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

From Rockets to Racecars

NASA s Langley Research Center scientists developed a family of catalysts for low- temperature oxidation of carbon monoxide and other gases. The catalysts provide oxidation of both carbon monoxide and formaldehyde at room temperature without requiring any energy input, just a suitable flow of gas through them. Originally designed as part of an atmospheric satellite project, where the catalysts were intended to recycle and recapture carbon dioxide to enhance the operational life of carbon dioxide lasers, the entire system was made to be rugged, long-lived, and fail-safe. The low-temperature oxidation catalysts can be produced and coated onto various catalyst supports, including porous ceramic monoliths and beads, which means that they can be integrated into existing designs, made to fit in limited space, and fashioned into a variety of geometrically different products. Although the satellite project was never launched, the resulting catalysts are doing great things here on Earth, with current applications in the high-speed motor sports arena as air purifiers, so professional racecar drivers do not get carbon monoxide poisoning. Future benefits may extend even further.

Source record↗

Methane foam performance evaluation in water-wet unconsolidated porous media: A systematic experimental investigation at elevated pressure and temperature conditions

In the petroleum industry, enhanced oil recovery (EOR) techniques employ foam extensively to establish conformance control in heterogeneous and fractured reservoirs in order to increase the sweep efficiency. In such applications, foam performance evaluation under complex subsurface conditions is pivotal for the effective and optimized deployment of foam treatment. However, there is a scarcity of hydrocarbon gas foam generation and evaluation studies that examine the relationships between foam performance and the critical foam parameters at high-pressure and high-temperature conditions. Here, this study aims at methodically investigating the effects of several foam parameters on methane foam performance in water-wet proppant packs under harsh operating conditions. This is in relation to the technical needs of hydrocarbon foam injection into hydraulically-induced, propped fractures in unconventional oil reservoirs. To this end, a state-of-the-art experimental foam generation apparatus was designed, fabricated, and commissioned. We performed a large number of foam flow experiments on proppant packs using methane gas and different foaming agents at 3500 psi and 115°C. Anionic and amphoteric surfactants were employed to probe the effect of their ionic nature on foam performance. Foam performance sensitivities to various foam generation parameters and operating conditions, such as surfactant concentration, gas fraction, total injection rate, operating pressure, salinity, and proppant pack length were investigated. To this end, steady-state pressure drops across the proppant packs during foam generation and foam's apparent viscosity were measured to quantify the foam performance of surfactants. The results were then analyzed to determine optimum values of the foam parameters and the interplay between these parameters are discussed here. The systematic results achieved from this work are in agreement with the trends available in the literature and provide new insights into complexities of in situ foam generation in water-wet, unconsolidated porous media at extreme reservoir conditions.

03 NATURAL GAS↗

Porous plate analog burner study of composite solid propellant flame structure

A porous plate burner system for studying the structure and interaction of diffusion flames from adjacent unlike sources of oxidizer to simulate the behavior of solid propellant flames is presented. The passage of oxidizer gases through ports of determined diameters represents decomposing oxidizer crystals, and are adjustable for various oxidizer/fuel ratio experiments. Tests with air, ethane, oxygen, and oxygen-air mixtures are described, with parameters of flow rate, oxygen/fuel ratio, and pressure. Coarse ports are found to be oxidizer rich, while fine ports are stoichiometric. More heat feedback is found with fine ports, indicating that fine particle propellant systems burn faster unless fuel allocation is such that the reduced temperature overcomes the reduced diffusion length. Further observations on the interactions of flames are reported.

Strand, L. D.↗

SCM overview & the EBR-II shutdown heat removal tests validation.

Pronghorn is an engineering-scale, coarse-mesh, thermal-hydraulics tool for supporting reactor-core simulations of advanced nuclear reactors. Most of the current efforts in Pronghorn have been devoted in developing porous finite-volume capabilities and adapting closure correlations for coarse-mesh thermal-hydraulics modeling. However, for liquid-metal reactors (LMRs) with wire-wrapped fuel pin assemblies, a pin-level thermal-hydraulic resolution is required for most safety case studies (pin rupture, channel blockage, etc.). For this purpose, a new Subchannel application is developed in MOOSE, which affords the required flow field resolution, while still preserving an engineering-scale approach. This new solver can be natively coupled to Pronghorn and other MOOSE objects to enable full-core, multi-physics, multi-scale engineering studies. This presentation presents the main features of the SCM code and demonstrates a validation case based on the EBR-II SHRT tests.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Interfacial engineering via laser ablation for high-performing PEM water electrolysis

A rationalized interfacial design strategy was applied to tailor the porous transport layer (PTL)-catalyst layer (CL) contact and the PTL bulk-phase architecture. Particularly, at the PTL-CL interface, our results reveal that laser ablated sintered titanium power-based PTLs improve electrolyzer performance at both the H2NEW Consortium baseline catalyst loading of 0.4 mgIr cm -2 as well as at the ultra-low catalyst loading of 0.055 mgIr cm -2 . Under ultra-low catalyst loadings, the laser ablated PTL demonstrates maximum reduction of 230 mV compared to the commercial PTL at 4 A cm -2 , and reduces by 68 mV at 3.2 A cm -2 under H2NEW baseline loading. Laser ablation alters the titanium phase at the interface, so it forms more uniform structure like a microporous layer or a backing layer, leading to an increase in the surface area in contact with the catalyst layer while preventing the membrane from deforming into the PTL. Moreover, we reveal that bulk-phase architecture modification of the PTL by ablating patterned pores at the flow field-PTL interface improves mass transport without sacrificing contact at the CL-PTL interface. Overall, laser ablation of the PTL is an effective method to customize interfacial design to enhance proton exchange membrane electrolyzer performance.

08 HYDROGEN↗

Exploratory investigation of the effect of porous surfaces on hypersonic turbulent boundary layers

Four different test surfaces were studied to determine the effect of porous walls on the characteristics of a hypersonic turbulent flat-plate boundary layer. The investigation was an attempt to decrease the surface shear of the boundary layer by transmitting fluctuating pressure energy through the wall and absorbing it in a cavity beneath the wall. Pitot surveys were made at two locations, schlieren photographs of the boundary layer were taken, and hot-wire measurements in the flow above the boundary layer were made to determine whether the surfaces affected the turbulent boundary layer. Neither an increase nor a decrease in surface shear or boundary-layer growth was detected. Tabulations of the pitot data are included.

Watson, R. D.↗

Improved cell for water-vapor electrolysis

Continuous-flow electrolytic cells decompose water vapor in steam and room air into hydrogen and oxygen. Sintered iridium oxide catalytic anode coating yields dissociation rates hundredfold greater than those obtained using platinum black. Cell consists of two mirror-image cells, with dual cathode sandwiched between two anodes. Gas traverses serpentine channels within cell and is dissociated at anode. Oxygen mingles with gas stream, while hydrogen migrates through porous matrix and is liberated as gas at cathode.

Aylward, J. R.↗

Determination of boundary shape of cooled porous region

The shape of a cooled porous wall section is found that will provide a uniform surface temperature, as dictated by material limitations, when the surface is subjected to spatially nonuniform heating. In the analysis, local temperatures and pressures in the porous material are expressed in terms of a potential function. From the imposed thermal conditions, this potential function is governed by the dual constraints of both its value and its normal derivative being specified along the heated surface. The unknown shape of this surface is obtained by meeting these dual conditions. The analytical method uses a generalized conformal mapping procedure that includes a curved boundary. The coolant flow can be compressible or incompressible, and its viscosity can depend on temperature.

Snyder, A.↗

An integrated coupling model for solving multiscale fluid-fluid coupling problems in SAM code

In this study, an integrated coupling method has been developed for solving multiscale fluid-fluid coupling problems in plant-scale safety analysis models in SAM (System Analysis Module) code. In this method, a higher-fidelity multi-dimensional (3D) flow module is used for reactor components of complex flow features (e.g., reactor core) and a lumped parameter one-dimensional (1D) flow module for plant-scale flow loops (e.g., primary loop pipe network), respectively. In this method, the 3D fluid equation/domain and 1D fluid equation/domain are tightly coupled at the residual level and solved simultaneously using the Newton’s method to overcome the convergence issues typically seen in existing approaches like separate domain approach, where the 3D fluid equation and 1D fluid equation are solved separately. Extensive and successful code verifications and demonstrations have been performed for this newly developed method. This new modeling approach significantly simplify the work flow in developing high-fidelity plant-scale safety analysis model, e.g. for pool-type reactors and pebble-bed reactors.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A visco-plastic framework for interface processes in sedimentary reservoir rocks at HPHT conditions

As energy operations face the challenge of reservoirs at ever-increasing depths, modelling the response of reservoir rocks at high pressure and high temperature (HPHT) conditions is a crucial step for successfully unlocking new resources. At these conditions, rocks can experience thermal and pressure sensitivity, as well as admit internal phase changes at the pore-solid interfaces that determine their macroscopic response to external loading. It is therefore expected that constitutive laws of Geomechanics should be enriched to accommodate such effects. In this work, a multi-physics constitutive theory for sedimentary rocks is proposed within the general framework of viscoplasticity. The viscosity of the material is assumed to be a function of the temperature, pore-pressure and energy required to alter the inter-granular interfaces. This energy is expressed through the chemical potentials of the phases involved during processes like chemical dissolution/precipitation of the interfaces or mechanical debonding. The resulting flow law and corresponding stress equilibrium are coupled to the energy and mass conservation laws, constituting a closed system of equations, which is solved using the Finite Element simulator REDBACK. A series of numerical tests for performance and calibration is then successfully performed against different types of reservoir rocks, confining pressures and temperatures (from room temperature to over 800K). Here, we show that the mechanical response of sedimentary porous rocks at strains usually achieved in laboratory testing can be explained by accounting for the interface processes taking place at the cementitious material bonding the grains, a process that can also determine the brittle-to-ductile transition of sedimentary rocks.

58 GEOSCIENCES↗

Gas-Cooled High-Temperature Pebble-Bed Reactor Reference Plant Model

This report details a fully coupled neutronics thermal hydraulics reference plant model for a gas-cooled high-temperature pebble-bed reactor. The multiphysics model is developed on the Nuclear Regulatory Commission's Comprehensive Reactor Analysis Bundle (BlueCRAB) available on the Idaho National Laboratory high performance computer, which natively and seamlessly couples Griffin, Pronghorn, and the BISON MOOSE-based applications. Griffin provides the reactor physics capabilities including depletion to the equilibrium core, k-eigenvalue, adjoint, and transient solutions. Pronghorn solves the porous medium equations for the fluid regions and conduction in the solid regions. BISON solves thermal conduction problems for the average pebble and TRISO in the pebble-bed core thus providing the fuel and moderator spatial fields for each pebble burnup group. The neutronics feedback relies primarily on fuel and moderator temperatures. We present results for the coupled steady state equilibrium core and a protected loss of flow event. Although this model is to be considered prototypical with regard to the capabilities in BlueCRAB, its results are consistent with published work by the Institute of Nuclear and New Energy Technology (INET) in China and other research entities.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High-Speed Cascade Tests of the NACA 65-(12A(sub 10))10 and NACA 65-(12A(sub 2)I(sub 8b))10 Compressor Blade Sections

Two-dimensional porous-well cascade tests of the NACA 65- (l2Al0) 10 and NACA 65-(l2A2I8b)10 blade sections were made at Mach numbers from 0.3 to choking in most cases. Data were obtained at solidities of 1.0 and 1.5 et inlet-air angles of 45 deg. and 60 deg. for both blade sections. With a solid--wall modification to the cascade tunnel, schlieren observations were made of the flow in cascade at a solidity of 1.5 and inlet-air angle of 45 deg. and at a solidity of 1.0 and inlet-air angle of 60 deg. Test results for the NACA 65-(12A10)l0 blade section show t hat the turning angles measured at low speed do not change significantly as the speed increases until the critical Mach number is exceed. Because of increasing separation from the highly cambered trailing-edge region, the turning angles for the NACA 65-(12A2I8b)10 blade section decreased as much as 4 deg. from low speed to critical speed. The high-speed performance of the NACA 65-(12A10)10 and the NACA 65-(12A2I8b)l0 blade sections is largely determined by the passage area distribution. The angle of attack for best operation at high Mach numbers is higher than the design angle of attack selected at low speed to have pressure distributions that are free of peaks.

Dunavant, James C.↗