Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Performance Portability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

NASA Tech Briefs, November 2007

Topics include: Wireless Measurement of Contact and Motion Between Contact Surfaces; Wireless Measurement of Rotation and Displacement Rate; Portable Microleak-Detection System; Free-to-Roll Testing of Airplane Models in Wind Tunnels; Cryogenic Shrouds for Testing Thermal-Insulation Panels; Optoelectronic System Measures Distances to Multiple Targets; Tachometers Derived From a Brushless DC Motor; Algorithm-Based Fault Tolerance for Numerical Subroutines; Computational Support for Technology- Investment Decisions; DSN Resource Scheduling; Distributed Operations Planning; Phase-Oriented Gear Systems; Freeze Tape Casting of Functionally Graded Porous Ceramics; Electrophoretic Deposition on Porous Non- Conductors; Two Devices for Removing Sludge From Bioreactor Wastewater; Portable Unit for Metabolic Analysis; Flash Diffusivity Technique Applied to Individual Fibers; System for Thermal Imaging of Hot Moving Objects; Large Solar-Rejection Filter; Improved Readout Scheme for SQUID-Based Thermometry; Error Rates and Channel Capacities in Multipulse PPM; Two Mathematical Models of Nonlinear Vibrations; Simpler Adaptive Selection of Golomb Power-of- Two Codes; VCO PLL Frequency Synthesizers for Spacecraft Transponders; Wide Tuning Capability for Spacecraft Transponders; Adaptive Deadband Synchronization for a Spacecraft Formation; Analysis of Performance of Stereoscopic-Vision Software; Estimating the Inertia Matrix of a Spacecraft; Spatial Coverage Planning for Exploration Robots; and Increasing the Life of a Xenon-Ion Spacecraft Thruster.

Source record↗

Application of Gaussian Bayes classifier to differentiate chlorine-based chemical agents

The Portable Isotopic Neutron Spectroscopy (PINS) is a commercialized system developed by Idaho National Laboratory (INL) to examine chemical warfare agents (CWA) non-destructively, utilizing Prompt Gamma Neutron Activation Analysis (PGNAA) techniques. The PINS system takes advantage of a high-resolution gamma-ray spectrum from a mechanically-cooled high-purity germanium (HPGe) detector. One of the difficult technical challenges is to discriminate the chlorine-based chemical agents. Especially, CN, CNB, CNS and CG have similar chemical compositions to make it hard to discriminate them with a higher confidence. Current identification algorithms for PINS systems with 252-Cf sources have been improved and updated continuously as more field data became available, and new algorithms was studied to complement the current algorithms by adopting the Gaussian Bayes classifier. These new algorithms were intended to be applied to a subset of chlorine-based chemical agents, and their main goal is discriminate CN, CNB, CNS and CG with their ratios of the chlorine neutron inelastic 1763keV peak to the chlorine thermal neutron capture 1959keV peak, which is referred to as the “Cl i/c” or “clic” ratio in this study. The Cl i/c ratios were assumed to follow Gaussian distributions with the means and the standard deviations unique to their corresponding chemical agents. The prior probabilities of these four chemical agents were optimized with a collection of field data to achieve the best performance in terms of precision or positive predictive value (PPV). Finally, their posterior probabilities as functions of the Cl i/c ratio were implemented in the current version of PINS analysis software in order to be tested with more field data.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Biomass-Derived Polymeric Binders in Silicon Anodes for Battery Energy Storage Applications

The demand for portable electronic devices has increased rapidly during the past decade, and has driven a concordant growth in battery production. Since their development as a commercial energy storage solution in the 1990s, lithium-ion batteries (LIBs) have attracted significant attention in both science and industry due to their long cycle life, high energy density, low self-discharge rate, and high working voltage. Production of LIBs requires large amounts of a polymeric binder – commonly polyvinylidene difluoride (PVDF) – for processing and performance purposes. However, since this material is petrochemically-derived, it is far from “green” or sustainable. On the other hand, polymers and their building blocks are found widely throughout nature and can be renewably sourced from biomass at low cost; therefore, replacing PVDF with biomass-derived binders is a promising approach to reduce the environmental footprint of LIBs. Additionally, polymer binders play a critical role in next-generation battery performance. For instance, silicon (Si) is a promising high-capacity anode material for LIBs because of its high theoretical capacity (4200 mA h g –1 ), low working potential, and high abundance in Earth's crust. However, its huge volume change during charge/discharge tends to result in a shortened cycle life, since conventional binders interact only weakly with silicon's native surface and cannot maintain long-term integrity of the electrode. Naturally derived polymers have found better success in this role due to their high structural advantages. In this review, we summarize recent developments in silicon anode binders derived from various biomass sources, with a focus on polymer properties and their effect on battery performance. Further, we propose various perspectives based on our own assessment of these works, and provide a brief commentary on the future outlook of the field.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Analysis of Thick Sandwich Shells with Embedded Ceramic Tiles

The Composite Armored Vehicle (CAV) is an advanced technology demonstrator of an all-composite ground combat vehicle. The CAV upper hull is made of a tough light-weight S2-glass/epoxy laminate with embedded ceramic tiles that serve as armor. The tiles are bonded to a rubber mat with a carefully selected, highly viscoelastic adhesive. The integration of armor and structure offers an efficient combination of ballistic protection and structural performance. The analysis of this anisotropic construction, with its inherent discontinuous and periodic nature, however, poses several challenges. The present paper describes a shell-based 'element-layering' technique that properly accounts for these effects and for the concentrated transverse shear flexibility in the rubber mat. One of the most important advantages of the element-layering technique over advanced higher-order elements is that it is based on conventional elements. This advantage allows the models to be portable to other structural analysis codes, a prerequisite in a program that involves the computational facilities of several manufacturers and government laboratories. The element-layering technique was implemented into an auto-layering program that automatically transforms a conventional shell model into a multi-layered model. The effects of tile layer homogenization, tile placement patterns, and tile gap size on the analysis results are described.

Davila, Carlos G.↗

Ultrasonic Nondestructive Evaluation Techniques Applied to the Quantitative Characterization of Textile Composite Materials

In this Progress Report, we describe our further development of advanced ultrasonic nondestructive evaluation methods applied to the characterization of anisotropic materials. We present images obtained from experimental measurements of ultrasonic diffraction patterns transmitted through water only and transmitted through water and a thin woven composite. All images of diffraction patterns have been included on the accompanying CD-ROM in the JPEG format and Adobe TM Portable Document Format (PDF), in addition to the inclusion of hardcopies of the images contained in this report. In our previous semi-annual Progress Report (NAG 1-1848, December, 1996), we proposed a simple model to simulate the effect of a thin woven composite on an insonifying ultrasonic pressure field. This initial approach provided an avenue to begin development of a robust measurement method for nondestructive evaluation of anisotropic materials. In this Progress Report, we extend that work by performing experimental measurements on a single layer of a five-harness biaxial woven composite to investigate how a thin, yet architecturally complex, material interacts with the insonifying ultrasonic field. In Section 2 of this Progress Report we describe the experimental arrangement and methods for data acquisition of the ultrasonic diffraction patterns upon transmission through a thin woven composite. We also briefly describe the thin composite specimen investigated. Section 3 details the analysis of the experimental data followed by the experimental results in Section 4. Finally, a discussion of the observations and conclusions is found in Section 5.

Miller, James G.↗

Validation of a Manually Oscillating Chair for In-The-Field Assessment of Dynamic Visual Acuity on Crewmembers Within Hours of Returning from Long-Duration Spaceflight

Due to the deconditioned state of crewmembers in the initial hours after landing, it is safer and more practical to perform a vision test while seated in a chair versus walking on a treadmill. The purpose of this study was to validate the ability of a manually operated oscillating chair to produce the oscillatory frequency and displacement equivalent of walking on a treadmill at a 4 mph pace. A fast Fourier transform (FFT)was performed on the vertical trunk acceleration to compare the peak and spread of the distribution of oscillation frequencies for each oscillating condition. Peak oscillation frequencies achieved with the manual chair were lower and more variable than those of treadmill walking and the automatic chair. This can mostly be attributed to operator fatigue. However, DVA scores across conditions were not significantly different, indicating that the manual chair can provide adequate vertical oscillation frequency and displacement with the added advantage of being portable enough for testing outside a laboratory. Furthermore the automatic chair very closely matches the oscillation frequency of treadmill walking, making it an ideal method for testing DVA in a laboratory setting.

Kreutzberg, G. A.↗

Airborne Visible/Infrared Imaging Spectrometer 3 (AVIRIS-3)

The Airborne Visible/Infrared Imaging Spectrometer 3 (AVIRIS-3) is the third of the NASA AVIRIS spectrometer series and is being developed in parallel with the Compact Wide-swath Imaging Spectrometer II (CWIS-II) for the University of Zurich, Switzerland. The core spectrometer of AVIRIS-3 is a copy of the optically fast, F/1.8 Dyson imaging spectrometer used by the Earth Surface Mineral Dust Source Investigation (EMIT) that is in development and scheduled for launch to the International Space Station (ISS) in 2022. AVIRIS-3 is intended to provide state-of-the-art imaging spectroscopy measurements for NASA science and application through the next decade and beyond. AVIRIS-3 uses the EMIT spectrometer design interfaced with a scaled two mirror telescope enclosed in a portable vacuum vessel to enable measurements from airborne platforms ranging from a Twin Otter to a business jet or a NASA ER-2. AVIRIS-3 is a cryogenic instrument with advanced system control and real-time onboard spectroscopic data processing algorithms evolved from AVIRIS-NG. The spectral range of AVIRIS-3 is 380 to 2500 nm with 7.4 nm sampling. The radiometric range is from 0 to max terrestrial Lambertian radiance with higher signal-to-noise ratio performance than AVIRIS-Classic or AVIRIS-Next Generation. The spatial field-of-view is 39.5 degrees with 0.56 milliradian sampling. This paper describes the design and development of AVIRIS-3 and presents its characteristics in comparison to the previous generation imaging spectrometers.

Helmlinger, Mark↗

Cryogenic optical beam steering for superconducting device calibration

We have developed a calibration system based on a micro-electromechanical systems (MEMS) mirror that is capable of delivering an optical beam over a wavelength range of 180 -- 2000 nm (0.62 -- 6.89 eV) in a sub-Kelvin environment. This portable, integrated system can steer the beam over a $\sim$3 cm $\times$ 3 cm area on the surface of any sensor with a precision of $\sim$100 $μ$m, enabling characterization of device response as a function of position. This fills a critical need in the landscape of calibration tools for sub-Kelvin devices, including those used for dark matter detection and quantum computing. These communities have a shared goal of understanding the impact of ionizing radiation on device performance, which can be pursued with our system. This paper describes the design of the first-generation calibration system and the results from successfully testing its performance at room temperature and 20 mK.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Elucidating the Determinants of Alkali Ionic Conductivity in Oxide and Sulfide Frameworks

The aim of this project is to elucidate the structural and chemical factors determining alkali conductivity in oxide and sulfide frameworks using large scale first principles calculations and topological analysis. The facile conduction of alkali ions in oxide and sulfide host structures is of critical importance in energy storage. Today, the dominant form of energy storage in portable electronics is the rechargeable alkali-ion battery, a device that functions entirely on the basis of the reversible transport of alkali ions. The Li+/Na+ conductivity of a cathode has a direct influence on the rate capability of a Li/Na-ion battery, i.e., the speed at which it can be charged and discharged. Alkali conductivity is arguably of even greater importance in the solid electrolytes currently being investigated for high safety, high energy all-solid-state batteries. The research performed in this project has provided critical new insights into the diffusion mechanisms in state-of-the-art alkali superionic conductors such as Li 7 P 3 S 11 , Li 3 OCl 1-x Br x anti-perovskite, argyrodite Li 6 PS 5 Cl. Two potential novel lithium superionic conductors (Li 3 Y(PS 4 ) 2 and Li 5 PS 4 Cl 2 ) with improved electrochemical stabilities were predicted. We have also conducted in-depth studies into alkali conduction in several important classes of electrodes, including the layered P2 NaMO 2 oxides and the highly promising novel disordered rock salt Li 3+x V 2 O 5 anode for high-rate applications. This project has resulted in more than 10 peer-reviewed articles in highly regarded journals as well as a new open-source software framework (pymatgen-analysis-diffusion) that is widely used by the materials research community for the study of diffusion in materials.

25 ENERGY STORAGE↗

Flexible Foam Protection Materials for Constellation Space Suit Element Portable Life Support Subsystem Packaging Study

This paper discusses the effort in evaluating and selecting a light weight impact protection material for the Constellation Space Suit Element (CSSE) Portable Life Support Subsystem (PLSS) conceptual packaging study. A light weight material capable of holding and protecting the components inside the PLSS is required to demonstrate the viability of the flexible PLSS packaging concept. The material needs to distribute, dissipate, and absorb the impact energy of the PLSS falling on the lunar surface. It must also be very robust and function in the extreme lunar thermal vacuum environment for up to one hundred Extravehicular Activity (EVA) missions. This paper documents the performance requirements for selecting a foam protection material, and the methodologies for evaluating commercial off-the-shelf (COTS) foam protection materials. It also presents the materials properties test results and impact drop test results of the various foam materials evaluated in the study. The findings from this study suggest that a foam based flexible protection system is a viable solution for PLSS packaging. However, additional works are needed to optimize COTS foam properties or to develop a composite foam system that will meet all the performance requirements for the CSSE PLSS flexible packaging.

Tang, Henry H.↗

Functional Near-Infrared Spectroscopy Signals Measure Neuronal Activity in the Cortex

Functional near infrared spectroscopy (fNIRS) is an emerging optical neuroimaging technology that indirectly measures neuronal activity in the cortex via neurovascular coupling. It quantifies hemoglobin concentration ([Hb]) and thus measures the same hemodynamic response as functional magnetic resonance imaging (fMRI), but is portable, non-confining, relatively inexpensive, and is appropriate for long-duration monitoring and use at the bedside. Like fMRI, it is noninvasive and safe for repeated measurements. Patterns of [Hb] changes are used to classify cognitive state. Thus, fNIRS technology offers much potential for application in operational contexts. For instance, the use of fNIRS to detect the mental state of commercial aircraft operators in near real time could allow intelligent flight decks of the future to optimally support human performance in the interest of safety by responding to hazardous mental states of the operator. However, many opportunities remain for improving robustness and reliability. It is desirable to reduce the impact of motion and poor optical coupling of probes to the skin. Such artifacts degrade signal quality and thus cognitive state classification accuracy. Field application calls for further development of algorithms and filters for the automation of bad channel detection and dynamic artifact removal. This work introduces a novel adaptive filter method for automated real-time fNIRS signal quality detection and improvement. The output signal (after filtering) will have had contributions from motion and poor coupling reduced or removed, thus leaving a signal more indicative of changes due to hemodynamic brain activations of interest. Cognitive state classifications based on these signals reflect brain activity more reliably. The filter has been tested successfully with both synthetic and real human subject data, and requires no auxiliary measurement. This method could be implemented as a real-time filtering option or bad channel rejection feature of software used with frequency domain fNIRS instruments for signal acquisition and processing. Use of this method could improve the reliability of any operational or real-world application of fNIRS in which motion is an inherent part of the functional task of interest. Other optical diagnostic techniques (e.g., for NIR medical diagnosis) also may benefit from the reduction of probe motion artifact during any use in which motion avoidance would be impractical or limit usability.

Harrivel, Angela↗

Functional Near-Infrared Spectroscopy Signals Measure Neuronal Activity in the Cortex

Functional near infrared spectroscopy (fNIRS) is an emerging optical neuroimaging technology that indirectly measures neuronal activity in the cortex via neurovascular coupling. It quantifies hemoglobin concentration ([Hb]) and thus measures the same hemodynamic response as functional magnetic resonance imaging (fMRI), but is portable, non-confining, relatively inexpensive, and is appropriate for long-duration monitoring and use at the bedside. Like fMRI, it is noninvasive and safe for repeated measurements. Patterns of [Hb] changes are used to classify cognitive state. Thus, fNIRS technology offers much potential for application in operational contexts. For instance, the use of fNIRS to detect the mental state of commercial aircraft operators in near real time could allow intelligent flight decks of the future to optimally support human performance in the interest of safety by responding to hazardous mental states of the operator. However, many opportunities remain for improving robustness and reliability. It is desirable to reduce the impact of motion and poor optical coupling of probes to the skin. Such artifacts degrade signal quality and thus cognitive state classification accuracy. Field application calls for further development of algorithms and filters for the automation of bad channel detection and dynamic artifact removal. This work introduces a novel adaptive filter method for automated real-time fNIRS signal quality detection and improvement. The output signal (after filtering) will have had contributions from motion and poor coupling reduced or removed, thus leaving a signal more indicative of changes due to hemodynamic brain activations of interest. Cognitive state classifications based on these signals reflect brain activity more reliably. The filter has been tested successfully with both synthetic and real human subject data, and requires no auxiliary measurement. This method could be implemented as a real-time filtering option or bad channel rejection feature of software used with frequency domain fNIRS instruments for signal acquisition and processing. Use of this method could improve the reliability of any operational or real-world application of fNIRS in which motion is an inherent part of the functional task of interest. Other optical diagnostic techniques (e.g., for NIR medical diagnosis) also may benefit from the reduction of probe motion artifact during any use in which motion avoidance would be impractical or limit usability.

Harrivel, Angela↗

Portable, Low-Cost, Column Carbon Dioxide and Methane Measurements for Validating Satellite Observations in Remote Locations

We present a low-cost (~$10K per instrument), portable solution to ground-based validation of satellite observations for difficult to reach locations with precisions of 1 ppm XCO2 and 10 ppb XCH4 for hourly data products. While Total Carbon Column Observing Network (TCCON) is the gold-standard for ground validation, there are locations where a ground column validation data point would be useful but conditions are not conducive to a permanent station. Examples include wetlands, thawing permafrost, the tropics, the Amazon, sub-Saharan Africa, as well as locations without a power grid or with geopolitical conflict. In addition, the low-cost and portability mean a geographical region can be studied in depth with multiple instruments. This passive, sun-pointing instrument is a miniaturized, laser heterodyne radiometer (mini-LHR) that has been under development by our team since 2009. It can be operated either in tandem with AERONET (a global network of 500 instruments that measure aerosol optical depth), or as a stand-alone instrument with a low-cost (~$3K), light-weight sun tracker. One of the main benefits of the mini-LHR is that it can quickly reach remote locations and provide a validation measurement even if there is limited or no infrastructure at the site. The instrument weighs ~10 lbs, fits into a backpack, and is powered by two folding solar panels and a battery pack. In clear conditions, the instrument can be set-up in under an hour. Portability means that mini-LHRs can be easily moved for side-by-side comparisons with other mini-LHRs and with TCCON which simplifies assessing instrument bias as well as accuracy. Like TCCON, the mini-LHR points directly at the sun with a narrow field-of-view and is its insensitivity to cloud and aerosol scattering that is common to nadir-pointing passive satellite approaches. Here we present a collection of sample data sets to demonstrate performance from locations that vary in climate, altitude, solar zenith angle, hours of sun per day, etc., as well as data from side-by-side TCCON comparisons. Retrievals of CO2 and CH4 were completed using the NASA/Goddard's Planetary Spectrum Generator (PSG) that incorporates meteorological inputs from Modern-Era Retrospective analysis for Research and Applications, Version 2 (MERRA-2) data set.

Wilson, Emily W.↗

A Novel 24 GHz One-Shot, Rapid and Portable Microwave Imaging System

Development of microwave and millimeter wave imaging systems has received significant attention in the past decade. Signals at these frequencies penetrate inside of dielectric materials and have relatively small wavelengths. Thus. imaging systems at these frequencies can produce images of the dielectric and geometrical distributions of objects. Although there are many different approaches for imaging at these frequencies. they each have their respective advantageous and limiting features (hardware. reconstruction algorithms). One method involves electronically scanning a given spatial domain while recording the coherent scattered field distribution from an object. Consequently. different reconstruction or imaging techniques may be used to produce an image (dielectric distribution and geometrical features) of the object. The ability to perform this accurate~v and fast can lead to the development of a rapid imaging system that can be used in the same manner as a video camera. This paper describes the design of such a system. operating at 2-1 GHz. using modulated scatterer technique applied to 30 resonant slots in a prescribed measurement domain.

Ghasr, M. T.↗

Dynamic Isotope Surface Power Systems

The Dynamic Isotope Power Systems (DIPS) demonstration program, sponsored by the U.S. Department of Energy (DOE) with support funding from the National Aeronautics and Space Administration (NASA), is currently focused on the development of a standardized 2.5 kWe portable generator for multiple applications on the lunar or Martian surface. A variety of potential remote and mobile applications has been identified by NASA including surface rovers for both short and extended duration missions, remote power to science packages, and backup to central base power. Recent work focused on refining the 2.5 kWe design including assessing compatibility with the Martian environment to assure the design is suitable while imposing only a minor mass penalty on lunar operations. Additional work included a study performed to compare the DIPS with regenerative fuel cell systems for lunar mobile and remote power systems. Power requirements were reviewed and a modular system chosen for the comparison. Finally, a plan and cycle schematic were generated for an early demonstration of a prototypic isotope power Brayton system using the Antarctic as the test bed.

Hunt, Maribeth E.↗

Reconstruction for Liquid Argon TPC Neutrino Detectors Using Parallel Architectures.

Neutrinos are particles that interact rarely, so identifying them re-quires large detectors which produce lots of data. Processing this data with thecomputing power available is becoming more dicult as the detectors increasein size to reach their physics goals. In liquid argon time projection chambers(TPCs) the charged particles from neutrino interactions produce ionization elec-trons which drift in an electric field towards a series of collection wires, and thesignal on the wires is used to reconstruct the interaction. The MicroBooNEdetector currently collecting data at Fermilab has 8000 wires, and planned fu-ture experiments like DUNE will have 100 times more, which means that thetime required to reconstruct an event will scale accordingly. Modernization ofliquid argon TPC reconstruction code, including vectorization, parallelizationand code portability to GPUs, will help to mitigate these challenges. The liquidargon TPC hit finding algorithm within theLArSoftframework used acrossmultiple experiments has been vectorized and parallelized. This increases thespeed of the algorithm on the order of ten times within a standalone version onIntel architectures. This new version has been incorporated back intoLArSoftso that it can be generally used. These methods will also be applied to otherlow-level reconstruction algorithms of the wire signals such as the deconvolu-tion. The applications and performance of this modernized liquid argon TPCwire reconstruction will be presented.

Berkman, Sophie↗

The force on the flex: Global parallelism and portability

A parallel programming methodology, called the force, supports the construction of programs to be executed in parallel by an unspecified, but potentially large, number of processes. The methodology was originally developed on a pipelined, shared memory multiprocessor, the Denelcor HEP, and embodies the primitive operations of the force in a set of macros which expand into multiprocessor Fortran code. A small set of primitives is sufficient to write large parallel programs, and the system has been used to produce 10,000 line programs in computational fluid dynamics. The level of complexity of the force primitives is intermediate. It is high enough to mask detailed architectural differences between multiprocessors but low enough to give the user control over performance. The system is being ported to a medium scale multiprocessor, the Flex/32, which is a 20 processor system with a mixture of shared and local memory. Memory organization and the type of processor synchronization supported by the hardware on the two machines lead to some differences in efficient implementations of the force primitives, but the user interface remains the same. An initial implementation was done by retargeting the macros to Flexible Computer Corporation's ConCurrent C language. Subsequently, the macros were caused to directly produce the system calls which form the basis for ConCurrent C. The implementation of the Fortran based system is in step with Flexible Computer Corporations's implementation of a Fortran system in the parallel environment.

Jordan, H. F.↗

Direct recycling of spent nickel-rich cathodes in reciprocal ternary molten salts

Lithium-ion batteries (LIBs) have revolutionized portable electronics and electric vehicles (EVs), but the growing accumulation of end-of-life (EOL) batteries poses environmental challenges. Recycling high-value cathodes from EOL LIBs can minimize waste and reduce the need for mining critical minerals. Here, this study focuses on the direct recycling of Ni-rich cathodes, particularly lithium-manganese-cobalt-oxide (NMC) 622 in a “reciprocal ternary molten salts (RTMS)" system. The ionothermal relithiation in the RTMS system successfully restores the layered structure, lithium content, and electrochemical performance of the NMC 622 cathode, comparable to the pristine material. The cost analysis reveals that cathode regeneration through ionothermal relithiation is more economical than virgin production or conventional recycling methods.

25 ENERGY STORAGE↗