Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Particle accelerator sciences”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

Design of RF Feed System for Standing-Wave Accelerator Structures

We are investigating a standing wave structure with an rf feed to each individual cell. This approach minimizes rf power flow and electromagnetic energy absorbed by an rf breakdown. The objective of this work is a robust high-gradient (above 100 MV/m) X-band accelerator structure.

43 PARTICLE ACCELERATORS↗

Development of a high resolution and high dispersion Thomson parabola

Here, we report on the development of a novel high resolution and high dispersion Thomson parabola for simultaneously resolving protons and low-Z ions of more than 100 MeV/nucleon necessary to explore novel laser ion acceleration schemes. High electric and magnetic fields enable energy resolutions of {Delta}E/E < 5% at 100 MeV/nucleon and impede premature merging of different ion species at low energies on the detector plane. First results from laser driven ion acceleration experiments performed at the Trident Laser Facility demonstrate high resolution and superior species and charge state separation of this novel Thomson parabola for ion energies of more than 30 MeV/nucleon.

43 PARTICLE ACCELERATORS↗

Single-shot beam-position monitor for x-ray free electron laser

We have developed an x-ray beam-position monitor for detecting the radiation properties of an x-ray free electron laser (FEL). It is composed of four PIN photodiodes that detect backscattered x-rays from a semitransparent diamond film placed in the beam path. The signal intensities from the photodiodes are used to compute the beam intensity and position. A proof-of-principle experiment at a synchrotron light source revealed that the error in the beam position is reduced to below 7 {mu}m by using a nanocrystal diamond film prepared by plasma-enhanced chemical vapor deposition. Owing to high dose tolerance and transparency of the diamond film, the monitor is suitable for routine diagnostics of extremely intense x-ray pulses from the FEL.

43 PARTICLE ACCELERATORS↗

High efficiency multichannel collimator for structural studies of liquids and low-Z materials at high pressures and temperatures

A high efficiency multichannel collimator (MCC) device has been developed at the high pressure beamline ID27 of the European Synchrotron Radiation Facility to drastically reduce the x-ray background from the sample environment in the Paris-Edinburgh press. The main technical difficulty, which resides in the minimum slits size achievable using the classical mono-bloc design, has been resolved using an original concept based on a set of independent slits. Then, a very small slit size of 50 {mu}m was manufactured resulting in a great improvement of the signal to background ratio. In addition, the transfer function of the MCC has been measured using the x-ray diffusion signal of a metal doped glass and efficiently applied to correct the raw data. The potential of this new device is illustrated in two challenging examples: iron-sulfur liquid structures and C{sub 60} polymerization process at high pressure and high temperature.

43 PARTICLE ACCELERATORS↗

Spatially resolved measurements of electron cyclotron resonance ion source beam profile characteristics

Simulations predict that the concentric rings and the triangular structures in the profiles of strongly focused ion beams that are found in different experiments should be dominated by ion species with the same or at least similar m/q-ratio. To verify these theoretical predictions we have tuned our ECR ion source to deliver a beam consisting of multiple ion species whose particular m/q-depending focusing ranges from weakly focused to overfocused. We then recorded spatially resolved charge-state distributions of the beam profile at characteristic positions in the plane perpendicular to the beam line. The results validate theoretical predictions and are summarized in this paper. To achieve the required beam profile characteristics we moved the extraction along the beam line to achieve stronger focusing than by only changing the extraction voltage. To fit the regions of interest of the beam profile into the transmission area of the sector magnet, we steered the beam by moving the extraction in the plane perpendicular to the beam axis. The results of both investigations, beam focusing and beam steering by using a 3D-movable extraction, are also reported in this paper. A brief overview of the new beam monitor extensively used during these measurements, the Faraday cup array, is also given.

43 PARTICLE ACCELERATORS↗

A Mott polarimeter operating at MeV electron beam energies

We have developed a Mott electron polarimeter for the Mainzer microtron (MAMI) accelerator in Mainz, Germany. At beam energies ranging between 1.0 and 3.5 MeV two double focusing magnet spectrometers collect elastically backscattered electrons from gold targets. In spite of the small spectrometer acceptance, a sufficient statistical efficiency is achieved to provide very fast measurements if beam currents typical for experiments at MAMI are being used. High reproducibility is achieved, demonstrating that the results of asymmetry measurements are independent of the primary beam current in a range from 0.004 to 45 {mu}A at a level of <1% relative variation. Compared to low energy polarimeters of similar construction an improvement of a factor 2-3 in absolute accuracy seems possible.

43 PARTICLE ACCELERATORS↗

Low power high-performance radio frequency oscillator for driving ion traps

We report a simple, efficient, high voltage radio frequency (RF) generator powered by a single voltage source (1.5-7 V) to resonantly drive ion traps or other capacitive loads. Our circuit is able to deliver RF voltages > 500 V{sub p-p} at frequencies ranging from 0.1 to 10 MHz. This RF oscillator uses low-cost, commercially available components, and can be easily assembled onto a circuit board of a few cm{sup 2}. Because of its simplicity and good efficiency, this circuit is useful in applications requiring small size and low power consumption such as portable ion trap systems where the duration of operation under battery power is of concern.

43 PARTICLE ACCELERATORS↗

Virtual boundary element method for multistage depressed collector of traveling-wave tubes

In this study, virtual boundary element (VBE) method has been employed in multistage depressed collector (MDC) simulation for high efficiency traveling-wave tubes (TWTs). The basic idea of this method is establishing a mapping relation between the source on the real and virtual boundaries. When calculating the potential of the problem field, the virtual source on virtual boundary is only used, instead of the source on real boundary. We discussed the distance between the virtual and real boundaries and the discrete density of virtual boundary, which are closely related to the calculation accuracy. Based on the VBE method, a new computer aided design code CCAD is developed for the MDC system of high efficiency TWT. The results of simulations performed on an axisymmetric four-stage depressed collector are reported. The advantages of VBE method mainly lie in fast calculation and accurate solution. This is of benefit to designing high efficiency MDC thus developing high efficiency TWT, especially for space TWT.

43 PARTICLE ACCELERATORS↗

Multipurpose modular experimental station for the DiProI beamline of Fermi-Elettra free electron laser

We present a compact modular apparatus with a flexible design that will be operated at the DiProI beamline of the Fermi-Elettra free electron laser (FEL) for performing static and time-resolved coherent diffraction imaging experiments, taking advantage of the full coherence and variable polarization of the short seeded FEL pulses. The apparatus has been assembled and the potential of the experimental setup is demonstrated by commissioning tests with coherent synchrotron radiation. This multipurpose experimental station will be open to general users after installation at the Fermi-Elettra free electron laser in 2011.

43 PARTICLE ACCELERATORS↗

Two-screen single-shot electron spectrometer for laser wakefield accelerated electron beams

The laser wakefield acceleration electron beams can essentially deviate from the axis of the system, which distinguishes them greatly from beams of conventional accelerators. In case of energy measurements by means of a permanent-magnet electron spectrometer, the deviation angle can affect accuracy, especially for high energies. A two-screen single-shot electron spectrometer that correctly allows for variations of the angle of entry is considered. The spectrometer design enables enhancing accuracy of measuring narrow electron beams significantly as compared to a one-screen spectrometer with analogous magnetic field, size, and angular acceptance.

43 PARTICLE ACCELERATORS↗

Enhanced High Resolution RBS System

Improvements in full spectrum resolution with the second NEC high resolution RBS system are summarized. Results for 50 A ring TiN/HfO films on Si yielding energy resolution on the order of 1 keV are also presented. Detector enhancements include improved pulse processing electronics, upgraded shielding for the MCP/RAE detector, and reduced noise generated from pumping. Energy resolution measurements on spectra front edge coupled with calculations using 0.4mStr solid angle show that beam energy spread at 400 KeV from the Pelletron registered accelerator is less than 100 eV. To improve user throughput, magnet control has been added to the automatic data collection. Depth profiles derived from experimental data are discussed. For the thin films profiled, depth resolutions were on the Angstrom level with the non-linear energy/channel conversions ranging from 100 to 200 eV.

43 PARTICLE ACCELERATORS↗

Performance of the Argonne National Laboratory electron cyclotron resonance charge breeder

An electron cyclotron resonance charge breeder for the Californium rare ion breeder upgrade (CARIBU), a new radioactive beam facility for the Argonne Tandem Linac Accelerator System (ATLAS), has been constructed and commissioned. Charge breeding efficiencies up to 15.6% have been realized for stable beams with a typical breeding time of 10 ms/charge state. The CARIBU system has been undergoing commissioning tests utilizing a 100 mCi {sup 252}Cf fission source. A charge breeding efficiency of 14.8 {+-} 5% has been achieved for the first radioactive beam of {sup 143}Cs{sup 27+}.

43 PARTICLE ACCELERATORS↗

Characteristics of a symmetrical Cockcroft-Walton power supply of 50 Hz 1.2 MV/50 mA

A 1.2 MV/50 mA symmetrical Cockcroft-Walton (SCW) power supply of over 83% power efficiency, driven by 50 Hz frequency, was developed for an industrial electron beam irradiator. It is constructed by capacitors of 45 nF and 28.13 nF in the coupling column and capacitors of 18.75 nF in the smoothing column. Working status of the rectifier in high power output condition was analyzed, and the conduction angle of the rectifier was calculated. The power factor (PF) of the SCW circuit has been studied, and the equivalent condensance of the circuit has been derived. Measurements were done for the PF compensation. The surge impact during the short circuit transient process was considered in choosing the protection resistance. Test results showed that design specifications of the power supply were achieved, with the non-load voltage being up to 1.32 MV and the ratio of ripple voltage to output voltage as 9.4%.

43 PARTICLE ACCELERATORS↗

On the implementation of computed laminography using synchrotron radiation

Hard x rays from a synchrotron source are used in this implementation of computed laminography for three-dimensional (3D) imaging of flat, laterally extended objects. Due to outstanding properties of synchrotron light, high spatial resolution down to the micrometer scale can be attained, even for specimens having lateral dimensions of several decimeters. Operating either with a monochromatic or with a white synchrotron beam, the method can be optimized to attain high sensitivity or considerable inspection throughput in synchrotron user and small-batch industrial experiments. The article describes the details of experimental setups, alignment procedures, and the underlying reconstruction principles. Imaging of interconnections in flip-chip and wire-bonded devices illustrates the peculiarities of the method compared to its alternatives and demonstrates the wide application potential for the 3D inspection and quality assessment in microsystem technology.

43 PARTICLE ACCELERATORS↗

Simulations of slow positron production using a low-energy electron accelerator

Monte Carlo simulations of slow positron production via energetic electron interaction with a solid target have been performed. The aim of the simulations was to determine the expected slow positron beam intensity from a low-energy, high-current electron accelerator. By simulating (a) the fast positron production from a tantalum electron-positron converter and (b) the positron depth deposition profile in a tungsten moderator, the slow positron production probability per incident electron was estimated. Normalizing the calculated result to the measured slow positron yield at the present AIST linear accelerator, the expected slow positron yield as a function of energy was determined. For an electron beam energy of 5 MeV (10 MeV) and current 240 {mu}A (30 {mu}A), production of a slow positron beam of intensity 5 x 10{sup 6} s{sup -1} is predicted. The simulation also calculates the average energy deposited in the converter per electron, allowing an estimate of the beam heating at a given electron energy and current. For low-energy, high-current operation the maximum obtainable positron beam intensity will be limited by this beam heating.

43 PARTICLE ACCELERATORS↗

Five-element Johann-type x-ray emission spectrometer with a single-photon-counting pixel detector

A Johann-type spectrometer with five spherically bent crystals and a pixel detector was constructed for a range of hard x-ray photon-in photon-out synchrotron techniques, covering a Bragg-angle range of 60 deg. - 88 deg. The spectrometer provides a sub emission line width energy resolution from sub-eV to a few eV and precise energy calibration, better than 1.5 eV for the full range of Bragg angles. The use of a pixel detector allows fast and easy optimization of the signal-to-background ratio. A concentration detection limit below 0.4 wt% was reached at the Cu K{alpha}{sub 1} line. The spectrometer is designed as a modular mobile device for easy integration in a multi-purpose hard x-ray synchrotron beamline, such as the SuperXAS beamline at the Swiss Light Source.

43 PARTICLE ACCELERATORS↗

A high voltage pulsed power supply for capillary discharge waveguide applications

We present an all solid-state, high voltage pulsed power supply for inducing stable plasma formation (density {approx}10{sup 18} cm{sup -3}) in gas-filled capillary discharge waveguides. The pulser (pulse duration of 1 {mu}s) is based on transistor switching and wound transmission line transformer technology. For a capillary of length 40 mm and diameter 265 {mu}m and gas backing pressure of 100 mbar, a fast voltage pulse risetime of 95 ns initiates breakdown at 13 kV along the capillary. A peak current of {approx}280 A indicates near complete ionization, and the r.m.s. temporal jitter in the current pulse is only 4 ns. Temporally stable plasma formation is crucial for deploying capillary waveguides as plasma channels in laser-plasma interaction experiments, such as the laser wakefield accelerator.

43 PARTICLE ACCELERATORS↗

The double electrostatic ion ring experiment: A unique cryogenic electrostatic storage ring for merged ion-beams studies

We describe the design of a novel type of storage device currently under construction at Stockholm University, Sweden, using purely electrostatic focussing and deflection elements, in which ion beams of opposite charges are confined under extreme high vacuum cryogenic conditions in separate ''rings'' and merged over a common straight section. The construction of this double electrostatic ion ring experiment uniquely allows for studies of interactions between cations and anions at low and well-defined internal temperatures and centre-of-mass collision energies down to about 10 K and 10 meV, respectively. Position sensitive multi-hit detector systems have been extensively tested and proven to work in cryogenic environments and these will be used to measure correlations between reaction products in, for example, electron-transfer processes. The technical advantages of using purely electrostatic ion storage devices over magnetic ones are many, but the most relevant are: electrostatic elements which are more compact and easier to construct; remanent fields, hysteresis, and eddy-currents, which are of concern in magnetic devices, are no longer relevant; and electrical fields required to control the orbit of the ions are not only much easier to create and control than the corresponding magnetic fields, they also set no upper mass limit on the ions that can be stored. These technical differences are a boon to new areas of fundamental experimental research, not only in atomic and molecular physics but also in the boundaries of these fields with chemistry and biology. For examples, studies of interactions with internally cold molecular ions will be particular useful for applications in astrophysics, while studies of solvated ionic clusters will be of relevance to aeronomy and biology.

43 PARTICLE ACCELERATORS↗