Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

Ultrabroad-band x-ray source using a picosecond, laser-driven plasma accelerator

An ultrabroad-band x-ray source, with photon energies from 10 keV to >1 MeV, based on a picosecond laser-driven plasma accelerator, is characterized and used to radiograph high-energy-density-science relevant targets. The measured yield of 10 12 photons/shot is reaching the necessary photon yields to radiograph, in a single shot, high areal density objects and matter under extreme conditions. By focusing a short laser pulse (120 J, 1 ps) into a gas jet, a < 100 mrad electron beam with energies up to 350 MeV and up to 70 nC of charge was produced by a combination of laser self-modulation instability and direct laser acceleration. A foil placed at the exit of the gas jet is used to convert part of the electron beam energy into x rays through inverse bremsstrahlung and/or inverse Compton scattering, generating a bright, broad-band, high-photon-energy beam. This beam is used to radiograph a gold half hohlraum with a high-density sphere inside with relevant characteristics for high-energy-density science and inertial confinement fusion.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Collapse of Nuclear Collectivity along the 𝑁 = 𝑍 Line

The lifetime of the 𝐽 𝜋 = 2 + state in the self-conjugate 88 Ru nucleus has been determined in an experiment performed using rare-isotope beams provided by the new Facility for Rare Isotope Beams. This is the heaviest 𝑁 = 𝑍 nucleus for which such a measurement has been achieved. 88 Ru was populated by both one-neutron knockout and charge-exchange reactions, and the lifetime of 14.3$^{+2.5}_{−3.4}$ ps was determined using the triple-foil plunger technique. The extracted electromagnetic transition strength shows that the quadrupole collectivity has dropped significantly compared with the highly deformed 𝑁 = 𝑍 region around 𝐴 ∼ 80. These results are compared with state-of-the-art large-scale shell-model and discrete nonorthogonal shell-model calculations. The theoretical calculations indicate a moderate triaxial deformation and suggest that low-lying states in this nucleus are no longer dominated by strong many-particle many-hole excitations, unlike the lighter, highly deformed 𝑁 = 𝑍 nuclei nearby.

59 ≤ A ≤ 89↗

Precision measurement of the $Ξ^0_b$ baryon lifetime

A sample of 𝑝⁢𝑝 collision data, corresponding to an integrated luminosity of 5.4 fb −1 and collected by the LHCb experiment during LHC Run 2, is used to measure the ratio of the lifetime of the $Ξ^0_b$ baryon to that of the $Λ^0_b$ baryon, 𝑟 𝜏 $≡$ $𝜏_{Ξ^0_b}$$/𝜏_{Λ^0_b}$. The value 𝑟$^{\textrm{Run 2}}_𝜏$ =1.004 ± 0.009 ± 0.006 is obtained, where the first uncertainty is statistical and the second systematic. This value is averaged with the corresponding value from Run 1 to obtain 𝑟 𝜏 =1.004 ± 0.008 ± 0.005. Multiplying by the known value of the $Λ^0_b$ lifetime yields $𝜏_{Ξ^0_b}$ = 1.475 ± 0.012 ± 0.008 ± 0.009 ps, where the last uncertainty is due to the limited knowledge of the $Λ^0_b$ lifetime. This measurement improves the precision of the current world average of the $Ξ^0_b$ lifetime by about a factor of two, and is in good agreement with the most recent theoretical predictions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Quantum imaging with positronium-decay-emitted gamma rays

The use of entangled gamma rays from positronium decay for quantum-enhanced imaging of dense materials is demonstrated. Quantum ghost images, where only one of the entangled 511-keV photons interacts with the object, are obtained for tantalum samples of varying density using a 210-ps time-resolution dual detector system and a Na-22 positron source. An analysis comparing both classical and quantum imaging modalities is employed to isolate true 511-keV events from background noise. Image quality is quantitatively assessed using transmission ratios and the Michelson contrast. Quantum-correlated images are found to exhibit superior (up to approximately 1.7x, from 0.49 to 0.83 in the thickest sample measured) contrast compared to classical methods and align well with theoretical expectations. These results suggest that quantum ghost imaging with positronium-based entangled gamma rays could significantly enhance noninvasive imaging of high-density objects, with potential applications in areas such as cargo inspection and security screening.

36 MATERIALS SCIENCE↗

Search for displaced leptons in $\sqrt{𝑠}$ =13 TeV and 13.6 TeV 𝑝⁢𝑝 collisions with the ATLAS detector

A search for leptons displaced from the primary vertex is performed with the ATLAS detector at the Large Hadron Collider. The search includes the full proton-proton collision dataset collected during Run 2 at $\sqrt{𝑠}$ = 13 TeV and a partial dataset collected during Run 3 in 2022–2023 at $\sqrt{𝑠}$ = 13.6 TeV, corresponding to integrated luminosities of 140 fb −1 and 56.3 fb −1 , respectively. Final states with displaced electrons or muons are considered, and novel triggers introduced in Run 3 are employed that use large impact parameter tracking to reconstruct displaced tracks with low momentum. In addition, photon reconstruction and multivariate techniques are employed to broaden the sensitivity to channels with large background rates or highly displaced electrons, respectively. The results are consistent with the Standard Model background expectations and are used to set model-independent limits on the production of displaced electrons and muons. The analysis is also interpreted in the context of a gauge-mediated supersymmetry breaking model with pair-produced long-lived sleptons and a dark sector model with pair-produced chargino-like states. The results include 95% confidence level exclusions of selectrons with lifetimes from 4 ps to 60 ns and a mass of 150 GeV, and exclusions of selectrons, smuons, and staus with a lifetime of 0.3 ns for masses up to 740, 830, and 440 GeV, respectively. Dark charginos with masses up to 380 GeV are excluded for a mass difference with the neutral state of 40 GeV, and mass differences down to 17 GeV are excluded for dark charginos with a 100 GeV mass.

supersymmetric models↗

Picosecond lifetime measurements of resonances using a thick-target invariant-mass technique

Here, a new technique is presented for measuring the half-lives of resonances in the picosecond range using presently available invariant-mass apparatus and a thick target. For short-lived resonances, the energy losses of the decay fragments in the target material change their relative velocities giving rise to a poor invariant-mass resolution. However, for longer-lived resonances that travel through the remaining target material before decaying outside of the target, this dominant contribution to the resolution is eliminated. The measured invariant-mass peak will then display a narrow peak from these events which sits on a wider structure associated with the remaining events that decay in the target. The fraction of the events in the narrow peak is related to the probability that the resonance leaves the target before decaying and hence is related to the lifetime. This technique is exercised for the 2.685-MeV resonance in 33 Cl which decays by emitting an f -wave proton. A half-life of T 1/2 =5.7$^{+4.1}_{-2.5}$ ps was measured which is consistent with values inferred from other known properties of this resonance.

lifetimes & widths↗

`Pink'-beam X-ray powder diffraction profile and its use in Rietveld refinement

The powder diffraction profile obtained with a pink-beam synchrotron X-ray source is described as the convolution of a back-to-back pair of exponentials convoluted with the Gaussian and Lorentzian components of a pseudo-Voigt. We report this new function is employed for the first time in a Rietveld refinement using data collected from a single 100 ps synchrotron X-ray micropulse.

36 MATERIALS SCIENCE↗

Time-of-flight modulated intensity small-angle neutron scattering measurement of the self-diffusion constant of water

We report that the modulated intensity by zero effort small-angle neutron scattering (MI-SANS) technique is used to measure scattering with a high energy resolution on samples normally ill-suited for neutron resonance spin echo. The self-diffusion constant of water is measured over a q–t range of 0.01–0.2 Å -1 and 70–500 ps. In addition to demonstrating the methodology of using time-of-flight MI-SANS instruments to observe diffusion in liquids, the results support previous measurements on water performed with different methods. This polarized neutron technique simultaneously measures the intermediate scattering function for a wide range of time and length scales. Two radio frequency flippers were used in a spin-echo setup with a 100 kHz frequency difference in order to create a high-resolution time measurement. The results are compared with self-diffusion measurements made by other techniques and the general applicability of MI-SANS at a pulsed source is assessed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Emergence of liquid following laser melting of gold thin films

X-ray structural science is undergoing a revolution driven by the emergence of X-ray Free-electron Laser (XFEL) facilities. The structures of crystalline solids can now be studied on the picosecond time scale relevant to phonons, atomic vibrations which travel at acoustic velocities. In the work presented here, X-ray diffuse scattering is employed to characterize the time dependence of the liquid phase emerging from femtosecond laser-induced melting of polycrystalline gold thin films using an XFEL. In a previous analysis of Bragg peak profiles, we showed the supersonic disappearance of the solid phase and presented a model of pumped hot electrons carrying energy from the gold surface to scatter at internal grain boundaries. This generates melt fronts propagating relatively slowly into the crystal grains. By conversion of diffuse scattering to a partial X-ray pair distribution function, we demonstrate that it has the characteristic shape obtained by Fourier transformation of the measured F ( Q ). The diffuse signal fraction increases with a characteristic rise-time of 13 ps, roughly independent of the incident pump fluence and consequent final liquid fraction. This suggests the role of further melt-front nucleation processes beyond grain boundaries.

36 MATERIALS SCIENCE↗

Analysis of High Frequency AC Link Isolated Three Port Resonant Converter for UAV Applications

A high frequency AC link isolated three port semi-bridgeless resonant converter is analyzed for unmanned aerial vehicle (UAV) applications in this study. The proposed topology is established by replacing rectifier lover diodes with synchronous switches. A phase shifted pulse width modulation (PS-PWM) technique adjusts bi-directional power flow between ports. Proposed control technique provides high efficiency by reducing switching losses with zero voltage switching (ZVS) and zero current switching (ZCS) in a wide power range regulation. Compared to integrated PWM converters in a bi-directional mode, the proposed topology reduces the number of converter stages and allows centralized control at high operating frequency. Theoretical and experimental results demonstrate the feasibility and effectiveness of the proposed converter at a full power of 500 W in laboratory conditions.

Asa, Erdem↗

Analysis of Double-Output CLL Resonant Converter for All-Electric UAV Applications

This paper presents a double-output resonant converter with high-frequency isolation for unmanned aerial vehicle (UAV) applications. The proposed topology is developed by using a full-bridge resonant inverter and double-output half-bridge active rectifiers. For the control system, a phase-shifted pulse width modulation (PS-PWM) method is utilized to adjusts the power flow among the output rectifiers in a wide voltage range regulation with a central control. The theoretical analysis of the converter is explored using the system model under different load conditions with constant frequency. The proposed system is validated with experimental results using 60 V input source and generating 0 - 100 V in each output at a full power of 500 W with 96% maximum efficiency in the laboratory experimental setup.

Asa, Erdem↗

Picosecond Synchronization System for Quantum Networks

The operation of long-distance quantum networks requires photons to be synchronized and must account for length variations of quantum channels. We demonstrate a 200 MHz clock-rate fiber optic-based telecommunication C-band quantum network using off-the-shelf components combined with custom-made electronics. The network is backed by a scalable and fully automated synchronization system with ps-scale timing resolution. Synchronization of the photons is achieved by distributing O-band-wavelength laser pulses between network nodes. Specifically, we distribute photon pairs between three nodes, and measure a reduction of coincidence-to-accidental ratio from 77 to only 42 when the synchronization system is enabled, which permits high-fidelity qubit transmission. Our demonstration sheds light on the role of noise in quantum communication and represents a key step in realizing deployed co-existing classical-quantum networks.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Boosting the External Quantum Efficiency of AlGaN-Based Metal–Semiconductor–Metal Ultraviolet Photodiodes by Electrode Geometry Variation

Fast aluminum-gallium-nitride–based metal–semiconductor–metal ultraviolet photodiodes were successfully designed, fabricated, and characterized using conventional photolithography techniques. Various electrode geometries were fabricated to investigate the influence of metal contact shapes on the device performance indices with emphasis on the response speed and bias-voltage–independent efficiency. Furthermore, based on the independently measured Hall mobility and electric field, we evaluated the carrier transit time of the devices as 1.31 ps with bias-voltage–independent external quantum efficiency of 1198% in photoconductive mode at 19.5 V and 70% at 60 V for n -doped and intrinsic devices, respectively.

42 ENGINEERING↗

Entangled Photon Pair Source Demonstrator Using the Quantum Instrumentation Control Kit System

Here, we report the first demonstration of using the Quantum Instrumentation and Control Kit (QICK) system on RFSoC-FPGA technology to drive the electro-optic intensity modulator that generate time-bin entangled photon pairs and to detect the photon signals. With the QICK system, we achieve high levels of performance metrics including coincidence-to-accidental ratio exceeding 150, and entanglement visibility exceeding 95%, consistent with performance metrics achieved using conventional waveform generators. We also demonstrate simultaneous detector readout using the digitization functional of QICK, achieving internal system synchronization time resolution of 3.2 ps. The work reported in this paper represents an explicit demonstration of the feasibility for replacing commercial waveform generators and time taggers with RFSoC-FPGA technology in the operation of a quantum network, representing a cost reduction of more than an order of magnitude.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultra-Fast 4H-SiC LGAD With Etched Termination and Field Plate

The design, fabrication, and demonstration of a novel Silicon Carbide Low Gain Avalanche Detector (4HSiC LGAD), exhibiting an ultra-fast time response and excellent time resolution, are reported. Here, the use of field plates is proposed to suppress the high electric field caused by the negative bevel-etched angle in 4H-SiC LGADs based on TCAD simulations. Experimental measurements confirm that the field plate significantly increases the breakdown voltage of the 4H-SiC LGADs. Gain and time resolution are measured by using the ultraviolet transient current technique (UV-TCT) showing that 4H-SiC LGADs possess excellent timing performance, with a time resolution better than 35 ps for the injected laser signal with single minimum ionizing particle (MIP) charges generation at room temperature. Additionally, the gain suppression effect in a 4H-SiC LGAD is observed for the first time.

43 PARTICLE ACCELERATORS↗

A 32-Channel Cryo-CMOS ASIC for SNSPD Biasing and Readout with Picosecond

Superconducting nanowire single-photon detectors (SNSPD) are a promising technology for particle detection. Although SNSPDs have demonstrated picosecond timing accuracy, scaling up large arrays has proved challenging. In this work, we introduce a 32-channel cryo-CMOS application-specific integrated circuit (ASIC) that can be tightly integrated with SNSPD arrays. The ASIC is designed to operate at a temperature of 4K and can perform up to 32 simultaneous timing measurements with a root-mean-square (RMS) accuracy of 8.0ps. The ASIC includes on-chip circuitry for externally biasing superconducting devices, low-noise amplifiers for reading superconducting devices, high-resolution time-to-digital converters (TDC) for time-tagging events, and serializers for transmitting data to room-temperature electronics. The ASIC is manufactured in a 22nm FDSOI process and occupies an area of 4.0mm x 1.0mm. The performance of the ASIC was verified using custom cryogenic device models internally developed for the 22nm SOI process. Measurement results will be presented at the conference.

Fredenburg, Jeff↗

Characterizing and Modeling the Influence of Geometry on the Performance of Superconducting Nanowire Cryotrons

The scaling of superconducting nanowire detectors to larger arrays is often limited by room-temperature-readout cabling. Cryogenic integrated circuits constructed from nanowire cryotrons, or nanocryotrons, can address this limitation by performing signal processing on chip. In this study, we characterize key performance metrics of the nanocryotron to elucidate its potential as a logical element in cryogenic integrated circuits and develop an electro-thermal model to connect material parameters with device performance. We find that the performance of the nanocryotron depends on the device geometry, and trade-offs are associated with optimizing the gain, jitter, and energy dissipation. Here, we demonstrate that nanocryotrons fabricated on niobium nitride can achieve a grey zone less than 210 nA wide for a 5 ns long input pulse corresponding to a maximum achievable gain of 48 dB, an energy dissipation of less than 20 aJ per operation, and a jitter of less than 60 ps.

Superconductor↗

Information Leakage Analysis using a Co-design-Based Fault Injection Technique on a RISC-V Microprocessor

The RISC-V instruction set architecture open licensing policy has spawned a hive of development activity, making a range of implementations publicly available. The environments in which RISC-V operates have expanded correspondingly, driving the need for a generalized approach to evaluating the reliability of RISC-V implementations under adverse operating conditions or after normal wear-out periods. Fault injection (FI) refers to the process of changing the state of registers or wires, either permanently or momentarily, and then observing execution behavior. The analysis provides insight into the development of countermeasures that protect against the leakage or corruption of sensitive information which might occur because of unexpected execution behavior. In this paper, we develop a hardware-software co-design architecture that enables fast, configurable fault emulation and utilize it for information leakage and data corruption analysis. Modern System-on-chip FPGAs enable building an evaluation platform where control elements run on a processor(s) (PS) simultaneously with the target design running in the programmable logic (PL). Software components of the FI system introduce faults and report execution behavior. A pair of RISC-V FI-instrumented implementations are created and configured to execute the Advanced Encryption Standard and Twister algorithms. Key and plaintext information leakage and degraded pseudo-random sequences are both observed in the output for a subset of the emulated faults.

42 ENGINEERING↗