Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “POSITRON”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

DIFFUSE EMISSION MEASUREMENT WITH THE SPECTROMETER ON INTEGRAL AS AN INDIRECT PROBE OF COSMIC-RAY ELECTRONS AND POSITRONS

Significant advances have been made in the understanding of the diffuse Galactic hard X-ray continuum emission using data from the INTEGRAL observatory. The diffuse hard power-law component seen with the SPectrometer on INTEGRAL (SPI) has been identified with inverse-Compton emission from relativistic (GeV) electrons on the cosmic microwave background and Galactic interstellar radiation field. In the present analysis, SPI data from 2003 to 2009, with a total exposure time of {approx}10{sup 8} s, are used to derive the Galactic ridge hard X-ray spatial distribution and spectrum between 20 keV and 2.4 MeV. Both are consistent with predictions from the GALPROP code. The good agreement between measured and predicted emission from keV to GeV energies suggests that the correct production mechanisms have been identified. We discuss the potential of the SPI data to provide an indirect probe of the interstellar cosmic-ray electron distribution, in particular for energies below a few GeV.

79 ASTRONOMY AND ASTROPHYSICS↗

Electron-positron annihilation into four charged pions and the a{sub 1}{rho}{pi} Lagrangian

The excitation curve of e{sup +}e{sup -} annihilation into four charged pions in the {rho}(770) region is calculated using three existing models with {rho} mesons and pions in intermediate states supplemented by Feynman diagrams with the a{sub 1}(1260){pi} intermediate states. A two-term phenomenological Lagrangian of the a{sub 1}{rho}{pi} interaction is used. The mixing angle is determined by fitting the e{sup +}e{sup -}{yields}{pi}{sup +}{pi}{sup -}{pi}{sup +}{pi}{sup -} cross section data of the Novosibirsk CMD-2 Collaboration and also its combination with the low-energy part of the BABAR Collaboration data. It is shown that the inclusion of the a{sub 1}{pi} intermediate states succeeds in obtaining a good agreement with the data on both cross section and the {rho}{sup 0}{yields}{pi}{sup +}{pi}{sup -}{pi}{sup +}{pi}{sup -} decay width. When moving to energies above 1 GeV, the {rho}(1450) and {rho}(1700) resonances are taken into account to get excellent agreement with the BABAR data over the full energy range up to 4.5 GeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Positrons in cosmic rays from dark matter annihilations for uplifted Higgs regions in the MSSM

We point out that there are regions in the minimal supersymmetric standard model (MSSM) parameter space which successfully provide a dark matter (DM) annihilation explanation for observed e{sup +} excess (e.g., PAMELA), while still remaining in agreement with all other data sets. Such regions (e.g., the uplifted Higgs region) can realize an enhanced neutralino DM annihilation dominantly into leptons via a Breit-Wigner resonance through the CP-odd Higgs channel. Such regions can give the proper thermal relic DM abundance, and the DM annihilation products are compatible with current antiproton and gamma ray observations. This scenario can succeed without introducing any additional degrees of freedom beyond those already in the MSSM.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Hepatotoxic Dose Thresholds by Positron-Emission Tomography After Yttrium-90 Radioembolization of Liver Tumors: A Prospective Single-Arm Observational Study

PurposeTo define a threshold radiation dose to non-tumoral liver from {sup 90}Y radioembolization that results in hepatic toxicity using pair-production PET.Materials and MethodsThis prospective single-arm study enrolled 35 patients undergoing radioembolization. A total of 34 patients (27 with HCC and 7 with liver metastases) were included in the final analysis. Of 27 patients with underlying cirrhosis, 22 and 5 patients were Child–Pugh A and B, respectively. Glass and resin microspheres were used in 32 (94%) and 2 (6%) patients, respectively. Lobar and segmental treatment was done in 26 (76%) and 8 (24%) patients, respectively. Volumetric analysis was performed on post-radioembolization time-of-flight PET imaging to determine non-tumoral parenchymal dose. Hepatic toxicity was evaluated up to 120 days post-treatment, with CTCAE grade ≤ 1 compared to grade ≥ 2.ResultsThe median dose delivered to the non-tumoral liver in the treated lobe was 49 Gy (range 0–133). A total of 15 patients had grade ≤ 1 hepatic toxicity, and 19 patients had grade ≥ 2 toxicity. Patients with a grade ≥ 2 change in composite toxicity (70.7 vs. 43.8 Gy), bilirubin (74.1 vs. 43.3 Gy), albumin (84.2 vs. 43.8 Gy), and AST (94.5 vs. 47.1 Gy) have significantly higher non-tumoral parenchymal doses than those with grade ≤ 1. Liver parenchymal dose and Child–Pugh status predicted grade ≥ 2 toxicity, observed above a dose threshold of 54 Gy.ConclusionIncreasing delivered {sup 90}Y dose to non-tumoral liver measured by internal pair-production PET correlates with post-treatment hepatic toxicity. The likelihood of toxicity exceeds 50% at a dose threshold of 54 Gy.ClinicalTrials.gov identifier: NCT02848638.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Early risk stratification using Rubidium-82 positron emission tomography in STEMI patients

Background: Assessment of infarct size after myocardial infarction is predictive of subsequent morphological changes and clinical outcome. This study aimed to assess subacute post-intervention Rubidium-82 ({sup 82}Rb)-PET imaging in predicting left ventricle ejection fraction, regional wall motion, and final infarct size by CMR at 3-months after STEMI. Methods: STEMI patients undergoing percutaneous coronary intervention were included prospectively. Rest-only {sup 82}Rb-PET perfusion imaging was performed at median 36 hours [IQR: 22 to 50] after the treatment. The extent of hypoperfusion and absolute blood flow (mL·min·g) were estimated on a global and a 17-segment model with dedicated software. At 3-months follow-up patients completed the CMR functional and late gadolinium enhancement imaging. Results: 42 patients were included, but only 35 had follow-up CMR and constituted the study population. Absolute blood flow was significantly lower in the infarct-related territory compared to remote myocardium, P < .005. Extent of hypoperfusion correlated with final infarct size, r = 0.58, P < .001, while blood flow correlated with ejection fraction, r = 0.41, P < .05. In linear mixed models, higher subacute absolute blood flow (β = 4.6, confidence interval [3.5; 5.2], P < .001, R{sup 2} = 0.67) was associated with greater wall motion. Segmental extent of subacute hypoperfusion (β = 0.43 [0.38; 0.49], P < .001, R{sup 2} = 0.58) was associated with the degree of late gadolinium enhancement at 3-months. Conclusions: Subacute rest-only {sup 82}Rb-PET is feasible following STEMI and seems predictive of myocardial function and infarct size at 3-months.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Impact of [{sup 18}F] Fluorodeoxyglucose Positron Emission Tomography on Staging and Management of Early-Stage Follicular Non-Hodgkin Lymphoma

Purpose: Accurate staging is critical to select patients with early-stage (I-II) follicular lymphoma (ESFL) suitable for involved-field radiotherapy (IFRT) and to define the radiotherapy portal. We evaluated the impact of fluorodeoxyglucose (FDG) PET on staging, treatment, and outcome for patients with ESFL on conventional staging. Methods and Materials: Forty-two patients with untreated ESFL (World Health Organization Grade I-IIIa, or 'low grade') following a minimum of physical examination, computerized tomography, and bone marrow examination (conventional assessment) and who had staging PET from June 1997 to June 2006 were studied retrospectively. Stage allocation was based on routine imaging reports. Disease sites, stage, and management plan were recorded based on conventional assessment or conventional assessment plus PET. Results: FDG avidity was demonstrated in 97% of patients in whom disease was evident on conventional assessment after biopsy. PET findings suggested a change of stage or management in 19 patients: 13 (31%) who were upstaged to Stage III-IV, altering ideal management from IFRT to systemic therapy, and 6 (14%) who had the involved field enlarged, including 4 upstaged from Stage I to II. Of these 19 cases, PET findings were considered true positive in 8 patients, indeterminate in 10, and false positive in only 1 patient. Conclusions: Our data confirm that ESFL is usually FDG-avid. In routine practice, PET has the potential to upstage and thereby alter management in a high proportion of patients with apparent ESFL.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Positron Emission Tomography/Computed Tomography in the Staging and Treatment of Anal Cancer

Purpose: This study was intended to determine the role of PET/CT in the staging of anal cancer as a supplement to three-dimensional transanal ultrasound (TAUS) and inguinal ultrasound (US). The impact of the PET/CT on the initial stage and treatment plan proposed by TAUS/US was assessed. Methods and Materials: Ninety-five (95) patients referred to our clinic between July 1, 2005, and December 31, 2009, were retrospectively reviewed. All patients had biopsy-proven primary squamous cell cancer of the anal canal. There were 65 females (68%) and 30 males (32%), and the median age was 58 years (range, 35-88 years). Six (6%) of the patients were HIV positive. All patients were staged with TAUS/US and PET/CT. Results: Twenty-eight (28) patients were diagnosed with suspicious perirectal node metastases. TAUS visualized 24 of these, whereas PET/CT detected 15. Suspicious inguinal nodes were visualized on either US or PET/CT in 41 patients. Seventeen (17) of these had confirmed malignant disease on biopsy, and 15 had confirmed benign disease. All 17 patients (100%) with malignant inguinal nodes were diagnosed by PET/CT, whereas US identified 16 (94%). Ten patients were diagnosed with suspicious inguinal nodes on PET/CT that had not been seen on US. One of these was malignant, three were benign, and six were not biopsied. PET/CT diagnosed eight metastatic sites, whereas TAUS/US diagnosed three. PET/CT discovered three of the five synchronous cancers seen in this study. PET/CT upstaged the disease in 14% of the cases and changed the treatment plan proposed by TAUS/US in 17%. Conclusion: PET/CT has great potential influence on the staging and treatment of anal cancer. TAUS is important in the staging of the primary tumor and N1-stage, whereas PET/CT seems necessary for the N2/3-stage, the M-stage and synchronous cancers.

62 RADIOLOGY AND NUCLEAR MEDICINE↗