Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PLASMA PROBE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

X-Ray Probes of Jupiter's Auroral Zones, Galilean Moons, and the Io Plasma Torus

Remote observations from the Earth orbiting Chandra X-ray Observatory and the XMM-Newton Observatory have shown the the Jovian system is a rich and complex source of x-ray emission. The planet's auroral zones and its disk are powerful sources of x-ray emission, though with different origins. Chandra observations discovered x-ray emission from the Io plasma torus and from the Galilean moons Io, Europa, and possibly Ganymede. The emission from the moons is due to bombardment of their surfaces by highly energetic magnetospheric protons, and oxygen and sulfur ions, producing fluorescent x-ray emission lines from the elements in their surfaces against an intense background continuum. Although very faint when observed from Earth orbit, an imaging x-ray spectrometer in orbit around the icy Galilean moons would provide a detail mapping of the elemental composition in their surfaces. Here we review the results of Chandra and XMM-Newton observations of the Jovian system and describe the characteristics of X-MIME, an imaging x-ray spectrometer undergoing study for possible application to future missions to Jupiter such as JIMO. X-MIME has the ultimate goal of providing detailed high-resolution maps of the elemental abundances of the surfaces of Jupiter's icy moons and Io, as well as detailed study of the x-ray mission from the Io plasma torus, Jupiter's auroral zones, and the planetary disk.

Elsner, R. F.↗

Investigating fusion plasma instabilities in the Mega Amp Spherical Tokamak using mega electron volt proton emissions (invited)

The proton detector (PD) measures 3 MeV proton yield distributions from deuterium-deuterium fusion reactions within the Mega Amp Spherical Tokamak (MAST). The PD’s compact four-channel system of collimated and individually oriented silicon detectors probes different regions of the plasma, detecting protons (with gyro radii large enough to be unconfined) leaving the plasma on curved trajectories during neutral beam injection. From first PD data obtained during plasma operation in 2013, proton production rates (up to several hundred kHz and 1 ms time resolution) during sawtooth events were compared to the corresponding MAST neutron camera data. Fitted proton emission profiles in the poloidal plane demonstrate the capabilities of this new system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The discharge plasma in ion engine neutralizers: Numerical simulations and comparisons with laboratory data

Numerical simulations of neutralizer hollow cathodes at various operating conditions and orifice sizes are presented. The simulations were performed using a two-dimensional axisymmetric model that solves numerically an extensive system of conservation laws for the partially ionized gas in these devices. The results for the plasma are compared directly with Langmuir probe measurements. The computed keeper voltages are also compared with the observed values. Whenever model inputs and/or specific physics of the cathode discharge were uncertain or unknown additional sensitivity calculations have been performed to quantify the uncertainties. The model has also been employed to provide insight into recent ground test observations of the neutralizer cathode in NASA's evolutionary xenon thruster. It is found that a likely cause of the observed keeper voltage drop in a long duration test of the engine is cathode orifice erosion.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Pulse modulated microwave operation on large bore electron cyclotron resonance ion source with cylindrically comb-shaped magnetic fields configuration

In order to enhance efficiency of an electron cyclotron resonance (ECR) plasma for broad and dense ion beam source under the low pressure, the magnetic field configuration is constructed by a pair of comb-shaped magnet which has opposite polarity each other, and which cylindrically surrounds the plasma chamber. By using the pulse microwave mode operation, we aim at generation of plasma with parameters that cannot be achieved at the continuous microwave (cw) mode. The maximum beam current is obtained in the experimental condition of the pulse width 100-200 {mu}s at the duty ratio 40%-50%. According to probe measurements of the ECR plasma, it is found the electron density in the pulse mode is larger than that in the cw mode, while the electron temperatures in the pulse mode were lower than that in the cw mode. These indirect evidences cause to enhance ion beams in the pulse mode operation, and then suggest a spread of operation windows for plasma parameters suitable to production of molecular or cluster ions.

43 PARTICLE ACCELERATORS↗

Detection of signals in the ion cyclotron frequency range at the edge during ICRF heating on ASDEX Upgrade

The ICRF system on ASDEX Upgrade is equipped with an arc detector based on the observation of frequencies between 5 and 25 MHz in the RF feeding line [R1]. On some shots, the detector was triggered in an anomalous way: tenths of detections over several hundreds of milliseconds on detectors of all antennas at the same time [R2]. It was suggested that these frequencies were not excited by arcs but came from the plasma. We installed a RF probe inside the vacuum vessel and connected it to a fast acquisition system. We indeed observed frequencies during ICRF heating of several shots. We present here the features of these frequencies, their possible conditions of existence in terms of plasma and RF parameters (magnetic field, density, temperature, RF frequency, power injected) and we compare the source of these frequencies with known phenomena like ICE, CAE and surface waves.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Comparing simulated and observed EMIC wave amplitudes using in situ Van Allen Probes’ measurements

In this study, we perform a statistical study calculating electromagnetic ion cyclotron (EMIC) wave amplitudes based off in situ plasma measurements taken by the Van Allen Probes’ (1.1–5.8 R e ) Helium, Oxygen, Proton, Electron (HOPE) instrument. Calculated wave amplitudes are compared to EMIC waves observed by the Electric and Magnetic Field Instrument Suite and Integrated Science on board the Van Allen Probes during the same period. The survey covers a 22-month period (1 November 2012 to 31 August 2014), a full Van Allen Probe magnetic local time (MLT) precession. The linear theory proxy was used to identify EMIC wave events with plasma conditions favorable for EMIC wave excitation. Two hundred and thirty-two EMIC wave events (103 H + -band and 129 He + -band) were selected for this comparison. Nearly all events selected are observed beyond L = 4. Results show that calculated wave amplitudes exclusively using the in situ HOPE measurements produce amplitudes too low compared to the observed EMIC wave amplitudes. Hot proton anisotropy (Ahp) distributions are asymmetric in MLT within the inner (L < 7) magnetosphere with peak (minimum) A hp , ~0.81 to 1.00 (~0.62), observed in the dawn (dusk), 0000 < MLT ≤ 1200 (1200 < MLT ≤ 2400), sectors. Measurements of A hp are found to decrease in the presence of EMIC wave activity. A hp amplification factors are determined and vary with respect to EMIC wave-band and MLT. Lastly, He + -band events generally require double (quadruple) the measured A hp for the dawn (dusk) sector to reproduce the observed EMIC wave amplitudes.

58 GEOSCIENCES↗

Transient plasma potential in pulsed dual frequency inductively coupled plasmas and effect of substrate biasing

An electron emitting probe in saturated floating potential mode has been used to investigate the temporal evolution of plasma potential and the effect of substrate RF biasing on it for pulsed dual frequency (2 MHz/13.56 MHz) inductively coupled plasma (ICP) source. The low frequency power (P{sub 2MHz}) has been pulsed at 1 KHz and a duty ratio of 50%, while high frequency power (P{sub 13.56MHz}) has been used in continuous mode. The substrate has been biased with a separate bias power at (P{sub 12.56MHz}) Argon has been used as a discharge gas. During the ICP power pulsing, three distinct regions in a typical plasma potential profile, have been identified as ‘initial overshoot’, pulse ‘on-phase’ and pulse ‘off-phase’. It has been found out that the RF biasing of the substrate significantly modulates the temporal evolution of the plasma potential. During the initial overshoot, plasma potential decreases with increasing RF biasing of the substrate, however it increases with increasing substrate biasing for pulse ‘on-phase’ and ‘off-phase’. An interesting structure in plasma potential profile has also been observed when the substrate bias is applied and its evolution depends upon the magnitude of bias power. The reason of the evolution of this structure may be the ambipolar diffusion of electron and its dependence on bias power.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ion acceleration by laser hole-boring into plasmas

By experiment and simulations, we study the interaction of an intense CO{sub 2} laser pulse with slightly overcritical plasmas of fully ionized helium gas. Transverse optical probing is used to show a recession of the front plasma surface with an initial velocity >10{sup 6} m/s driven by hole-boring by the laser pulse and the resulting radiation pressure driven electrostatic shocks. The collisionless shock propagates through the plasma, dissipates into an ion-acoustic solitary wave, and eventually becomes collisional as it slows further. These observations are supported by PIC simulations which prove the conclusion that monoenergetic protons observed in our earlier reported experiment with a hydrogen jet result from ion trapping and reflection from a shock wave driven through the plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Influence of the radial profile of the electric potential on the confinement of a high-{beta} two-component plasma in a gas-dynamic trap

One of the most important problems to be studied in the gas-dynamic trap (GDT) facility is the investigation of MHD stability and cross-field transport in a plasma with a relatively high value of {beta} = {pi}p/B{sup 2}. Recent experiments demonstrated that the radial electric field produced in the plasma by using radial limiters and coaxial end plasma collectors improves plasma stability in axisymmetric magnetic mirror systems without applying special MHD stabilizers. The experimental data presented in this work show that stable plasma confinement can be achieved by producing a radial potential drop across a narrow region near the plasma boundary. Creating radial electric fields of strength 15-40 V/cm causes a shear plasma flow, thereby substantially increasing the plasma confinement time. When all the radial electrodes were grounded, the confinement was unstable and the plasma confinement time was much shorter than the characteristic time of plasma outflow through the magnetic mirrors. Measurements of cross-field plasma fluxes with the use of a specially designed combined probe show that, in confinement modes with differential plasma rotation, transverse particle losses are negligibly small as compared to longitudinal ones and thus can be ignored. It is also shown that, when the GDT plasma is in electric contact with the radial limiters and end collectors, the growth rate of interchange instability decreases considerably; such a contact, however, does not ensure complete MHD stability when the electrodes are at the same potential.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

External control of electron energy distributions in a dual tandem inductively coupled plasma

The control of electron energy probability functions (EEPFs) in low pressure partially ionized plasmas is typically accomplished through the format of the applied power. For example, through the use of pulse power, the EEPF can be modulated to produce shapes not possible under continuous wave excitation. This technique uses internal control. In this paper, we discuss a method for external control of EEPFs by transport of electrons between separately powered inductively coupled plasmas (ICPs). The reactor incorporates dual ICP sources (main and auxiliary) in a tandem geometry whose plasma volumes are separated by a grid. The auxiliary ICP is continuously powered while the main ICP is pulsed. Langmuir probe measurements of the EEPFs during the afterglow of the main ICP suggests that transport of hot electrons from the auxiliary plasma provided what is effectively an external source of energetic electrons. The tail of the EEPF and bulk electron temperature were then elevated in the afterglow of the main ICP by this external source of power. Results from a computer simulation for the evolution of the EEPFs concur with measured trends.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Plasma cell adaptation to enhance particle acceleration

A plasma study is performed in order to construct a cell for plasma acceleration purpose. As well, a multicell design is introduced for the injection of beam driver application. The suggested idea is experimentally demonstrated for two plasma cell configuration. The preformed plasma is obtained by a symmetrically driven capacitive audio frequency discharge. It is featured by its moderate pressure of 0.1-0.2 Torr, low consumption power of 130 W maximum, low discharge voltage and frequency up to 950 V and 20 kHz, respectively, and high plasma density from 10{sup 11} to 10{sup 15} cm{sup -3}. The electron temperature obtained by Langmuir double probe varies from 1 up to 16 eV. It is observed that the increases of the discharge voltage and frequency enlarge the plasma parameters to their maximum values. The plasma cell filled with different gases demonstrates that the Ar and He gases manifest the highest ionization efficiency exceeding 100% at 950 V and 20 kHz. The formed plasma is cold; its density is uniform and stable along the positive column for long competitive lifetime. Showing that it follows the conditions to enhance particle acceleration and in conjunction with its periphery devices form a plasma cell that could be extended to serve this purpose. Demonstrating that an injected electron beam into the extended preformed plasma could follow, to long distance, a continuous trajectory of uniform density. Such plasma generated by H{sub 2} or Ar gases is suggested to be used, respectively, for low-density or higher density beam driver.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Langmuir Probe Spacecraft Potential End Item Specification Document

This document describes the Langmuir Probe Spacecraft Potential (LPSP) investigation of the plasma environment in the vicinity of the ProSEDS Delta II spacecraft. This investigation will employ a group of three (3) Langmuir Probe Assemblies, LPAs, mounted on the Delta II second stage to measure the electron density and temperature (n(sub e) and T(sub e)), the ion density (n(sub i)), and the spacecraft potential (V(sub s)) relative to the surrounding ionospheric plasma. This document is also intended to define the technical requirements and flight-vehicle installation interfaces for the design, development, assembly, testing, qualification, and operation of the LPSP subsystem for the Propulsive Small Expendable Deployer System (ProSEDS) and its associated Ground Support Equipment (GSE). This document also defines the interfaces between the LPSP instrument and the ProSEDS Delta II spacecraft, as well as the design, fabrication, operation, and other requirements established to meet the mission objectives. The LPSP is the primary measurement instrument designed to characterize the background plasma environment and is a supporting instrument for measuring spacecraft potential of the Delta II vehicle used for the ProSEDS mission. Specifically, the LPSP will use the three LPAs equally spaced around the Delta II body to make measurements of the ambient ionospheric plasma during passive operations to aid in validating existing models of electrodynamic-tether propulsion. These same probes will also be used to measure Delta II spacecraft potential when active operations occur. When the electron emitting plasma contractor is on, dense neutral plasma is emitted. Effective operation of the plasma contactor (PC) will mean a low potential difference between the Delta II second stage and the surrounding plasma and represents one of the voltage parameters needed to fully characterize the electrodynamic-tether closed circuit. Given that the LP already needs to be well away from any near-field disturbances around the Delta II, it is possible to use the same probe with a simple reconfiguration of the electronics to measure potential with respect to the ambient plasma. The LP measurement techniques are outlined in the following text and discussed in detail in the Appendix. The scientific goals of the investigation, the physical and electrical characteristics of the instrument, and the on-orbit measurement requirements are also discussed in this document.

Gilchrist, Brian↗

Time-resolved velocity and ion sound speed measurements from simultaneous bow shock imaging and inductive probe measurements

We present a technique to measure the time-resolved velocity and ion sound speed in magnetized, supersonic high-energy-density plasmas. We place an inductive (“b-dot”) probe in a supersonic pulsed-power-driven plasma flow and measure the magnetic field advected by the plasma. As the magnetic Reynolds number is large (R M > 10), the plasma flow advects a magnetic field proportional to the current at the load. This enables us to estimate the flow velocity as a function of time from the delay between the current at the load and the signal at the probe. The supersonic flow also generates a hydrodynamic bow shock around the probe, the structure of which depends on the upstream sonic Mach number. By imaging the shock around the probe with a Mach–Zehnder interferometer, we determine the upstream Mach number from the shock Mach angle, which we then use to determine the ion sound speed from the known upstream velocity. We use the sound speed to infer the value of Z̄T e , where Z̄ is the average ionization and T e is the electron temperature. We use this diagnostic to measure the time-resolved velocity and sound speed of a supersonic (M S ~ 8), super-Alfvénic (M A ~ 2) aluminum plasma generated during the ablation stage of an exploding wire array on the Magpie generator (1.4 MA, 250 ns). The velocity and Z̄T e measurements agree well with the optical Thompson scattering measurements reported in the literature and with 3D resistive magnetohydrodynamic simulations in GORGON.

47 OTHER INSTRUMENTATION↗

The formation of reverse shocks in magnetized high energy density supersonic plasma flows

A new experimental platform was developed, based on the use of supersonic plasma flow from the ablation stage of an inverse wire array z-pinch, for studies of shocks in magnetized high energy density physics plasmas in a well-defined and diagnosable 1-D interaction geometry. The mechanism of flow generation ensures that the plasma flow (Re{sub M} ∼ 50, M{sub S} ∼ 5, M{sub A} ∼ 8, V{sub flow} ≈ 100 km/s) has a frozen-in magnetic field at a level sufficient to affect shocks formed by its interaction with obstacles. It is found that in addition to the expected accumulation of stagnated plasma in a thin layer at the surface of a planar obstacle, the presence of the magnetic field leads to the formation of an additional detached density jump in the upstream plasma, at a distance of ∼c/ω{sub pi} from the obstacle. Analysis of the data obtained with Thomson scattering, interferometry, and local magnetic probes suggests that the sub-shock develops due to the pile-up of the magnetic flux advected by the plasma flow.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental studies on ion acceleration and stream line detachment in a diverging magnetic field

The flow structure of ions in a diverging magnetic field has been experimentally studied in an electron cyclotron resonance plasma. The flow velocity field of ions has been measured with directional Langmuir probes calibrated with the laser induced fluorescence spectroscopy. For low ion-temperature plasmas, it is concluded that the ion acceleration due to the axial electric field is important compared with that of gas dynamic effect. It has also been found that the detachment of ion stream line from the magnetic field line takes place when the parameter |f{sub ci}L{sub B}/V{sub i}| becomes order unity, where f{sub ci}, L{sub B}, and V{sub i} are the ion cyclotron frequency, the characteristic scale length of magnetic field inhomogeneity, and the ion flow velocity, respectively. In the detachment region, a radial electric field is generated in the plasma and the ions move straight with the ExB rotation driven by the radial electric field.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effects of ion trapping and fluctuations of electron temperature and plasma flow on cross-beam energy transfer

The influences of ion trapping and fluctuations of electron temperature and plasma flow on cross-beam energy transfer (CBET) are examined using two- and three-dimensional particle-in-cell simulations in parameter regimes relevant to recent CBET experiments at the OMEGA laser facility. In mid-Z plasma irradiated by an intense pump beam and weaker probe beam, ion trapping, collisional de-trapping, and plasma flow induced by thermal effects are shown to affect the CBET gain. Ion trapping can enhance or detune the CBET resonance [Nguyen et al., Phys. Plasmas 28, 082705 (2021)]. Collisional de-trapping can affect the CBET gain at low seed beam intensity near the onset threshold for ion trapping. Thermal-effects-induced flow can also detune the CBET resonance at a level comparable to that from trapping at low seed beam intensity. As a consequence, the CBET gain is sensitive to collisions and dimensionality at low seed beam intensity where ion trapping is weak but is insensitive to collisions and dimensionality at high seed beam intensity where ion trapping is strong.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Density Gradient Evolution Effect on Ion Cyclotron Waves Excitation in TUMAN-3M Tokamak Ohmic Discharges

In TUMAN-3M tokamak ohmic hydrogen and deuterium discharges oscillations with ion cyclotron (IC) frequency were detected. Fast magnetic probes poloidal array in TUMAN-3M is capable of detecting several harmonics of IC frequency of main plasma isotope. Fuel pellet injection significantly reduces IC oscillations intensity, though after complete pellet evaporation returns to initial level. IC oscillations localization and excitation conditions are of certain interest. Based on drift-cyclotron instability excitation theory and numerical modeling of scenarios with ohmic LH-transition and pellet-injection plasma parameters (density gradient primarily) effect on IC oscillations excitation was studied.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Thermoelectric-Driven Liquid-Metal Plasma-Facing Structures (TELS) Final Report

The Thermoelectric-Driven Liquid-Metal Plasma-Facing Structures (TELS) project was able to establish the experimental conditions necessary for flowing liquid metal surfaces in order to be utilized as surfaces facing fusion relevant energetic plasma flux. The work has also addressed additional developments along with progressing along the timeline detailed in the proposal. A no-cost extension was requested to conduct other relevant experiment- specifically regarding the characterization droplet ejection during energetic plasma flux impact. A specially designed trench module, which could accommodate trenches with different aspect ratios was fabricated and installed in the TELS setup and plasma gun experiments were performed. Droplet ejection was characterized using high speed image acquisition and also surface mounted probes were used to characterize the plasma. The Gantt chart below had been provided with the original proposal, indicating the tasks to be performed in the third year of funding. These tasks are listed above in the progress report outline, and their progress status is detailed below.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗