Low dimensional metal halide perovskites and hybrids

Organic-inorganic metal halide hybrids are an important class of crystalline materials with exceptional structural and property tunability. Recently metal halide perovskites with ABX 3 structure have been extensively investigated as new generation semiconductors for various optoelectronic devices, including photovoltaic cells, light emitting diodes, photodetectors, and lasers, for their exceptional optical and electronic properties. By controlling the morphological dimensionality, low dimensional metal halide perovskites, including 2D perovskite nanoplatelets, 1D perovskite nanowires, and 0D perovskite quantum dots, have been developed to exhibit distinct properties from their bulk counterparts, due to quantum size effects. Besides ABX 3 perovskites, organic-inorganic metal halide hybrids, containing the same fundamental building block of metal halide octahedra (BX 6 ), can also be assembled to possess other types of crystallographic structures. Using appropriate organic and inorganic components, low dimensional organic-inorganic metal halide hybrids with 2D, quasi-2D, corrugated-2D, 1D, and 0D structures at the molecular level have been developed and studied. Due to the strong quantum confinement and site isolation, these low dimensional metal halide hybrids at the molecular level exhibit remarkable and unique properties that are significantly different from those of ABX 3 perovskites. In light of the rapid development of low dimensional metal halide perovskites and hybrids, it is indeed timely to review the recent progress in these areas. Also, there is a need to clarify the difference between morphological low dimensional metal halide perovskites and molecular level low dimensional metal halide hybrids, as currently the terminologies of low dimensional perovskites are not appropriately used in many cases. Finally, in this review article, we discuss the synthesis, characterization, application, and computational studies of low dimensional metal halide perovskites and hybrids.

36 MATERIALS SCIENCE↗

Substitutional doping of 2D transition metal dichalcogenides for device applications: Current status, challenges and prospects

Two-dimensional (2D) transition metal dichalcogenides (TMDs) have emerged as a class of materials with exceptional electronic, optical, and mechanical properties, making them highly tunable for diverse applications in nanoelectronics, optoelectronics, and catalysis. Here, this review focuses on substitutional doping of TMDs, a key strategy to tailor their properties and enhance device performance, with a focus on its applications over the past five years (2019–2024). We delve into both theoretical and experimental doping approaches, including established methods like chemical vapor transport (CVT) and chemical vapor deposition (CVD) alongside liquid phase exfoliation (LPE) and post-synthesis treatments. Advanced growth techniques are also explored. Challenges like dopant uniformity, concentration control, and stability are addressed. The influence of various dopants on the electronic band structure, carrier concentration, and defect engineering is analyzed in detail. We further explore recent advancements in utilizing doped TMDs for field-effect transistors (FETs), photodetectors, sensors, photovoltaics, optoelectronic devices, energy storage and conversion, and even quantum computers. By examining both the potential and limitations of substitutional doping, this review aims to propel future research and technological advancements in this exciting field.

36 MATERIALS SCIENCE↗

Engineering shallow and deep level defects in $\kappa$-Ga 2 O 3 thin films: comparing metal-organic vapour phase epitaxy to molecular beam epitaxy and the effect of annealing treatments

Orthorhombic gallium oxide (κ-Ga 2 O 3 ) is an ultra-wide bandgap semiconductor with great potential in new generation electronics. Its application is hindered at present by the limited physical understanding of the relationship between synthesis and functional properties. This work discusses the effects of growth method (metal-organic vapour phase epitaxy and molecular beam epitaxy) as well as annealing treatments in different atmospheres (O 2 , H 2 ) on point defects in κ-Ga 2 O 3 layers epitaxially grown on c-plane sapphire. Comprehensive experimental characterization by X-ray diffraction, photo current-as well as photoluminescence excitation spectroscopy, and X-ray photo electron spectroscopy is combined with first principles calculations of the point defects’ formation and complex-dissociation energies. We demonstrate that for κ-Ga 2 O 3 the concentration of shallow and deep level defects can be sensitively controlled through annealing treatments at temperatures (T = 500 °C) well below the thermal stability threshold of this polymorph. In particular, our results suggest that hydrogen-related defects (e.g., H-interstitials, Ga-vacancies—H complexes) play a key role in this process. While we provide direct exemplary implications of our results for the performances of κ-Ga 2 O 3 based photodetectors, these findings are predicted to impact further application fields of κ-Ga 2 O 3 , such as high electron mobility transistors or memory devices.

36 MATERIALS SCIENCE↗

Realization of BaZrS 3 chalcogenide perovskite thin films for optoelectronics

BaZrS 3 is a prototypical chalcogenide perovskite, an emerging class of unconventional semiconductor. Recent results on powder samples reveal that it is a material with a direct band gap of 1.7–1.8 eV, a very strong light-matter interaction, and a high chemical stability. Due to the lack of quality thin films, however, many fundamental properties of chalcogenide perovskites remain unknown, hindering their applications in optoelectronics. In this work, we report the fabrication of BaZrS 3 thin films, by sulfurization of oxide films deposited by pulsed laser deposition. We show that these films are n-type with carrier densities in the range of 10 19 -10 20 cm -3 . Depending on the processing temperature, the Hall mobility ranges from 2.1 to 13.7 cm 2 /Vs. The absorption coefficient is > 10 5 cm -1 at photon energy >1.97 eV. Temperature dependent conductivity measurements suggest shallow donor levels. By assuring that BaZrS 3 is a promising candidate, these results potentially unleash the family of chalcogenide perovskites for optoelectronics such as photodetectors, photovoltaics, and light emitting diodes.

36 MATERIALS SCIENCE↗

Relative Gain Monitoring of the GlueX Calorimeters

The relative gain of the photodetectors for the GlueX Barrel and Forward calorimeters will be monitored using modular LED driver systems. The BCAL system consists of a global controller that feeds power, bias voltage and trigger signals to 96 local controllers situated at the ends of the 48 BCAL modules, which drive 40 LEDs associated with the 40 light guides at the end of each module. The FCAL system consists also of a global controller, a local controller for each acrylic quadrant covering the face of the FCAL, and ten 4-LED pulser boards per local controller connected in a star configuration along the edges of the acrylic panes. The respective systems are currently being installed on the detectors and their tested performance is presented herein.

43 PARTICLE ACCELERATORS↗

Development of a New Fast Shower Maximum Detector Based on Microchannel Plates Photomultipliers (MCP-PMT) as an Active Element

One possibility to make a fast and radiation resistant shower maximum (SM) detector is to use a secondary emitter as an active element. We present below test beam results, obtained with different types of photodetectors based on microchannel plates (MCPs) as the secondary emitter. We performed the measurements at the Fermilab Test Beam Facility with 120GeV proton beam and 12GeV and 32GeV secondary beams. The goal of the measurement with 120GeV protons was to determine time resolution for minimum ionizing particles (MIPs). The SM time resolution we obtained for this new type of detector is at the level of 20-30ps. We estimate that a significant contribution to the detector response originates from secondary emission of the MCP. This work can be considered as the first step in building a new type of calorimeter based on this principle.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pilot production & commercialization of LAPPD ™

We present a progress update on plans to establish pilot production and commercialization of Large Area (400 cm2) Picosecond Photodetector (LAPPD™). Steps being taken to commercialize this MCP and LAPPD™ technology and begin tile pilot production are presented including (1) the manufacture of 203 mm×203 mm borosilicate glass capillary arrays (GCAs), (2) optimization of MCP performance and creation of an ALD coating facility to manufacture MCPs and (3) design, construction and commissioning of UHV tile integration and sealing facility to produce LAPPDs. Taken together these plans provide a “pathway toward commercialization”.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Picosecond UV single photon detectors with lateral drift field: Concept and technologies

Group III–V semiconductor materials are being considered as a Si replacement for advanced logic devices for quite some time. Advances in III–V processing technologies, such as interface and surface passivation, large area deep submicron lithography with high-aspect ratio etching primarily driven by the metal-oxide-semiconductor field-effect transistor development can also be used for other applications. In this paper we will focus on photodetectors with the drift field parallel to the surface. We compare the proposed concept to the state-of-the-art Si-based technology and discuss requirements which need to be satisfied for such detectors to be used in a single photon counting mode in blue and ultraviolet spectral region with about 10 ps photon timing resolution essential for numerous applications ranging from high-energy physics to medical imaging.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First experimental demonstration of time-resolved X-ray measurements with next-generation fast-timing MCP-PMT

We report the first successful time-resolved X-ray measurements at the APS 10-ID-B beamline by coupling ultrafast scintillators with photodetectors. Multiple scintillator and sensor pairs (LYSO, plastic scintillator, dynode PMTs, MCP-PMT), as well as a standalone detector (diamond), were tested to demonstrate the time-resolved measurements using hard X-rays at energies of 20 keV and above. The experimental results show that a number of choices exist for time-resolved high-energy X-ray beam measurement. Notably, by gating the photocathode, the Argonne fabricated fast-timing microchannel plate photomultiplier and LYSO crystal pair achieved fast signal detection with a rise time of 6 ns and a decay time of 33 ns. Furthermore, these experiments pave the way towards ultrafast imaging technologies using hard X-rays for many applications.

36 MATERIALS SCIENCE↗

Conceptual design and first results for a neutron detector with interaction localization capabilities

In this study, a new high-precision detector for studying neutrons from beta-delayed neutron emission and direct reaction studies is proposed. The Neutron dEtector with multi-neutron (denoted Xn) Tracking (NEXT) array is designed to maintain high intrinsic neutron detection efficiency while reducing uncertainties in neutron energy measurements. A single NEXT module is composed of thin segments of plastic scintillator, each optically separated, capable of neutron-gamma discrimination. Each segmented module is coupled to position sensitive photodetectors enabling the high-precision determination of neutron time of arrival and interaction position within the active volume. A design study has been conducted based on simulations and experimental tests leading to the construction of prototype units. First results from measurements using a 252 Cf neutron source and accelerator-produced monoenergetic neutrons are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of Large Area Picosecond Photo-Detectors (LAPPD TM )

In this study, we report on performance results achieved for recently produced LAPPDs - largest commercially available planar geometry photodetectors based on microchannel plates. These results include electron gains of up to 1 0 7 , low dark noise rates (~100 Hz/cm 2 at a gain of 6 ∙ 1 0 6 ), single photoelectron (PE) timing resolution of ~50 picoseconds RMS (electronics limited), and single photoelectron spatial resolution along and across strips of 3.2mm (electronics limited) and 0.8 mm RMS respectively and high (about 25% or higher in some units) QE uniform bi-alkali photocathodes. LAPPDs is a good candidate to be employed in neutrino experiments (e.g. ANNIE (Back et al., 2017), WATCHMAN (Askins et al., 2015), DUNE (Capozzi et al., 2018), particle collider experiments (e.g. EIC (Accardi et al., 2016), neutrinoless double-beta decay experiments (e.g. THEIA (Fischer et al., 2018)), medical and nuclear non-proliferation applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Low-dose high-resolution $\mathrm{TOF}$-$\mathrm{PET}$ using ionization-activated multi-state low-$\mathrm{Z}$ detector media

We propose PET scanners using low atomic number media that undergo a persistent local change of state along the paths of the Compton recoil electrons. Measurement of the individual scattering locations and angles, deposited energies, and recoil electron directions allows using the kinematical constraints of the 2-body Compton scattering process to perform a statistical time-ordering of the scatterings, with a high probability of precisely identifying where the gamma first interacted in the detector. In these cases the Line-of-Response is measured with high resolution, determined by the underlying physics processes and not the detector segmentation. There are multiple such media that act through different mechanisms. As an example in which the change of state is quantum-mechanical through a change in molecular configuration, rather than thermodynamic, as in a bubble chamber, we present simulations of a two-state photoswitchable organic dye, a ‘Switchillator’, that is activated to a fluorescent-capable state by the ionization of the recoil electrons. The activated state is persistent, and can be optically excited multiple times to image individual activated molecules. Energy resolution is provided by counting the activated molecules. Location along the LOR is implemented by large-area time-of-flight MCP-PMT photodetectors with single photon time resolution in the tens of ps and sub-mm spatial resolution. Simulations indicate a large reduction of dose.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A SiPM-based optical readout system for the EIC dual-radiator RICH

Silicon photomultipliers (SiPM) are candidates selected as the potential photodetector technology for the dual-radiator Ring-Imaging Cherenkov (dRICH) detector at the future Electron-Ion Collider (EIC). SiPM are cheap devices, highly efficient and insensitive to the high magnetic field at the expected location of the sensors in the experiment. Here, on the other hand, SiPM are not radiation tolerant. Despite the integrated radiation level is expected to be moderate it should be tested whether single photon-counting capabilities and the increase in dark count rate can be kept under control to maintain the optimal dRICH detector performance across the years. The current status of the research for the EIC dRICH application and the first results on studies performed on a sample of commercial and prototype SiPM sensors are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Absolute light yield of the EJ-204 plastic scintillator

The absolute light yield of a scintillator, defined as the number of scintillation photons produced per unit energy deposited, is a useful quantity for scintillator development, research, and applications. Yet, literature data on the absolute light yield of organic scintillators are limited. The goal of this work is to assess the suitability of the EJ-204 plastic scintillator from Eljen Technology to serve as a reference standard for measurements of the absolute light yield of organic scintillators. Four EJ-204 samples were examined: two manufactured approximately four months prior and stored in high-purity nitrogen, and two aged approximately eleven years and stored in ambient air. The scintillator response was measured using a large-area avalanche photodiode calibrated using low energy $γ$-ray and X-ray sources. The product of the quantum efficiency of the photodetector and light collection efficiency of the housing was characterized using an experimentally-benchmarked optical photon simulation. The average absolute light yield of the fresh samples, 9100 ± 400 photons per MeV, is lower than the manufacturer-reported value of 10400 photons per MeV. Moreover, the aged samples demonstrated significantly lower light yields, deviating from the manufacturer specification by as much as 26%. These results are consistent with recent work showcasing environmental aging in plastic scintillators and suggest that experimenters should use caution when deploying plastic scintillators in photon counting applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sub-millimeter resolution SiPM-based neutron anger camera

Thermal and cold neutron beamlines require detector systems that have a high neutron efficiency, large active area, and good spatial resolution. One type of detector that has been implemented at beamlines at the Spallation Neutron Source (SNS) is a scintillator-based Anger camera that utilizes photomultiplier tubes (PMTs) as photodetectors. In this work, we present a new Anger camera design that replaces PMTs with silicon photomultipliers (SiPMs). This new design offers better resolution, less distortion, and more compactness than the previous cameras. A camera with active area of ~100 cm 2 was shown to have a spatial resolution better than 0.5 mm. Additionally, the use of SiPMs allows for use in strong magnetic fields, opening the possibility of additional experimental capabilities. In conclusion, prototype has been built that demonstrates vacuum-compatibility, as required for a proposed beamline for the Second Target Station at SNS.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

PICOSEC-Micromegas Detector, an innovative solution for Lepton Time Tagging

The PICOSEC-Micromegas (PICOSEC-MM) detector is a novel gaseous detector designed for precise timing resolution in experimental measurements. It eliminates time jitter from charged particles in ionization gaps by using extreme UV Cherenkov light emitted in a crystal, detected by a Micromegas photodetector with an appropriate photocathode. The first single-channel prototype tested in 150 GeV/c muon beams achieved a timing resolution below 25 ps, a significant improvement compared to standard Micropattern Gaseous Detectors (MPGDs). This work explores the specifications for applying these detectors in monitored neutrino beams for the ENUBET Project. Key aspects include exploring resistive technologies, resilient photocathodes, and scalable electronics. New 7-pad resistive detectors are designed to handle the particle flux. In this paper, two potential scenarios are briefly considered: tagging electromagnetic showers with a timing resolution below 30ps in an electromagnetic calorimeter as well as individual particles (mainly muons) with about 20ps respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

HRPPD photosensors for RICH detectors with a high resolution timing capability

Recently, a new version of DC-coupled High Rate Picosecond Photodetectors (DC-HRPPDs) substantially re-designed for use at the Electron-Ion Collider (EIC) has been developed. A first batch of seven “EIC HRPPDs” was manufactured in early 2024. These HRPPDs are DC-coupled photosensors based on Micro-Channel Plates (MCPs) that have an active area of 104 mm by 104 mm, 32 × 32 direct readout pixel array at a pitch of 3.25 mm, peak quantum efficiency in excess of 30%, exceptionally low dark count rates and timing resolution of 15–20 ps for a single photon detection. As such, these photosensors are very well suited for Ring Imaging CHerenkov (RICH) detectors that can additionally provide high resolution timing capability, especially in a configuration where a detected charged particle passes through the sensor window, which produces a localized flash containing a few dozens of Cherenkov photons in it.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Multiplexable intrinsic Fabry-Pérot interferometers inscribed by femtosecond laser for vibration measurement in high temperature environments

This article reports fabrication technique and demodulation algorithm developments to use multiplexable intrinsic Fabry-Pérot interferometer (IFPI) fiber sensor array for distributed vibration measurements at high temperatures. Using femtosecond laser direct writing scheme, IFPI array were fabricated through laser-induced Type II scattering points in single mode fiber cores. Reflection spectra of IFPI array were demodulated in real-time using modified Bunemen frequency analysis. The demodulation algorithm, which was implemented using a photodetector-array spectrometer, achieves 64-nε dynamic strain resolution at 1-kHz spectral acquisition rate and 2-kHz maximum vibration bandwidth. Performance and stabilities of IFPI sensor array were characterized from room temperatures to 800 °C. The static strain resolution was 0.6 με and the minimum detectable dynamic strain amplitude was 23 nε/√Hz at 800 °C. The multiplex performance was also tested by measuring dynamic strain in time domain through six IFPI sensor array fabricated in one fiber. This paper presents an integrated and low-cost sensing solution to perform distributed vibration measurements in harsh environments.