Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Optical Imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

Use of the Airborne Visible/Infrared Imaging Spectrometer to Calibrate the Optical Sensor on Board the Japanese Earth Resources Satellite-1

In this paper, we describe an experiment to calibrate the Optical Sensor on board the Japanese Earth Resources Satellite-1 with data acquired by the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS). This experiment establishes the suitability of AVIRIS for the calibration of spaceborne sensors in the 400 to 2500 nm spectral region.

spaceborne↗

SpaceNet 9—Cross-Sensor Alignment of Optical and SAR Imagery

Precise registration of high-resolution synthetic aperture radar (SAR) and optical imagery is necessary for realizing the full potential and benefits of multimodal image analysis. However, two significant challenges presently exist. First, there is a lack of annotated datasets and benchmarks available for high-resolution SAR–optical image registration. Second, an assessment of efficient and reliable image registration methods that can precisely align these modalities is lacking. Here, we present a holistic description of the SpaceNet 9 Challenge and its results. We present a description of the dataset and baseline algorithm along with the results of the challenge, including a description of the winning algorithms. We release the SpaceNet 9 dataset along with open-sourcing the winning algorithms and baseline. The objective of SpaceNet 9 was to compute a dense displacement map that indicates the shift needed to align pixels in an optical image to the pixels in a SAR image. The challenge launched in April 2025 and was active for approximately two months. The top five solutions reduced image alignment error from approximately 34 m to under 13 m for public and private test data, with the best results obtaining a registration error of only 8.5 and 6.7 m on the public testing and private testing dataset, respectively. Usage of pretrained image matching models, robust outlier rejection with RANSAC, and estimating local displacement were common among the top solutions. The results of this challenge provide insight into high-resolution SAR–optical image registration and offer opportunities for future benchmarking in this domain. The baseline algorithm, winning solutions, and datasets are available at https://spacenet.ai/sn9-challenge/.

benchmark datasets↗

Precision alignment of an infrared imaging system

The optical hardware design and methods of alignment for the GOES (Geostationary Operational Environmental Satellite) imaging instrument are discussed. The instrument is a multi-channel space-borne meteorological system. Included will be the results of a tolerance and sensitivity analysis for the optics and their adjustment mechanisms. A brief summary of the sequence of system alignment steps taken to achieve the final configuration of the instrument will conclude the discussion.

Kohrman, Richard J.↗

Use of the Airborne Visible/Infrared Imaging Spectrometer to calibrate the optical sensor on board the Japanese Earth Resources Satellite-1

We describe an experiment to calibrate the optical sensor (OPS) on board the Japanese Earth Resources Satellite-1 with data acquired by the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS). On 27 Aug. 1992 both the OPS and AVIRIS acquired data concurrently over a calibration target on the surface of Rogers Dry Lake, California. The high spectral resolution measurements of AVIRIS have been convolved to the spectral response curves of the OPS. These data in conjunction with the corresponding OPS digitized numbers have been used to generate the radiometric calibration coefficients for the eight OPS bands. This experiment establishes the suitability of AVIRIS for the calibration of spaceborne sensors in the 400 to 2500 nm spectral region.

Green, Robert O.↗

Steps Toward a Large Space-Based UV/Optical Fizeau Interferometer: The GSFC Fizeau Interferometer Testbed (FIT)

Goddard Space Flight Center is pursuing the development of space-based, long-baseline (0.5km) UV-optical Fizeau imaging interferometers to enable the next major stride toward very high angular resolution astronomical observations. This effort includes the development and operation of the Fizeau Interferometry Testbed (FIT), in collaboration with the Naval Research Lab/NPOI, Univ. of MD, and Sigma Space Corporation. The FIT will be used to explore the principles of and requirements for the Stellar Imager (SI) mission concept (http://hires.gsfc.nasa.gov/~si) and other such Fizeau Interferometers/Sparse Aperture Telescope missions, leading in the end to the Planet Imager (PI), which is the ultimate goal of the current Origins Program. The primary goal of the FIT program is to demonstrate closed-loop control of mirrors (tip, tilt, piston, translation of array elements) and the overall system to keep the optical beams in phase and enable high quality imaging by a many-element (7-30) Fizeau Interferometric System. The FIT will also be used to assess various wave-front reconstruction and sensing and image reconstruction algorithms for utility and accuracy by application to real data generated by the Testbed. In this paper, we describe the design and goals of the system, provide a status report on its construction, and note our future plans.

Carpenter, K. G.↗

Optical alignment of a pupil imaging spectrometer

The GOES Sounder is a 19-channel discrete filter spectrometer with an additional channel for star sensing. This paper presents the GOES Sounder's instrument optics and compensations, alignment rationale, and alignment mechanism and sensitivities. The results of a line of sight tolerance analysis of the instrument are described, and the prealignment and instrument coregistration are addressed.

Horchem, Stephen D.↗

Enhanced imaging of electronic hot spots using quantum squeezed light

Detecting electronic hot spots is important for understanding the heat dissipation and thermal management of electronic and semiconductor devices. Optical thermoreflective imaging is being used to perform precise temporal and spatial imaging of heat on wires and semiconductor materials. We apply quantum squeezed light to perform thermoreflective imaging on micro-wires, surpassing the shot-noise limit of classical approaches. We obtain a far-field temperature sensing accuracy of 42 mK after 50 ms of averaging and show that a 256×256 pixel image can be constructed with such sensitivity in 10 min. We can further obtain single-shot temperature sensing of 1.6 K after only 10 μs of averaging, enabling a dynamical study of heat dissipation. Not only do the quantum images provide accurate spatiotemporal information about heat distribution but also the measure of quantum correlation provides additional information, inaccessible by classical techniques, which can lead to a better understanding of the dynamics. We apply the technique to both aluminum and niobium microwires and discuss the applications of the technique in studying electron dynamics at low temperatures.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Survey Plan For Characterization of the Subsurface Underlying the National Aeronautics and Space Administration's Marshall Space Flight Center in Huntsville, Alabama

Topic considered include: survey objectives; technologies for non-Invasive imaging of subsurface; cost; data requirements and sources; climatic condition; hydrology and geology; chemicals; magnetometry; electrical(resistivity, potential); optical-style imaging; reflection/refraction seismics; gravitometry; photo-acoustic activation;well drilling and borehole analysis; comparative assessment matrix; ground sensors; choice of the neutron sources; logistic of operations; system requirements; health and safety plans.

Source record↗

Nondestructive Evaluation of Thermal Barrier Coatings by Mid-infrared Reflectance

The application of mid-infrared reflectance (MIR) imaging to monitor damage in thermal barrier coatings (TBCs) has been extended from a previously demonstrated area-averaged spectroscopic analysis tool to become a practical imaging tool that provides the spatial resolution needed to quickly identify localized regions of TBC damage by visual inspection, Illumination optics and image collection procedures were developed to produce illumination-normalized flatfield reflectance images after subtraction of the background thermal emission. MIR reflectance images were collected with a bandpass filter centered at a wavelength of 4 microns, which provided the optimum balance between good sensitivity to buried cracks and coating erosion, but with a desirable sensitivity to TBC sintering and absorption from ambient gases. Examples are presented of the application of MIR reflectance imaging to monitor damage progression in plasma-sprayed 8wt% yttria-stabilized zirconia (8YSZ) TBCs subjected to either furnace cycling or alumina particle jet erosion. These results show that MIR reflectance imaging can reliably track the progression of buried delamination cracks produced by thermal cycling and can also be used to determine when any local section of the TBC has eroded beyond an acceptable limit. Modeling of the effects of buried cracks and erosion on reflectance will be presented to show the dependence of damage sensitivity to TBC thickness.

Eldridge, Jeffrey I↗

Spatially Resolved Mapping of Three-Dimensional Molecular Orientations with ~2 nm Spatial Resolution through Tip-Enhanced Raman Scattering

We record local optical field images of silver nanocubes (75 nm) using tip-enhanced Raman (TER) spectral imaging. The images that we observe are consistent with several recent reports from our group, but here, we demonstrate sub-2 nm spatial resolution in local optical field nanoimaging under ambient laboratory conditions. This is achieved by scanning the substrate (nanocube on Si) relative to a 4-thiobenzonitrile (TBN)-functionalized Ag-coated TER probe. The spatial resolution that we obtain necessitates that only a few molecules govern the recorded optical response; molecular orientation becomes an important consideration in such measurements. We model the orientation through geometry optimization of a TBN molecule chemisorbed onto an Ag79 cluster (sphere with a ~1 nm diameter). Using the computed orientation of the cluster-bound molecule, we then model the optical response using formalism that accounts for the orientation of the molecule relative to vector components of the local optical fields. We find optimal agreement between experiment and theory. In effect, this work reveals the parallels between single-molecule Raman scattering and high-spatial-resolution TER spectroscopy, even when the images themselves cannot be used to visualize a single molecule in real space.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Further Support of the Development of Advanced Multilayer Optics Coatings for X-Ray Imaging

The Smithsonian Astrophysical Observatory (SAO) is working with Lawrence Livermore National Laboratory (LLNL) to develop Wolter-I optics for x-ray imaging applications at energies of 15-50 keV and above for National Nuclear Security Administration (NNSA) facilities. SAO work includes R&D on advanced multilayer coatings as well as fabrication and testing of Wolter multilayer coated optics. It also includes delivery of custom 3.05-meter focal length Wolter optics with response at energies of interest to Sandia National Laboratories and LLNL. The optics are fabricated using an electroform nickel replication technique which has been used to fabricate optics for X-ray astronomy satellites over the past two decades. This technique starts with a figured, polished mandrel from which the optics are replicated. To carry this technique over to fabricate optics for NNSA facilities, several additional barriers had to be overcome to deposit multilayer coatings on integral optics with radii as small as 25 mm. These breakthroughs allow fabrication of optics which meet the spatial and spectral specifications required by NNSA facilities. During this present contract period SAO delivered four custom optics to LLNL with spectral response at or near the Kα line of silver, 22.16 keV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Structural and optical properties of nanoparticles formed by laser ablation of porous silicon in liquids: Perspectives in biophotonics

The paper discusses the possibility of manufacturing silicon nanoparticles, which are suitable for contrasting biological tissues imaged by optical coherence tomography, by femtosecond laser ablation of porous silicon in various liquids. The manufactured nanoparticles are characterised by average sizes of 87, 112, and 102 nm for cases of ablation in water, ethanol, and liquid nitrogen, respectively, as well as a relatively narrow size distribution, which provides additional advantages for subsequent delivery into biological tissues. Electrochemical etching, which results in the formation of layers of porous silicon, allows the yield of ablation products to be increased several-fold by lowering the ablation threshold, thereby increasing the light scattering efficiency of the prepared suspensions compared with the case of using crystalline silicon as targets. The possibility of obtaining high-contrast images of a biotissue phantom based on an agar gel with embedded nanoparticles is shown. The magnitude of the contrast depends on the liquid used for ablation and correlates with the values of the reduced scattering coefficient of the studied suspensions. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Stochastic frequency fluctuation super-resolution imaging

The inherent non-linearity of intensity correlation functions can be used to spatially distinguish identical emitters beyond the diffraction limit, as achieved, for example, in super-resolution optical fluctuation imaging (SOFI). Here, we propose a complementary concept based on spectral correlation functions, termed spectral fluctuation super-resolution (SFSR) imaging. Through theoretical and computational analysis, we show that spatially resolving time-frequency correlation functions in the image plane can improve the imaging resolution by a factor of $\sqrt2$ in most cases and up to twofold for strictly two emitters. This improvement is achieved by quantifying the degree of correlation in spectral fluctuations across the spatial domain. Experimentally, SFSR can be implemented using a combination of interferometry and photon-correlation measurements. The method works for non-blinking emitters and stochastic spectral fluctuations with arbitrary temporal statistics. This suggests its utility in super-resolution microscopy of quantum emitters at low temperatures, where spectral diffusion is often more pronounced than emitter blinking.

47 OTHER INSTRUMENTATION↗

Osiris-Rex Post-Tag Observation Trajectory Design and Navigation Performance

NASA’s OSIRIS-REx spacecraft successfully collected a sample of asteroid regolith from the surface of near-Earth asteroid Bennu in October of 2020. Subsequent imaging of the sampler head showed material leaking from the collection mechanism, thus stowage of the sample precluded execution of any planned maneuvers in the following days. Optical navigation imaging also ceased in the days following sample collection. The desire to image the sample site to investigate the results of the spacecraft-to-surface interaction led to the Navigation team designing a trajectory to return to Bennu after several months in order to image the surface one final time. After several iterations a trajectory design was created that satisfied the numerous constraints that were levied in order to place utmost importance on the safety of the spacecraft and stowed sample, while also closely emulating previously obtained imaging conditions to provide a close comparison of site pre- and post-contact. Significant analysis was necessary in order to reliably reacquire the asteroid after several months without optical navigation imagery. The final design required five maneuvers to return the spacecraft to Bennu and perform a final flyby of the asteroid at a distance of 3.8 kilometers. Successful execution of the phase provided key insights regarding the performance of the sample collection activities and the subsurface composition of the asteroid.

Daniel R Wibben↗

An instrument for in situ characterization of powder spreading dynamics in powder-bed-based additive manufacturing processes

In powder-bed-based metal additive manufacturing (AM), the visualization and analysis of the powder spreading process are critical for understanding the powder spreading dynamics and mechanisms. Unfortunately, the high spreading speeds, the small size of the powder, and the opacity of the materials present a great challenge for directly observing the powder spreading behavior. In this study, we report a compact and flexible powder spreading system for in situ characterization of the dynamics of the powders during the spreading process by high-speed x-ray imaging. The system enables the tracing of individual powder movement within the narrow gap between the recoater and the substrate at variable spreading speeds from 17 to 322 mm/s. The instrument and method reported here provide a powerful tool for studying powder spreading physics in AM processes and for investigating the physics of granular material flow behavior in a confined environment.

47 OTHER INSTRUMENTATION↗

The Optical Counterpart of M101 ULX-1

We have identified the optical counterpart of the Ultra-Luminous X-ray source Ml0l ULX-1 (CX- OKM101 J140332.74+542102), by comparing HST ACS images with Chandra ACIS-S images. The optical counterpart has V= 23.75 and colours consistent with those for a mid-B supergiant. Archival WFPC2 observations show that the source brightness is constant to within approximately 0.1 mag. The physical association of this source with the ULX is confirmed by Gemini GMOS spectroscopic observations which show spatially unresolved He II lambda4686 and He I lambda5876 emission. These results suggest that M10l ULX-1 is a HMXB but deep spectroscopic monitoring observations are needed to determine the detailed properties of this system.

Kuntz, K. D.↗

Development of Two Color Fluorescent Imager and Integrated Fluidic System for Nanosatellite Biology Applications

Nanosatellites offer frequent, low-cost space access as secondary payloads on launches of larger conventional satellites. We summarize the payload science and technology of the Microsatellite in-situ Space Technologies (MisST) nanosatellite for conducting automated biological experiments. The payload (two fused 10-cm cubes) includes 1) an integrated fluidics system that maintains organism viability and supports growth and 2) a fixed-focus imager with fluorescence and scattered-light imaging capabilities. The payload monitors temperature, pressure and relative humidity, and actively controls temperature. C. elegans (nematode, 50 m diameter x 1 mm long) was selected as a model organism due to previous space science experience, its completely sequenced genome, size, hardiness, and the variety of strains available. Three strains were chosen: two green GFP-tagged strains and one red tdTomato-tagged strain that label intestinal, nerve, and pharyngeal cells, respectively. The integrated fluidics system includes bioanalytical and reservoir modules. The former consists of four 150 L culture wells and a 4x5 mm imaging zone the latter includes two 8 mL fluid reservoirs for reagent and waste storage. The fluidic system is fabricated using multilayer polymer rapid prototyping: laser cutting, precision machining, die cutting, and pressure-sensitive adhesives it also includes eight solenoid-operated valves and one mini peristaltic pump. Young larval-state (L2) nematodes are loaded in C. elegans Maintenance Media (CeMM) in the bioanalytical module during pre-launch assembly. By the time orbit is established, the worms have grown to sufficient density to be imaged and are fed fresh CeMM. The strains are pumped sequentially into the imaging area, imaged, then pumped into waste. Reagent storage utilizes polymer bags under slight pressure to prevent bubble formation in wells or channels. The optical system images green and red fluorescence bands by excitation with blue (473 nm peak) and amber (587 nm peak) LEDs it achieves 8 m lateral resolution using a CMOS imaging chip (as configured for serial data speeds) or 4 m resolution using USB imaging chips. The imager consists of a modified commercial off-the-shelf CMOS chip camera, amber, blue and white LEDs, as well as a relay lens and dual-band filters to obviate moving parts while supporting both fluorescence wavelengths.

Wu, Diana Terri↗