Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “NEUTRON SCIENCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63

Non-invasive Field Measurements of Soil Water Content Using a Pulsed 14 MeV Neutron Generator

Current techniques of soil water content measurement are invasive and labor-intensive. Here, we demonstrate that an in situ soil carbon (C) analyzer with a multi-elemental analysis capability, developed for studies of terrestrial C sequestration, can be used concurrently to non-invasively measure the water content of large-volume ({approx}0.3 m{sup 3}) soil samples. Our objectives were to investigate the correlations of the hydrogen (H) and oxygen (O) signals with water to the changes in the soil water content in laboratory experiments, and in an agricultural field. Implementing prompt gamma neutron activation analyses we showed that in the field, the signal from the H nucleus better indicates the soil water content than does that from the O nucleus. Using a field calibration, we were able to use the H signal to estimate a minimum detectable change of {approx}2% volumetric water in a 0-30 cm depth of soil.

08 HYDROGEN↗

Influence of molecular clustering on the interpretation of diffractograms of hydrocarbon films from tokamak T-10

The influence of molecular clustering on the formerly suggested interpretation of diffraction patterns of hydrocarbon films formed in the vacuum vessel of the tokamak T-10 is analyzed numerically. The simulation of clustering of simple hydrocarbon molecules C(D, H){sub 4}, C{sub 2}(D, H){sub 4}, and C{sub 6}(D, H){sub 6} and molecules composed of curved graphene (fullerenes and toroidal nanotubes) is carried out with the rigid body molecular dynamics method. It is shown that formerly neglected atomic correlations C–C and C–D(H) in the amorphous hydrocarbon component decrease the calculated values of the scattered intensity in the range of scattering vector modulus 5 < q < 20 nm{sup –1} because of homogenization of scatters on the spatial scale of ∼1 nm. The allowance for these correlations does not change the diffraction patterns in the range q > 20 nm{sup –1}. The results suggest the necessity to introduce to the procedure of determining the structural content of the films, similar to those from the tokamak T-10, the clusters formed by the van der Waals adhesion of hydrocarbon molecules to “graphene” nanoparticles. This simplifies the mathematical optimization to the former level of complexity—but for an extended ensemble of objects—and makes it possible to calculate the diffraction patterns of these objects using the distributed computing resources. A modified algorithm of structural content identification on the basis of joint X-ray and neutron diffractometry is suggested.

36 MATERIALS SCIENCE↗

Freezing of Dynamics of a Methyl Group in a Protein Hydrophobic Core at Cryogenic Temperatures by Deuteron NMR Spectroscopy

Proteins undergo a number of changes when their temperature is dropped from the physiological range to much lower values. One of the most well-known dynamical changes undergone by proteins in a solid state is a so-called protein glass-transition, which is a dynamic transition occurring at about 200-230K leading to a loss of biological activity.1,2 X-ray diffraction, neutron scattering studies, and dielectric spectroscopy, as well as evidence from NMR relaxation measurements, indicate freezing of slow collective modes of motion below the glass transition temperature.3-8 Various arguments have been presented that connect the transition to solvent participation.1,4,8-10 In addition to the solvent-related modes that are frozen below the glass-transition temperature, there are anharmonic motions at temperatures below 200K which are likely to be dominated by methyl group dynamics down to about 100K.2,5,7 Recent neutron-scattering and NMR studies emphasize the role of these modes in low temperature dynamics. 2,5,7,11,12 One of the latest works on the subject by Bajaj et al.11 has reported a structural transition associated with dynamic processes in a solvent-free polypeptide. Thus, protein dynamics at low temperatures are complex and more studies are required to discern their pattern.

36 MATERIALS SCIENCE↗

Magnetic structure of triangular lattice compound Tb2Ni0.90Si2.94

AlB 2 -type ternary intermetallic compound Tb 2 Ni 0.90 Si 2.94 (space group P 6=mmm, hP 3, No. 191) was reported to exhibit spin freezing behaviour of the ferromagnetic clusters present in the system below T f = 9:9 K, along with the presence of spatially limited antiferromagnetic phase. In this work, on the basis of variable temperature zero-field neutron diffraction measurements, we have shown that the antiferromagnetic phase transition occurs for the compound below T N ~13 K. Neutron diffraction study indicates ab-plane non-collinear sine-modulated antiferromagnetic ordering of the system with wave vectors of k 1 = [±1/6, ±1/6, 0] and k 2 = [±1/3, ±1/3, 0] down to 1.7 K. The weak and diffuse nature of the magnetic Bragg peaks along with limited coherence length further confirm the short-range nature of the antiferromagnetic phase in this compound.

36 MATERIALS SCIENCE↗

Aerial Neutron Detection: Neutron Signatures for Nonproliferation and Emergency Response Applications

From 2007 to the present, the Remote Sensing Laboratory has been conducting a series of studies designed to expand our fundamental understanding of aerial neutron detection with the goal of designing an enhanced sensitivity detection system for long range neutron detection. Over 35 hours of aerial measurements in a helicopter were conducted for a variety of neutron emitters such as neutron point sources, a commercial nuclear power reactor, nuclear reactor spent fuel in dry cask storage, depleted uranium hexafluoride and depleted uranium metal. The goals of the project were to increase the detection sensitivity of our instruments such that a 5.4 × 104 neutron/second source could be detected at 100 feet above ground level at a speed of 70 knots and to enhance the long-range detection sensitivity for larger neutron sources, i.e., detection ranges above 1000 feet. In order to increase the sensitivity of aerial neutron detection instruments, it is important to understand the dynamics of the neutron background as a function of altitude. For aerial neutron detection, studies have shown that the neutron background primarily originates from above the aircraft, being produced in the upper atmosphere by galactic cosmic-ray interactions with air molecules. These interactions produce energetic neutrons and charged particles that cascade to the earth’s surface, producing additional neutrons in secondary collisions. Hence, the neutron background increases as a function of altitude which is an impediment to long-range neutron detection. In order to increase the sensitivity for long range detection, it is necessary to maintain a low neutron background as a function of altitude. Initial investigations show the variation in the neutron background can be decreased with the application of a cosmic-ray shield. The results of the studies along with a representative data set are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Exploiting fission chain reaction dynamics to image fissile materials

Radiation imaging is one potential method to verify nuclear weapons dismantlement. In this work, we present a method to discriminate between non-multiplying and multiplying neutron sources using a neutron coded aperture imaging system. This method applies time-correlated pulse-height (TCPH) analysis to identify neutrons in fission chain reactions and recreate images using only these events. This analysis was applied to measurements of weapons-grade plutonium (WGPu) metal and 252 Cf performed at the Nevada National Security Site (NNSS) Device Assembly Facility in July 2015. The results demonstrate it is possible to eliminate the non-fissile 252 Cf source from the image while preserving the fissile WGPu source. TCPH analysis was also applied to additional scenes in which the WGPu and 252 Cf sources were measured individually. The results of these separate measurements further demonstrate the ability to remove the non-fissile 252 Cf source and retain the fissile WGPu source. Simulations performed using MCNPX-PoliMi indicate that in a one hour measurement, hollow WGPu spheres are retained at a 1σ level for neutron multiplications M ≃ 2:7 and above. This work has potential application to dismantlement verification where it may be valuable to verify that all neutron sources in an image are multiplying.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimization of a Fast Neutron Scintillator for Real-Time Pulse Shape Discrimination in the Transient Reactor Test Facility (TREAT) Hodoscope

We present a multi-channel, fast neutron/gamma ray detector array system that utilizes ZnS(Ag) scintillator detectors. The system employs field programmable gate arrays (FPGAs) to do real-time all digital neutron/gamma ray discrimination with pulse height and time histograms to allow count rates in excess of 1,000,000 pulses per second per channel. The system detector number is scalable in blocks of 16 channels.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of a Fast Neutron Detection System With Large Angular Coverage and Granularity for Physics Studies and Applications

This work presents a review of fast neutron detection, with an emphasis on the use of plastic scintillating materials. We developed neutron detectors both at the Instituto de Fisica, UNAM and at the Tandem Accelerator Laboratory, ININ. We will describe in detail our detectors and their characteristics. We will present some results on the development of a large position-sensitive neutron detector in two dimensions. In particular, we present a phenomenological formula that describes the complex dependence of the amount of light reaching a detector as a function of the position of the light source within the scintillating material. First measurements with a very small number of detectors are presented and show encouraging results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electric current-induced precipitation hardening in advanced high-strength steel

Effect of electric current on precipitation hardening for advanced high-strength steel is investigated based on mechanical testing and microscopic observation. Complex-phase steel containing nano-sized Nb-bearing carbides was used. By comparing the flow stress between uniaxial tension with applied electric current (pulsed tension) and without electric current (nonpulsed tension) at various elevated temperatures, the influence of electric current on precipitation hardening was confirmed. A higher values of Vickers hardness and full-width-at-half-maximum were obtained in the pulsed tensile specimen compared to the identically heat treated specimen after the same deformation. Small angle neutron scattering analysis showed that the volume fraction and mean diameter of newly formed precipitates in the pulsed tensile specimen were higher and larger than those in the induction heat treated specimen, respectively. In conclusion, it clearly shows that additional precipitation hardening could be induced by the athermal effect of electric current, which is distinct from the thermal effect of Joule heating.

36 MATERIALS SCIENCE↗

Parametric Evaluation of Active Neutron Interrogation for the Detection of Shielded Highly-Enriched Uranium in the Field

Parametric studies using numerical simulations are being performed to assess the performance capabilities and limits of active neutron interrogation for detecting shielded highly enriched uranium (HEU). Varying the shield material, HEU mass, HEU depth inside the shield, and interrogating neutron source energy, the simulations account for both neutron and photon emission signatures from the HEU with resolution in both energy and time. The results are processed to represent different irradiation timing schemes and several different classes of radiation detectors, and evaluated using a statistical approach considering signal intensity over background. This paper describes the details of the modeling campaign and some preliminary results, weighing the strengths of alternative measurement approaches for the different irradiation scenarios.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improved neutron-gamma discrimination for a {sup 6}Li-glass neutron detector using digital signal analysis methods

A {sup 6}Li-glass scintillator (GS20) based neutron Anger camera was developed for time-of-flight single-crystal diffraction instruments at Spallation Neutron Source. Traditional Pulse-Height Analysis (PHA) for Neutron-Gamma Discrimination (NGD) resulted in the neutron-gamma efficiency ratio (defined as NGD ratio) on the order of 10{sup 4}. The NGD ratios of Anger cameras need to be improved for broader applications including neutron reflectometers. For this purpose, six digital signal analysis methods of individual waveforms acquired from photomultiplier tubes were proposed using (i) charge integration, (ii) pulse-amplitude histograms, (iii) power spectrum analysis combined with the maximum pulse-amplitude, (iv) two event parameters (a{sub 1}, b{sub 0}) obtained from a Wiener filter, (v) an effective amplitude (m) obtained from an adaptive least-mean-square filter, and (vi) a cross-correlation coefficient between individual and reference waveforms. The NGD ratios are about 70 times those from the traditional PHA method. Our results indicate the NGD capabilities of neutron Anger cameras based on GS20 scintillators can be significantly improved with digital signal analysis methods.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultrasonic Transducer Irradiation Test Results

Ultrasonic technologies offer the potential for high-accuracy and -resolution in-pile measurement of a range of parameters, including geometry changes, temperature, crack initiation and growth, gas pressure and composition, and microstructural changes. Many Department of Energy-Office of Nuclear Energy (DOE-NE) programs are exploring the use of ultrasonic technologies to provide enhanced sensors for in-pile instrumentation during irradiation testing. For example, the ability of small diameter ultrasonic thermometers (UTs) to provide a temperature profile in candidate metallic and oxide fuel would provide much needed data for validating new fuel performance models. Other ongoing efforts include an ultrasonic technique to detect morphology changes (such as crack initiation and growth) and acoustic techniques to evaluate fission gas composition and pressure. These efforts are limited by the lack of identified ultrasonic transducer materials capable of long term performance under irradiation test conditions. For this reason, the Pennsylvania State University (PSU) was awarded an ATR NSUF project to evaluate the performance of promising magnetostrictive and piezoelectric transducers in the Massachusetts Institute of Technology Research Reactor (MITR) up to a fast fluence of at least 10 21 n/cm 2 . The goal of this research is to characterize and demonstrate magnetostrictive and piezoelectric transducer operation during irradiation, enabling the development of novel radiation-tolerant ultrasonic sensors for use in Material Testing Reactors (MTRs). As such, this test is an instrumented lead test and real-time transducer performance data is collected along with temperature and neutron and gamma flux data. The current work bridges the gap between proven out-of-pile ultrasonic techniques and in-pile deployment of ultrasonic sensors by acquiring the data necessary to demonstrate the performance of ultrasonic transducers. To date, one piezoelectric transducer and two magnetostrictive transducers have demonstrated reliable operation under irradiation. The irradiation is ongoing.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Source detection at 100 meter standoff with a time-encoded imaging system

Here, we present the design, characterization, and testing of a laboratory prototype radiological search and localization system. The system, based on time-encoded imaging, uses the attenuation signature of neutrons in time, induced by the geometrical layout and motion of the system. We have demonstrated the ability to detect a ~1 mCi 252 Cf radiological source at 100 m standoff with 90% detection efficiency and 10% false positives against background in 12 min. As a result, this same detection efficiency is met at 15 s for a 40 m standoff, and 1.2 s for a 20 m standoff.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Digital pulse analysis for fast neutron recoil spectroscopy with a 4 He scintillation detector

Helium-4-based fast neutron scintillation detectors are an attractive alternative to pulse-shape discrimination-capable organic scintillators for fast neutron detection and spectroscopy, as the response of the detectors to gamma rays is intrinsically limited to low energy deposition. Consequently, the neutron recoil distribution can be measured with these detectors without the need for pulse shape analysis. In this work, the response of an Arktis S670 4 He scintillation detector to D-D, D-T, and 252 Cf neutrons was measured. The detector has a unique construction and readout mechanism, with multiple output channels observing the same scintillation event, and an analysis method was developed to aggregate the outputs from all channels into a single list. The D-D and D-T neutron responses were used to perform a two-point energy calibration, which yielded a near-zero intercept, suggesting that the 4 He scintillation medium behaves linearly to a higher energy than previously reported, and that a two-point calibration is sufficient for nuclear recoil energies below 9 MeV. As a result, the detector was measured to have 16.7-ns FWHM time resolution when using the developed custom analysis, a reduction of 4.9 ns when compared to the conventional pulse analysis.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron Guide System for Ultracold and Cold Neutrons at the WWR-M Reactor

The results of calculation of fluxes of ultracold (UCNs), very cold, and cold neutrons at the output of neutron guides of the UCN source with superfluid helium at the WWR-M reactor are presented. UCN density ρ{sub 35L} = 1.3 × 10{sup 4} n/cm{sup 3} in the trap of the electric dipole moment (EDM) spectrometer was obtained by optimizing source parameters. This UCN density in the EDM spectrometer is two orders of magnitude higher than the UCN density at the output of the available UCN sources. The flux density of cold neutrons with a wavelength of 2–20 Å at the output of a neutron guide with a cross section of 30 × 200 mm{sup 2} should be as high as 1.1 × 10{sup 8} n/(cm{sup 2} s), while the flux density of very cold neutrons (50–100 Å) at the output of the same neutron guide should be 2.3 × 10{sup 5} n/(cm{sup 2} s). An extensive program of fundamental and applied physical research was mapped out for this source.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Proton Radiography: Cross Section Measurements and Detector Development

Proton radiography has become an important tool for predicting the performance of stockpiled nuclear weapons. Current proton radiography experiments at LANSCE are confined to relatively small targets on the order of centimeters in size because of the low beam energy. LANL scientists have made radiographs with 12 and 24 GeV protons produced by the accelerator at Brookhaven National Laboratory. These energies are in the range required for hydrotest radiography. The design of a facility for hydrotest radiography requires knowledge of the cross sections for producing high-energy particles in the forward direction, which are incorporated into the Monte Carlo simulation used in designing the beam and detectors. There are few existing measurements of neutron production cross sections for proton-nuclei interactions in the 50 GeV range, and almost no data exist for forward neutron production, especially for heavy target nuclei. Thus the data from the MIPP EMCAL and HCAL, for which our group was responsible, are critical to proton radiography. Since neutrons and photons cannot be focused by magnets, they cause a background “fog” on the images. This problem can be minimized by careful design of the focusing system and detectors. The purpose of our research was to measure forward production of neutrons produced by high-energy proton beams striking a variety of targets. The forward-going particles carry most of the energy from a high-energy proton interaction, so these are the most important to proton radiography. This work was carried out in conjunction with the Fermilab E-907 (MIPP) collaboration. Our group was responsible for designing and building the E907 forward neutron and photon calorimeters. With the support of our Stewardship Science Academic Alliances grants, we were able to design, build, and commission the calorimeters on budget and ahead of schedule. The MIPP experiment accumulated a large amount of data in the first run that ended in early 2006. Our group has almost completed the analysis the forward neutron production data. Large dis-crepancies between our neutron production data and Monte Carlo expectations have been found.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Laser and optical system for laser assisted hydrogen ion beam stripping at SNS

A high-efficiency laser assisted hydrogen ion (H-) beam stripping was recently successfully carried out in the Spallation Neutron Source (SNS) accelerator. The experiment was not only an important step toward foil-less H- stripping for charge exchange injection, it also set up a first example of using megawatt ultraviolet (UV) laser source in an operational high power proton accelerator facility. This study reports in detail the design, installation, and commissioning result of a macro-pulsed multi-megawatt UV laser system and laser beam transport line for the laser stripping experiment.

43 PARTICLE ACCELERATORS↗

Structure and lattice excitations of the copper substituted lead oxyapatite Pb 9.06⁢(7)⁢ Cu 0.94⁢(6)⁢ (PO 3.92⁢(4) ) 6 ⁢O 0.96⁢(3)

The copper substituted lead oxyapatite, Pb 10-x⁢ Cu x (PO 3.92⁢(4) ) 6 ⁢O 0.96⁢(3) [x = 0.94(6)] was studied using neutron and x-ray diffraction and neutron spectroscopy techniques. The crystal structure of the main phase of our sample, which has come to be colloquially known as LK-99, is verified to possess a hexagonal structure with space group P6 3 /m, alongside the presence of impurity phases Cu and Cu 2 ⁢S. We determine the primary substitution location of the Cu as the Pb1 (6⁢ℎ) site, with a small substitution at the Pb2 (4⁢f) site. Consequently, no clear Cu-doping-induced structural distortion was observed in the investigated temperature region between 10 K and 300 K. Specially, we did not observe a reduction of coordinate number at the Pb2 site or a clear tilting of PO 4 tetrahedron. Magnetic characterization reveals a diamagnetic signal in the specimen, accompanied by a very weak ferromagnetic component at 2 K. No long-range magnetic order down to 10 K was detected by the neutron diffraction. Inelastic neutron scattering measurements did not show magnetic excitations for energies up to 350 meV. There is no sign of a superconducting resonance in the excitation spectrum of this material. The measured phonon density of states compares well with density functional theory calculations performed for the main LK-99 phase and its impurity phases. Our study may shed some insight into the role of the favored substitution site of copper in the absence of structural distortion and superconductivity in LK-99.

36 MATERIALS SCIENCE↗